FUJITSU MB3771PS

FUJITSU SEMICONDUCTOR
DATA SHEET
DS04-27400-7E
ASSP For power supply applications
BIPOLAR
Power Supply Monitor
MB3771
■ DESCRIPTION
The Fujitsu MB3771 is designed to monitor the voltage level of one or two power supplies (+5 V and an arbitrary
voltage) in a microprocessor circuit, memory board in large-size computer, for example.
If the circuit’s power supply deviates more than a specified amount, then the MB3771 generates a reset signal to
the microprocessor. Thus, the computer data is protected from accidental erasure.
Using the MB3771 requires few external components. To monitor only a +5 V supply, the MB3771 requires the
connection of one external capacitor. The level of an arbitrary detection voltage is determined by two external
resistors. The MB3771 is available in an 8-pin Dual In-Line, Single In-Line Package or space saving Flat Package.
■ FEATURES
•
•
•
•
•
•
•
•
•
Precision voltage detection (VSA = 4.2 V ± 2.5 %)
User selectable threshold level with hysterisis (VSB = 1.23 V ± 1.5 %)
Monitors the voltage of one or two power supplies (5 V and an arbitrary voltage, >1.23 V)
Usable as over voltage detector
Low voltage output for reset signal (VCC = 0.8 V typ.)
Minimal number of external components (one capacitor min.)
Low power dissipation (ICC = 0.35 mA typ., VCC = 5 V)
Detection threshold voltage has hysteresis function
Reference voltage is connectable.
■ PACKAGES
8-pin plastic DIP
8-pin plastic SIP
8-pin plastic SOIP
(DIP-8P-M01)
(SIP-8P-M03)
(FPT-8P-M01)
MB3771
■ PIN ASSIGNMENT
(FRONT VIEW)
(TOP VIEW)
8
RESET
7
VSA
CT
1
8
RESET
6
VSB / RESIN
VSC
2
7
VSA
5
VCC
OUTC
3
6
VSB /RESIN
4
GND
GND
4
5
VCC
3
OUTC
2
VSC
1
CT
(DIP-8P-M01)
(FPT-8P-M01)
(SIP-8P-M03)
■ BLOCK DIAGRAM
VCC
5
≅ 1.24 V
≅ 100 kΩ
+
+
− Comp. A
VSA 7
−
≅ 10 µA
−
+
2
VSC
4
GND
+
Comp. C
+
−
≅ 12 µA
−
≅ 40 kΩ
VSB / RESIN 6
≅ 1.24 V
REFERENCE VOLTAGE
R
Q
Comp. B
S
1
CT
2
8
3
RESET OUTC
MB3771
■ FUNCTIONAL DESCRIPTIONS
Comparators Comp.A and Comp.B apply a hysteresis to the detected voltage, so that when the voltage at either
the VSA or VSB pin falls below 1.23 V the RESET output signal goes to “low” level.
Comp. B may be used to detect any given voltage(Sample Application 3), and can also be used as a forced
reset pin (with reset hold time) with TTL input (Sample Application 6).
Note that if Comp.B is not used, the VSB pin should be connected to the VCC pin (Sample Application 1).
Instantaneous breaks or drops in the power supply can be detected as abnormal conditions by the MB3771
within a 2 µs interval. However because momentary breaks or drops of this duration do not cause problems in
actual systems in some cases, a delayed trigger function can be created by connecting capacitors to the VSA or
VSB pin (Sample Application 8).
Because the RESET output has built-in pull-up resistance, there is no need to connect to external pull-up
resistance when connected to a high impedance load such as a CMOS logic IC.
Comparator Comp. C is an open-collector output comparator without hysteresis, in which the polarity of input/
output characteristics is reversed. Thus Comp. C is useful for over-voltage detection (Sample Application 11)
and positive logic RESET signal output (Sample Application 7), as well as for creating a reference voltage
(Sample Application 10).
Note that if Comp. C is not used, the VSC pin should be connected to the GND pin (Sample Application 1).
■ FUNCTION EXPLANATION
VHYS
VS
VCC
0.8 V
VCC
CT
1
2
3
4
8
7
6
5
t
RESET
TPO
RESET
TPO
t
(1)
(2)
(3)
(4) (5) (6)
(7)
(8)
(1) When VCC rises to about 0.8V, RESET goes low.
(2) When VCC reaches VS +VHYS, CT then begins charging. RESET remains low during this time
(3) RESET goes high when CT begins charging.
TPO =: CT × 10 5 (Refer to CT pin capacitance vs. hold time )
(4) When VCC level dropps lower then VS, then RESET goes low and CT starts discharging.
(5) When VCC level reaches VS + VHYS, then CT starts charging.
In the case of voltage sagging, if the period from the time VCC goes lower than or equal to VS to the time VCC
reaches VS +VHYS again, is longer than tPI, (as specified in the AC Characteristics), CT is discharged and charged
successively.
(6) After TPO passes, and VCC level exceeds VS + VHYS, then RESET goes high.
(7) Same as Point 4.
(8) RESET remains low until VCC drops below 0.8V.
3
MB3771
■ ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Symbol
Power supply voltage
Input voltage
Power dissipation
Storage temperature
Unit
Min.
Max.
VCC
−0.3
+20
V
VSA
−0.3
VCC + 0.3 ( < +20)
V
VSB
−0.3
+20
V
VSC
−0.3
+20
V
PD

