STMICROELECTRONICS M41T81M6TR

M41T81
SERIAL ACCESS RTC WITH ALARMS
FEATURES SUMMARY
■ 2.0 TO 5.5V CLOCK OPERATING VOLTAGE
■
COUNTERS FOR TENTHS/HUNDREDTHS
OF SECONDS, SECONDS, MINUTES,
HOURS, DAY, DATE, MONTH, YEAR, and
CENTURY
■
AUTOMATIC SWITCH-OVER and DESELECT
CIRCUITRY
■
SERIAL INTERFACE SUPPORTS I2C BUS
(400KHz PROTOCOL)
■
PROGRAMMABLE ALARM and INTERRUPT
FUNCTION (valid even during Battery Back-up
Mode)
■
WATCHDOG TIMER
■
LOW OPERATING CURRENT OF 400µA
■
BATTERY BACK-UP NOT RECOMMENDED
FOR 3.0V APPLICATIONS (CAPACITOR
BACK-UP ONLY)
■
BATTERY OR SUPER-CAP BACK-UP
■
OPERATING TEMPERATURE OF –40 TO
85°C
■
ULTRA-LOW BATTERY SUPPLY CURRENT
OF 1µA
■
Figure 1. 8-pin SOIC Package
PACKAGE OPTIONS INCLUDE A 28-LEAD or
18-LEAD EMBEDDED CRYSTAL SOIC
8
1
SO8 (M)
Figure 2. 28-pin (300mil) SOIC Package*
EMBEDDED Crystal
SOX28 (MX)
Figure 3. 18-pin (300mil) SOIC Package*
EMBEDDED Crystal
18
1
SOX18 (MY)
September 2003
Rev. 2.0
1/28
M41T81
TABLE OF CONTENTS
SUMMARY DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Figure 4. Logic Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 1. Signal Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Figure 5. 8-pin SOIC (M) Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 7. 28-pin, 300mil SOIC (MX) Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 6. 18-pin, 300mil SOIC (MY) Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 8. Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
MAXIMUM RATING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 2. Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
DC AND AC PARAMETERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 3. Operating and AC Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 9. AC Measurement I/O Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 4. Capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 5. DC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 6. Crystal Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2-Wire Bus Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 10. Serial Bus Data Transfer Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 11. Acknowledgement Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 12. Bus Timing Requirements Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 7. AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
READ Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 13. Slave Address Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 14. READ Mode Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 15. Alternative READ Mode Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
WRITE Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 16. WRITE Mode Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Data Retention Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 17. Power Down/Up Mode AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8. Power Down/Up AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9. Power Down/Up Trip Points DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 14
. . . . 14
. . . . 14
. . . . 14
CLOCK OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
TIMEKEEPER® Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 10. TIMEKEEPER® Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Calibrating the Clock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Setting Alarm Clock Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 18. Alarm Interrupt Reset Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2/28
M41T81
Figure 19. Back-up Mode Alarm Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 11. Alarm Repeat Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Square Wave Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 12. Square Wave Output Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Century Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Output Driver Pin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Preferred Initial Power-on Default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 13. Preferred Default Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 20. Crystal Accuracy Across Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 21. Clock Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PACKAGE MECHANICAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
REVISION HISTORY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3/28
M41T81
SUMMARY DESCRIPTION
The M41T81 Serial Access TIMEKEEPER®
SRAM is a low power Serial RTC with a built-in
32.768 KHz oscillator (external crystal controlled).
Eight bytes of the SRAM (see Table 10, page 16)
are used for the clock/calendar function and are
configured in binary coded decimal (BCD) format.
An additional 12 bytes of SRAM provide status/
control of Alarm, Watchdog and Square Wave
functions. Addresses and data are transferred serially via a two line, bi-directional I2C interface. The
built-in address register is incremented automatically after each WRITE or READ data byte.
The M41T81 has a built-in power sense circuit
which detects power failures and automatically
switches to the battery supply when a power failure occurs. The energy needed to sustain the
SRAM and clock operations can be supplied by a
small lithium button supply when a power failure
occurs. Functions available to the user include a
non-volatile, time-of-day clock/calendar, Alarm interrupts, Watchdog Timer and programmable
Square Wave output. The eight clock address locations contain the century, year, month, date,
day, hour, minute, second and tenths/hundredths
of a second in 24 hour BCD format. Corrections for
28, 29 (leap year - valid until year 2100), 30 and 31
day months are made automatically.
The M41T81 is supplied in either an 8-pin SOIC or
an 18-pin (MY) or 28-pin (MX), 300mil SOIC package which includes an embedded 32kHz crystal.
The 8-pin and 28-pin, embedded crystal SOIC requires only a user-supplied battery to provide nonvolatile operation.
Figure 4. Logic Diagram
Table 1. Signal Names
VCC VBAT
Oscillator Input
XO(1)
Oscillator Output
IRQ/OUT/
FT/SQW
XI(1)
XO(1)
SCL
XI(1)
M41T81
Interrupt / Output Driver / Frequency
Test / Square Wave (Open Drain)
SDA
Serial Data Input/Output
SCL
Serial Clock Input
VBAT
Battery Supply Voltage
VCC
Supply Voltage
VSS
Ground
IRQ/FT/OUT/SQW
SDA
VSS
Note: 1. For SO8 package only.
AI04613
Note: 1. For SO8 package only.
