VECTRON TFS400

version 1.3
06.01.02
______________________________________________________________________________________________________
tfs400.doc
VI
TELEFILTER
Filter specification
TFS 400
1/4
______________________________________________________________________________________________________
Application
The filter is suitable for GSM, DCS 1800 and dual band receivers. It can especially be used in the first IF in which
full channel selectivity is not necessary. Due to the high frequency the filter is small, thus it saves cost and space
on the printed circuit board. As it has symmetrical input and output it does not need any transformation networks
in state of the art IC transceiver concepts in which symmetrical inputs and outputs are favourable.
Measurement condition
Ambient temperature: 23 °C
Input power level:
0 dBm
Source impedance: balanced 800 Ω II - 0.7 pF
Load impedance: balanced 800 Ω II - 0.7 pF
Construction and pin configuration
see page 2
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 400_1 is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at
the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 400,000 MHz without tolerance. The given
values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency
fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre
frequency fo.
Data
typ. value
tolerance/limit
______________________________________________________________________________________________________
Insertion loss
(Reference level)
ae = amin
4,5
max. 6,5
dB
______________________________________________________________________________________________________
400,000 MHz
fo
______________________________________________________________________________________________________
Centre frequency
usable signal bandwidth
-
min 140
kHz
______________________________________________________________________________________________________
360
kHz
min 280
kHz
BW
______________________________________________________________________________________________________
3 dB bandwidth
arel
Relative attenuation
400 MHz ± 400 kHz
400 MHz ± 600 kHz
400 MHz ± >1 MHz ... f ± 13 MHz
25
35
44
dB
dB
dB
min 15
min 27
min 35
dB
dB
dB
µs
max. 2
µs
______________________________________________________________________________________________________
Group delay ripple
400 MHz ± 70 kHz
GD
0,5
______________________________________________________________________________________________________
- 20 °C ... + 70 °C
Operating temperature range
__________________________________________________________________________________________
ca. - 0.036 ppm/K²
Temperature coefficient of frequency TC
__________________________________________________________________________________________
Frequency inversion temperature
+ 20 °C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
version 1.3
06.01.02
______________________________________________________________________________________________________
tfs400.doc
VI
TELEFILTER
Filter specification
TFS 400
2/4
______________________________________________________________________________________________________
Construction, pin configuration and 50 Ω - matching network
TFS 400
tft
L5
Stability characteristics
After the following tests the filter shall meet the whole specification:
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
version 1.3
06.01.02
______________________________________________________________________________________________________
tfs400.doc
VI
TELEFILTER
Filter specification
TFS 400
3/4
______________________________________________________________________________________________________
1. Shock:
30g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes;
DIN IEC 68 T2 - 6
3. Damp heat:
90 % to 95 % rel. humidity, 40 °C, 10 days;
IEC Pub. 68 - 2 - 3
4. Resistance to
solder heat (Reflow):
260 °C for 10 sec;
Packing
Tape & Reel:
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 2300
Tape (all dimensions in mm)
W
Po
:
:
16
4
Do
:
1,5 + 0,5
D1
E
:
:
1,5 + 0,5
1,75 ± 0,1
F
:
G (min) :
7,5 ± 0,1
0,75
P2
P1
:
:
2
12
± 0,1
± 0,1
D1(min) :
Ao
:
Bo
:
1,5
7,6
9,6
± 0,1
± 0,1
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
Do
Po
P2
E
Ao
F
D1
13,4
± 0,1
W
Bo
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
pre-heating periods
main-heating periods
peak temperature
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
version 1.3
06.01.02
______________________________________________________________________________________________________
tfs400.doc
VI
TELEFILTER
Filter specification
TFS 400
4/4
______________________________________________________________________________________________________
Temperature:
Time:
150 °C - 170 °C
60 sec. - 90 sec.
over 200 °C
20 sec. - 25 sec.
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information