200 (Ta ≤ 85 °C)
mW
Tstg
−55
+125
°C
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Power supply voltage
Output current
Operating ambient temperature
Symbol
Value
Unit
Min.
Max.
VCC
3.5
18
V
IRESET
0
20
mA
IOUTC
0
6
mA
Top
−40
+85
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
4
MB3771
■ ELECTRICAL CHARACTERISTICS
1. DC Characteristics
Parameter
Power supply current
(VCC = 5 V, Ta = + 25 °C)
Symbol
Typ.
Max.
Unit

350
500
µA
ICC2
VSB = 0 V, VSC = 0 V

400
600
µA
VCC
4.10
4.20
4.30
V
Ta = −40 °C to +85 °C
4.05
4.20
4.35
V
VCC
4.20
4.30
4.40
V
Ta = −40 °C to +85 °C
4.15
4.30
4.45
V
50
100
150
mV
VSB
1.212
1.230
1.248
V
Ta = −40 °C to +85 °C
1.200
1.230
1.260
V

3
10
mV
14
28
42
mV
VSAH (UP)

VHYSA
VSB
Deviation of detection voltage
∆VSB
Hysterisis width
VHYSB
Input current
Min.
VSB = 5 V, VSC = 0 V
Detection voltage
Detection voltage
Value
ICC1
VSAL
(DOWN)
Hysterisis width
Conditions
VCC = 3.5 V to 18 V

IIHB
VSB = 5 V

0
250
nA
IILB
VSB = 0 V

20
250
nA
IRESET = −5 µA, VSB = 5 V
4.5
4.9

V
IRESET = 3mA, VSB = 0 V

0.28
0.4
V
IRESET = 10mA, VSB = 0 V

0.38
0.5
V
“H” level output voltage
VOHR
Output saturation voltage
VOLR
Output sink current
IRESET
VOLR = 1.0 V, VSB = 0 V
20
40

mA
CT charge current
ICT
VSB = 5 V, VCT = 0.5 V
9
12
16
µA
IIHC
VSC = 5 V

0
500
nA
IILC
VSC = 0 V

50
500
nA
1.225
1.245
1.265
V
1.205
1.245
1.285
V
Input current
Detection voltage
VSC

Ta = −40 °C to +85 °C
Deviation of detection voltage
∆VSC
VCC = 3.5 V to 18 V

3
10
mV
Output leakage current
IOHC
VOHC = 18 V

0
1
µA
Output saturation voltage
VOLC
IOUTC = 4 mA, VSC = 5 V

0.15
0.4
V
Output sink current
IOUTC
VOLC = 1.0 V, VSC = 5 V
6
15

mA
Reset operation minimum
supply voltage
VCCL
VOLR = 0.4 V, IRESET = 200 µA

0.8
1.2
V
5
MB3771
2. AC Characteristics
(VCC = 5 V, Ta = + 25 °C, CT = 0.01 µF)
Symbol
Conditions
VSA, VSB input pulse width
tPI
RESET output pulse width
tPO
Parameter
RESET rise time
tr
RESET fall time
tf
Propagation delay time
PHL 2
t
*
PLH 2
t
*1: In case of VSB termination.
*2: In case of VSC termination.
6
Typ.
Max.