4/28
M41T81
Figure 5. 8-pin SOIC (M) Connections
XI
XO
VBAT
VSS
1
2
3
4
M41T81
8
7
6
5
VCC
IRQ/FT/OUT/SQW
SCL
SDA
AI04769
Figure 6. 18-pin, 300mil SOIC (MY)
Connections
NC
NC
NC
NC
NC
NC
NC
VBAT
VSS
1
2
3
4
5
6
7
8
9
18
17
16
15
14
13
M41T81 12
11
10
NC
NC
NC
VCC
NC
IRQ/FT/OUT/SQW
NC
SCL
SDA
AI07830
Figure 7. 28-pin, 300mil SOIC (MX)
Connections
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
VBAT
VSS
1
28
27
2
26
3
25
4
24
5
23
6
7 M41T81 22
21
8
20
9
19
10
18
11
17
12
16
13
15
14
VCC
NC
IRQ/FT/OUT/SQW
NC
VSS
NC
SCL
NC
VCC(1)
NC
IRQ/FT/OUT/SQW(1)
SDA
SCL(1)
SDA(1)
AI07805
Note: 1. No Connect (NC) pin for 28-pin SOIC, but should be considered to have indicated function in anticipation of replacement with 18-pin SOIC.
Figure 8. Block Diagram
REAL TIME CLOCK
CALENDAR
32KHz
OSCILLATOR
CRYSTAL
RTC W/ALARM
& CALIBRATION
WDF
WATCHDOG
SDA
I2C
INTERFACE
SCL
WRITE
PROTECT
VCC
AFE
SQUARE WAVE
IRQ/FT/OUT/SQW(1)
SQWE
INTERNAL
POWER
VBAT
VSO(2)
Note 1. Open drain output
Note 2. VSO = VBAT – 0.5V (typ)
COMPARE
AI04616
5/28
M41T81
MAXIMUM RATING
Stressing the device above the rating listed in the
“Absolute Maximum Ratings” table may cause
permanent damage to the device. These are
stress ratings only and operation of the device at
these or any other conditions above those indicated in the Operating sections of this specification is
not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device
reliability.
Refer
also
to
the
STMicroelectronics SURE Program and other relevant quality documents.
Table 2. Absolute Maximum Ratings
Sym
Parameter
TSTG
Storage Temperature (VCC Off, Oscillator Off)
VCC
Supply Voltage
TSLD(1)
VIO
Lead Solder Temperature for 10 Seconds
Input or Output Voltages
SOIC
Value
Unit
–55 to 125
°C
–0.3 to 7
V
260
°C
–0.3 to Vcc+0.3
V
IO
Output Current
20
mA
PD
Power Dissipation
1
W
Note: 1. Reflow at peak temperature of 215°C to 225°C for < 60 seconds (total thermal budget not to exceed 180°C for between 90 to 120
seconds).
CAUTION: Negative undershoots below –0.3 volts are not allowed on any pin while in the Battery Back-Up Mode
6/28
M41T81
DC AND AC PARAMETERS
This section summarizes the operating and measurement conditions, as well as the DC and AC
characteristics of the device. The parameters in
the following DC and AC Characteristic tables are
derived from tests performed under the Measure-
ment Conditions listed in the relevant tables. Designers should check that the operating conditions
in their projects match the measurement conditions when using the quoted parameters.
Table 3. Operating and AC Measurement Conditions
Parameter
M41T81
Supply Voltage (VCC)
2.0 to 5.5V
Ambient Operating Temperature (TA)
–40 to 85°C
Load Capacitance (CL)
100pF
Input Rise and Fall Times
≤ 50ns
Input Pulse Voltages
0.2VCC to 0.8 VCC
Input and Output Timing Ref. Voltages
0.3VCC to 0.7 VCC
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 9. AC Measurement I/O Waveform
0.8VCC
0.7VCC
0.3VCC
0.2VCC
AI02568
Table 4. Capacitance
Parameter(1,2)
Symbol
CIN
COUT(3)
tLP
Max
Unit
7
pF
Output Capacitance
10
pF
Low-pass filter input time constant (SDA and SCL)
50
ns
Input Capacitance
Min
Note: 1. Effective capacitance measured with power supply at 5V; sampled only, not 100% tested.
2. At 25°C, f = 1MHz.
3. Outputs deselected.
7/28
M41T81
Table 5. DC Characteristics
Sym
Test Condition(1)
Parameter
Min
Typ
Max
Unit
0V ≤ VIN ≤ VCC
±1
µA
0V ≤ VOUT ≤ VCC
±1
µA
Switch Freq = 400kHz
400
µA
SCL,SDA = VCC – 0.3V
100
µA
ILI
Input Leakage Current
ILO
Output Leakage Current
ICC1
Supply Current
ICC2
Supply Current (standby)
VIL
Input Low Voltage
–0.3
0.3VCC
V
VIH
Input High Voltage
0.7VCC
VCC + 0.3
V
VOL
Output Low Voltage
IOL = 3.0mA
0.4
V
Output Low Voltage (Open Drain)(5)
IOL = 10mA
0.4
V
3
3.5(4)
V
0.6
1
µA
VBAT(2)
Battery Supply Voltage
IBAT
Battery Supply Current
Note: 1.
2.
3.
4.
5.
2.5(3)
TA = 25°C, VCC = 0V
Oscillator ON, VBAT = 3V
Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) as the battery supply.
After switchover (VSO), VBAT (min) can be 2.0V for crystal with RS = 40KΩ.
For rechargeable back-up, VBAT (max) may be considered VCC.
