VECTRON TFH44C

TFH44C.doc
version 1.2
VI TELEFILTER
Filter Specification
13.03.01
TFH 44 C
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
25 °C
10 dBm
50 Ω || 0 pF
50 Ω || 0 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFH 44C is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the frequency response
of the filter on the operating temperature.
Data
typ. value
Insertion loss
(Reference level)
ae
22,6
Nominal frequency
fN
-
Centre frequency
fC
44,0
Passband
PB
Passband variation
p-p
0,45
dB
3 dB bandwidth
BW
8,11
MHz
Relative attenuation
arel
fN ±
4,00 MHz
fN ±
4,80 MHz ......... fN ± 15 MHz
Group delay variation in PB
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature T:
Operating temperature
Storage temperature range
dB
tolerance/limit
max.
MHz
24,0
dB
44,0
MHz
fN ±
2,8
MHz
0,60
dB
min.
8,00
MHz
max.
3
dB
42
dB
min.
40
dB
55
ns
max.
70
ns
-75
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
25
- 25..... + 85
°C
°C
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFH44C.doc
version 1.2
VI TELEFILTER
Filter Specification
13.03.01
TFH 44 C
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
24.64
TFH
44C
N07
Datecode:
L
M
N
....
9.00
Year+week
1999
2000
2001
2.62 Max
1.02
1
2
3
4
Pin Configuration
5
11
10
4.83 x 3.53
9
1.91
8
7
2.31
6
Input:
Input Return:
Output:
Output Return:
Ground:
10
1
5
6
2,3,4,7,8,9,11
1.02
50 Ohm test circuit
10
6
1
5
RS
RL
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFH44C.doc
version 1.2
VI TELEFILTER
Filter Specification
13.03.01
TFH 44 C
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
tape & reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
1000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
D
Tape (all dimensions in mm)
W
Po
Do
E
F
G (min)
P2
P1
D1(min)
Ao
Bo
CT
:
:
:
:
:
:
:
:
:
:
:
:
44
± 0,3
4
± 0,1
1,5
+ 0,1
1,75 ± 0,1
20,25 ± 0,05
0,75
2
± 0,05
16
± 0,1
2,0
9,3
± 0,1
24,9 ± 0,1
38
± 0,2
P
0
0
P
2
E
A
o
F
D
1
W
CT
B
o
G
P
1
COVER TAPE
W2
Reel (all dimensions in mm):
A
W1
W2 (max)
N (min)
C
:
:
:
:
:
330
46
50
100
13 ± 0,2
C
A
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFH44C.doc
version 1.2
VI TELEFILTER
Filter Specification
13.03.01
TFH 44 C
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFH44C.doc
version 1.2
VI TELEFILTER
Filter Specification
13.03.01
TFH 44 C
5/5
History
version
reason of changes
name
date
1.0
generate extended specification
Pfeiffer
22.02.2001
1.1
- relative attenation fN ± 4,80MHz .........fN ± 15 MHz : min 40 dB
- passband variation : 0,60 dB
- change typical values
Pfeiffer
08.03.2001
1.2
- change tape dimensions
Pfeiffer
13.03.2001
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.