STMICROELECTRONICS STA506

STA506
40V 4A QUAD POWER HALF BRIDGE
1
FEATURES
■
MINIMUM INPUT OUTPUT PULSE WIDTH
DISTORTION
■
200mΩ RdsON COMPLEMENTARY DMOS
OUTPUT STAGE
■
CMOS COMPATIBLE LOGIC INPUTS
■
THERMAL PROTECTION
■
THERMAL WARNING OUTPUT
■
UNDER VOLTAGE PROTECTION
■
SHORT CIRCUIT PROTECTION
2
MULTIPOWER BCD TECHNOLOGY
PowerSO36
Table 1. Order Code
DESCRIPTION
Part Number
Package
STA506
PowerSO36
to make the output stage of a stereo All-Digital High
Efficiency (DDX™) amplifier capable to deliver 60 +
60W @ THD = 10% at Vcc 32V output power on 8Ω
load and 80W @ THD = 10% at VCC 36V on 8Ω load
in single BTL configuration. In single BTL configuration is also capable to deliver a peak of 120W @THD
= 10% at VCC = 32V on 4Ω load (t ≤1sec). The input
pins have threshold proportional to VL pin voltage.
STA506 is a monolithic quad half bridge stage in Multipower BCD Technology.
The device can be used as dual bridge or reconfigured, by connecting CONFIG pin to Vdd pin, as single
bridge with double current capability, and as half
bridge (Binary mode) with half current capability. The
device is particularly designed
Figure 1. APPLICATION CIRCUIT (Dual BTL)
+VCC
VCC1A
IN1A
29
VL
23
M3
IN1A
+3.3V
R57
10K
CONFIG
24
PWRDN
PWRDN
25
R59
10K
FAULT
27
C58
100nF
TH_WAR
26
17
16
M2
PROTECTIONS
&
LOGIC
TRI-STATE
M5
TH_WAR
28
IN1B
30
C58
100nF
C53
100nF
C60
100nF
VDD
21
22
VSS
33
VSS
34
VCCSIGN
IN2A
IN2A
GND-Reg
GND-Clean
IN2B
GND1A
12
VCC1B
M4
REGULATORS
13
GND1B
7
VCC2A
IN2B
GNDSUB
8
9
M15
31
20
19
M16
1
C32
1µF
GND2A
4
VCC2B
OUT2B
OUT2B
M14
5
8Ω
C21
100nF
C110
100nF
C109
330pF R103
6
C33
1µF
3
R100
6
C99
100nF
C23
470nF
C101
100nF
L113 22µH
OUT2A
6
R98
6
L19 22µH
OUT2A
2
32
R63
20
OUT1B
OUT1B
35
36
C20
100nF
C52
330pF
C31
1µF
11
C55
1000µF
L18 22µH
OUT1A
14
M17
VCCSIGN
C30
1µF
OUT1A
10
IN1B
VDD
15
R104
20
R102
6
C107
100nF
C108
470nF
C106
100nF
8Ω
C111
100nF
L112 22µH
GND2B
D00AU1148B
June 2004
REV. 4
1/14
STA506
Table 2. PIN FUNCTION
Pin n.
Pin Name
1
GND-SUB
2;3
OUT2B
Output Half Bridge 2B
4
VCC 2B
Positive Supply
5
GND2B
Negative Supply
6
GND2A
Negative Supply
7
VCC 2A
Positive Supply
8;9
OUT2A
Output Half Bridge 2A
10 ; 11
OUT1B
Output Half Bridge 1B
12
VCC1B
Positive Supply
13
GND1B
Negative Supply
14
GND1A
Negative Supply
15
VCC1A
Positive Supply
16 ; 17
OUT1A
Output Half Bridge 1A
18
NC
Not Connected
19
GND-clean
Logical Ground
20
GND-Reg
Ground for Regulator Vdd
21 ; 22
Vdd
5V Regulator Referred to Ground
23
VL
Logic Reference Voltage
24
CONFIG
Configuration pin
25
PWRDN
Stand-by pin
26
TRI-STATE
27
FAULT
28
TH-WAR
29
IN1A
Input of Half Bridge 1A
30
IN1B
Input of Half Bridge 1B
31
IN2A
Input of Half Bridge 2A
32
IN2B
Input of Half Bridge 2B
33 ; 34
VSS
5V Regulator Referred to +VCC
35 ; 36
VCC Sign
2/14
Description
Substrate Ground
Hi-Z pin
Fault pin advisor
Thermal warning advisor
Signal Positive Supply
STA506
Table 3. FUNCTIONAL PIN STATUS
Pin name
Pin n.
