VECTRON TFS125H

tfs125H.doc
version 1.2
VI TELEFILTER
Filter specification
18.06.2003
TFS 125 H
1/5
Measurement Condition
Ambient temperature:
Input power level:
Source impedance:
Load impedance:
Terminating impedances: *)
23
0
50
50
input:
output:
C
dBm
single ended
single ended
1,03 k // -15,4 pF
0,88 k // -14,8 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 125H is the minimum of the pass band attenuation. Reference for the echo
response attenuation is the main time response lobe, the reference time is defined as t0. The nominal frequency fN is fixed at 125 MHz without
tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even
if the centre frequency fc is shifted due to the temperature coefficient of frequency TC f in the operating temperature range and due to a
production tolerance for the centre frequency fc.
Data
typ. Value
8
Absolute attenuation within PB
Nominal frequency
fN
Limit
dB
7... 10
-
125
dB
MHz
Pass band (PB)
-
fN
0,6 MHz
1 dB bandwidth
1,6 MHz
min.
1,2 MHz
-
max.
max.
max.
0,4 dB
0,7 dB
1,85 dB
Relative attenuation
fN
... fN
0,1 MHz ... fN
fN
fN
0,4 MHz ... fN
1,2
fN
1,8
fN
fN
6
fN - 13
fN + 13
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
arel
0,1 MHz
0,4 MHz
0,6 MHz
fN 1,8
fN
6
fN
13
fN - 115
fN + 325
MHz
MHz
MHz
MHz
MHz
Echo response attenuation arel
t0 +
2
µs
t0 +
3
µs
t0 +
4
µs
t0 +
5
µs
t0 +
6
µs
Group delay
at fN
Group delay ripple within PB
7
22
45
65
70
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
6
15
40
50
50
dB
dB
dB
dB
dB
37
46
56
65
78
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
30
40
50
55
60
dB
dB
dB
dB
dB
700
50
ns
ns
max. 800
max. 150
ns
ns
max. + 10
dBm
-
Input power level
14
dB
min.
Intermodulation products **
70
dBm
min.
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Frequency inversion temperature
-0,04
20
VSWR
within PB
TCf ***
T0
ppm/K
°C
2
2:1
60
dBm
- 10 °C ... + 85 °C
- 40 °C ... + 125 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) fin,1=125MHz; fin,2=125,1MHz; Pin=4dBm+loss at fN; fout,1=124,9MHz; fout,2=125,2MHz; then Pout <-56dBm
***) f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125H.doc
version 1.2
VI TELEFILTER
Filter specification
TFS 125 H
18.06.2003
2/5
Construction and pin configuration
(all dimensions in mm)
8
9
9,3 Max.
7
6
5
TFS 125H
10
4
R25
1
2
1
2
3
4
5
6
7
8
9
10
3
Date code
2,54 ±0,12,54 ±0,1
0,10
2
3
1
ground
ground
ground
output
ground
ground
ground
ground
ground
input
date code:
N
P
R
year + week
2001
2002
2003
....
....
4
10
9
5
8
7
0,8
7,1
6
Matching circuit:
L1
L2
10
Input
50 Ohm
4
Output
50 Ohm
SAW
C1
C2
1,2,3,5,6,7,8,9
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125H.doc
version 1.2
VI TELEFILTER
Filter specification
18.06.2003
TFS 125 H
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
Tape (all dim ensions in mm)
W
Po
:
:
16
4
Do
E
F
:
:
:
1,5 + 0,1
1,75 ± 0,1
7,5 ± 0,1
0,60
2 ± 0,1
8 ± 0,1
1,5
5,30 ± 0,1
9,70 ± 0,1
CT
13,5
:
EMBOSSED CARR IER TAPE
± 0,3
± 0,1
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
Bo
:
3000
min 300 mm
min 500 mm
min 300 mm
Do
Po
P2
E
Ao
F
D1
± 0,1
W
Bo
CT
G
P1
COVER TAPE
W2
Reel (all dimensions in mm):
A
W1
W2(max)
N(min)
C
:
:
:
:
:
330
16,4 + 2
22,4
50
13,0 + 0,5 / - 0,2
A
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125H.doc
version 1.2
VI TELEFILTER
Filter specification
18.06.2003
TFS 125 H
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125H.doc
version 1.2
VI TELEFILTER
Filter specification
18.06.2003
TFS 125 H
5/5
History
Version
Reason of Changes
Name
Date
Development specification
1.0
generation of development specification
Pfeiffer
24.01.2003
1.1
typical values and terminating impedance added
Pfeiffer
24.04.2003
1.2
absolute group delay and inband mask changed according customer specification
versions 1.0.4 and 2.0.0
Pfeiffer
18.06.2003
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.