TFH70F.doc version 1.2 VI TELEFILTER 20.06.2001 Filter Specification TFH 70F 1/5 Measurement condition Ambient temperature: 25 °C Input power level: 10 dBm for input: Terminating impedances *): for output: 330 Ω ⎟⎢ -13,7 pF 250 Ω ⎟⎢ -15,7 pF Remark: Reference level for the relative attenuation arel of the TFH 70F is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal frequency fN . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The given values for the insertion loss, the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (Reference level) ae 20,6 dB Nominal frequency Passband Passband variation fN PB p-p 0,25 3 dB bandwidth 40 dB bandwidth BW BW 1,338 MHz 1,988 MHz Relative attenuation fN ± 0,578 MHz ....... arel fN - 1,09 fN + 1,09 fN ± 1,50 fN ± 4,00 fN fN fN fN tolerance/limit max. 24,0 dB fN ± 70,0 0,40 0,65 MHz MHz dB dB min. max. 1,156 MHz 2,180 MHz max. 3 dB dB dB dB dB min. min. min. min. 40 40 45 50 dB dB dB dB ° max. ns µs max. 175 max. 4,0 ns µs Operating temperature range - 20..+ 80 °C Storage temperature range - 25..+ 85 °C MHz ....... MHz ....... MHz ....... MHz ....... - 1,50 + 1,50 ± 4,00 ± 20 MHz MHz MHz MHz 43 45 48 54 Phase linearity in fN ± 0,578 MHz 3,3 Group delay variation in Absolute group delay fN ± 0,578 MHz 105 3,1 Temperature coefficient of frequency Tcf **) 5,5 ° - 0,036 ppm/K² * ) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K2) x (T - TA)2 x fCAT (MHz) Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFH70F.doc version 1.2 VI TELEFILTER 20.06.2001 Filter Specification TFH 70F 2/5 Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) 24.64 Datecode: L M N .... TFH 70F 9.00 N25 Year+week 1999 2000 2001 2.62 Max 1.02 1 2 3 4 Pin Configuration 5 Input: Input Return: Output: Output Return: Ground: 11 10 9 8 7 1.91 4.83 x 3.53 2.31 6 10 1 5 6 2,3,4,7,8,9,11 1.02 50 Ohm test circuit L1 5 10 TFH 70F IN L2 OUT 1,2.3.4, 6,7,8, 9 , 11 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFH70F.doc version 1.2 VI TELEFILTER 20.06.2001 Filter Specification TFH 70F 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing tape & reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 1000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 44 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 20,25 ± 0,05 0,75 2 ± 0,05 16 ± 0,1 2,0 9,3 ± 0,1 24,9 ± 0,1 38 ± 0,2 P0 D0 Tape (all dimensions in mm) P2 E Ao F D1 W CT Bo G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 W2 (max) N (min) C : : : : : 330 46 50 100 13 ± 0,2 C A N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFH70F.doc version 1.2 VI TELEFILTER 20.06.2001 Filter Specification TFH 70F 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFH70F.doc version 1.2 VI TELEFILTER 20.06.2001 Filter Specification TFH 70F 5/5 History version reason of changes name date 1.0 generate specification Pfeiffer 22.03.2001 1.1 change typical values Pfeiffer 10.05.2001 1.2 terminated impedances added Pfeiffer 20.06.2001 operating temperature range changed VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.