Logical value
FAULT
27
0
Fault detected (Short circuit, or Thermal ..)
27
1
Normal Operation
TRI-STATE
26
0
All powers in Hi-Z state
TRI-STATE
26
1
Normal operation
PWRDN
25
0
Low absorpion
PWRDN
25
1
Normal operation
THWAR
28
0
Temperature of the IC =130°C
THWAR(*)
28
1
Normal operation
CONFIG
24
0
Normal Operation
CONFIG(**)
24
1
OUT1A = OUT1B ; OUT2A=OUT2B
(IF IN1A = IN1B; IN2A = IN2B)
FAULT
(*) :
(**):
(*)
IC -STATUS
The pin is open collector. To have the high logic value, it needs to be pulled up by a resistor.
To put CONFIG = 1 means connect Pin 24 (CONFIG) to Pins 21, 22 (Vdd) to implement single BTL (mono mode) operation for
high current.
Figure 2. PIN CONNECTION
VCCSign
36
1
GND-SUB
VCCSign
35
2
OUT2B
VSS
34
3
OUT2B
VSS
33
4
VCC2B
IN2B
32
5
GND2B
IN2A
31
6
GND2A
IN1B
30
7
VCC2A
IN1A
29
8
OUT2A
TH_WAR
28
9
OUT2A
FAULT
27
10
OUT1B
TRI-STATE
26
11
OUT1B
PWRDN
25
12
VCC1B
CONFIG
24
13
GND1B
VL
23
14
GND1A
VDD
22
15
VCC1A
VDD
21
16
OUT1A
GND-Reg
20
17
OUT1A
GND-Clean
19
18
N.C.
D01AU1273
3/14
STA506
Table 4. ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
VCE
DC Supply Voltage (Pin 4,7,12,15)
40
V
Vmax
Maximum Voltage on pins 23 to 32 (logic reference)
5.5
V
Ptot
Power Dissipation (Tcase = 70°C)
50
W
Top
Operating Temperature Range
0 to 70
°C
-40 to 150
°C
Tstg, Tj
Storage and Junction Temperature
Table 5. (*) RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min.
DC Supply Voltage
9.0
VL
Input Logic Reference
2.7
Tamb
Ambient Temperature
0
VCC
Typ.
3.3
Max.
Unit
36.0
V
5.0
v
70
°C
(*) performances not guaranteed beyond recommended operating conditions
Table 6. THERMAL DATA
Symbol
Tj-case
Parameter
Min.
Typ.
Thermal Resistance Junction to Case (thermal pad)
Max.