5.0


µs

0.5
1.0
1.5
ms

1.0
1.5
µs

0.1
0.5
µs

2
10
µs

0.5

µs

1.0

µs

*
RL = 2.2 kΩ,
CL = 100 pF
Unit
Min.
RL = 2.2 kΩ,
CL = 100 pF
tPD*1
Value
MB3771
■ APPLICATION CIRCUIT
1. 5V Power Supply Monitor
Monitored by VSA. Detection threshold voltage is VSAL and VSAH
VCC
MB3771
CT
1
8
2
3
4
7
6
5
RESET
Logic
circuit
2. 5V Power Supply Voltage Monitor (Externally Fine-Tuned Type)
The VSA detection voltage can be adjusted externally.
Resistance R1 and R2 are set sufficiently lower than the IC internal partial voltage resistance, so that the detection
voltage can be set using the ratio between resistance R1 and R2. (See the table below).
• R1, R2 calculation formula (when R1 << 100 kΩ, R2 <<40 kΩ)
VSAL =: (R1 + R2 ) × VSB /R2 [V], VSAH =: (R1 + R2 ) × (VSB + VHYSB) / R2 [V]
R1 (kΩ)
R2 (kΩ)
Detection voltage : VSAL (V) Detection voltage : VSAH (V)
10
3.9
4.37
4.47
9.1
3.9
4.11
4.20
VCC
MB3771
CT
1
2
3
4
8
7
6
5
RESET
R1
R2
Logic
Circuit
7
MB3771
3. Arbitrary Voltage Supply Monitor
(1) Case: VCC ≤ 18 V
• Detection Voltage can be set by R1 and R2.
Detection Voltage = (R1 + R2) × VSB/R2
• Connect Pin 7 to VCC when VCC less than 4.45 V.
• Pin 7 can be opened when VCC greater than 4.45 V
Power Dissipation can be reduced.
Note : Hysteresis of 28 mV at VSB at termination is available.
Hysteresis width dose not depend on (R1 + R2).
VCC
MB3771
1
2
3
4
CT
8
7
6
5
RESET
R1
R2
(2) Monitoring VCC > 18 V
• Detection Voltage can be set by R1 and R2
Detection Voltage = (R1 + R2) × VSB/R2
• The RESET signal output is =: 0V (low level) and =: 5 V (high level). VCC voltage cannot be output.
Do not pull up RESET to VCC.
• Changing the resistance ratio between R4 and R5 changes the constant voltage output, thereby changing the
voltage of the high level RESET output. Note that the constant voltage output should not exceed 18 V.
• The 5 V output can be used as a power supply for control circuits with low current consumption.
• In setting the R3 resistance level, caution should be given to the power consumption in the resistor. The table
below lists sample resistance values for reference (using 1/4 Ω resistance).
VCC (V)
Detection
voltage (V)
RESET Output min.
power supply voltage (V)
R1 (MΩ)
R2 (kΩ)
R3 (kΩ)
140
100
6.7
1.6
20
110
< 0.2
100
81
3.8
1.3
20
56
< 0.5
40
33
1.4
0.51
20
11
< 1.6
Output Current
(mA)
• Values are actual measured values (using IOUTC = 100 µA, VOLC = 0.4 V). Lowering the resistance value of R3
reduces the minimum supply voltage of the RESET output, but requires resistance with higher allowable loss.
VCC
R3
5 V output(Stablized)
CT
R4:
100 kΩ
R5:
33 kΩ
8
0.47 µF
1
8
2
7
3
6
4
5
RESET
R1
R2
MB3771
4. 5 V and 12 V Power Supply Monitor (2 types of power supply monitor VCC1 = 5 V, VCC2 =12 V)
• 5 V is monitored by VSA. Detection voltage is about 4.2 V
• 12 V is monitored by VSB. When R1 = 390 kΩ and R2 = 62 kΩ, Detection voltage is about 9.0 V.Generally the
