GFPS-9 Description Gamewell-FCI Power Supply 9 A unique feature allows for programmable synchronizedoutputs for strobes by three (3) different major manufacturers, System Sensor, Faraday, or Gentex. The GFPS-9 contains its own battery charger capable of maintaining batteries of up to 33 AH. The cabinet provides space for a set of 7 A/H batteries. It is supervised for ground fault, over-current, open circuits and low battery conditions. These conditions light the appropriate trouble LED and automatically open the notification appliance circuit used for activation, transmitting a trouble signal to the main fire alarm control panel. The ground fault detection circuit may be disabled. The unit contains a set of dry, Form “C” trouble actuated auxiliary contacts, rated 2.5 amp. @ 24 VDC (resistive). Transfer of these contacts for AC power failure is programmable and can be delayed for a period of six (6) hours. This delay feature may be disabled. 9020-60236ph1.wmf The Gamewell-FCI Power Supply 9 (GFPS-9) panel provides two (2) Class A, Style Z, or four (4) Class B, Style Y notification appliance circuits. Each circuit is rated at 3 amperes, with a total capacity of 9 amperes per panel. These circuits may be programmed to activate by groups or various combinations by connection to one (1) or two (2) existing Class A or B notification appliance circuits with operating voltages ranging from 9 to 30 VDC. Either noncoded or coded operation is possible. In addition, the GFPS-9 can provide a temporal pattern output from a noncoded input. GFPS-9 Features • • • • • • • UL Listed as a fire alarm accessory for use with any Gamewell-FCI or other UL Listed fire alarm controls. Two (2) Class A (Style Z), or four (4) Class B (Style Y) notification appliance circuits. Programmable temporal pattern output including ANSI S3.41. High current 9 amp. total output. Integral strobe synchronization feature for strobes by three (3) manufacturers. Integral ground fault detection. Form “C” trouble contacts with delayed AC failure indication. A power limited, non-resettable auxiliary power output up to three (3) amperes is also available. The panel can be programmed via DIP switch to disconnect this output from the batteries 30 seconds after AC power failure, in order to avoid running down the batteries from current devices such as door holders, etc. An ISO 9000-2000 Company SIGNALING GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-60236 Rev. A page 1 of 2 Specifications Operating Power: Standby Battery Circuit: Supervisory Current: Alarm Current: Alarm Output: Dimensions: Operating Temperature: Relative Humidity: Ordering Information 120 VAC, 3.6 amp. 60 Hz 24 VDC (nominal) 7 ampere/ hours, max. 0.075 amp. 0.175 amp. (excluding notification appliances) 9.0 amp. max. @ 24 VDC (nominal) 16" H x 12.25" W x 3" D (40.64 x 30.88 x 7.62 cm ) Model GFPS-9 Description Gamewell-FCI Power Supply-9 32° to 120° F (0° to 49° C) 10 to 85% @ 86° F (non-condensing) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9020-60236 Rev. A page 2 of 2