Unit
1.5
°C/W
TjSD
Thermal shut-down junction temperature
150
°C
Twarn
Thermal warning temperature
130
°C
thSD
Thermal shut-down hysteresis
25
°C
Table 7. ELECTRICAL CHARACTERISTCS: refer to circuit in Fig.1 (VL = 3.3V; VCC = 32V; R L = 8Ω;
fsw = 384KHz; Tamb = 25°C unless otherwise specified)
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
Unit
200
270
mΩ
50
µA
RdsON
Power Pchannel/Nchannel
MOSFET RdsON
Id=1A
Idss
Power Pchannel/Nchannel
leakage Idss
VCC =35V
gN
Power Pchannel RdsON
Matching
Id=1A
95
%
gP
Power Nchannel RdsON
Matching
Id=1A
95
%
Dt_s
Low current Dead Time (static)
see test circuit no.1; see fig. 3
Dt_d
20
ns
High current Dead Time (dinamic) L=22µH; C = 470nF; RL = 8 Ω
Id=3.5A; see fig. 5
50
ns
td ON
Turn-on delay time
Resistive load
100
ns
td OFF
Turn-off delay time
Resistive load
100
ns
tr
Rise time
Resistive load; as fig.3
25
ns
tf
Fall time
Resistive load; as fig. 3
25
ns
36
V
VL/2
+300mV
V
VCC
Supply voltage operating voltage
VIN-H
High level input voltage
4/14
10
9
STA506
TABLE 6. ELECTRICAL CHARACTERISTCS (continued)
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
VL/2 300mV
Unit
VIN-L
Low level input voltage
IIN-H
Hi level Input current
Pin Voltage = VL
1
µA
IIN-L
Low level input current
Pin Voltage = 0.3V
1
µA
35
µA
IPWRDN-H Hi level PWRDN pin input current
VL = 3.3V
VLOW
Low logical state voltage VLow
VL = 3.3V
(pin PWRDN, TRISTATE) (note 1)
VHIGH
High logical state voltage VHigh
VL = 3.3V
(pin PWRDN, TRISTATE) (note 1)
IVCCPWRDN
Supply CURRENT from Vcc in
Power Down
IFAULT
Output Current pins
FAULT -TH-WARN when
FAULT CONDITIONS
IVCC-hiz
IVCC
IVCC-q
VOUT-SH
0.8
V
PWRDN = 0
Vpin = 3.3V
1.7
V
3
mA
1
mA
Supply Current from Vcc in Tristate
VCC = 30V; Tri-state = 0
22
mA
Supply Current from Vcc in
operation
both channel switching)
VCC =30V;
Input Pulse width = 50% Duty;
Switching Frequency = 384KHz;
No LC filters;
50
mA
Isc (short circuit current limit)
(note 2)
4
Undervoltage protection threshold
Output minimum pulse width
VOV
V
6
8
A
7
No Load
70
V
150
ns
Notes: 1. The following table explains the VLOW, VHIGH variation with VL
Table 8.
VL
VLOW min
VHIGH max
Unit
2.7
0.7
1.5
V
3.3
0.8
1.7
V
5
0.85
1.85
V
Note 2: See relevant Application Note AN1994
Table 9. LOGIC TRUTH TABLE (see fig. 4)
TRI-STATE
INxA
INxB
Q1
Q2
Q3
Q4
OUTPUT
MODE
0
x
x
OFF
OFF
OFF
OFF
Hi-Z
1
0
0
OFF
OFF
ON
ON
DUMP
1
0
1
OFF
ON
ON
OFF
NEGATIVE
1
1
0
ON
OFF
OFF
ON
POSITIVE
1
1
1
ON
ON
OFF
OFF
Not used
5/14
STA506
Figure 3. Test Circuit.
OUTxY
Vcc
(3/4)Vcc
Low current dead time = MAX(DTr,DTf)
(1/2)Vcc
(1/4)Vcc
+Vcc
t
DTr
Duty cycle = 50%
DTf
M58
OUTxY
INxY
R 8Ω
M57
+
-
gnd
V67 =
vdc = Vcc/2
D03AU1458
Figure 4.
+VCC
Q1
Q2
OUTxA
INxA
OUTxB
Q3
INxB
Q4
GND
D00AU1134
Figure 5.
High Current Dead time for Bridge application = ABS(DTout(A)-DTin(A))+ABS(DTOUT(B)-DTin(B))
+VCC
Duty cycle=A
Duty cycle=B
DTout(A)
M58
DTin(A)
Q1
Q2
Rload=8Ω
OUTA
INA
Iout=4A
M57
Q3
DTout(B)
L67 22µ
C69
470nF
L68 22µ
C71 470nF
C70
470nF
DTin(B)
OUTB
INB
Iout=4A
Q4
Duty cycle A and B: Fixed to have DC output current of 4.5A in the direction shown in figure
6/14
M64
M63
D03AU1517
STA506
3
TECHNICAL INFO:
The STA506 is a dual channel H-Bridge that is able to deliver more than 60W per channel (@ THD=10%) of
audio output power in high efficiency.