For IRQ/FT/OUT/SQW pin (Open Drain)
Table 6. Crystal Electrical Characteristics
Parameter(1,2,3)
Sym
fO
Resonant Frequency
RS
Series Resistance
CL
Load Capacitance
Min
Typ
Max
32.768
kHz
60
12.5
Units
kΩ
pF
Note: 1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38: 1TA/1TC252E127, Tuning Fork
Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal for industrial temperature operations. KDS can be contacted at [email protected] or http://www.kdsj.co.jp for further information on this crystal type.
2. Load capacitors are integrated within the M41T81. Circuit board layout considerations for the 32.768 kHz crystal of minimum trace
lengths and isolation from RF generating signals should be taken into account.
8/28
M41T81
OPERATION
The M41T81 clock operates as a slave device on
the serial bus. Access is obtained by implementing
a start condition followed by the correct slave address (D0h). The 20 bytes contained in the device
can then be accessed sequentially in the following
order:
1. Tenths/Hundredths of a Second Register
2. Seconds Register
3. Minutes Register
4. Century/Hours Register
5. Day Register
6. Date Register
7. Month Register
8. Year Register
9. Control Register
10. Watchdog Register
11 - 16. Alarm Registers
17 - 19. Reserved
20. Square Wave Register
The M41T81 clock continually monitors VCC for an
out-of-tolerance condition. Should VCC fall below
VSO, the device terminates an access in progress
and resets the device address counter. Inputs to
the device will not be recognized at this time to
prevent erroneous data from being written to the
device from a an out-of-tolerance system. The device also automatically switches over to the battery
and powers down into an ultra low current mode of
operation to conserve battery life. As system power returns and VCC rises above VSO, the battery is
disconnected, and the power supply is switched to
external VCC.
For more information on Battery Storage Life refer
to Application Note AN1012.
2-Wire Bus Characteristics
The bus is intended for communication between
different ICs. It consists of two lines: a bi-directional data signal (SDA) and a clock signal (SCL).
Both the SDA and SCL lines must be connected to
a positive supply voltage via a pull-up resistor.
The following protocol has been defined:
– Data transfer may be initiated only when the bus
is not busy.
– During data transfer, the data line must remain
stable whenever the clock line is High.
– Changes in the data line, while the clock line is
High, will be interpreted as control signals.
Accordingly, the following bus conditions have
been defined:
Bus not busy. Both data and clock lines remain
High.
Start data transfer. A change in the state of the
data line, from high to Low, while the clock is High,
defines the START condition.
Stop data transfer. A change in the state of the
data line, from Low to High, while the clock is High,
defines the STOP condition.
Data Valid. The state of the data line represents
valid data when after a start condition, the data line
is stable for the duration of the high period of the
clock signal. The data on the line may be changed
during the Low period of the clock signal. There is
one clock pulse per bit of data.
Each data transfer is initiated with a start condition
and terminated with a stop condition. The number
of data bytes transferred between the start and
stop conditions is not limited. The information is
transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition a device that gives out a message is
called “transmitter,” the receiving device that gets
the message is called “receiver.” The device that
controls the message is called “master.” The devices that are controlled by the master are called
“slaves.”
Acknowledge. Each byte of eight bits is followed
by one Acknowledge Bit. This Acknowledge Bit is
a low level put on the bus by the receiver whereas
the master generates an extra acknowledge related clock pulse. A slave receiver which is addressed is obliged to generate an acknowledge
after the reception of each byte that has been
clocked out of the slave transmitter.
The device that acknowledges has to pull down
the SDA line during the acknowledge clock pulse
in such a way that the SDA line is a stable Low during the High period of the acknowledge related
clock pulse. Of course, setup and hold times must
be taken into account. A master receiver must signal an end of data to the slave transmitter by not
generating an acknowledge on the last byte that
has been clocked out of the slave. In this case the
transmitter must leave the data line High to enable
the master to generate the STOP condition.
9/28
M41T81
Figure 10. Serial Bus Data Transfer Sequence
DATA LINE
STABLE
DATA VALID
CLOCK
DATA
START
CONDITION
CHANGE OF
DATA ALLOWED
STOP
CONDITION
AI00587
Figure 11. Acknowledgement Sequence
CLOCK PULSE FOR
ACKNOWLEDGEMENT
START
SCL FROM
MASTER
DATA OUTPUT
BY TRANSMITTER
1
MSB
2
8
9
LSB
DATA OUTPUT
BY RECEIVER
AI00601
10/28
M41T81
Figure 12. Bus Timing Requirements Sequence
SDA
tBUF
tHD:STA
tHD:STA
tR
tF
SCL
tHIGH
P
S
tLOW
tSU:STA
tSU:DAT
tHD:DAT
SR
tSU:STO
P
AI00589
Table 7. AC Characteristics
Parameter(1)
Sym
Min
Typ
Max
Units
400
kHz
fSCL
SCL Clock Frequency
tLOW
Clock Low Period
1.3
µs
tHIGH
Clock High Period
600
ns
0
tR
SDA and SCL Rise Time
300
ns
tF
SDA and SCL Fall Time
300
ns
tHD:STA
START Condition Hold Time
(after this period the first clock pulse is generated)
600
ns
tSU:STA
START Condition Setup Time
(only relevant for a repeated start condition)
600
ns
tSU:DAT(2)
Data Setup Time
100
ns
tHD:DAT
Data Hold Time
0
µs
tSU:STO
STOP Condition Setup Time
600
ns
Time the bus must be free before a new
transmission can start
1.3
µs
tBUF
Note: 1. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
2. Transmitter must internally provide a hold time to bridge the undefined region (300ns max) of the falling edge of SCL.
