VECTRON TFS346A

TFS 346a.doc
version 2.0
VI TELEFILTER
Filter Specification
10.02.2003
TFS 346 A
1/5
Measurement condition
Ambient temperature T A:
Input power level:
Terminating impedances at fc *):
23 °C
0 dBm
input: 472
output: 210
// -6,6 pF
// -4,9 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 346A is the minimum of the pass band attenuation amin. The minimum of
the pass band attenuation amin is defined as the insertion loss ae The centre frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid for both the
reference frequency fc and the frequency response of the filter in the operating temperature range.
Data
typ. value
ae
Insertion loss
9,5 dB
tolerance / limit
max.
14,5 dB
(reference level)
Nominal frequency
Centre frequency at ambient temperature
fN
fc
Pass band
Amplitude ripple within PB
PB
In band ripple
346
346
MHz
MHz
-
0,4 dB
fN
max.
0,5 MHz
0,8 dB
0,1 dB
max.
0,5 dB p-p
(in any 112,5 kHz increment within the PB)
arel
Relative attenuation
fN
fN ±
fN ±
DC
fN +
.........
1,2
1,5
fN ±
0,5
MHz
fN
fN
fN
fN
1,5
3
3
1,5
MHz
MHz
MHz
GHz
±
±
+
0,4 dB
0,8 dB
min.
min.
min.
min.
39
40
50
50
dB
dB
dB
dB
1,75 µs
max.
2
µs
max. 120
ns
1,5 deg
max.
5
deg p-p
Input power level
-
max.
23
dBm**)
Operating temperature range
-
- 40 °C ... + 70
°C
Storage temperature range
-
- 40 °C ... + 100
°C
Group delay at fN
Group delay ripple in PB
42
45
55
53
max.
dB
dB
dB
dB
3
MHz .........
MHz .........
.........
MHz .........
50
ns
(in any 112,5 kHz increment within the PB)
Phase linearity in PB
(in any 112,5 kHz increment within the PB)
Turnover temperature To
20
°C
-
Temperature coefficient of frequency TCf***
- 0,05
ppm / K2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.15dBm
only
***) f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 346a.doc
version 2.0
VI TELEFILTER
Filter Specification
TFS 346 A
10.02.2003
2/5
Construction and pin connection
(All dimensions in mm)
1
2
3
4
5
6
7
8
9
10
15,32 ±0,20
TFS 346A
R06
1
1,0 0,2
date code
6,50 ±0,20
Input RF return
Ground
Ground
Ground
Output
Output
Ground
Ground
Ground
Input
Date code:
N
P
R
...
2,0Max.
year + week
2001
2002
2003
120°
1,9 0,2
1,91
7,62
50
0,2
0,2
matching network :
LB-IN
L1
10
SAW
L2
L4
6
L5
5
1
LB-OUT
L3
2,3,4,7,8,9
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 346a.doc
version 2.0
VI TELEFILTER
Filter Specification
10.02.2003
TFS 346 A
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
DIN IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
Tape (all dimensions in mm)
W
:
24
± 0,3
Po
:
4
± 0,1
Do
E
:
:
1,5 + 0,1
1,75 ± 0,1
F
:
11,5 ± 0,1
G (min) :
Ao
Bo
Ct
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
0,60
P2
:
P1
:
D1(min) :
:
:
:
2000
min 300 mm
min 500 mm
min 300 mm
F
D1
2
12
1,5
± 0,1
± 0,1
7,1
15,9
21,5
± 0,2
± 0,2
± 0,1
Ct
W
Bo
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
330
W1
:
W2 (max) :
24,40 +2,0
30,4
N (min)
:
60
C
:
13
0,5/-0.2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 346a.doc
version 2.0
VI TELEFILTER
Filter Specification
10.02.2003
TFS 346 A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 346a.doc
version 2.0
VI TELEFILTER
Filter Specification
TFS 346 A
10.02.2003
5/5
History
Version
Reason of Changes
Name
Date
1.0
- generate specification according to customer requirements
Pfeiffer
16.10.2002
1.1
- typical values added
- terminated impedance added
- triple transit suppression removed
Pfeiffer
04.02.2003
2.0
- filter name changed from TFS346 to TFS346A
Pfeiffer
11.02.2003
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.