VECTRON TFS150S

Filename: tfs 150s.doc
Version 1.5
VI TELEFILTER
22.04.2005
Filter specification
TFS 150S
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25
02
°C
dBm
330 Ω || -13,6 pF
300 Ω || -14,6 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 150S is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the
production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
21,6
Nominal frequency
fN
-
Centre frequency
fC
150
PB
Passband
dB
max.
25
150,0
MHz
dB
MHz
150,0±0,1 MHz
-
fC
0,25
Pass band ripple (p-p)
±2,5015
MHz
max.
0,7
dB
MHz
MHz
MHz
MHz
min.
min.
max.
max.
5,03
5,35
7,50
9,70
MHz
MHz
MHz
MHz
0,25
1,5
65
20
45
55
60
2,58
dB
dB
dB
dB
dB
dB
dB
µs
max.
max.
min.
min.
min.
min.
min.
max.
44
ns
max.
BW
Bandwidth
0,7 dB
3
dB
40
dB
45
dB
Relative attenuation
fC
… fC ±
2,5015 MHz … fC ±
fC ±
144,500 MHz … fC fC 3,150 MHz … fC ±
fC ±
3,350 MHz … fC ±
fC ±
3,750 MHz … fC ±
fC ±
4,825 MHz … fC +
fC +
Absolute group delay within PB
tolerance / limit
5,20
5,53
6,49
6,54
2,5015
2,675
4,825
3,350
3,750
4,825
428,500
arel
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Group delay ripple within PB (p-p)
Operating temperature range
OTR
Frequency inversion temperature
TCf **
120
dB
dB
dB
dB
dB
dB
dB
µs
ns
- 25 °C ... + 80°C
-
Storage temperature range
Temperature coefficient of frequency
-
0,7
3,0
45
15
25
40
45
2,7
- 40 °C ... + 85°C
20
°C
-0,036
ppm/K
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K2) x (T - TA)2 x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 150s.doc
Version 1.5
VI TELEFILTER
22.04.2005
Filter specification
TFS 150S
2/5
0
3.09
-1
3.03
-16
-2
2.97
-24
-3
2.91
-4
2.85
-5
2.79
-6
2.73
-56
-7
2.67
-64
-8
2.61
-9
2.55
-32
-40
-48
-72
-80
141
142.8 144.6 146.4 148.2 150 151.8 153.6 155.4 157.2
frequency in MHz
159
delay in µs
0
-8
magnitude in dB
magnitude in dB
Filter characteristic
2.49
-10
147 147.6 148.2 148.8 149.4 150 150.6 151.2 151.8 152.4 153
frequency in MHz
Construction and pin connection
(All dimensions in mm)
TFS 150S
●
T17
13 Max.
22,5 Max.
1
2
7
8
9
14
Input RF Return
Ground
Output RF Return
Output
Ground
Input
Date code:
T
U
V
...
Year + week
2005
2006
2007
Date code
7
1
6 Max.
4,5 Min.
7,62+ /-0,2
5 Max.
1 Dia.0,45+ /-0,05
10,16+ /-0,2
14 15,24+ /-0,2 8
50 Ω Test circuit
14
8
1, 2, 7, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 150s.doc
Version 1.5
VI TELEFILTER
Filter specification
22.04.2005
TFS 150S
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan,
3 plans; DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 150s.doc
Version 1.5
VI TELEFILTER
22.04.2005
Filter specification
TFS 150S
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 150s.doc
VI TELEFILTER
Version 1.5
Filter specification
22.04.2005
TFS 150S
5/5
History
Version
Reason of changes
Name
Date
1.0
- generation of development specification
Strehl
20.01.2005
1.1
Strehl
04.02.2005
1.2
- change passband
add typ. 3dB bandwidth
- change relative attenuation
Strehl
14.02.2005
1.3
- ‘remarks’ corrected
Pfeiffer
15.02.2005
1.4
- change insertion loss
- change absolute group delay
Strehl
07.04.2005
1.5
- terminating impedance, typical values and filter characteristic added
- matching configuration modified
Pfeiffer
22.04.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.