11/28
M41T81
READ Mode
In this mode the master reads the M41T81 slave
after setting the slave address (see Figure 14,
page 12). Following the WRITE Mode Control Bit
(R/W=0) and the Acknowledge Bit, the word address 'An' is written to the on-chip address pointer.
Next the START condition and slave address are
repeated followed by the READ Mode Control Bit
(R/W=1). At this point the master transmitter becomes the master receiver. The data byte which
was addressed will be transmitted and the master
receiver will send an Acknowledge Bit to the slave
transmitter. The address pointer is only incremented on reception of an Acknowledge Clock. The
M41T81 slave transmitter will now place the data
byte at address An+1 on the bus, the master receiver reads and acknowledges the new byte and
the address pointer is incremented to “An+2.”
This cycle of reading consecutive addresses will
continue until the master receiver sends a STOP
condition to the slave transmitter.
The system-to-user transfer of clock data will be
halted whenever the address being read is a clock
address (00h to 07h). The update will resume due
to a Stop Condition or when the pointer increments
to any non-clock address (08h-13h).
Note: This is true both in READ Mode and WRITE
Mode.
An alternate READ Mode may also be implemented whereby the master reads the M41T81 slave
without first writing to the (volatile) address pointer. The first address that is read is the last one
stored in the pointer (see Figure 15, page 13).
Figure 13. Slave Address Location
R/W
START
A
1
LSB
MSB
SLAVE ADDRESS
1
0
1
0
0
0
AI00602
SLAVE
ADDRESS
DATA n+1
ACK
DATA n
ACK
S
ACK
BUS ACTIVITY:
R/W
START
WORD
ADDRESS (An)
ACK
S
R/W
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 14. READ Mode Sequence
STOP
SLAVE
ADDRESS
P
NO ACK
DATA n+X
12/28
AI00899
M41T81
STOP
SLAVE
ADDRESS
P
NO ACK
BUS ACTIVITY:
DATA n+X
ACK
DATA n+1
ACK
DATA n
ACK
S
ACK
SDA LINE
R/W
BUS ACTIVITY:
MASTER
START
Figure 15. Alternative READ Mode Sequence
AI00895
WRITE Mode
In this mode the master transmitter transmits to
the M41T81 slave receiver. Bus protocol is shown
in Figure 16, page 13. Following the START condition and slave address, a logic '0' (R/W=0) is
placed on the bus and indicates to the addressed
device that word address “An” will follow and is to
be written to the on-chip address pointer. The data
word to be written to the memory is strobed in next
and the internal address pointer is incremented to
the next address location on the reception of an
acknowledge clock. The M41T81 slave receiver
will send an acknowledge clock to the master
transmitter after it has received the slave address
see Figure 13, page 12 and again after it has received the word address and each data byte.
SLAVE
ADDRESS
STOP
DATA n+X
P
ACK
DATA n+1
ACK
BUS ACTIVITY:
DATA n
ACK
WORD
ADDRESS (An)
ACK
S
R/W
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 16. WRITE Mode Sequence
AI00591
13/28
M41T81
Data Retention Mode
With valid VCC applied, the M41T81 can be accessed as described above with READ or WRITE
Cycles. Should the supply voltage decay, the power input will be switched from the VCC pin to the
battery when VCC falls below the Battery Back-up
Switchover Voltage (VSO). At this time the clock
registers will be maintained by the attached battery supply. As VCC continues to fall, the M41T81
will pass through the Register Bit Reset Voltage
(VRST) threshold, not only write protecting itself,
but also resetting certain Control Bits (see Table
13, page 21). On power-up, when VCC returns to a
nominal value, write protection continues for tREC.
For a further, more detailed review of lifetime calculations, please see Application Note AN1012.
Figure 17. Power Down/Up Mode AC Waveforms
VCC
VSO
tPD
tREC
SDA
SCL
DON'T CARE
AI00596
Table 8. Power Down/Up AC Characteristics
Parameter(1,2)
Symbol
tPD
tREC
Min
Typ
Max
Unit
SCL and SDA at VIH before Power Down
0
nS
SCL and SDA at VIH after Power Up
10
µS
Note: 1. VCC fall time should not exceed 5mV/µs.
2. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
Table 9. Power Down/Up Trip Points DC Characteristics
Sym
Parameter(1,2)
VSO
Battery Back-up Switchover Voltage
VRST
Register Bit Reset Voltage
Min
Typ
Max
Unit
VBAT – 0.80
VBAT – 0.50
VBAT – 0.30
V
2.0
V
1.1
Note: 1. All voltages referenced to VSS.
2. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
14/28
M41T81
CLOCK OPERATION
The 20-byte Register Map (see Table 10, page 16)
is used to both set the clock and to read the date
and time from the clock, in a binary coded decimal
format. Tenths/Hundredths of Seconds, Seconds,
Minutes, and Hours are contained within the first
four registers.
Note: A WRITE to any clock register will result in
the Tenths/Hundredths of Seconds being reset to
“00,” and Tenths/Hundredths of Seconds cannot
be written to any value other than “00.”
