TI TPSV477M010R0060

PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
60-A, 3.3/5-V INPUT, NONISOLATED WIDE-OUTPUT
ADJUST POWER MODULE
FEATURES
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
60-A Output Current
3.3-V and 5-V Input Voltage
Wide-Output Voltage Adjust (0.8 V to 2.5 V)
Efficiencies up to 93%
On/Off Inhibit
Differential Output Sense
Output Overcurrent Protection
(Nonlatching, Auto-Reset)
Overtemperature Protection
Auto-Track™ Sequencing
Start Up Into Output Prebias
Margin Up/Down Controls
Operating Temperature: –40°C to 85°C
Multi-Phase, Switch-Mode Topology
Programmable Undervoltage Lockout (UVLO)
Safety Agency Approvals: UL/cUL 60950,
EN60950, VDE (Pending)
Advanced Computing and Server Applications
NOMINAL SIZE =
2.05 in x 1.05 in
(52 mm x 26,7 mm)
DESCRIPTION
The PTH04040W is a high-performance 60-A rated, nonisolated, power module, which uses the latest
multi-phase switched-mode topology. This provides a small, ready-to-use module, that can power the most
densely populated multiprocessor systems.
The PTH04040W operates over an input voltage range of 2.95 V to 5.5 V, and can be set to any output voltage
over the range, 0.8 V to 2.5 V, using a single external resistor. The combination of a wide input voltage and
wide-output adjust range allows the PTH04040W to be used in many of high-performance applications. These
include advanced computing platforms and servers that utilize either a 3.3-V or 5-V distribution bus.
These modules incorporate a comprehensive list of features. They include an on/off inhibit and margin up/down
controls. A differential remote output voltage sense ensures tight load regulation, and an output overcurrent and
overtemperature shutdown protect against most load faults. A programmable undervoltage lockout allows the
turn-on threshold to be customized.
The PTH04040W incorporates Auto-Track™. Auto-Track is a popular feature of the PTH family that allows the
outputs of multiple modules to track a common voltage during power-up and power-down transitions. This greatly
simplifies the sequencing of voltages for VLSI ICs that operate off multiple power rails.
The double-sided surface mount construction has a low profile and compact footprint. It is available in both
throughhole and surface-mount packages.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Auto-Track, POLA, TMS320 are trademarks of Texas Instruments.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2005–2006, Texas Instruments Incorporated
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
STANDARD APPLICATION
19
Margin
Up
2
VI
4
20
Margin
Down
8
+Sense
11
9
Vo
PTH04040W
12
VO
15
UVLO
Inhibit
A
Track
VI
6
+
18
CI
1000 µF
(Required)
7
GND
1
3
GND
5
10
13
−Sense
VoAdj
14
16 17
RSET B
1%
0.05 W
+
C
+
CO1
330 µF
C
CO2
330 µF
UDG−05085
A.
For CI, a minimum of 1,000 µF (or 2 × 470 µF) of input capacitance is required for proper operation.
B.
RSET is required to set the desired output voltage from the module higher than the minimum value.
C.
For CO1 and CO2, a minimum of 660 µF (or 2 × 330 µF) of input capacitance is required load transient regulation.
ORDERING INFORMATION
For the most current package and ordering information, see the Package Option Addendum at the end of this datasheet, or see
the TI website at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
UNIT
Signal input voltages
Track control (pin 18)
TA
Operating temperature range over VI range
Twave
Wave solder
temperature
Surface temperature of module body or pins (5
seconds)
Treflow
Solder reflow
temperature
Surface temperature of module body or pins
TS
Storage temperature
–40°C to 85°C
2
260°C
(1)
PTH04040WAS
235°C
(1)
PTH04040WAZ
260°C
(1)
Mechanical shock
Per Mil-STD-883D, Method 2002.3, 1 msec, 1/2 Sine, mounted
500 G (2)
Mechanical vibration
Mil-STD-883D, Method 2007.2, 20–2000 Hz
10 G (2)
Flammability
(2)
PTH04040WAH
–40°C to 125°C
Weight
(1)
–0.3 V to VI + 0.3 V
22.5 grams
Meets UL94V-O
During soldering of package version, do not elevate peak temperature of the module, pins or internal components above the stated
maximum.
