VECTRON TFS402

Tfs402.doc
Version 2.0
VI TELEFILTER
Filter Specification
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances in fc:
25 °C
0 dBm
for input:
for output:
17.04.2000
TFS 402
1/5
50 Ω  0 pF.
50 Ω  0 pF.
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 402 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at
the 6 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 402,76 MHz without tolerance. The given
values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency
fc is shifted due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss (Reference level)
Nominal frequency
tolerance / limit
max 24
ae
dB
402,76 MHz
fN
Reference frequency fc at ambient temperature (fCTA)
402,76 ± 1
Pass band (-1 dB) in the operating temperature range:
Amplitude ripple in pass band (p-p):
with sliding interval 1 MHz in pass band (p-p):
Relative attenuation
-
max. 1,0 dB
-
max. 0,5 dB
arel
fN
fN ± 15,25 MHz
-
max. 1
dB
fN ± 24,5
MHz
fN ± 100
MHz
-
min. 38
dB
fN - 401
MHz
fN - 100
MHz
-
min. 25
dB
fN + 100
MHz
fN + 600
MHz
min. 25
dB
Group delay
470 µs
-
Deviation from linear phase in pass band (p-p):
max. 4,5 °
The part will not show any critical pyroelecric effect for temperature changes of
0,5 °C / min
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature T:
Operating temperature range
to work without damage
Storage temperature range
Responsible:
MHz
fN - 15,25 MHz ... fN + 15,25 MHz
- 72
ppm/°C
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
Generated:
Checked / approved :
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs402.doc
Version 2.0
VI TELEFILTER
Filter Specification
3. Package, pin grid 2,54 mm
8
9
10
7
2
17.04.2000
2/5
(All dimensions in mm)
6
5
TFS 402
M16
1
TFS 402
1
2
3
4
5
6
7
8
9
10
11
12
Datecode
4
3
Package Ground
Package Ground
Package Ground
Output RF Return
Output
Package Ground
Package Ground
Package Ground
Input
Input RF Return
Package Ground
Package Ground
Datecode:
K
L
M
...
Year+week
1998
1999
2000
4. 50 Ω - Matching network:
1
3
2
10
4
9
5
8
7
6
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs402.doc
Version 2.0
VI TELEFILTER
Filter Specification
17.04.2000
TFS 402
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER
TAPE
W
:
16
± 0,3
Po
:
4
± 0,1
Do
:
1,5
+ 0,5
E
:
1,75 ± 0,1
Po
D o
P
2
E
A
F
:
o
7,5 ± 0,1
F
G (min) :
D
0,75
13,4
P2
:
2
± 0,05
P1
:
8
± 0,1
D1(min) :
1,5
1
± 0,1
B
W
o
G
Ao
:
5,3
± 0,1
Bo
:
9,7
± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs402.doc
Version 2.0
VI TELEFILTER
Filter Specification
TFS 402
17.04.2000
4/5
5. Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs402.doc
Version 2.0
VI TELEFILTER
Filter Specification
17.04.2000
TFS 402
5/5
History
Version
Reason of Changes
Name
2.0
(former development specification version1.2 changed)
Steiner
- insertion loss, 23dB!24dB
- weekly date code introduced
- pass band spec and stopband attenuation spec changed to be valid at
room temperature only (frequency drift already included in customer limit scheme)
Date
17.04.2000
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information