file: tfs111b.doc 26.02.2002 version 2.0 VI TELEFILTER Filter specification TFS 111B 1/5 Measurement condition Ambient temperature: 23°C Input power level: 0dBm Terminating impedances *) for input: 3,2 kΩ ||- 5,6pF for output: 3,1 kΩ || -6.2pF Characteristics Remark: The reference level for the relative attenuation arel of TFS 111B is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20,0 dB filter attenuation level relative to the insertion loss ae. Data typ. value Insertion loss (reference level) ae = amin Centre frequency fc (30 dB-BW) 7 111 tolerance / limit dB 11 MHz ± 60 dB kHz Relative attenuation arel fc - 500 kHz ... fc + 500 kHz 1 dB max. 2 dB fc ± fc ± fc ± MHz MHz MHz 22 33 45 dB dB dB min. min. min. 20 30 40 dB dB dB 300 ns max 500 ns 1 2 3 MHz ... fc ± 2 MHz ... fc ± 3 MHz ... fc ± 10 **) Group delay Ripple fc ± 500 kHz GD Temperature coefficient TC 2nd order **) Frequency inversion temperature To - 0,032 ppm/K² 25 Operating temperature range Storage temperature range Input power level - °C - 10 °C ... + 60 °C - 40 °C ... + 85 °C - max. + 10 dBm *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) - ∆f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz) Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs111b.doc 26.02.2002 version 2.0 VI TELEFILTER Filter specification TFS 111B 2/5 Construction and pin connection (All dimensions in mm) S 111 B P09 3 2 Ma x. 1 5,2 Ma x. 2,54 +-0,2 7,2 Ma x. 2,54+-0,2 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground Datecode: M N P ... Year+week 2000 2001 2002 0,8 50 Ω test circuit L2 L1 10 Input 4 Input SAW 50 Ohm C1 50 Ohm C2 1,2,3,5,6,7, 8,9,11,12 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs111b.doc 26.02.2002 version 2.0 VI TELEFILTER Filter specification TFS 111B 3/5 Stability Characteristics: After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 temperature: -55 °C to 125°C / 30 min each. / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing: Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : 0,6 P2 : 2 ± 0,1 P1 : 8 ± 0,1 D1(min) : Ao : Bo : Ct : 1,5 5,5 ± 0,1 7,5 ± 0,1 13,5+/-0,1 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 W Bo Ct G P1 COVER TAPE W2 Reel (all dimensions in mm): A : 330 W1 : W 2 (max) : 16,4 +2 22,4 N (min) : 50 C : 13 + 0,5 - 0,2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs111b.doc 26.02.2002 version 2.0 VI TELEFILTER Filter specification TFS 111B 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs111b.doc 26.02.2002 VI TELEFILTER version 2.0 Filter specification TFS 111B 5/5 History Version Reason of Changes Development specification 1.1. - passband ripple: 3dB Î 1.5 dB - new datecode introduced and explained 1.2. - complete specification - passband ripple, group delay ripple, attenuation at fc+-1MHz changed according to agreements with customer Filter specification 2.0 - typical values and terminating impedance added Name Date Steiner 08.05.2000 Steiner 28.07.2000 Steiner 26.02.2002 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.