ETC CMM1330-AK-000T

CMM1330
Advanced Product Information
September 1996
(1 of 2)
1.85 to 1.91 GHz
3V, 30 dBm PCS/PCN
Power Amplifier
Features
❏ 40% Linear Power Added Efficiency
❏ 30 dBm Output Power (IS-136 TDMA)
❏ 30 dB Gain
❏ Low Cost, SO-8 Surface Mount Package
❏ Tested Under Digital Modulation
Functional Block Diagram
Applications
❏ IS-136 Handsets
❏ Wireless Local Loop Subscriber Units
❏ PCS Base Stations
V g2 4
5 RF OUT/Vd3
Vg1 3
6 RF OUT/Vd3
GND 2
7 Vd2
RF IN 1
8 Vd1
Back plane is ground and
must be soldered to thermally
conductive ground plane.
of PCS-1900, IS-136, or DCS-1800 systems.
The CMM1330 is packaged in a low-cost, space
efficient SO-8 power package that gives excellent electrical
stability and thermal handling performance with a RΘ of less
than 18° C/W. The part is designed to require minimal external circuitry for bias matching, simplifying design and keeping board space and cost to a minimum.
Description
The CMM1330 is a 3V linear power amplifier
intended for use in PCS handsets, wireless local loop subscriber units and PCS base stations. As a pin-compatible
member of the new Triniti DX™ amplifier family, the
CMM1330 offers maximum performance and flexibility. The
flexible amplifier can be biased to support the requirements
Absolute Maximum Ratings
Parameter
Rating
Parameter
Rating
Parameter
Rating
Drain Voltage (+Vd)
Drain Current (Id)
RF Input Power
DC Gate Voltage (-Vg)
+9.0 V*
1.8 A
+15 dBm*
-4.0 V*
Power Dissipation
Thermal Resistance
Storage Temperature
5W
18°C/W
-65°C to +150°C
Operating Temperature
Channel Temperature
Soldering Temperature
-40°C to +100°C
175°C
260°C for 5 Sec.
* Max (+Vd) and (-Vg) under linear operation. Max potential difference across the device in RF compression (2Vd + |-Vg|) not to exceed the minimum breakdown voltage (Vbr) of +18V.
Recommended Operating Conditions
Parameter
Typ
Units
Parameter
Typ
Units
Drain Voltage (+Vd)
3.0 to 4.0
Volts
Operating Temperature (PC Board)
-30 to +80
°C
Electrical Characteristics
Unless otherwise specified the following specifications are guaranteed at room temperature with drain voltage (+Vd) = 3.6 V, in Celeritek test fixture.
Parameter
Frequency Range
Power Output
Efficiency
Gain
Harmonics (in Celeritek test fixture)
Return Loss
Negative Supply Current
Supply Current
Quiescent Current
3236 Scott Boulevard
Condition
Min
Meets IS-136 TDMA mask
Pout IS-136 TDMA
1.85
28.8
30
28
Typ
Max
Units
1.91
GHz
dBm
%
dB
dBc
dBc
dB
mA
mA
mA
30.0
35
30
2nd @ Pout = +30.5 dBm
3rd @ Pout = +30.5 dBm
In Celeritek Test Fixture
-30
-35
10
No RF
600
300
1
Santa Clara, California 95054
Phone: (408) 986-5060
Fax: (408) 986-5095
Advanced Product Information - September 1996
CMM1330
(2 of 2)
Connection Diagram and Pin Descriptions
Vd3
Pin #
1
2
3
RF OUT/Vd3
4
Vg2
4
5
Vg1
3
6
MATCH
GND
2
7
Vd2
1
8
Vd1
MATCH
RF IN
Name
RF IN
GND
Vg1
Description
RF input (internally DC blocked)
Ground
Input stage gate bias
Vg2
RF OUT/Vd3
Output stage gate bias
5
6
RF OUT/Vd3
7
Vd2
Vd1
8
RF output and Vd3. External matching circuit required
RF output and Vd3. External matching circuit required
Intermediate stage drain bias
Input stage drain bias
Physical Dimensions
Ordering Information
The CMM1330 is available in a surface mount SO-8 power package and devices are available in tape and reel.
Part Number for Ordering
Package
CMM1330-AK
SO-8 surface mount power package
CMM1330-AK-000T
SO-8 surface mount power package in tape and reel
Celeritek reserves the right to make changes without further notice to any products herein. Celeritek makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does Celeritek assume any liability arising out of the application or use of any product or circuit, and specifically
disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters can and do vary in different applications. All operating
parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Celeritek does not convey any license under its patent
rights nor the rights of others. Celeritek products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or
other applications intended to support or sustain life, or for any other application in which the failure of the Celeritek product could create a situation where personal injury
or death may occur. Should Buyer purchase or use Celeritek products for any such unintended or unauthorized application, Buyer shall indemnify and hold Celeritek and
its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of,
directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Celeritek was negligent
regarding the design or manufacture of the part. Celeritek is a registered trademark of Celeritek, Inc. Celeritek, Inc. is an Equal Opportunity/Affirmative Action Employer.
3236 Scott Boulevard, Santa Clara, California 95054
Phone: (408) 986-5060
Fax: (408) 986-5095