W www.ti.com SCDS180 − FEBRUARY 2005 Description The TS5A4595 is a single-pole single-throw (SPST) analog switch that is designed to operate from 2 V to 5.5 V. This device can handle both digital and analog signals, and signals up to V+ can be transmitted in either direction. Applications Features D Low ON-State Resistance (8 W) D ON-State Resistance Flatness (1.5 W) D Control Inputs Are 5.5-V Tolerant D Low Charge Injection (5 pC Max) D 450-MHz −3-dB Bandwidth at 255C D Low Total Harmonic Distortion (THD) (0.04%) D 2-V to 5.5-V Single-Supply Operation D −82-dB OFF-Isolation at 1 MHz D Latch-Up Performance Exceeds 100 mA Per JESD 78, Class II D Sample-and-Hold Circuit D 0.5-nA Max OFF Leakage D ESD Performance Tested Per JESD 22 D Battery-Powered Equipment (Cellular Phones, PDAs) D Audio and Video Signal Routing D Communication Circuits D D PCMCIA Cards − 2000-V Human-Body Model (A114-B, Class II) − 1000-V Charged-Device Model (C101) TTL/CMOS-Logic Compatible Summary of Characteristics V+ = 5 V, TA = 25°C SOT-23 OR SC-70 PACKAGE (TOP VIEW) Single Pole Single Throw (SPST) Configuration Number of channels 1 COM 1 NC 2 ON-state resistance (ron) 3 ON-state resistance flatness (ron(flat)) GND 5 4 V+ IN 8Ω 1.5 Ω Turn-on/turn-off time (tON/tOFF) 17 ns/14 ns Charge injection (QC) 5 pC Bandwidth (BW) 450 MHz OFF isolation (OISO) FUNCTION TABLE −82 dB at 1 MHz Total harmonic distortion (THD) IN NC TO COM, COM TO NC L ON Power-supply current (I+) H OFF Package option 0.04% ±0.5 nA Leakage current(ICOM(OFF)/INC(OFF)) 0.25 µA 5-pin SOT-23 or SC-70 ORDERING INFORMATION TA −40°C to 85°C PACKAGE(1) ORDERABLE PART NUMBER TOP-SIDE MARKING(2) SOT (SOT-23) − DBV Tape and reel TS5A4595DBVR JSB_ SOT (SC−70) − DCK Tape and reel TS5A4595DCKR JT_ (1) Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. (2) DBV/DCK: The actual top-side marking has one additional character that designates the assembly/test site. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. !" # $%&" !# '%()$!" *!"& *%$"# $ " #'&$$!"# '& "+& "&# &,!# #"%&"# #"!*!* -!!". *%$" '$&##/ *&# " &$&##!). $)%*& "&#"/ !)) '!!&"&# Copyright 2005, Texas Instruments Incorporated W www.ti.com SCDS180 − FEBRUARY 2005 Pin Configurations Available in Other Pin Configurations COM 1 NC 2 GND 3 5 4 V+ COM 1 NO 2 GND 3 V+ 4 IN TS5A4594 IN TS5A4595 5 IN 1 5 V+ COM 2 IN 1 5 V+ 4 NC COM 2 4 GND 3 NO TS5A4596 GND 3 TS5A4597 Absolute Minimum and Maximum Ratings(1)(2) over operating free-air temperature range (unless otherwise noted) V+ VNC VCOM IK INC ICOM VI MIN MAX Supply voltage range(3) −0.3 6 UNIT V Analog voltage range(3)(4) −0.3 V+ + 0.3 V Analog port diode current VNC, VCOM < 0 −50 On-state switch current VNC, VCOM = 0 to V+ −20 20 mA −0.3 6 V Digital input voltage range(3)(4) IIK I+ Digital input clamp current IGND Continuous current through GND θJA Package thermal impedance(5) VI < 0 mA −50 Continuous current through V+ mA 100 −100 mA mA DBV package 206 DCK package 252 °C/W Tstg Storage temperature range −65 150 °C (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. (2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum (3) All voltages are with respect to ground, unless otherwise specified. (4) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. (5) The package thermal impedance is calculated in accordance with JESD 51-7. 