MICREL SY100S350JZTR

Micrel, Inc.
SY100S350
FEATURES
■
■
■
■
■
■
■
■
■
■
■
SY100S350
HEX D-LATCH
DESCRIPTION
The SY100S350 offers six high-speed D-Latches with
both true and complement outputs, and is performance
compatible for use with high-performance ECL systems.
When both enable signals (Ea and Eb) are at a logic LOW,
the latches are transparent and the input signals( D0–D5)
appear at the outputs (Q0–Q5) after a propagation delay. If
either or both of the enable signals are at a logic HIGH, then
the latches store the last valid data present on its inputs
before Ea or Eb went to a logic HIGH. The Master Reset
(MR) overrides all other input signals and takes the outputs
to a logic LOW state. All inputs have 75KΩ pull-down
resistors.
Max. transparent propagation delay of 900ps
Min. Master Reset and Enable pulse widths of 100ps
IEE min. of –98mA
Industry standard 100K ECL levels
Extended supply voltage option:
VEE = –4.2V to –5.5V
Voltage and temperature compensation for improved
noise immunity
Internal 75KΩ input pull-down resistors
More than 40% faster than Fairchild
Approximately 30% lower power than Fairchild
Function and pinout compatible with Fairchild F100K
Available in 24-pin CERPACK and 28-pin PLCC
packages
BLOCK DIAGRAM
D5
Eb
Ea
MR
D4
D
E
D1
M9999-032206
[email protected] or (408) 955-1690
R
Q3
Q2
R
Q2
Q1
R
D
E
Q4
Q3
D
E
D0
R
D
E
Q5
Q4
D
E
D2
R
D
E
D3
Q5
Q1
Q0
R
Q0
Rev.: H
1
Amendment: /0
Issue Date: March 2006
SY100S350
Micrel, Inc.
Ordering Information
Q1
Q1
Q0
D0
Q0
VEES
D1
PACKAGE/ORDERING INFORMATION
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY100S350FC
F24-1
Commercial
SY100S350FC
Sn-Pb
SY100S350FCTR(1)
F24-1
Commercial
SY100S350FC
Sn-Pb
VCC
VCC
SY100S350JC
J28-1
Commercial
SY100S350JC
Sn-Pb
Q3
SY100S350JCTR(1)
J28-1
Commercial
SY100S350JC
Sn-Pb
Q3
SY100S350JZ(2)
J28-1
Commercial
SY100S350JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100S350JZTR(1, 2)
J28-1
Commercial
SY100S350JZ with
Pb-Free bar-line indicator
Matte-Sn
11 10 9 8 7 6 5
D2
D3
VEE
VEES
12
13
4
3
14
15
Ea
16
17
Eb
18
MR
Part Number
2
1
Top View
PLCC
J28-1
28
27
26
Q2
Q2
VCCA
Q4
Q5
Q4
VEES
D5
Q5
D4
19 20 21 22 23 24 25
Notes:
D2
D3
D1
2
3
17
16
D0
Q0
15
14
Q0
Q1
13
7 8 9 10 11 12
Q1
4
5
6
Q2
Q2
Top View
Flatpack
F24-1
Q3
Q4
24 23 22 21 20 19
18
VCCA
Q5
Q5
Q4
1. Tape and Reel.
2. Pb-Free package is recommended for new designs.
1
Q3
VCC
D4
D5
Ea
MR
VEE
Eb
28-Pin PLCC (J28-1)
24-Pin Cerpack (F24-1)
M9999-032206
[email protected] or (408) 955-1690
2
SY100S350
Micrel, Inc.
PIN NAMES
Pin
Function
D0 — D5
Data Inputs
Ea, Eb
Common Enable Inputs (Active LOW)
MR
Asynchronous Master Reset Input
Q0 — Q5
Data Outputs
Q0 — Q5
Complementary Data Outputs
VEES
VEE Substrate
VCCA
VCCO for ECL Outputs
TRUTH TABLE(1)
Each Latch
Inputs
Outputs
Dn
Ea
Eb
MR
Qn
Qn
Operating Mode
H
L
X
X
L
L
X
H
L
L
H
X
L
L
L
L
H
L
Latched(2)
Latched(2)
L
H
Latched(2)
Latched(2)
Latch
X
X
X
H
L
H
Asynchronous
NOTES:
1. H = HIGH State
L = LOW State
X = Don't Care
2. Retains data that is present before E positive transition.
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol
IIH
IEE
Parameter
Input HIGH Current
MR
Dn
Ea, Eb
Power Supply Current
M9999-032206
[email protected] or (408) 955-1690
Min.
Typ.
Max.
—
—
—
—
—
—
250
250
250
–98
–78
–49
3
Unit
Condition
µA
VIN = VIH (Max.)
mA
Inputs Open
SY100S350
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
CERPACK
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
Dn to Output
300
1000
300
1000
300
1000
ps
tPLH
tPHL
Propagation Delay
Ea, Eb to Output
300
1100
300
1100
300
1100
ps
tPLH
tPHL
Propagation Delay
MR to Output
300
1250
300
1250
300
1250
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
tS
Set-up Time, Dn to En
500
—
500
—
500
—
ps
tH
Hold Time, Dn to En
500
—
500
—
500
—
ps
tr
Release Time, MR to En
1000
—
1000
—
1000
—
ps
tPW (L)
Pulse Width, Ea, Eb
1000
—
1000
—
1000
—
ps
tPW (H)
Pulse Width, MR
1000
—
1000
—
1000
—
ps
Condition
PLCC
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
Dn to Output
300
900
300
900
300
900
ps
tPLH
tPHL
Propagation Delay
Ea, Eb to Output
300
1000
300
1000
300
1000
ps
tPLH
tPHL
Propagation Delay
MR to Output
300
1200
300
1200
300
1200
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
tS
Set-up Time, Dn to En
500
—
500
—
500
—
ps
tH
Hold Time, Dn to En
500
—
500
—
500
—
ps
tr
Release Time, MR to En
1000
—
1000
—
1000
—
ps
tPW (L)
Pulse Width, Ea, Eb
1000
—
1000
—
1000
—
ps
tPW (H)
Pulse Width, MR
1000
—
1000
—
1000
—
ps
M9999-032206
[email protected] or (408) 955-1690
4
Condition
SY100S350
Micrel, Inc.
TIMING DIAGRAMS
0.7 ± 0.1 ns
–0.95V
DATA
–1.69V
tW(L)
–0.95V
ENABLE
LATCHES
TRANSPARENT
TRANSPARENT
–1.69V
tPHL, tPLH
tPHL, tPLH
tPHL, tPLH
80%
50%
20%
OUTPUT
tTHL, tTLH
Enable Timing
Note:
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
DATA
ENABLE
LATCHED
TRANSPARENT
TRANSPARENT
tR RELEASE TIME
MR
tW(L)
tPHL, tPLH
tPHL, tPLH
OUTPUT
Reset Timing
M9999-032206
[email protected] or (408) 955-1690
5
tPHL, tPLH
SY100S350
Micrel, Inc.
TIMING DIAGRAMS
DATA
tS
th
ENABLE
Data Set-up and Hold Times
Notes:
tS is the minimum time before the transition of the clock that information must be present at the data input.
tH is the minimum time after the transition of the clock that information must remain unchanged at the data input.
M9999-032206
[email protected] or (408) 955-1690
6
SY100S350
Micrel, Inc.
24-PIN CERPACK (F24-1)
Rev. 03
M9999-032206
[email protected] or (408) 955-1690
7
SY100S350
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032206
[email protected] or (408) 955-1690
8