More transparency in your process automation Status monitoring via Ethernet with the ACT20C Let’s connect. Analogue signal conditioning Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this Many process parameters in your system are handled by your control system, which shows you the current status of your process. Even so, do you have a full overview of critical system states? And this at all times, at every location, and with the recent system history? With the ACT20C, you receive accurate information on the status of the sensors, signal processing and cabling. Data can be called up and will depending on your individual communications infrastructure. This comprehensive overview allows you to accurately analyse errors and faults, and initiate targeted actions taken by system operators and maintenance personnel. By doing so, this technology contributes to ensuring reliable system operation. ACT20C signal conditioner with Ethernet interface Comprehensive process transparency is provided by the transfer of diagnostics information, signals and data You would like more process transparency for your systems. We support you with signal conditioners that supply you with precise information via our Ethernet interace. Let’s connect. To be able to control systems and processes optimally, you require a constant flow of information on the current states of individual applications, devices and functions. Our ACT20C signal conditioner not only monitors the signal conversion, but also communicates precise information on device status, signals and data directly to connected computer and control systems. Our Ethernet interface enables an event-controlled transfer of diagnostics information, which in turn supports the elimination of faults in, for example, plant operation. Universal signal conversion Can be used in a multitude of applications thanks to customer and application specific defined conversion methods with just one single module. ETH I, U I, U PS Simple operation and configuration Software supported configuration allows a fast application of settings and simple operation. Simple remote access Continuous monitoring of device and system functions, simple and affordable integration of existing Ethernet networks. Detailed analysis and presentation of core process parameters The ACT20C supplies key parameters and historical data, independent of the location Thanks to the ACT20C, Weidmüller is now the first to offer a solution which supplies you with extensive diagnostic and status information without the need to deal with the complexity of field bus systems. the front panel or via the Ethernet, and performance is ensured through the manufacturer-independent FDT/DTM software platform. To work with this platform, Weidmüller provides the WI-Manager universal FDT frame application. The isolating converters are based on the proven, robust technology of transferring analogue signals to the DCS system. Various signal sources and field devices can be connected to the input side of the isolating converters. As a result of this, the ACT20C can be configured for the user-defined processing of current, voltage and transmitter signals. Access is accomplished via a service interface on Data collected in the ACT20C is made available over the Ethernet via Modbus TCP. Depending on the communications infrastructure, you can make this data available to your SCADA system within your network, and you can also access it via the Internet from any location using an industrial Ethernet router. Let’s connect. Visit the life application of the ACT20C until 31.12.2013 by using http://act20c-weidmueller.com or scan this QR code. Network Enabled Signal Conditioner for Current and Voltage Signals •Scalable current or voltage input •Current or voltage output •Configurable limit monitoring •Diagnostics on the device status, signals and line faults using Modbus •PC configuration with FDT / DTM software, download at www.weidmueller.com ACT20C-AI-AO-MTCP-S U I – V I – + mA 12 + – Tx + 13 U RJ45 11 ETH I, U 14 I, U PS 63 – 64 + 51 – 52 + I – + 53 54 24 V DC Technical data Input Input current Input voltage Sensor supply Output Output current Output voltage Load impedance current Load impedance voltage Under / over-load range Signal processing Transfer function Limit monitoring Condition monitoring Diagnosis General data Supply voltage Power consumption Deviation *) Resolution / accuracy *) Temperature coefficient Ambient temperature (Operation) Ambient temperature (Storage/Transport) Height (operation) Humidity Protection degree / mounting position Electrical isolation Galvanic insulation**) Input to Output / Power / Ethernet Output to Input / Power / Ethernet Ethernet to Power Functional earth to Power / Ethernet Functional earth to Input / Output Pollution severity Communication Ethernet Transfer rate Protocol Service Interface Konfiguration Addressing Conformity Approvals Standards **) Recommendations Mechanical specifications Length / Width / Height Weight Clamping range (nominal / min. / max.) *) At 23 °C ambient temperature and 24 V supply voltage. Note **) Certification acc. EN 61010-1:2010 in preparation. 0/4... 20 mA 0/2… 10 V DC ≥ 17 V DC @ 20 mA (-20… +55 °C) 0/4… 20 mA 0… 10 V ≤ 500 Ohm ≥ 10 k Ohm Namur NE43 linear, inverse Process alarms with adjustable delay and hysteresis Process value: sensor value, output value Device status, broken cable (input / output), short circuit (input / output), overload (sensor / output) 18 … 31.2 V DC <3W ≤ 0.15 % full scale (+ 0.05 % ≥ 55 °C) Current: 1 uA / 30 uA (+ 10 uA ≥ 55 °C) Voltage: 1 mV / 15 mv (+ 5 mV ≥ 55 °C) < 0.01 % / K -20… +70 °C -20… +85 °C < 2000 m < 95 % rel. (no condensation) IP 20 / any 4-way, between Input / Output / Power Supply / Ethernet Reinforced insulation acc. EN 61010-1:2010, Rated voltage 300 Veff at secondary circuits Basic insulation acc. EN 61010-1:2010, Rated voltage 31,2 Vdc at secondary circuits Basic insulation acc. EN 61010-1:2010, Rated voltage 300 Veff at secondary circuits 2 1 x RJ45, 10/100 MBit/s 10/100 MBit/s (automatic recognition of the transmission rate) Modbus TCP, FDT/DTM Jack for CBX200 USB FDT/DTM (Ethernet oder Service Interface) DHCP or manual setting CE EN 61010-1:2011, EN 61326-1:2006 Namur NE43, NE44, NE107 119.2 mm / 22.5 mm / 113.6 mm 180 g (max.) 2.5 / 0.5 / 2.5 mm² Ordering data Type ACT20C-AI-AO-MTCP-S Qty. 1 Order No. 1334490000 Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the technological challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we set standards in Industrial Connectivity. Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1440380000/03/2013/SMDM