Qualification limits
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
ELECTRICAL CHARACTERISTICS
TA = 25°C, VI = 5 V, VO = 2.5 V, CI = 1000 µF, CO = 660 µF, and IO = IOmax (unless otherwise stated)
PARAMETER
TEST CONDITIONS
MIN
MAX
UNIT
0
TYP
60 (1)
A
2.95 (2)
5.5
IO
Output current
60°C, 200 LFM airflow
VI
Input voltage range
Over IO range
VOtol
Set-point voltage tolerance
∆Regtemp
Temperature variation
–40°C < TA < 85°C
±0.5
%VO
∆Regline
Line regulation
Over VI range
±5
mV
∆Regload
Load regulation
Over IO range
±5
∆Regtot
Total output variation
Includes set-point, line, load, –40°C ≤ TA ≤ 85°C
VO,
Output adjust range
ADJ
±2 (3)
VI = 5 V, IO = 45 A
η
Efficiency
VI = 3.3 V, IO = 45 A
V
%VO
mV
±3 (3)
2.95 ≤ VI ≤ 4.5 V (3)
0.8
-
1.65
4.5 ≤ VI ≤ 5.5 V (3)
0.8
-
2.5
%VO
V
RSET = 2.21 kΩ, VO = 2.5 V
93%
RSET = 5.49 kΩ, VO = 1.8 V
90%
RSET = 8.87 kΩ, VO = 1.5 V
88%
RSET = 17.4 kΩ, VO = 1.2 V
86%
RSET = 6.92 kΩ, VO = 1.65 V
92%
RSET = 8.87 kΩ, VO = 1.5 V
91%
RSET = 36.5 kΩ, VO = 1 V
87%
All voltages
15
mVPP
90
A
VR
VO ripple (peak-to-peak)
20-MHz bandwidth
IOtrip
Overcurrent threshold
Reset, followed by auto-recovery
Transient response
1 A/µs load step, 50 to 100% IOmax, CO = 660 µF
trr
∆Vtr
Recovery time
100
µS
VO over/undershoot
200
mV
Margin up down adjust
From a given set-point voltage
±5%
%
IILmargin
Margin input current
Pin to GND
–8 (4)
µA
IILtrack
Track input current (pin 18)
Pin to GND
dV/dt
Track slew rate capability
|VTRACK – VO | ≤ 50 mV and V(TRACK) < VO(nom)
UVLO
Undervoltage lockout
Pin 8 open
Inhibit control (pin 7)
–0.11 (5)
1
On-threshold
2.6 (6)
Hysterisis
0.6 (6)
V
Referenced to GND
VIH
Input high voltage
2.5
Open (5)
VIL
Input low voltage
–0.2
0.5
IILinhibit
Input low current
Pin to GND
0.5
IIinh
Input standby current
Inhibit (pin 7) to GND
60
fs
Switching frequency
Over VI and IO ranges
CI
External input capacitance
(1)
(2)
(3)
(4)
(5)
(6)
(7)
mA
V/ms
675
940 (7)
825
V
mA
mA
975
kHz
µF
See SOA curves or consult factory for appropriate derating.
The nominal input voltage must be at least 2 × VO. Output voltage regulation is guaranteed with an input voltage within ±10% from
nominal 3.3 V or 5 V. For example, for VI = 5 V and VO = 2.5 V, the input can vary between 4.5 V and 5.5 V.
The set-point voltage tolerance is affected by the tolerance of RSET. The stated limit is unconditionally met if RSET has a tolerance of 1%
with 100 ppm/°C or better temperature stability.
A small, low-leakage (<100 nA) MOSFET is recommended to control this pin. The open-circuit voltage is less than 1 Vdc.
This control pin has an internal pull-up to VI. If it is left open-circuit the module operates when input power is applied. A small,
low-leakage (<100 nA) MOSFET or open-drain/collector voltage supervisor IC is recommended for control. Do not place an external
pull-up on this pin. See the Application Information section for further guidance.
These are the default voltages. They may be adjusted using the UVLO Prog control input. See the Application Information section for
further guidance.
A minimum capacitance of 940 µF is required at the input for proper operation. The capacitance must be rated for a minimum of 400
mArms of ripple current.
Submit Documentation Feedback
3
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
ELECTRICAL CHARACTERISTICS (continued)
TA = 25°C, VI = 5 V, VO = 2.5 V, CI = 1000 µF, CO = 660 µF, and IO = IOmax (unless otherwise stated)
PARAMETER
CO
External output capacitance
TEST CONDITIONS
Capacitance value
MIN
Nonceramic
Ceramic
Equivalent series resistance (nonceramic)
MTBF
Reliability
Per Bellcore TR-332 50% stress, TA = 40°C, ground benign
(8)
660 (8)
TYP
MAX
14000 (9)
400
UNIT
µF
2 (10)
mΩ
2.1
106Hrs
A minimum value of output capacitance is required for proper operation. Adding additional capacitance at the load will further improve
transient response.
