Filename: tfs 150s.doc Version 1.5 VI TELEFILTER 22.04.2005 Filter specification TFS 150S 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 25 02 °C dBm 330 Ω || -13,6 pF 300 Ω || -14,6 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 150S is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 21,6 Nominal frequency fN - Centre frequency fC 150 PB Passband dB max. 25 150,0 MHz dB MHz 150,0±0,1 MHz - fC 0,25 Pass band ripple (p-p) ±2,5015 MHz max. 0,7 dB MHz MHz MHz MHz min. min. max. max. 5,03 5,35 7,50 9,70 MHz MHz MHz MHz 0,25 1,5 65 20 45 55 60 2,58 dB dB dB dB dB dB dB µs max. max. min. min. min. min. min. max. 44 ns max. BW Bandwidth 0,7 dB 3 dB 40 dB 45 dB Relative attenuation fC … fC ± 2,5015 MHz … fC ± fC ± 144,500 MHz … fC fC 3,150 MHz … fC ± fC ± 3,350 MHz … fC ± fC ± 3,750 MHz … fC ± fC ± 4,825 MHz … fC + fC + Absolute group delay within PB tolerance / limit 5,20 5,53 6,49 6,54 2,5015 2,675 4,825 3,350 3,750 4,825 428,500 arel MHz MHz MHz MHz MHz MHz MHz Group delay ripple within PB (p-p) Operating temperature range OTR Frequency inversion temperature TCf ** 120 dB dB dB dB dB dB dB µs ns - 25 °C ... + 80°C - Storage temperature range Temperature coefficient of frequency - 0,7 3,0 45 15 25 40 45 2,7 - 40 °C ... + 85°C 20 °C -0,036 ppm/K 2 - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K2) x (T - TA)2 x fCAT (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150s.doc Version 1.5 VI TELEFILTER 22.04.2005 Filter specification TFS 150S 2/5 0 3.09 -1 3.03 -16 -2 2.97 -24 -3 2.91 -4 2.85 -5 2.79 -6 2.73 -56 -7 2.67 -64 -8 2.61 -9 2.55 -32 -40 -48 -72 -80 141 142.8 144.6 146.4 148.2 150 151.8 153.6 155.4 157.2 frequency in MHz 159 delay in µs 0 -8 magnitude in dB magnitude in dB Filter characteristic 2.49 -10 147 147.6 148.2 148.8 149.4 150 150.6 151.2 151.8 152.4 153 frequency in MHz Construction and pin connection (All dimensions in mm) TFS 150S ● T17 13 Max. 22,5 Max. 1 2 7 8 9 14 Input RF Return Ground Output RF Return Output Ground Input Date code: T U V ... Year + week 2005 2006 2007 Date code 7 1 6 Max. 4,5 Min. 7,62+ /-0,2 5 Max. 1 Dia.0,45+ /-0,05 10,16+ /-0,2 14 15,24+ /-0,2 8 50 Ω Test circuit 14 8 1, 2, 7, 9 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150s.doc Version 1.5 VI TELEFILTER Filter specification 22.04.2005 TFS 150S 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150s.doc Version 1.5 VI TELEFILTER 22.04.2005 Filter specification TFS 150S 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150s.doc VI TELEFILTER Version 1.5 Filter specification 22.04.2005 TFS 150S 5/5 History Version Reason of changes Name Date 1.0 - generation of development specification Strehl 20.01.2005 1.1 Strehl 04.02.2005 1.2 - change passband add typ. 3dB bandwidth - change relative attenuation Strehl 14.02.2005 1.3 - ‘remarks’ corrected Pfeiffer 15.02.2005 1.4 - change insertion loss - change absolute group delay Strehl 07.04.2005 1.5 - terminating impedance, typical values and filter characteristic added - matching configuration modified Pfeiffer 22.04.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.