tfs 150F4.doc Version 3.0 VI TELEFILTER Filter Specification 06.01.02 TFS 150F - 1/3 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 °C 0 dBm. for input: for output: 313 Ω - 11,74 pF. 2620 Ω - 4,2 pF. 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 150F2 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 32 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value Insertion loss (Reference level) Centre frequency 29 ae fc at ambient temperature TA (fCAT) 150 tolerance / limit dB max. 35 MHz Pass band at ambient temperature TA: 150,0±0,05 fC-4,80 MHz.....fC+4,80 Amplitude ripple in pass band (p-p): fC ... fC ± 4,80 MHz 0,5 dB MHz MHz dB max. 0,8 dB MHz MHz MHz MHz MHz MHz min. 9,6 MHz min. 10,0 MHz max. 10,8 MHz Bandwidth at ambient temperature: 0,8 dB - band width 1,0 dB - band width 2 dB - band width 3 dB - band width 25 dB - band width 32 dB - band width Relative attenuation 9,93 10,010 10,066 10,137 10,653 10,730 arel fC fC ± 4,80 MHz max. 0,8 dB MHz ..... fC ± 4,975 MHz max. 2 dB fC ± 4,80 MHz max. 3 dB fC ± 4,975 MHz ..... fC ± 5,0 MHz ..... fC ± 8,75 MHz 34....50 dB min. 32...45 dB fC ± 5,4 In the frequency range fc ± 5,4 MHz ... fc ± 8,75 MHz the type of the LIMIT LINE is a SLOPING LINE (SL). MHz ..... fC ± 48,75 MHz 55...70 dB min 45 dB fC ± 8,75 65...70 dB fC ± 48,75 MHz ..... fC ± 98,75 MHz Group delay ( mean value in pass band ): 2,875 µs max 5 µs Group delay ripple in pass band (p-p): 50...70 ns max 120 ns Deviation from linear phase in pass band (p-p): 2,6 ° (r.m.s. 0,5°) Triple transit attenuation compared to main signal 66 dB Crosstalk 52...56 dB Frequency inversion temperature ( To ) 10° C -0,054 ppm/K² Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature: * ) ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz) Operating temperature range - 25 °C ... + 75 °C Storage temperature range - 40 °C ... + 85 °C Input power level max. + 10 dBm. * ) fTo is reference frequence fc at frequency inversion temperature (To ) Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs 150F4.doc Version 3.0 VI TELEFILTER Filter Specification 06.01.02 TFS 150F - 2/3 3. Package TFS 150F TFS71 E tft L10 tft L8 Pin 1 Pin 14 Pin 8 Pin 7 Pin 2,9 Input Input RF Return Output Output RF Return Pakage Ground 4. 50 Ω matching network: 1 2 C1 7 L1 L2 14 9 C2 8 Remark: L1 , L2 have to be adjusted (refer to Application Note TFS 150F). VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs 150F4.doc Version 3.0 VI TELEFILTER Filter Specification 06.01.02 TFS 150F - 3/3 5. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.