2 W www.ti.com SCDS180 − FEBRUARY 2005 Electrical Characteristics for 5-V Supply(1) V+ = 4.5 V to 5.5 V, VIH = 2.4 V, VIL = 0.8 V TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX UNIT Analog Switch Analog signal range VCOM, VNC 0 V+ = 4.5 V, VNC = 3.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C VNC = 1.5 V, 2.5 V, 3.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C ron(flat) NC OFF leakage current VNC = 1 V, VCOM = 4.5 V, or VNC = 4.5 V, VCOM = 1 V, Switch OFF, See Figure 14 25°C INC(OFF) COM OFF leakage current VCOM = 1 V, VNC = 4.5 V, or VCOM = 4.5 V, VNC = 1 V, Switch OFF, See Figure 14 25°C ICOM(OFF) INC(ON) VNC = 1 V, VCOM = 1 V, or Switch ON, VNC = 4.5 V, VCOM = 4.5 V, See Figure 15 or VNC = 1 V, 4.5 V, VCOM = Open, ON-state resistance ron ON-state resistance flatness NC ON leakage current COM ON leakage current ICOM(ON) VCOM = 1 V, VNC = 1 V, or Switch ON, VCOM = 4.5 V, VNC = 4.5 V, See Figure 15 or VCOM = 1 V, 4.5 V, VNC = Open, Full V+ 5 4.5 V 8 10 0.5 2 −0.5 0.01 Ω 0.5 5.5 V Full Ω 1.5 4.5 V Full V nA −5 −0.5 5 0.01 0.5 5.5 V nA Full −5 25°C −1 5 0.01 1 5.5 V nA Full −10 25°C −1 10 0.01 1 5.5 V nA Full −10 10 Full 2.4 5.5 V Full 0 0.8 V 25°C −0.5 Digital Control Input (IN) Input logic high Input logic low Input leakage current VIH VIL IIH, IIL VI = V+ or 0 Full 5.5 V −5 0.01 0.5 5 µA A (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 3 W www.ti.com SCDS180 − FEBRUARY 2005 Electrical Characteristics for 5-V Supply(1) (continued) V+ = 4.5 V to 5.5 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX 12 17 UNIT Dynamic Turn-on time VNC = 3 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 5V tON Full 4.5 V to 5.5 V Turn-off time VNC = 3 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 5V tOFF Full 4.5 V to 5.5 V VGEN = 0, RGEN = 0, CL = 1 nF, See Figure 20 25°C 4.5 V to 5.5 V 19 9 ns 14 17 ns Charge injection QC NC OFF capacitance CNC(OFF) VNC = 0, f = 1 MHz, Switch OFF, See Figure 16 25°C 5V 6.5 pF COM OFF capacitance CCOM(OFF) VCOM = 0, f = 1 MHz, Switch OFF, See Figure 16 25°C 5V 6.5 pF NC ON capacitance CNC(ON)) VNC = 0, f = 1 MHz, Switch ON, See Figure 16 25°C 5V 13 pF COM ON capacitance CCOM(ON) VCOM = GND, f = 1 MHz, Switch ON, See Figure 16 25°C 5V 13 pF VI = V+ or GND, See Figure 16 25°C 5V 3 pF RL = 50 Ω, Switch ON, Signal = 0 dBm See Figure 18 25°C 5V 450 MHz Digital input capacitance Bandwidth CI BW 2 5 pC OFF isolation OISO RL = 50 Ω, VNC = 1 VRMS f = 1 MHz, CL = 5 pF Switch OFF, See Figure 19 25°C 5V −82 dB Total harmonic distortion THD RL = 600 Ω, CL = 50 pF, VSOURCE = 5 Vp-p, f = 20 Hz to 20 kHz, See Figure 21 25°C 5V 0.04 % Supply 25°C Positive supply I+ VI = V+ or GND, Switch ON or OFF 5.5 V current Full (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 4 0.01 0.25 0.5 µA A W www.ti.com SCDS180 − FEBRUARY 2005 Electrical Characteristics for 3-V Supply(1) V+ = 2.7 V to 3.6 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX UNIT Analog Switch Analog signal range VCOM, VNC ON-state resistance ron ON-state resistance flatness ron(flat) 0 V+ = 3 V, VNC = 1.