detection voltage is determined by the following equation.
Detection Voltage = (R1 + R2) × VSB/R2
VCC2
VCC1
MB3771
CT
1
2
3
4
8
7
6
5
RESET
R1: 390 kΩ
Logic
circuit
R2: 62 kΩ
5. 5 V and 12 V Power Supply Monitor (RESET signal is generated by 5 V, VCC1 = 5 V, VCC2 = 12 V)
• 5 V is monitored by VSA, and generates RESET signal when VSA detects voltage sagging.
• 12 V is monitored by VSC, and generates its detection signal at OUTC.
• The detection voltage of 12 V monitoring and its hysterisis is determined by the following equations.
R1 + R2 + R3
Detection voltage =
× VSC
(8.95 V in the circuit above)
R2 + R3
Hysterisis width =
R1 (R3 - R3 // R4)
(R2 + R3) (R2 + R3 // R4)
× VSC
(200 mV in the circuit above)
VCC2
VCC1
R L: 10 kΩ
MB3771
R5: 100 kΩ
R1: 390 kΩ
1
2
3
4
R2: 33 kΩ
R4: 510 kΩ
8
7
6
5
RESET
IRQ
or
Port Logic Circuit
CT
R3: 30 kΩ
9
MB3771
6. 5 V Power Supply Monitor with forced RESET input (VCC = 5 V)
RESIN is an TTL compatible input.
RESIN
VCC
MB3771
CT
1
8
2
7
3
4
6
5
RESET
Logic Circuit
7. 5 V Power Supply Monitor with Non-inverted RESET
In this case, Comparator C is used to invert RESET signal. OUTC is an open-collector output.
RL is used an a pull-up resistor.
VCC
MB3771
RL: 10 kΩ
1
2
3
4
CT
RESET
8
7
6
5
8. Supply Voltage Monitoring with Delayed Trigger
When the voltage shown in the diagram below is applied at VCC, the minimum value of the input pulse width is
increased to 40 µs (when C1 = 1000 pF).
The formula for calculating the minimum value of the input pulse width [TPI] is:
TPI [µs] =: 4 × 10-2 × C1 [pF]
TP
VCC
5V
4V
MB3771
CT
10
1
2
3
4
8
7
6
5
RESET
C1
MB3771
9. Dual (Positive/Negative) Power Supply Voltage Monitoring (VCC = 5 V, VEE = Negative Power
Supply)
Monitors a 5 V and a negative (any given level) power supply. R1, R2, and R3 should be the same value.
Detection Voltage = VSB - VSB × R4/R3
Example if VEE = -5 V, R4 = 91 kΩ
Then the detected voltage = -4.37 V
In cases where VEE may be output when VCC is not output, it is necessary to use a Schottky barrier diode (SBD).
VCC
R5 : 5.1 kΩ
MB3771
R4
VEE
R3 :
20 kΩ
0.22 µF
CT
SBD
1
8
2
7
3
6
4
5
RESET
R1 : 20 kΩ
R2 : 20 kΩ
10. Reference Voltage Generation and Voltage Sagging Detection
(1) 9V Reference Voltage Generation and 5V/9V Monitoring
Detection Voltage = 7.2 V
In the above examples, the output voltage and the detection voltage are determined by the following equations:
Detection Voltage = (R1 + R2) × VSB/R2
15 V
R 5 : 3 kΩ
V CC : 5 V
MB3771
CT
0.47 µF
1
2
3
4
8
7
6
5
RESET
R3 :
7.5 kΩ
R4 :
1.2 kΩ
9 V (≅ 50 mA)
R 1: 300 kΩ
R 2: 62 kΩ
11
MB3771
(2) 5 V Reference Voltage Generation and 5V Monitoring (No.1)
Detection Voltage = 4.2 V
In the above examples, the output voltage and the detection voltage are determined by the following equations:
Output Voltage = (R3 + R4) × VSC/R4
15 V
R5 : 3 kΩ
MB3771
CT
0.47 µF
8
7
6
5
1
2
3
4
RESET
5 V(≅ 50 mA)
R3 : 3.6 kΩ
R4 : 1.2 kΩ
