Tfs402.doc Version 2.0 VI TELEFILTER Filter Specification 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C 0 dBm for input: for output: 17.04.2000 TFS 402 1/5 50 Ω 0 pF. 50 Ω 0 pF. 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 402 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 402,76 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (Reference level) Nominal frequency tolerance / limit max 24 ae dB 402,76 MHz fN Reference frequency fc at ambient temperature (fCTA) 402,76 ± 1 Pass band (-1 dB) in the operating temperature range: Amplitude ripple in pass band (p-p): with sliding interval 1 MHz in pass band (p-p): Relative attenuation - max. 1,0 dB - max. 0,5 dB arel fN fN ± 15,25 MHz - max. 1 dB fN ± 24,5 MHz fN ± 100 MHz - min. 38 dB fN - 401 MHz fN - 100 MHz - min. 25 dB fN + 100 MHz fN + 600 MHz min. 25 dB Group delay 470 µs - Deviation from linear phase in pass band (p-p): max. 4,5 ° The part will not show any critical pyroelecric effect for temperature changes of 0,5 °C / min Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T: Operating temperature range to work without damage Storage temperature range Responsible: MHz fN - 15,25 MHz ... fN + 15,25 MHz - 72 ppm/°C ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) - 40 °C ... + 85 °C - 40 °C ... + 85 °C Generated: Checked / approved : ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 2.0 VI TELEFILTER Filter Specification 3. Package, pin grid 2,54 mm 8 9 10 7 2 17.04.2000 2/5 (All dimensions in mm) 6 5 TFS 402 M16 1 TFS 402 1 2 3 4 5 6 7 8 9 10 11 12 Datecode 4 3 Package Ground Package Ground Package Ground Output RF Return Output Package Ground Package Ground Package Ground Input Input RF Return Package Ground Package Ground Datecode: K L M ... Year+week 1998 1999 2000 4. 50 Ω - Matching network: 1 3 2 10 4 9 5 8 7 6 ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 2.0 VI TELEFILTER Filter Specification 17.04.2000 TFS 402 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) EMBOSSED CARRIER TAPE W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 E : 1,75 ± 0,1 Po D o P 2 E A F : o 7,5 ± 0,1 F G (min) : D 0,75 13,4 P2 : 2 ± 0,05 P1 : 8 ± 0,1 D1(min) : 1,5 1 ± 0,1 B W o G Ao : 5,3 ± 0,1 Bo : 9,7 ± 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 16,4 +2 22,4 >= 90 C C : 13 ± 0,25 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 2.0 VI TELEFILTER Filter Specification TFS 402 17.04.2000 4/5 5. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 2.0 VI TELEFILTER Filter Specification 17.04.2000 TFS 402 5/5 History Version Reason of Changes Name 2.0 (former development specification version1.2 changed) Steiner - insertion loss, 23dB!24dB - weekly date code introduced - pass band spec and stopband attenuation spec changed to be valid at room temperature only (frequency drift already included in customer limit scheme) Date 17.04.2000 ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] ____________________________________________________________________________________________________________________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information