Bits D6 and D7 of Clock Register 03h (Century/
Hours Register) contain the CENTURY ENABLE
Bit (CEB) and the CENTURY Bit (CB). Setting
CEB to a '1' will cause CB to toggle, either from '0'
to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,'
CB will not toggle. Bits D0 through D2 of Register
04h contain the Day (day of week). Registers 05h,
06h, and 07h contain the Date (day of month),
Month and Years. The ninth clock register is the
Control Register (this is described in the Clock
Calibration section). Bit D7 of Register 01h contains the STOP Bit (ST). Setting this bit to a '1' will
cause the oscillator to stop. If the device is expected to spend a significant amount of time on the
shelf, the oscillator may be stopped to reduce current drain. When reset to a '0' the oscillator restarts
within one second.
The eight Clock Registers may be read one byte at
a time, or in a sequential block. The Control Register (Address location 08h) may be accessed independently. Provision has been made to assure
that a clock update does not occur while any of the
eight clock addresses are being read. If a clock address is being read, an update of the clock registers will be halted. This will prevent a transition of
data during the READ.
Note: When a power failure occurs, the HT Bit will
automatically be set to a '1.' This will prevent the
clock from updating the TIMEKEEPER® registers,
and will allow the user to read the exact time of the
power-down event. Resetting the HT Bit to a '0' will
allow the clock to update the TIMEKEEPER registers with the current time.
TIMEKEEPER ® Registers
The M41T81 offers 20 internal registers which
contain Clock, Alarm, Watchdog, Flag, Square
Wave and Control data. These registers are memory locations which contain external (user accessible) and internal copies of the data (usually
referred to as BiPORT™ TIMEKEEPER cells). The
external copies are independent of internal functions except that they are updated periodically by
the simultaneous transfer of the incremented internal copy. The internal divider (or clock) chain will
be reset upon the completion of a WRITE to any
clock address.
The system-to-user transfer of clock data will be
halted whenever the address being read is a clock
address (00h to 07h). The update will resume either due to a Stop Condition or when the pointer
increments to any non-clock address (08h-13h).
TIMEKEEPER and Alarm Registers store data in
BCD. Control, Watchdog and Square Wave Registers store data in Binary Format.
15/28
M41T81
Table 10. TIMEKEEPER® Register Map
Addr
D7
00h
D6
D5
D4
D3
0.1 Seconds
D2
D1
D0
Function/Range
BCD Format
0.01 Seconds
Seconds
00-99
01h
ST
10 Seconds
Seconds
Seconds
00-59
02h
0
10 Minutes
Minutes
Minutes
00-59
03h
CEB
CB
Hours (24 Hour Format)
Century/
Hours
0-1/00-23
04h
0
0
Day
01-7
05h
0
0
Date: Day of Month
Date
01-31
06h
0
0
Month
Month
01-12
Year
Year
00-99
07h
10 Hours
0
0
0
10 Date
0
Day of Week
10M
10 Years
08h
OUT
FT
S
Calibration
09h
0
BMB4
BMB3
BMB2
0Ah
AFE
SQWE
ABE
Al 10M
0Bh
RPT4
RPT5
0Ch
RPT3
HT
0Dh
RPT2
0Eh
RPT1
0Fh
WDF
AF
0
0
0
0
0
0
Flags
10h
0
0
0
0
0
0
0
0
Reserved
11h
0
0
0
0
0
0
0
0
Reserved
12h
0
0
0
0
0
0
0
0
Reserved
13h
RS3
RS2
RS1
RS0
0
0
0
0
SQW
BMB0
RB1
RB0
Watchdog
Alarm Month
Al Month
01-12
AI 10 Date
Alarm Date
Al Date
01-31
AI 10 Hour
Alarm Hour
Al Hour
00-23
Alarm 10 Minutes
Alarm Minutes
Al Min
00-59
Alarm 10 Seconds
Alarm Seconds
Al Sec
00-59
Keys: S = Sign Bit
FT = Frequency Test Bit
ST = Stop Bit
0 = Must be set to '0'
BMB0-BMB4 = Watchdog Multiplier Bits
CEB = Century Enable Bit
CB = Century Bit
OUT = Output level
ABE = Alarm in Battery Back-up Mode Enable Bit
16/28
BMB1
Control
AFE = Alarm Flag Enable Flag
RB0-RB1 = Watchdog Resolution Bits
RPT1-RPT5 = Alarm Repeat Mode Bits
WDF = Watchdog Flag (Read only)
AF = Alarm Flag (Read only)
SQWE = Square Wave Enable
RS0-RS3 = SQW Frequency
HT = Halt Update Bit
M41T81
Calibrating the Clock
The M41T81 is driven by a quartz controlled oscillator with a nominal frequency of 32,768 Hz. The
devices are tested not exceed –25 to +45 PPM
(parts per million) oscillator frequency error at
25oC, which equates to about +1.9 to –1.1 minutes
per month (see Figure 20, page 22). When the
Calibration circuit is properly employed, accuracy
improves to better than +1/–2 PPM at 25°C.
The oscillation rate of crystals changes with temperature. The M41T81 design employs periodic
counter correction. The calibration circuit adds or
subtracts counts from the oscillator divider circuit
at the divide by 256 stage, as shown in Figure 21,
page 22. The number of times pulses which are
blanked (subtracted, negative calibration) or split
(added, positive calibration) depends upon the
value loaded into the five Calibration Bits found in
the Control Register. Adding counts speeds the
clock up, subtracting counts slows the clock down.