(9) This is the calculated maximum. The minimum ESR requirement often results in a lower value. See the Application Information section
for further guidance.
(10) This is the typcial ESR for all the electrolytic (nonceramic) output capacitance. Use 4 mΩ as the minimum when using max-ESR values
to calculate.
4
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
DEVICE INFORMATION
TERMINAL FUNCTIONS
TERMINAL
NAME
GND
DESCRIPTION
NO.
1, 3, 5, 10, 13, This is the common ground connection for the VI and VO power connections. It is also the 0 Vdc
16
reference for the control inputs.
VI
2, 4, 6
VO
9, 12, 15
The positive input voltage power node to the module, which is referenced to common GND.
The regulated positive power output with respect to the GND node.
7
The Inhibit pin is an open-collector/drain negative logic input that is referenced to GND. Applying a
lowlevel ground signal to this input disables the module’s output and turns off the output voltage. When
the Inhibit control is active, the input current drawn by the regulator is significantly reduced. If the Inhibit
pin is left open-circuit, the module produces an output whenever a valid input source is applied. Do not
place an external pull-up on this pin.
VO Adjust
17
A 1%, 0.05-W resistor must be connected between this pin and GND to set the output voltage higher
than the minimum value. The set-point range for the output voltage is from 0.8 V to 2.5 V. The resistor
required for a given output voltage may be calculated from the following formula. If left open circuit, the
module output defaults to its lowest output voltage value. For further information on the adjustment
and/or trimming of the output voltage, see the related Application Information section. Note: The
specification table gives the preferred resistor values for a number of standard output voltages.
+Sense
11
The sense inputs allow the regulation circuit to compensate for voltage drop between the module and
the load. For optimal voltage accuracy, +Sense should be connected to VO. If it is left open, a low-value
internal resistor ensures that the output remains in regulation.
–Sense
14
For optimal voltage accuracy, –Sense should be connected to the ground return at the load. If it is left
open, a low-value internal resistor ensures that the output remains in regulation.
UVLO Prog
8
Connecting a resistor from this pin to signal ground allows the on threshold of the input undervoltage
lockout (UVLO) to be adjusted higher than the default value. The hysterisis can also be independenly
reduced by connecting a second resistor from this pin to VI. For further information, see the Application
Information section.
Track
18
This is an analog control input that allows the output voltage to follow another voltage during power up
and power down sequences. The pin is active from 0 V, up to the nominal set-point voltage. Within this
range, the module output follows the voltage at the Track pin on a volt-for-volt basis. When the control
voltage is raised above this range, the module regulates at its nominal output voltage. If unused, this
input should be connected to VI for a faster power up. For further information, see the related
Application Information section.
Margin Down (1)
20
When this input is asserted to GND, the output voltage is decreased by 5% from the nominal. The input
requires an open-collector (open-drain) interface. It is not TTL compatible. A lower percent change can
be accommodated with a series resistor. For further information, see the related Application Information
section.
Margin Up (1)
19
When this input is asserted to GND, the output voltage is increased by 5%. The input requires an open
collector (open-drain) interface. It is not TTL compatible. The percent change can be reduced with a
series resistor. For further information, see the related Application Information section.
Inhibit (1)
(1)
Denotes negative logic: Open = Normal operation; Ground = Function active
16
16
15 14 13
12 11 10
9
8
6
7
17
18
19
PTHXX040W
20
(Top View)
1
2
3
4
5
Submit Documentation Feedback
5
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
TYPICAL CHARACTERISTICS (VI = 3.3 V) (1) (2)
CHARACTERISTIC DATA
OUTPUT RIPPLE
vs
LOAD CURRENT
25
90
20
VO = 1 V
80
VO = 1.5 V
70
50
15
15
VO = 1.5 V
10
VO = 1 V
5
60
POWER DISSIPATION
vs
LOAD CURRENT
PD − Power Dissipation − W
100
Output Ripple − mV
Efficiency − %
EFFICIENCY
vs
LOAD CURRENT
0
0
10
20
30
40
50
0
60
10
20
30
40
50
60
IL − Load Current − A
IL − Load Current − A
Figure 1.