The STA506 converts both DDX and binary-controlled PWM signals into audio power at the load. It includes a
logic interface , integrated bridge drivers, high efficiency MOSFET outputs and thermal and short circuit protection circuitry.
In DDX mode, two logic level signals per channel are used to control high-speed MOSFET switches to connect
the speaker load to the input supply or to ground in a Bridge configuration, according to the damped ternary
Modulation operation.
In Binary Mode operation , both Full Bridge and Half Bridge Modes are supported. The STA506 includes overcurrent and thermal protection as well as an under-voltage
Lockout with automatic recovery. A thermal warning status is also provided.
Figure 6. STA506 Block Diagram Full-Bridge DDX® or Binary Modes
INL[1:2]
INR[1:2]
VL
OUTPL
Logic I/F
and Decode
Left
H-Bridge
PWRDN
OUTNL
TRI-STATE
FAULT
TWARN
Protection
Circuitry
OUTPR
Right
H-Bridge
Regulators
OUTNR
Figure 7. STA506 Block Diagram Binary Half-Bridge Mode
LeftA
‰-Bridge
OUTPL
LeftB
‰-Bridge
OUTNL
Protection
Circuitry
RightA
‰-Bridge
OUTPR
Regulators
RightB
‰-Bridge
OUTNR
INL[1:2]
INR[1:2]
VL
Logic I/F
and Decode
PWRDN
TRI-STATE
FAULT
TWARN
3.1 Logic Interface and Decode:
The STA506 power outputs are controlled using one or two logic level timing signals. In order to provide a proper
logic interface, the Vbias input must operate at the dame voltage as the DDX control logic supply.
3.2 Protection Circuitry:
The STA506 includes protection circuitry for over-current and thermal overload conditions. A thermal warning
pin (pin.28) is activated low (open drain MOSFET) when the IC temperature exceeds 130C, in advance of the
thermal shutdown protection. When a fault condition is detected , an internal fault signal acts to immediately
disable the output power MOSFETs, placing both H-Bridges in high impedance state. At the same time an opendrain MOSFET connected to the fault pin (pin.27) is switched on.
7/14
STA506
There are two possible modes subsequent to activating a fault:
– 1) SHUTDOWN mode: with FAULT (pull-up resistor) and TRI-STATE pins independent, an activated
fault will disable the device, signaling low at the FAULT output.
The device may subsequently be reset to normal operation by toggling the TRI-STATE pin from
High to Low to High using an external logic signal.
– 2) AUTOMATIC recovery mode: This is shown in the Application Circuit of fig.1.
The FAULT and TRI-STATE pins are shorted together and connected to a time constant circuit comprising R59 and C58.
An activated FAULT will force a reset on the TRI-STATE pin causing normal operation to resume following a delay determined by the time constant of the circuit.
If the fault condition is still present , the circuit operation will continue repeating until the fault condition
is removed .
An increase in the time constant of the circuit will produce a longer recovery interval. Care must be
taken in the overall system design as not to exceed the protection thesholds under normal operation.
3.3 Power Outputs:
The STA506 power and output pins are duplicated to provide a low impedance path for the device's bridged
outputs .
All duplicate power, ground and output pins must be connected for proper operation.
The PWRDN or TRI-STATE pins should be used to set all MOSFETS to the Hi-Z state during power-up until the
logic power supply, VL , is settled.
3.4 Parallel Output / High Current Operation:
When using DDX Mode output , the STA506 outputs can be connected in parallel in order to increase the output
current capability to a load.
In this configuration the STA506 can provide 80W into 8 ohm or up to 120W into 4ohm.