The Calibration Bits occupy the five lower order
bits (D4-D0) in the Control Register 08h. These
bits can be set to represent any value between 0
and 31 in binary form. Bit D5 is a Sign Bit; '1' indicates positive calibration, '0' indicates negative
calibration. Calibration occurs within a 64 minute
cycle. The first 62 minutes in the cycle may, once
per minute, have one second either shortened by
128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2
minutes in the 64 minute cycle will be modified; if
a binary 6 is loaded, the first 12 will be affected,
and so on.
Therefore, each calibration step has the effect of
adding 512 or subtracting 256 oscillator cycles for
every 125,829,120 actual oscillator cycles, that is
+4.068 or –2.034 PPM of adjustment per calibration step in the calibration register. Assuming that
the oscillator is running at exactly 32,768 Hz, each
of the 31 increments in the Calibration byte would
represent +10.7 or –5.35 seconds per month
which corresponds to a total range of +5.5 or –2.75
minutes per month.
Two methods are available for ascertaining how
much calibration a given M41T81 may require.
The first involves setting the clock, letting it run for
a month and comparing it to a known accurate reference and recording deviation over a fixed period
of time. Calibration values, including the number of
seconds lost or gained in a given period, can be
found in Application Note AN934, “TIMEKEEPER ® CALIBRATION.” This allows the designer to
give the end user the ability to calibrate the clock
as the environment requires, even if the final product is packaged in a non-user serviceable enclosure. The designer could provide a simple utility
that accesses the Calibration byte.
The second approach is better suited to a manufacturing environment, and involves the use of the
IRQ/FT/OUT/SQW pin. The pin will toggle at
512Hz, when the Stop Bit (ST, D7 of 01h) is '0,' the
Frequency Test Bit (FT, D6 of 08h) is '1,' the Alarm
Flag Enable Bit (AFE, D7 of 0Ah) is '0,' and the
Square Wave Enable Bit (SQWE, D6 of 0Ah) is '0'
and the Watchdog Register (09h = 0) is reset.
Any deviation from 512 Hz indicates the degree
and direction of oscillator frequency shift at the test
temperature. For example, a reading of
512.010124 Hz would indicate a +20 PPM oscillator frequency error, requiring a –10 (XX001010) to
be loaded into the Calibration Byte for correction.
Note that setting or changing the Calibration Byte
does not affect the Frequency Test output frequency.
The IRQ/FT/OUT/SQW pin is an open drain output
which requires a pull-up resistor to VCC for proper
operation. A 500-10k resistor is recommended in
order to control the rise time. The FT Bit is cleared
on power-down.
17/28
M41T81
Setting Alarm Clock Registers
Address locations 0Ah-0Eh contain the alarm settings. The alarm can be configured to go off at a
prescribed time on a specific month, date, hour,
minute, or second or repeat every year, month,
day, hour, minute, or second. It can also be programmed to go off while the M41T81 is in the battery back-up mode to serve as a system wake-up
call.
Bits RPT5-RPT1 put the alarm in the repeat mode
of operation. Table 11, page 19 shows the possible configurations. Codes not listed in the table default to the once per second mode to quickly alert
the user of an incorrect alarm setting.
When the clock information matches the alarm
clock settings based on the match criteria defined
by RPT5-RPT1, the AF (Alarm Flag) is set. If AFE
(Alarm Flag Enable) is also set (and SQWE is '0.'),
the alarm condition activates the IRQ/FT/OUT/
SQW pin.
Note: If the address pointer is allowed to increment to the Flag Register address, an alarm condition will not cause the Interrupt/Flag to occur until
the address pointer is moved to a different address. It should also be noted that if the last address written is the “Alarm Seconds,” the address
pointer will increment to the Flag address, causing
this situation to occur.
The IRQ/FT/OUT/SQW output is cleared by a
READ to the Flags Register as shown in Figure
18. A subsequent READ of the Flags Register is
necessary to see that the value of the Alarm Flag
has been reset to '0.'
The IRQ/FT/OUT/SQW pin can also be activated
in the battery back-up mode. The IRQ/FT/OUT/
SQW will go low if an alarm occurs and both ABE
(Alarm in Battery Back-up Mode Enable) and AFE
are set. Figure 19 illustrates the back-up mode
alarm timing.
Figure 18. Alarm Interrupt Reset Waveform
0Eh
0Fh
10h
ACTIVE FLAG
HIGH-Z
IRQ/FT/OUT/SQW
AI04617
Figure 19. Back-up Mode Alarm Waveform
VCC
VSO
tREC
ABE and AFE Bits
AF Bit in Flags
Register
IRQ/FT/OUT/SQW
HIGH-Z
HIGH-Z
AI05663
18/28
M41T81
Table 11. Alarm Repeat Modes
RPT5
RPT4
RPT3
RPT2
RPT1
Alarm Setting
1
1
1
1
1
Once per Second
1
1
1
1
0
Once per Minute
1
1
1
0
0
Once per Hour
1
1
0
0
0
Once per Day
1
0
0
0
0
Once per Month
0
0
0
0
0
Once per Year
Watchdog Timer
The watchdog timer can be used to detect an outof-control microprocessor. The user programs the
watchdog timer by setting the desired amount of
time-out into the Watchdog Register, address 09h.