12
9
6
3
0
0
10
20
30
40
50
60
IL − Load Current − A
Figure 2.
Figure 3.
TEMPERATURE DERATING
vs
LOAD CURRENT
90
TA− Ambient Temperature −C
80
Nat Cinv
70
200 LFM
60
400 LFM
50
40
30
20
0
10
20
30
40
50
60
IL − Load Current − A
Figure 4.
(1)
(2)
6
The electrical characteristic data has been developed from actual products tested at 25°C. This data is considered typical for the
converter. Applies to Figure 1, Figure 2, and Figure 3.
SOA curves represent the conditions at which internal components are at or below the manufacturer’s maximum operating
temperatures. Derating limits apply to modules soldered directly to a 4 inchs × 4 inchs double-sided PCB with 1 oz. copper. Applies to
Figure 4.
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
TYPICAL CHARACTERISTICS (VI = 5 V) (1) (2)
EFFICIENCY
vs
LOAD CURRENT
OUTPUT RIPPLE
vs
LOAD CURRENT
POWER DISSIPATION
vs
LOAD CURRENT
25
100
15
VO = 2.5 V
Output Ripple − mV
Efficiency − %
80
VO = 1.8 V
VO = 1.5 V
VO = 1.2 V
70
VO = 1.8 V
10
VO = 1.2 V
5
60
50
15
PD − Power Dissipation − W
20
90
0
0
10
20
30
40
50
60
0
10
20
30
40
IL − Load Current − A
IL − Load Current − A
Figure 5.
Figure 6.
50
60
12
VO = 1.8 V
9
6
VO = 1.2 V
3
0
0
10
20
30
40
50
60
IL − Load Current − A
Figure 7.
TEMPERATURE DERATING
vs
LOAD CURRENT
90
TA− Ambient Temperature −C
80
Nat Cinv
70
60
200 LFM
50
400 LFM
40
30
VI = 5 V
20
0
10
20
30
40
50
60
IL − Load Current − A
Figure 8.
(1)
(2)
The electrical characteristic data has been developed from actual products tested at 25°C. This data is considered typical for the
converter. Applies to Figure 5, Figure 6, and Figure 7.
SOA curves represent the conditions at which internal components are at or below the manufacturer’s maximum operating
temperatures. Derating limits apply to modules soldered directly to a 4 inchs × 4 inchs double-sided PCB with 1 oz. copper. Applies to
Figure 8.
Submit Documentation Feedback
7
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
APPLICATION INFORMATION
CAPACITOR RECOMMENDATIONS FOR THE PTH04040W POWER MODULE
The PTH04040W uses state-of-the-art multi-phase power converter topology that employs multiple parallel
switching and filter inductor paths between the input and output capacitors. The PTH04040W uses three
switching paths. The three paths share the total load current, operate at the same frequency, and are evenly
displaced in phase.
With multiple switching paths the transient output current capability is significantly increased. This reduces the
amount of external output capacitance required to support a load transient. The ripple current, as seen by the
input and output capacitors, is reduced in magnitude and effectively tripled in frequency.
INPUT CAPACITOR
The improved transient response of a multi-phase converter places a bigger burden on the transient capability of
the input source. The size and value of the input capacitor is therefore determined by this converter’s transient
performance capability. The minimum amount of input capacitance required is 940 µF (2 × 470 µF or 3 × 330 µF),
with an RMS ripple current rating of 400 mA. This minimum value assumes that the converter is supplied with a
responsive, low-inductance input source. This source should have ample capacitive decoupling and be
distributed the converter via PCB power and ground planes. For highperformance applications, or wherever the
transient capability of the input source is limited, 2,200 µF of input capacitance is recommended.
Ripple current and less than 100 mΩ equivalent series resistance (ESR) values are the major considerations,
along with temperature, when designing with different types of capacitors. Unlike polymer tantalum, conventional
tantalum capacitors have a recommended minimum voltage rating of 2 × (maximum dc voltage + ac ripple). This
is standard practice to ensure reliability.
For improved ripple reduction on the input bus, ceramic capacitors may be used to complement electrolytic types
and achieve the minimum required capacitance.
OUTPUT CAPACITORS RECOMMENDED
In order to respond with load transients (sudden changes in load current) the regulator requires external output
capacitance. The minimum output capacitance is 660 µF (2 × 330 µF or 1 × 680 µF) with an ESR of at least
2 mΩ. This output capacitance is required for the module to meet its transient response specification. For most
applications, a high quality computer grade aluminum electrolytic capacitor is suitable. These capacitors provide
adequate decoupling over the frequency range, 2 kHz to 150 kHz, and when ambient temperatures are above
0°C. For operation below 0°C, tantalum, ceramic, or Os-Con type capacitors are recommended.