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C VNC = 1.5 V, 2.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C Full VNC = 1 V, VCOM = 3 V, or VNC = 3 V, VCOM = 1 V, Switch OFF, See Figure 14 25°C COM OFF leakage current VCOM = 1 V, VNC = 3 V, or VCOM = 1 V, VNC = 3 V, Switch OFF, See Figure 14 25°C ICOM(OFF) INC(ON) VNC = 1 V, VCOM = 1 V, or VNC = 3 V, VCOM = 3 V, or VNC = 1 V, 3 V, VCOM = Open, Switch ON, See Figure 15 VCOM = 1 V, VNC = 1 V, or VCOM = 3 V, VNC = 3 V, or VCOM = 1 V, 3 V, VNC = Open, Switch ON, See Figure 15 ICOM(ON) 16 20 1.8 −0.5 0.01 −0.5 5 0.01 0.5 3.6 V nA −5 25°C Ω nA −5 Full Ω 0.5 3.6 V Full V 6 7 Full INC(OFF) COM ON leakage current 9.5 2.7 V 2.7 V NC OFF leakage current NC ON leakage current V+ −1 5 0.01 1 3.6 V nA Full −10 25°C −1 10 0.01 1 3.6 V nA Full −10 10 Full 2 5.5 V Full 0 0.8 V 25°C −0.5 Digital Control Input (IN) Input logic high Input logic low Input leakage current VIH VIL IIH, IIL VI = V+ or 0 Full 3.6 V −5 0.01 0.5 5 nA (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 5 W www.ti.com SCDS180 − FEBRUARY 2005 Electrical Characteristics for 3-V Supply(1) (continued) V+ = 2.7 V to 3.6 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX 20 30 UNIT Dynamic Turn-on time VNC = 2 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 3V tON Full 2.7 V to 3.6 V Turn-off time VNC = 2 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 3V tOFF Full 2.7 V to 3.6 V VGEN = 0, RGEN = 0, CL = 1 nF, See Figure 20 25°C 3V 1 35 15 ns 25 30 ns Charge injection QC NC OFF capacitance CNC(OFF) VNC = 0, f = 1 MHz, Switch OFF, See Figure 16 25°C 3V 6.5 pF COM OFF capacitance CCOM(OFF) VCOM = 0, f = 1 MHz, Switch OFF, See Figure 16 25°C 3V 6.5 pF NC ON capacitance CNC(ON) VNC = 0, f = 1 MHz, Switch ON, See Figure 16 25°C 3V 13 pF COM ON capacitance CCOM(ON) VCOM = 0, f = 1 MHz, Switch ON, See Figure 16 25°C 3V 13 pF CI VI = V+ or GND, See Figure 16 25°C 3V 3 pF BW RL = 50 Ω, Signal = 0 dBm, Switch ON, See Figure 18 25°C 3V 450 MHz Digital input capacitance Bandwidth 4 pC OFF isolation OISO RL = 50 Ω, CL = 5 pF, f = 1 MHz, VNC = 1 VRMS, Switch OFF, See Figure 19 25°C 3V −82 dB Total harmonic distortion THD RL = 600 Ω, CL = 50 pF, VSOURCE = 3 Vp-p, f = 20 Hz to 20 kHz, See Figure 21 25°C 3V 0.09 % Supply 25°C Positive supply I+ VI = V+ or GND, Switch ON or OFF 3.6 V current Full (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 6 0.01 0.25 0.5 µA A W www.ti.com SCDS180 − FEBRUARY 2005 TYPICAL PERFORMANCE 10 8 TA = 25_C 8 6 855C 255C 6 ron (W) ron (Ω) V+ = 3 V 4 4 –405C V+ = 5 V 2 2 0 0 0 1 2 3 4 5 0 1 2 VCOM (V) 5 Figure 2. ron vs VCOM (V+ = 5 V) 1.0 10 ICOM(ON)/INO(ON) –405C 0.8 Leakage Current (nA) 8 ron (W) 4 VCOM (V) Figure 1. ron vs VCOM 6 4 255C 855C 2 0.6 INO(OFF)/ICOM(OFF) 0.4 0.2 0.0 0 0 1 2 3 VCOM (V) −40°C 25°C TA (°C) 85°C Figure 4. Leakage Current vs