(3) 5 V Reference Voltage Generation and 5 V Monitoring (No. 2)
The value of R1 should be calculated from the current consumption of the MB3771, the current flowing at R2 and
R3, and the 5 V output current. The table below provides sample resistance values for reference.
VCC (V)
R1 (kΩ)
Output Current (mA)
40
11
< 1.6
24
6.2
< 1.4
15
4.7
< 0.6
VCC
R1
CT
1
8
2
7
3
4
6
5
RESET
5V
R2 :
100 kΩ
0.47 µF
R3 : 33 kΩ
GND
(4) 1.245 V Reference Voltage Generation and 5 V Monitoring
Resistor R1 determines Reference current. Using 1.2 kΩ as R1, reference current is about 2 mA.
VCC
(5 V)
R1 : 10 kΩ
CT
0.47 µF
GND
12
1
8
2
7
3
4
6
5
RESET
Reference Voltage
1.245V typ.
MB3771
11. Low Voltage and Over Voltage Detection (VCC = 5 V)
VSH has no hysteresis. When over voltage is detected, RESET is held in the constant time as well as when
low voltage is detected.
VSL = (R1 + R2) × VSB/R2
VSH = (R3 + R4) × VSC/R4
VCC
R3
R1
MB3771
RESET
R4
1
2
3
4
CT
8
7
6
5
RESET
R2
VSL
VSH
VCC
12. Detection of Abnormal State of Power Supply System (VCC = 5 V)
• This Example circuit detects abnormal low/over voltage of power supply voltage and is indicated by LED
indicator. LED is reset by the CLEAR key.
• The detection levels of low/over voltages are determined by VSA, and R1 and R2 respectively.
VCC
LED
R1
R3: 620 Ω
MB3771
R2
1
2
3
4
8
7
6
5
CLEAR
R4:
1 kΩ to 100 kΩ
13
MB3771
13. Back-up Power Supply System (VCC = 5 V)
•
•
•
•
Use CMOS Logic and connect VDD of CMOS logic with VCCO.
The back-up battery works after CS goes high as V2 < V1.
During tPO, memory access is prohibited.
CS‘s threshold voltage V1 is determined by the following equation:
V1 = VF + (R1 + R2 + R3) × VSB/R3
When V1 is 4.45 V or less, connect 7 pin with VCC.
When V1 is 4.45 V or more, 7 pin can be used to open.
• The voltage to change V2 is provided as the following equation:
V2 = VF + (R1 + R2 + R3) × VSC/ (R2 + R3)
However, please set V2 to 3.5 V or more.
VCC
V1
V2
t
CS
TPO
t
VCCO
t
VCC
MB3771
CT
1
2
D1
V F 0.6 V
R4 >1 kΩ
R 1: 100 kΩ
R 5: 100 kΩ
R 2: 6.2 kΩ
3
8
7
6
4
5
R 6: 100 kΩ
VCCO
CS
R3: 56 kΩ
*: Diode has been added to prevent Comp.C from malfunctionig when VCC voltage is low.
Set V1 and V2 with care given to VF temperature characteristics (typically negative temperature
characteristics).
14
MB3771
■ TYPICAL CHARACTERISTICS
Detection voltage VSC (V)
700
600
500
400
25°C
−40°C
300
−40°C 85°C
200
25°C
100
0
85°C
0
5
10
15
Power supply voltage VCC (V)
600
85°C 25°C
400
−40°C
300
−40°C
200
25°C
100
0
85°C
0
5
10
15
1.25
−25
0
25
50
75
100
Anbient temperature Ta (°C)
700
500
1.30
1.20
− 50
20
Power supply current vs. power supply voltage
Power supply current ICC2 (µA)
Detection voltage (VSC) vs. anbient temperature
20
Power supply voltage VCC (V)
Detection voltage (VSB) vs. anbient temperature
Detection voltage VSBH,VSBL (V)
Power supply current ICC1 (µA)
Power supply current vs. power supply voltage
1.30
VSBH
1.25
VSBL
1.20
