Filename: tfs140X.doc version 1.2 VI TELEFILTER Filter specification 24.11.2003 TFS 140X 1/5 Measurement condition Ambient temperature: Input power level: Source and load impedance: Terminating impedances * Input: Output: 25 0 50 C dBm 2 99 103 || - 28.3 pF || - 27.2 pF Characteristics Remark: The reference level for the relative attenuation a rel of TFS140X is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss a e. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme Data typ. value Insertion loss a e = amin Nominal frequency fN 9 140 dB limit max. 12 140,0 MHz dB MHz Centre frequency fc (at ambient temperature) 139,60 ... 140,40 MHz Pass band fN 7,1 MHz max. 1 dB PB Amplitude ripple (peak to adjacent valley) within fN 7,2 MHz 0.2 Bandwidth 1 dB 3 dB 17,6 18,5 MHz MHz min. min. 17 17,75 MHz MHz 35 40 21,8 24,8 MHz MHz max. max. 24 48 MHz MHz dB dB max. max. 1 3 40 50 6 dB dB deg min. min. max. 35 40 10 dB dB deg p-p 44 ns max. 60 ns 777 ns max. 825 ns max. + 10 dBm dB dB Relative attenuation fN ... fN fN 8,5 MHz ... fN a rel 12 MHz ... fN fN fN 24 MHz ... fN Phase variation within PB 8,5 MHz 8,875 MHz 24 40 0,5 1,5 MHz MHz Group delay ripple within PB Absolute group delay within PB Input power level Operable temperature range - 40 C ... + 85 C Storage temperature range Temperature coefficient of frequency *) dB dB - 40 C ... + 85 C TCf -87 ppm/K The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. Generated: Checked / approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs140X.doc version 1.2 VI TELEFILTER Filter specification 24.11.2003 TFS 140X 2/5 Construction and pin connection (All dimensions in mm) 1 2 3 4 5 6 7 8 9 10 11 12 TFS 140X R13 Datecode Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: Year+week N 2001 P 2002 R 2003 ...... 50 test circuit L1 11 5 L2 Input 50 Ohm Output 50 Ohm C1 SAW C2 1,2,3,4,6,7,8,9,10,12 Tele Filter GmbH Potsdamer Straße 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs140X.doc version 1.2 VI TELEFILTER 24.11.2003 Filter specification TFS 140X 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow):reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing DIN IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; Tape & Reel: max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 1700 min 300 mm min 500 mm min 300 mm Tape (all dim en sions in mm ) W : 24 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 11,5 ± 0,1 G (min) : 0,60 P2 : 2 ± 0,1 P1 : 12 ± 0,1 D1(min) : 1,5 Ao : 7,1 ± 0,2 Bo : 13,9 ± 0,2 Ct : 21,5 ± 0,1 EMBOSSED CARR IER TAPE Do Po P2 E Ao F D1 Ct W Bo G P1 COVE R TAP E W 2 Reel (all dimensions in mm): A : 330 W1 : W2 (max) : 24,40 +2,0 30,4 N (min) : 60 C : 13 ± 0,5/-0.2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. Tele Filter GmbH Potsdamer Straße 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs140X.doc version 1.2 VI TELEFILTER 24.11.2003 Filter specification TFS 140X 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs140X.doc VI TELEFILTER version 1.2 Filter specification 24.11.2003 TFS 140X 5/5 History Version Reason of Changes Name Date 1.0 generation of specification according to customer requirements E. Chilla 28.04.2003 1.1 group delay ripple changed absolute group delay added E. Chilla 21.04.2003 1.2 changed to filter specification terminating impedances added typical values added pass band added bandwidth for 1 dB, 3 dB, 35 dB changed relative attenuation changed E. Chilla 24.11.2003 Tele Filter GmbH Potsdamer Straße 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.