Bits BMB4-BMB0 store a binary multiplier and the
two lower order bits RB1-RB0 select the resolution, where 00 = 1/16 second, 01 = 1/4 second,
10 = 1 second, and 11 = 4 seconds. The amount
of time-out is then determined to be the multiplication of the five-bit multiplier value with the resolution. (For example: writing 00001110 in the
Watchdog Register = 3*1, or 3 seconds). If the
processor does not reset the timer within the specified period, the M41T81 sets the WDF (Watchdog
Flag) and generates a watchdog interrupt.
The watchdog timer can be reset by having the microprocessor perform a WRITE of the Watchdog
Register. The time-out period then starts over.
Should the watchdog timer time-out, a value of
00h needs to be written to the Watchdog Register
in order to clear the IRQ/FT/OUT/SQW pin. This
will also disable the watchdog function until it is
again programmed correctly. A READ of the Flags
Register will reset the Watchdog Flag (Bit D7;
Register 0Fh).
The watchdog function is automatically disabled
upon power-up and the Watchdog Register is
cleared. If the watchdog function is set, the frequency test function is activated, and the SQWE
Bit is '0,' the watchdog function prevails and the
frequency test function is denied.
19/28
M41T81
Square Wave Output
The M41T81 offers the user a programmable
square wave function which is output on the SQW
pin. RS3-RS0 bits located in 13h establish the
square wave output frequency. These frequencies
are listed in Table 12. Once the selection of the
SQW frequency has been completed, the IRQ/FT/
OUT/SQW pin can be turned on and off under software control with the Square Wave Enable Bit
(SQWE) located in Register 0Ah.
Table 12. Square Wave Output Frequency
Square Wave Bits
20/28
Square Wave
RS3
RS2
RS1
RS0
Frequency
Units
0
0
0
0
None
-
0
0
0
1
32.768
kHz
0
0
1
0
8.192
kHz
0
0
1
1
4.096
kHz
0
1
0
0
2.048
kHz
0
1
0
1
1.024
kHz
0
1
1
0
512
Hz
0
1
1
1
256
Hz
1
0
0
0
128
Hz
1
0
0
1
64
Hz
1
0
1
0
32
Hz
1
0
1
1
16
Hz
1
1
0
0
8
Hz
1
1
0
1
4
Hz
1
1
1
0
2
Hz
1
1
1
1
1
Hz
M41T81
Century Bit
Bits D7 and D6 of Clock Register 03h contain the
CENTURY ENABLE Bit (CEB) and the CENTURY
Bit (CB). Setting CEB to a '1' will cause CB to toggle, either from a '0' to '1' or from '1' to '0' at the turn
of the century (depending upon its initial state). If
CEB is set to a '0,' CB will not toggle.
Output Driver Pin
When the FT Bit, AFE Bit, SQWE Bit, and Watchdog Register are not set, the IRQ/FT/OUT/SQW
pin becomes an output driver that reflects the contents of D7 of the Control Register. In other words,
when D7 (OUT Bit) and D6 (FT Bit) of address lo-
cation 08h are a '0,' then the IRQ/FT/OUT/SQW
pin will be driven low.
Note: The IRQ/FT/OUT/SQW pin is an open drain
which requires an external pull-up resistor.
Preferred Initial Power-on Default
Upon initial application of power to the device, the
following register bits are set to a '0' state: Watchdog Register; AFE; ABE; SQWE; and FT. The following bits are set to a '1' state: ST; OUT; and HT
(see Table 13, page 21).
Table 13. Preferred Default Values
Condition
Initial Power-up(2)
Subsequent Power-up (with battery
back-up)(3)
ST
HT
Out
FT
AFE
SQWE
ABE
WATCHDOG
Register(1)
1
1
1
0
0
0
0
0
UC
1
UC
0
UC
UC
UC
0
Note: 1. BMB0-BMB4, RB0, RB1.
2. State of other control bits undefined.
3. UC = Unchanged
21/28
M41T81
Figure 20. Crystal Accuracy Across Temperature
Frequency (ppm)
20
0
–20
–40
–60
–80
–100
∆F = -0.038 ppm (T - T )2 ± 10%
0
F
C2
–120
T0 = 25 °C
–140
–160
–40
–30
–20
–10
0
10
20
30
40
50
60
70
80
Temperature °C
AI00999
Figure 21. Clock Calibration
NORMAL
POSITIVE
CALIBRATION
NEGATIVE
CALIBRATION
AI00594B
22/28
M41T81
PACKAGE MECHANICAL INFORMATION
Figure 22. SO8 – 8-lead Plastic Small Package Outline
h x 45˚
A2
A
C
B
ddd
e
D
8
E
H
1
A1
α
L
SO-A
Note: Drawing is not to scale.
Table 14. SO8 – 8-lead Plastic Small Outline (150 mils body width), Package Mechanical Data
mm
inches
Symb
Typ
Min
Max
A
1.35
A1
Min
Max
1.75
0.053
0.069
0.10
0.25
0.004
0.010
A2
1.10
1.65
0.043
0.065
B
0.33
0.51
0.013
0.020
C
0.19
0.25
0.007
0.010
D
4.80
5.00
0.189
0.197
E
3.80
4.00
0.150
0.157
–
–
–
–
H
5.80
6.20
0.228
0.244
h
0.25
0.50
0.010
0.020
L
0.40
0.90
0.016
0.035
α
0°
8°
0°
8°
N
8
e
ddd
1.27
Typ
0.050
8
0.10
0.004
23/28
M41T81
Figure 23. SOX18 – 18-lead Plastic Small Outline, 300mils, Embedded Crystal, Package Outline
D
9
h x 45°
1
C
E
10
H
18
A2
A
B
ddd
A1
e
A1
α
L
SO-J
Note: Drawing is not to scale.