−50
−25
0
25
50
75
100
Anbient temperature Ta (°C)
Output voltage VOLR (V)
5
4
3
2
1
Ta=
25°C
0 85°C
0
−40°C
1
2
3
4
Power supply voltage VCC (V)
5
Detection voltage VSAH,VSAL (V)
Output (RESET) voltage vs. power supply voltage Detection voltage (VSA) vs. anbient temperature
4.5
4.4
VSAH
4.3
VSAL
4.2
4.1
4.0
−50
−25
0
25
50
75
100
Anbient temperature Ta (°C)
(Continued)
15
MB3771
(Continued)
Reset voltage (RESET) vs. output current
1.27
5.0
VSBH
1.26
Reset voltage VOHR (V)
Detection voltage VSC, VSBL,VSBH (V)
Detection voltage (VSB, VSC) vs. Power supply voltage
VSC
1.25
1.24
VSBL
1.23
1.22
1.21
1.20
0
5
10
15
20
Ta = − 40°C
25°C
4.0
Output voltage VOLR (V)
Ta = − 40°C
25°C
85°C
0.5
0
0
5
10
15
Ta = − 40°C
85°C
1.0
25°C
0
20
0
1.0
Ta = 25°C
− 40°C
85°C
10 µ
1µ
1 p 10 p 100 p 1000 p 0.01µ 0.1 µ 1 µ 10 µ 100 µ
CT pin capacitance CT (F)
16
Output voltage VOLC (V)
Reset hold time (s)
10
100 m
20
30
40
50
Output voltage (OUTC) vs. output current
CT pin capacitance vs. reset hold time
1
10
Output current IRESET (mA)
Power supply voltage VCC (V)
100 µ
−15
Output (RESET) voltage vs. output current
2.0
1.0
1m
−10
Output current IOH (µA)
1.5
10 m
−5
0
Power supply voltage VCC (V)
Reset hold time vs. power supply voltage (CT = 0.01µF)
Reset hold time tPO (ms)
85°C
4.5
Ta = − 40°C
25°C
85°C
0.5
0
0
5
10
15
Output current IOUTC (mA)
20
MB3771
■ ORDERING INFORMATION
Part number
Package
MB3771P
8-pin Plastic DIP
(DIP-8P-M01)
MB3771PS
8-pin Plastic SIP
(SIP-8P-M03)
MB3771PF
8-pin Plastic SOP
(FPT-8P-M01)
Remarks
17
MB3771
■ PACKAGE DIMENSIONS
8-pin Plastic DIP
(DIP-8P-M01)
+0.40
9.40 –0.30
+.016
.370 –.012
6.20±0.25
(.244±.010)
1 PIN INDEX
0.51(.020)MIN
4.36(.172)MAX
0.25±0.05
(.010±.002)
3.00(.118)MIN
0.46±0.08
(.018±.003)
+0.30
0.99 –0
+.012
.039 –0
+0.35
0.89 –0.30
+.014
.035 –.012
C
1994 FUJITSU LIMITED D08006S-2C-3
+0.30
1.52 –0
+.012
.060 –0
7.62(.300)
TYP
15°MAX
2.54(.100)
TYP
Dimensions in mm (inches)
(Continued)
18
MB3771
(Continued)
8-pin Plastic SIP
(SIP-8P-M03)
3.26±0.25
(.128±.010)
+0.15
19.65 –0.35
+.006
.774 –.014
INDEX-1
6.20±0.25
(.244±.010)
8.20±0.30
(.323±.012)
INDEX-2
+0.30
0.99 –0
4.00±0.30
(.157±.012)
+.012
.039 –0
+0.30
1.52 –0
2.54(.100)
TYP
C
0.25±0.05
(.010±.002)
0.50±0.08
(.020±.003)
+.012
.060 –0
Dimensions in mm (inches)
1994 FUJITSU LIMITED S08010S-3C-2
8-pin Plastic SOP
(FPT-8P-M01)
+0.25
2.25(.089)MAX
(Mounting height)
+.010
6.35 –0.20 .250 –.008
0.05(.002)MIN
(STAND OFF)
5.30±0.30
(.209±.012)
INDEX
1.27(.050)
TYP
0.45±0.10
(.018±.004)
3.81(.150)REF
+0.40
6.80 –0.20
7.80±0.40
(.307±.016)
+.016
.268 –.008
+0.05
Ø0.13(.005)
M
0.15 –0.02
+.002
.006 –.001
0.50±0.20
(.020±.008)
Details of "A" part
0.20(.008)
0.50(.020)
"A"
0.18(.007)MAX
0.10(.004)
C
1994 FUJITSU LIMITED F08002S-4C-4
0.68(.027)MAX
Dimensions in mm (inches)
19
MB3771
FUJITSU LIMITED
For further information please contact:
Japan
FUJITSU LIMITED
Corporate Global Business Support Division