This mode of operation is enabled with the CONFIG pin (pin.24) connected to VREG1 and the inputs combined
INLA=INLB, INRA=INRB and the outputs combined OUTLA=OTLB, OUTRA=OUTRB.
3.5 Additional Informations:
Output Filter: A passive 2nd-order passive filter is used on the STA506 power outputs to reconstruct an analog
Audio Signal .
System performance can be significantly affected by the output filter design and choice of passive components.
A filter design for 6ohm/8ohm loads is shown in the Typical Application circuit of fig.1. Figure 9 shows a filter
design suitable for 4ohm loads.
Figure 10 shows a filter for ½ bridge mode , 4 ohm loads.
Power Dissipation & Heat Sink requirements: The power dissipated within the device will depend primarily
on the supply voltage, load impedance and output modulation level.
The PowerSO36 package of the STA506 includes an exposed thermal slug on the top of the device to provide
a direct thermal path from the IC to the heatsink.
Careful consideration must be given to the overall thermal design . See figure 8 for power derating
versus Slug temperature using different heatsinks and considering the Rth-jc =1.5°C/W.
8/14
STA506
Figure 8. STA506 power derating curve
60
Pdiss(W)
1 –Infinite
2- 1.5C/W
3- 3 C/W
4- 4 C/W
1
50
40
2
30
3
20
4
10
0
0
20
40
60
80
100
120
140
160
Slug temperature C°
Figure 9. Typical Single BTL Configurationto obtain 120W @ THD 10%, RL = 4Ω, VCC = 32V (note 1))
VL
+3.3V
GND-Clean
GND-Reg
10K
23
18
N.C.
10µH
100nF
100nF
X7R
VDD
VDD
CONFIG
TH_WAR
TH_WAR
PWRDN
nPWRDN
10K
FAULT
IN1A
IN1B
IN1A
IN2A
IN2B
IN1B
VSS
VSS
100nF
X7R
20
21
22
24
28
25
27
TRI-STATE
100nF
19
VCCSIGN
100nF
X7R
VCCSIGN
Add.
GNDSUB
26
29
17
16
11
10
OUT1B
OUT1B
OUT2A
8
34
22Ω
1/2W
6.2
1/2W
330pF
6.2
1/2W
OUT2B
3
15
12
7
4
100nF
X7R
470nF
FILM
100nF
X7R
4Ω
100nF
FILM
OUT2B
2
10µH
VCC1A
VCC1B
32V
1µF
X7R
VCC2A
32
33
100nF
FILM
OUT1A
OUT2A
9
30
31
OUT1A
VCC2B
2200µF
63V
32V
1µF
X7R
GND1A
14
GND1B
35
13
36
6
1
5
GND2A
GND2B
D03AU1514
Note: 1. "A PWM modulator as driver is needed . In particular, this result is performed using the STA30X+STA50X demo board". Peak Power for t ≤1sec
9/14
STA506
Figure 10. Typical Quad Half Bridge Configuration
+VCC
VCC1P
IN1A
29
M3
IN1A
+3.3V
PWRDN
R57
10K
R59
10K
C58
100nF
TH_WAR
VL
23
CONFIG
24
PWRDN
FAULT
16
26
M2
PROTECTIONS
&
LOGIC
TRI-STATE
M5
TH_WAR
28
IN1B
30
VDD
21
VDD
22
VSS
33
VSS
34
C53
100nF
C60
100nF
IN2A
GND-Reg
GND-Clean
IN2B
PGND1P
12
VCC1N
C51
1µF
REGULATORS
13
7
C41
330pF
PGND1N
VCC2P
C71
100nF
R51
6
IN2B
GNDSUB
R42
20
C42
330pF
C72
100nF
R52
6
C82
100nF
9
36
M15
31
20
19
M16
6
PGND2P
4
VCC2N
3
2
32
1
