tfs125H.doc version 1.2 VI TELEFILTER Filter specification 18.06.2003 TFS 125 H 1/5 Measurement Condition Ambient temperature: Input power level: Source impedance: Load impedance: Terminating impedances: *) 23 0 50 50 input: output: C dBm single ended single ended 1,03 k // -15,4 pF 0,88 k // -14,8 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 125H is the minimum of the pass band attenuation. Reference for the echo response attenuation is the main time response lobe, the reference time is defined as t0. The nominal frequency fN is fixed at 125 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TC f in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. Value 8 Absolute attenuation within PB Nominal frequency fN Limit dB 7... 10 - 125 dB MHz Pass band (PB) - fN 0,6 MHz 1 dB bandwidth 1,6 MHz min. 1,2 MHz - max. max. max. 0,4 dB 0,7 dB 1,85 dB Relative attenuation fN ... fN 0,1 MHz ... fN fN fN 0,4 MHz ... fN 1,2 fN 1,8 fN fN 6 fN - 13 fN + 13 MHz ... MHz ... MHz ... MHz ... MHz ... arel 0,1 MHz 0,4 MHz 0,6 MHz fN 1,8 fN 6 fN 13 fN - 115 fN + 325 MHz MHz MHz MHz MHz Echo response attenuation arel t0 + 2 µs t0 + 3 µs t0 + 4 µs t0 + 5 µs t0 + 6 µs Group delay at fN Group delay ripple within PB 7 22 45 65 70 dB dB dB dB dB min. min. min. min. min. 6 15 40 50 50 dB dB dB dB dB 37 46 56 65 78 dB dB dB dB dB min. min. min. min. min. 30 40 50 55 60 dB dB dB dB dB 700 50 ns ns max. 800 max. 150 ns ns max. + 10 dBm - Input power level 14 dB min. Intermodulation products ** 70 dBm min. Operating temperature range Storage temperature range Temperature coefficient of frequency Frequency inversion temperature -0,04 20 VSWR within PB TCf *** T0 ppm/K °C 2 2:1 60 dBm - 10 °C ... + 85 °C - 40 °C ... + 125 °C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) fin,1=125MHz; fin,2=125,1MHz; Pin=4dBm+loss at fN; fout,1=124,9MHz; fout,2=125,2MHz; then Pout <-56dBm ***) f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) generated: checked / approved: TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125H.doc version 1.2 VI TELEFILTER Filter specification TFS 125 H 18.06.2003 2/5 Construction and pin configuration (all dimensions in mm) 8 9 9,3 Max. 7 6 5 TFS 125H 10 4 R25 1 2 1 2 3 4 5 6 7 8 9 10 3 Date code 2,54 ±0,12,54 ±0,1 0,10 2 3 1 ground ground ground output ground ground ground ground ground input date code: N P R year + week 2001 2002 2003 .... .... 4 10 9 5 8 7 0,8 7,1 6 Matching circuit: L1 L2 10 Input 50 Ohm 4 Output 50 Ohm SAW C1 C2 1,2,3,5,6,7,8,9 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125H.doc version 1.2 VI TELEFILTER Filter specification 18.06.2003 TFS 125 H 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dim ensions in mm) W Po : : 16 4 Do E F : : : 1,5 + 0,1 1,75 ± 0,1 7,5 ± 0,1 0,60 2 ± 0,1 8 ± 0,1 1,5 5,30 ± 0,1 9,70 ± 0,1 CT 13,5 : EMBOSSED CARR IER TAPE ± 0,3 ± 0,1 G (min) : P2 : P1 : D1(min) : Ao : Bo : 3000 min 300 mm min 500 mm min 300 mm Do Po P2 E Ao F D1 ± 0,1 W Bo CT G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 W2(max) N(min) C : : : : : 330 16,4 + 2 22,4 50 13,0 + 0,5 / - 0,2 A C N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125H.doc version 1.2 VI TELEFILTER Filter specification 18.06.2003 TFS 125 H 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125H.doc version 1.2 VI TELEFILTER Filter specification 18.06.2003 TFS 125 H 5/5 History Version Reason of Changes Name Date Development specification 1.0 generation of development specification Pfeiffer 24.01.2003 1.1 typical values and terminating impedance added Pfeiffer 24.04.2003 1.2 absolute group delay and inband mask changed according customer specification versions 1.0.4 and 2.0.0 Pfeiffer 18.06.2003 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.