Electronic Devices
KAWASAKI PLANT, 4-1-1, Kamikodanaka,
Nakahara-ku, Kawasaki-shi,
Kanagawa 211-8588, Japan
Tel: +81-44-754-3763
Fax: +81-44-754-3329
http://www.fujitsu.co.jp/
North and South America
FUJITSU MICROELECTRONICS, INC.
3545 North First Street,
San Jose, CA 95134-1804, USA
Tel: +1-408-922-9000
Fax: +1-408-922-9179
Customer Response Center
Mon. - Fri.: 7 am - 5 pm (PST)
Tel: +1-800-866-8608
Fax: +1-408-922-9179
http://www.fujitsumicro.com/
Europe
FUJITSU MICROELECTRONICS EUROPE GmbH
Am Siebenstein 6-10,
D-63303 Dreieich-Buchschlag,
Germany
Tel: +49-6103-690-0
Fax: +49-6103-690-122
http://www.fujitsu-fme.com/
Asia Pacific
FUJITSU MICROELECTRONICS ASIA PTE LTD
#05-08, 151 Lorong Chuan,
New Tech Park,
Singapore 556741
Tel: +65-281-0770
Fax: +65-281-0220
http://www.fmap.com.sg/
F0001
 FUJITSU LIMITED Printed in Japan
All Rights Reserved.
The contents of this document are subject to change without
notice.
Customers are advised to consult with FUJITSU sales
representatives before ordering.
The information and circuit diagrams in this document are
presented as examples of semiconductor device applications,
and are not intended to be incorporated in devices for actual use.
Also, FUJITSU is unable to assume responsibility for
infringement of any patent rights or other rights of third parties
arising from the use of this information or circuit diagrams.
The contents of this document may not be reproduced or copied
without the permission of FUJITSU LIMITED.
FUJITSU semiconductor devices are intended for use in
standard applications (computers, office automation and other
office equipments, industrial, communications, and
measurement equipments, personal or household devices, etc.).
CAUTION:
Customers considering the use of our products in special
applications where failure or abnormal operation may directly
affect human lives or cause physical injury or property damage,
or where extremely high levels of reliability are demanded
(such as aerospace systems, atomic energy controls, sea floor
repeaters, vehicle operating controls, medical devices for life
support, etc.) are requested to consult with FUJITSU sales
representatives before such use. The company will not be
responsible for damages arising from such use without prior
approval.
Any semiconductor devices have inherently a certain rate of
failure. You must protect against injury, damage or loss from
such failures by incorporating safety design measures into your
facility and equipment such as redundancy, fire protection, and
prevention of over-current levels and other abnormal operating
conditions.
If any products described in this document represent goods or
technologies subject to certain restrictions on export under the
Foreign Exchange and Foreign Trade Control Law of Japan, the
prior authorization by Japanese government should be required
for export of those products from Japan.