Table 15. SOX18 – 18-lead Plastic Small Outline, 300mils, Embedded Crystal, Package Mechanical
Symbol
millimeters
Min
Max
Min
Max
A
2.44
2.69
0.096
0.106
A1
0.15
0.31
0.006
0.012
A2
2.29
2.39
0.090
0.094
B
0.41
0.51
0.016
0.020
C
0.20
0.31
0.008
0.012
11.56
11.66
0.455
0.459
D
Typ
11.61
ddd
e
Typ
0.457
0.10
E
24/28
inches
7.57
1.27
0.004
7.67
0.298
0.050
0.302
–
–
–
–
H
10.16
10.52
0.400
0.414
L
0.51
0.81
0.020
0.032
α
0°
8°
0°
8°
N
18
18
M41T81
Figure 24. SOX28 – 28-lead Plastic Small Outline, 300mils, Embedded Crystal, Package Outline
D
14
h x 45°
1
C
E
15
H
28
A2
A
B
ddd
A1
e
A1
α
L
SO-E
Note: Drawing is not to scale.
Table 16. SOX28 – 28-lead Plastic Small Outline, 300mils, Embedded Crystal, Package Mechanical
Symbol
millimeters
Typ
inches
Min
Max
A
2.44
A1
Min
Max
2.69
0.096
0.106
0.15
0.31
0.006
0.012
A2
2.29
2.39
0.090
0.094
B
0.41
0.51
0.016
0.020
C
0.20
0.31
0.008
0.012
D
17.91
18.01
0.705
0.709
ddd
0.10
E
e
Typ
7.57
1.27
0.004
7.67
0.298
0.050
0.302
–
–
–
–
H
10.16
10.52
0.400
0.414
L
0.51
0.81
0.020
0.032
α
0°
8°
0°
8°
N
28
28
25/28
M41T81
PART NUMBERING
Table 17. Ordering Information Scheme
Example:
M41T
81
M
6
TR
Device Type
M41T
Supply Voltage and Write Protect Voltage
81 = VCC = 2.0 to 5.5V
Package
M = SO8
MX(1) = SOX28
MY(1) = SOX18
Temperature Range
6 = –40°C to 85°C
Shipping Method for SOIC
blank = Tubes
TR = Tape & Reel
Note: 1. The SOX28 and SOX18 packages include an embedded 32,768Hz crystal.
For a list of available options (e.g., Speed, Package) or for further information on any aspect of this device,
please contact the ST Sales Office nearest to you.
26/28
M41T81
REVISION HISTORY
Table 18. Document Revision History
Date
Rev. #
Revision Details
December 2001
1.0
First Issue
21-Jan-02
1.1
Fix table footnotes (Table 5, 6)
01-May-02
1.2
Modify reflow time and temperature footnote (Table 2)
05-Jun-02
1.3
Modify Data Retention text, Trip Points (Table 9)
10-Jun-02
1.4
Corrected Supply Voltage values (Table 2, 3)
03-Jul-02
1.5
Modify DC Characteristics, Crystal Electrical table footnotes, Preferred Default Values
(Table 5, 6, 13)
11-Oct-02
1.6
Add marketing status (Figure 3; Table 17); adjust footnotes (Figure 5; Table 5)
21-Jan-03
1.7
Add embedded crystal package option (Figure 2, 7, 24; Table 16); modified preexisting mechanical drawing (Figure 22; Table 14).
05-Mar-03
1.8
Correct dimensions (Figure 24; Table 16); remove SNAPHAT® package option
12-Sep-03
2.0
Updated disclaimer, v2.2 template; add SOX18 package (Figure 3, 6, 23; Table 17, 15)
M41T81, 41T81, T81Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial,
Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial, Serial,
Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access,
Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Access, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface,
Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface,
Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface, Interface,
Interface, Interface, Interface, Interface, Interface, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock,
Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock,
Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock,
Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock,
Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, Clock, RTC, RTC, RTC, RTC,
RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC,
RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC, RTC,
RTC, RTC, RTC, RTC, RTC, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable,
Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable, Programmable,
Programmable, Programmable, Programmable, Programmable, Programmable, Programmable Alarm, Programmable Alarm, Programmable Alarm, Programmable
Alarm, Programmable Alarm, Programmable Alarm, Programmable Alarm, Programmable Alarm, Programmable Alarm, Programmable Alarm, Alarm, Alarm, Alarm,
Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm,
Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm,
Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm,
Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm, Alarm,
Alarm, Alarm, Alarm, Alarm, Alarm, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt,
Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt,
Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt,
Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Interrupt, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog,
Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog,
Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Watchdog, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery,
Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery,
Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery, Battery,
Battery, Battery, Switchover, Switchover, Switchover, Switchover, Switchover, Switchover, Switchover, Switchover, Switchover, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Backup, Write Protect, Write Protect, Write
Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect , Write Protect, Write Protect, Write Protect,
Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Write Protect, Industrial,
Industrial, Industrial, Industrial, Industrial, Industrial, Industrial, Industrial, Industrial, Industrial, Industrial, vIndustrial, Industrial, Industrial, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC, SOIC
27/28
M41T81
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is a registered trademark of STMicroelectronics.
All other names are the property of their respective owners
© 2003 STMicroelectronics - All rights reserved
STMicroelectronics GROUP OF COMPANIES
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States
www.st.com
28/28