OUTPR
C52
1µF
5
C43
330pF
PGND2N
C73
100nF
R53
6
C83
100nF
C62
100nF
OUTNR
OUTNR
M14
R43
20
C44
330pF
R66
5K
R67
5K
L14 22µH
R44
20
R64
5K
R65
5K
L13 22µH
OUTPR
R62
5K
R63
5K
L12 22µH
8
35
D03AU1474
C74
100nF
R54
6
For more information refer to the application notes AN1456 and AN1661
10/14
C81
100nF
C61
100nF
OUTNL
OUTNL
M4
R41
20
M17
VCCSIGN
VCCSIGN
IN2A
14
10
IN1B
C58
100nF
OUTPL
OUTPL
11
R61
5K
L11 22µH
17
25
27
15
C84
100nF
R68
5K
C21
2200µF
C31 820µF
C91
1µF
4Ω
C32 820µF
C92
1µF
4Ω
C33 820µF
C93
1µF
4Ω
C34 820µF
C94
1µF
4Ω
STA506
The following measures are related to the application using STA308A driver
Figure 11. THD+N vs Frequency
Figure 14. THD+N vs Output Power
1
T
THD(%) 10
5
0.5
Vcc=32V
Rl=8ohm
2
Vcc=36V
Rl=8ohm
0.2
1
F=1KHz
0.5
%
0.1
0.2
0.05
0.1
0.05
0.02
0.02
0.01
20
50
100
200
500
1k
2k
5k
10k
20k
0.01
100m
200m
500m
1
2
Hz
5
10
20
50 80
Pout(W)
Figure 12. Output Power vs Vsupply
Table 10. THD+N vs Output PowerRevision
THD(%) 10
Po(W) 80
5
70
Rl=8ohm
60
2
Vcc=32V
Rl=8ohm
F=1KHz
1
THD=10%
F=1KHz
50
0.5
40
0.2
30
0.1
20
0.05
THD=1%
10
0.02
0.01
+14
+16
+18
+20
+22
+24
+26
+28
+30
+32
+34 +36
Vsupply(V)
100m
200m
500m
1
2
5
10
20
50 80
Pout(W)
Figure 13. THD+N vs Output Power
THD(%)
10
5
2
Vcc=34V
Rl=8ohm
1
F=1KHz
0.5
0.2
0.1
0.05
0.02
0.01
100m
200m
500m
1
2
5
10
20
50 80
Pout(W)
11/14
STA506
DIM.
A
A2
A4
A5
a1
b
c
D
D1
D2
E
E1
E2
E3
E4
e
e3
G
H
h
L
N
s
MIN.
3.25
3.1
0.8
mm
TYP.
MAX.
3.43
3.2
1
MIN.
0.128
0.122
0.031
-0.040
0.38
0.32
16
9.8
0.0011
0.008
0.009
0.622
0.37
14.5
11.1
2.9
6.2
3.2
0.547
0.429
0.2
0.030
0.22
0.23
15.8
9.4
5.8
2.9
0.8
OUTLINE AND
MECHANICAL DATA
-0.0015
0.015
0.012
0.630
0.38
0.039
0.57
0.437
0.114
0.244
1.259
0.228
0.114
0.65
11.05
0
15.5
MAX.
0.135
0.126
0.039
0.008
1
13.9
10.9
inch
TYP.
0.026
0.435
0.075
0
15.9
0.61
1.1
1.1
0.031
10˚ (max)
8˚ (max)
0.003
0.625
0.043
0.043
(1) “D and E1” do not include mold flash or protusions.
Mold flash or protusions shall not exceed 0.15mm (0.006”)
(2) No intrusion allowed inwards the leads.
PowerSO36 (SLUG UP)
7183931 C
12/14
STA506
Table 11. History
Date
Revision
Description of Changes
December 2003
1
First Issue
April 2004
2
Inserted Technical Info and Graphics
April 2004
3
Small changes in pag 4 and 5
June 2004
4
Note 2: See relevant Application Note AN1994
13/14
STA506
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is a registered trademark of STMicroelectronics.
All other names are the property of their respective owners
© 2004 STMicroelectronics - All rights reserved
STMicroelectronics GROUP OF COMPANIES
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States
www.st.com
14/14