Temperature (V+ = 5 V) Figure 3. ron vs VCOM (V+ = 3 V) 2.0 20 1.5 18 tON 1.0 tOFF 16 0.5 tON/tOFF (ns) Charge Injection (pC) 3 V+ = 5 V 0.0 V+ = 3 V −0.5 14 12 −1.0 10 −1.5 8 −2.0 6 0 1 2 3 Bias Voltage (V) 4 Figure 5. Charge-Injection (QC) vs VCOM 5 0 1 2 3 V+ (V) 4 5 6 Figure 6. tON and tOFF vs Supply Voltage 7 W www.ti.com SCDS180 − FEBRUARY 2005 TYPICAL PERFORMANCE (continued) 12 Logic Level Threshold (nA) 3 tON/tOFF (ns) 11 10 9 tON 8 7 tOFF 6 −40°C 25°C VIH 2 1 VIL 0 0 85°C 1 2 TA (5C) Figure 7. tON and tOFF vs Temperature (V+ = 5 V) 4 5 6 Figure 8. Logic-Level Threshold vs V+ 0.0 0 −0.5 −10 −20 Attenuation (dB) −1.0 Gain (dB) 3 V+ (V) −1.5 −2.0 −2.5 −3.0 −3.5 −30 −40 −50 −60 −70 −80 −90 −4.0 0.1 1 10 Frequency (MHz) 100 −100 0.1 1000 Figure 9. Bandwidth (Gain vs Frequency) (V+ = 5 V) 1 10 Frequency (MHz) 100 1000 Figure 10. OFF Isolation vs Frequency 10 0.20 V+ = 5 V 9 8 0.15 7 5 V+ = 3 V 4 3 2 THD (%) I+ (µA) 6 0.10 V+ = 3 V 0.05 V+ = 5 V 1 0 −40°C 25°C 85°C TA (5C) Figure 11. Power-Supply Current vs Temperature 8 0.00 0.1 1 10 100 1000 Frequency (MHz) Figure 12. Total Harmonic Distortion vs Frequency W www.ti.com SCDS180 − FEBRUARY 2005 PIN DESCRIPTION PIN NUMBER NAME 1 COM 2 NC 3 GND DESCRIPTION Common Normally closed Digital ground 4 IN Digital control pin to connect COM to NC 5 V+ Power supply PARAMETER DESCRIPTION SYMBOL DESCRIPTION VCOM Voltage at COM VNC Voltage at NC ron Resistance between COM and NC ports when the channel is ON ron(flat) Difference between the maximum and minimum value of ron in a channel over the specified range of conditions INC(OFF) Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the OFF state INC(ON) Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the ON state and the output (COM) open ICOM(OFF) Leakage current measured at the COM port, with the corresponding channel (COM to NC) in the OFF state ICOM(ON) Leakage current measured at the COM port, with the corresponding channel (COM to NC) in the ON state and the output (NC) open VIH Minimum input voltage for logic high for the control input (IN) VIL Maximum input voltage for logic low for the control input (IN) VI Voltage at the control input (IN) IIH, IIL Leakage current measured at the control input (IN) tON Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation delay between the digital control (IN) signal and analog output (COM or NC) signal when the switch is turning ON. tOFF Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation delay between the digital control (IN) signal and analog output (COM or NC) signal when the switch is turning OFF. QC Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NC or COM) output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control input. Charge injection, QC = CL × ∆VCOM, CL is the load capacitance, and ∆VCOM is the change in analog output voltage. CNC(OFF) CNC(ON) Capacitance at the NC port when the corresponding channel (NC to COM) is OFF CCOM(OFF) CCOM(ON) Capacitance at the COM port when the corresponding channel (COM to NC) is OFF CI Capacitance of control input (IN) OISO OFF