Tfs140F.doc Version 1.5 VI TELEFILTER Filter Specification 08.01.2001 TFS 140F - 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 25 °C 0 dBm. for input: Q-value of matching elements: for output: ≥ 50 740 Ω - 8,35 pF. 700 Ω - 9,40 pF. 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 140F is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme Data typ. value Insertion loss (Reference level) Centre frequency ae fc at ambient temperature TA (fCAT) tolerance / limit 18,5...19 dB max. 140,01 MHz 140 ± 0,06 MHz Pass band (PB) at ambient temperature TA: Amplitude ripple (p-p): Bandwidth 1 3 40 45 fC ..... fC ± 1,35 MHz 20 dB fC - 1,6 MHz.....fC + 1,6 MHz 0,5...0,7 dB max. 1 dB at ambient temperature: dB - band width dB - band width dB - band width dB - band width Relative attenuation 2,87 3,23 4,62 4,69 MHz MHz MHz MHz min. 2,70 MHz min. 3,20 MHz max. 4,70 MHz dB dB dB dB max. max. min. min. arel fC ............ fC ± 1,35 MHz ..... fC ± 2,35 MHz ..... fC ± 6 MHz ..... fC fC fC fC ± 1,35 MHz ± 1,6 MHz ± 6 MHz ± 40 MHz Group delay ( mean value in PB ): Group delay ripple in PB (p-p): Deviation from linear phase in PB (p-p): Input VSWR (S11) in PB : Output VSWR (S22) in PB : Triple transit attenuation compared to main signal Crosstalk Substrate material Frequency inversion temperature ( To ) Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature: * ) 0,6 2,5 45...50 50....70 1,69 µs 100 ns 4° ( r.m.s. 0,9° ) 1,6 : 1 1,6 : 1 41...42 dB 50...60 dB 1 3 40 45 dB dB dB dB max. 2,5 µs max. 200 ns max. 5° max. 2 : 1 max. 2 : 1 min. 40 dB Quartz 28° C -0,04 ppm/K² ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz) Operating temperature range Storage temperature range 0 °C ... + 70 °C - 40 °C ... + 85 °C * ) fTo is reference frequence fc at frequency inversion temperature (To ) Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs140F.doc Version 1.5 VI TELEFILTER Filter Specification 08.01.2001 TFS 140F - 2/5 3. Package D atec od e: L M N ....... T FS 14140F T FS 0 G1 19 NM 02 P in P in P in P in P in 10 1 5 6 2 - 4, 7 - 9 Y ear+ w eek 19 99 20 00 20 01 .......... Input Inp ut R F R etu rn Outp ut O utp ut R F R eturn P ack ag e G rou nd 4. 50 Ω matching networks ( see Application Note ): L1 50 Ω L3 10 9 8 7 T FS . R1 1 6 140 F N02 2 3 4 R2 L4 50 Ω L2 5 Scheme 1 L1 10 50 Ω C1 9 8 7 T FS . R1 1 2 6 140 F N02 3 4 5 R2 C2 50 Ω L2 Scheme 2 For final test we use scheme 1. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs140F.doc Version 1.5 VI TELEFILTER Filter Specification 08.01.2001 TFS 140F - 3/5 5. Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) Do W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 32 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 14,2 ± 0,1 0,6 2 ± 0,1 12 ± 0,1 2,0 7,1 ± 0,1 19,6 ± 0, 25,5 ± 0,1 Po P 2 E A o F D CT 1 W Bo G P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 32,4 +2 38,4 100 C C : 13 +0,5/-0,2 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs140F.doc Version 1.5 VI TELEFILTER Filter Specification 08.01.2001 TFS 140F - 4/5 7. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs140F.doc Version 1.5 VI TELEFILTER Filter Specification 08.01.2001 TFS 140F - 5/5 History : Version Reason of Changes Name Date 1.0 Generate specification according to customer requirements. Dunzow W. 15.05.2000 1.1 Add theoretical matching network scheme. Change filter name from TFS 140F1 to TFS 140F Change input and output pin positions according to customer requirements. Dunzow W. 31.05.2000 1.2 Correct errors in matching network scheme. Dunzow W. 05.06.2000 1.3 Change limit value ILo : from ILo = max. 19 dB to ILo = max. 20 dB Correct wrong unit for limit value of TTS ( ns → dB ). Add VSWR according to customer requirement. Dunzow W. 22.06.2000 1.4 Change the following parameters according to customer requirements - Ambient temperature TA from 23 °C to 25 °C, - limit value of Pass band from fC ± 1,55 MHz to fC ± 1,6 MHz, - Amplitude ripple (p-p) section removed, - Bandwidth section removed, - Relative attenuation (3 dB) from fC ± 1,55 MHz to fC ± 1,6 MHz, - Relative attenuation (40 dB) from fC ± 2,30 MHz … fC ± 5,94 MHz to fC ± 2,35 MHz … fC ± 6,0 MHz, - Relative attenuation (45 dB) from fC ± 5,94 MHz … fN ± 40 MHz to fC ± 6,0 MHz … fC ± 40 MHz, Generate Filter Specification. - add typical values; - add termination impedances; - add pass band ripple max.1 dB in fC ... fC ± 1,35 MHz. A Jaffer 13.09.2000 Dunzow W. 09.01.2000 1.5 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.