TFS 240h.doc version 2.0 VI TELEFILTER Filter Specification 13.06.2003 TFS 240 H 1/5 Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc*: 25 0 input: output: °C dBm 455 // -9,1 pF 520 // -8,3 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 240 H is the insertion loss. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 25 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value tolerance / limit Insertion loss ae 7,2 dB Centre frequency fc - max. 9 240 MHz ± 25 dB kHz (reference frequency at ambient temperature) Passband Ripple (p-p) fc 100 kHz arel 0,1 MHz 0,15 MHz Relative attenuation fc fc fc fc fc ± 0,1 ± ± ± 0,375 0,575 0,975 10 fc + 5 ......... fc MHz ......... fc ± ± MHz MHz MHz MHz MHz ± 0,575 ± 0,975 ± 5 5 + 360 ......... fc ......... fc ......... fc ......... fc ......... fc MHz MHz MHz MHz MHz Triple transit response suppression Group delay ripple in fc 100 kHz Average group delay in fc 100 kHz Return loss in fc 150 kHz 0,25 dB max. 0,5 dB 0,25 dB 0,75 dB max. max. 0,5 dB 1 dB 30 33 40 45 45 dB dB dB dB dB min. min. min. min. min. 25 30 35 38 38 dB dB dB dB dB 25 dB min. 15 dB 270 ns max. 400 ns 2,1 µs max. 2,4 µs min. 7 10 dB Input Power Level - Operating temperature range - - 30 °C.... + 80 °C - - 40 °C.... + 85 C Storage temperature range max. 20 dB Temperature coefficient of frequency TCf ** -0,04 ppm/K 2 - Frequency inversion temperature T0 28 - °C dBm***) *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) ***) This power level is allowed for short term operation (10% of life time) only, the max. input power for continuous operation is 15 dBm **) generated: checked / approved: TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 240h.doc version 2.0 VI TELEFILTER Filter Specification Construction, pin configuration and 50 - matching network 13.06.2003 TFS 240 H 2/5 (all dimensions in mm) 24.64 1 2 3 4 5 6 7 8 9 10 TFS 240H 9.00 R24 2.62 Max 1.02 1 2 3 4 5 7 6 date code output ground ground ground input rf return input ground ground ground output rf return date code: year + week N 2001 P 2002 R 2003 ...... 11 10 4.83 x 3.53 50 9 8 1.91 2.31 1.02 test circuit L1 Input 50 Ohm 6 1 L2 Output 50 Ohm SAW C1 C2 2,3,4,5,7,8,9,10 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 240h.doc version 2.0 VI TELEFILTER Filter Specification 13.06.2003 TFS 240 H 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: DIN IEC 286 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer pull off direction Tape (all dimensions in mm) W Po Do E F G (min) P2 P1 D1(min) : : : : : : : : : 44 4 1,5 1,75 20,25 0,75 2 16 2,0 ± 0,3 ± 0,1 + 0,1 ± 0,1 ± 0,05 Ao Bo CT : : : 9,3 24,9 38 ± 0,1 ± 0,1 ± 0,2 ± 0,05 ± 0,1 1000 min 300 mm min 500 mm min 300 mm X-X Po t X P1 P2 Do view direction Ko D1 Ao X SPEC-Gurt 0061/ 19X6,5 Q09016:02.001 Jul.10,01 W2 Reel (all dimensions in mm): A W1 W2 (max) N (min) C : : : : : 330 44,4 +2,0 / -0 50,4 100 13 +0,5 / -0,2 C A N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape in the above shown direction. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 240h.doc version 2.0 VI TELEFILTER Filter Specification 13.06.2003 TFS 240 H 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile pre-heating periods 150 °C - 170 ° Name: Temperature: Time: main-heating periods Cover 200 °C 60 sec. - 90 sec. peak temperature 255 °C ± 5 °C 20 sec. - 25 sec. Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 240h.doc VI TELEFILTER version 2.0 Filter Specification 13.06.2003 TFS 240 H 5/5 History Version Reason of Changes Name Date 1.0 generation of development specification Pfeiffer 25.02.2003 2.0 typical values, matching configuration and terminating impedances added package changed Pfeiffer 13.06.2003 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information