isolation of the switch is a measurement of OFF-state switch impedance. This is measured in dB in a specific frequency, with the corresponding channel (NC to COM) in the OFF state. BW Bandwidth of the switch. This is the frequency in which the gain of an ON channel is −3 dB below the DC gain. THD Total harmonic distortion describes the signal distortion caused by the analog switch. This is defined as the ratio of root mean square (RMS) value of the second, third, and higher harmonic to the absolute magnitude of the fundamental harmonic. I+ Static power-supply current with the control (IN) pin at V+ or GND Capacitance at the NC port when the corresponding channel (NC to COM) is ON Capacitance at the COM port when the corresponding channel (COM to NC) is ON 9 W www.ti.com SCDS180 − FEBRUARY 2005 PARAMETER MEASUREMENT INFORMATION V+ VNC NC COM + VCOM Channel ON r on + VI ICOM IN VCOM * VNC W ICOM VI = VIH or VIL + GND Figure 13. ON-State Resistance (ron) V+ VNC NC COM + VI VCOM + OFF-State Leakage Current Channel OFF VI = VIH or VIL IN + GND Figure 14. OFF-State Leakage Current (ICOM(OFF), INC(OFF)) V+ VNC NC COM + VI VCOM ON-State Leakage Current Channel ON VI = VIH or VIL IN + GND Figure 15. ON-State Leakage Current (ICOM(ON), INC(ON)) 10 W www.ti.com SCDS180 − FEBRUARY 2005 V+ VNC NC VBIAS = V+ or GND Capacitance Meter VI = VIH or VIL f = 1 MHz VCOM COM VBIAS Capacitance is measured at NC, COM, and IN inputs during ON and OFF conditions. IN VI GND Figure 16. Capacitance (CI, CCOM(OFF), CCOM(ON), CNC(OFF), CNC(ON)) V+ NC (3) VCOM VI VNC TEST RL CL tON 300 Ω 35 pF tOFF 300 Ω 35 pF COM CL(2) RL IN Logic Input(1) V+ Logic Input (VI) GND 50% 50% 0 tON tOFF Switch Output (VCOM) 90% 90% (1) All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns. (2) CL includes probe and jig capacitance. (3) See Electrical Characteristics for VCOM. Figure 17. Turn-On (tON) and Turn-Off Time (tOFF) V+ Network Analyzer 50 W VNC NC Channel ON: NC to COM COM VCOM Source Signal VI = V+ or GND Network Analyzer Setup 50 W VI + IN Source Power = 0 dBm (632-mV P-P at 50-W load) GND DC Bias = 350 mV Figure 18. Bandwidth (BW) 11 W www.ti.com SCDS180 − FEBRUARY 2005 V+ Network Analyzer Channel OFF: NC to COM 50 W VNC NC VI = V+ or GND COM Source Signal VCOM Network Analyzer Setup VI 50 W Source Voltage = 1 VRMS IN + DC Bias = 350 mV GND Figure 19. OFF Isolation (OISO) V+ RGEN VGEN Logic Input (VI) VIH OFF ON OFF V IL NC COM + VCOM ∆VCOM VCOM CL(1) VI VGEN = 0 to V+ RGEN = 0 CL = 1 nF QC = CL × ∆VCOM VI = VIH or VIL IN Logic Input(2) GND (1) CL includes probe and jig capacitance. (2) All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns. Figure 20. Charge Injection (QC) Channel ON: COM to NC VSOURCE = V+ P-P LP Filter = 80 kHz VI = V+/2 or −V+/2 fSOURCE = 20 Hz to 20 kHz HP Filter = 10 Hz RL = 600 Ω CL = 50 pF V+/2 Audio Analyzer NC Source Signal COM CL(1) 600 W VI 600 W IN GND −V+/2 (1) CL includes probe and jig capacitance. Figure 21. Total Harmonic Distortion (THD) 12 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2008, Texas Instruments Incorporated