When using one or more nonceramic capacitors, the calculated equivalent ESR should be no lower than 4 mΩ
7 mΩ using the manufacturer’s maximum ESR for a single capacitor. A list of preferred low-ESR type capacitors
are identified in Table 1.
CERAMIC CAPACITORS
Above 150 kHz, the performance of aluminum electrolytic capacitors becomes less effective. To further improve,
the reflected input ripple current or the output transient response, multilayer ceramic capacitors can also be
added. Ceramic capacitors have very low ESR and their resonant frequency is higher than the bandwidth of the
regulator. When used on the output their combined ESR is not critical as long as the total value of ceramic
capacitance does not exceed 300 µF. Also, to prevent the formation of local resonances, do not place more than
five identical ceramic capacitors in parallel with values of 10 µF or greater..
TANTALUM CAPACITORS
Tantalum type capacitors can be used at both the input and output, and are recommended for applications where
the ambient operating temperature can be less than 0°C. The AVX TPS, Sprague 593D/594/595, and Kemet
T495/ T510 capacitor series are suggested over many other tantalum types due to their higher rated surge,
power dissipation, and ripple current capability. As a caution, many general-purpose tantalum capacitors have
considerably higher ESR, reduced power dissipation and lower ripple current capability. These capacitors are
also less reliable when determining their power dissipation and surge current capability. Tantalum capacitors that
do not have a stated ESR or surge current rating are not recommended for power applications.
8
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
APPLICATION INFORMATION (continued)
When specifying Os-Con and polymer tantalum capacitors for the output, the minimum ESR limit is encountered
before the maximum capacitance value is reached.
CAPACITOR TABLE
Table 1 identifies the characteristics of capacitors from a number of vendors with acceptable ESR and ripple
current (rms) ratings. The recommended number of capacitors required at both the input and output buses is
identified for each capacitor type.
Note: This is not an extensive capacitor list. Capacitors from other vendors are available with comparable
specifications. Those listed are for guidance. The RMS ripple current rating and ESR (at 100kHz) are critical
parameters necessary to insure both optimum regulator performance and long capacitor life.
DESIGNING FOR VERY FAST LOAD TRANSIENTS
The transient response of the dc/dc converter has been characterized using a load transient with a di/dt of
1 A/µs. The typical voltage deviation for this load transient is given in the data sheet specification table using the
minimum required value of output capacitance. As the di/dt of a transient is increased, the response of a
converter’s regulation circuit ultimately depends on its output capacitor decoupling network. This is an inherent
limitation with any dc/dc converter once the speed of the transient exceeds its bandwidth capability. If the target
application specifies a higher di/dt or lower voltage deviation, the requirement can only be met with additional
output capacitor decoupling. In these cases special attention must be paid to the type, value and ESR of the
capacitors selected. Additional input capcitance may be requried to insure the stability of the input bus during
higher current transient di/dt.
Submit Documentation Feedback
9
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
APPLICATION INFORMATION (continued)
Table 1. Input/Output Capacitors (1)
Capacitor Characteristics
Capacitor Vendor,
Type Series (Style)
Quantity
Working
Voltage
Value
(µF)
Max. ESR
at 100 kHz
Max Ripple
Current at
85°C (I rms)
10 V
10 V
10 V
1000
1000
1000
0.068 Ω
0.0650 Ω
0.080 Ω
>1050 mA
1205 mA
850 mA
10 × 16
12.5 × 16.5
10 × 10.2
1
1
1
1
1
1
EEUFC1A102
EEVFC1A102LQ
EEVFK1A102P
6.3 V
6.3 V
10 V
10 V
1000
820
680
1000
0.013 Ω
0.010 Ω
0.007 Ω
0.068 Ω
4935 mA
5500 mA
>5800 mA
1050 mA
10 × 10.5
10 × 12.2
10 × 11.5
10 × 16
1
2
2
1
1
1
≤3
1
6FX1000M
PXA6.3VC820MJ12TP
PSA6.3VB680MJ11
LXZ10VB102M10X16LL
6.3 V
10 V
1000
1000
0.053 Ω
0.065 Ω
1030 mA
1040 mA
10 × 12.5
12.5 × 15
1
1
1
1
UHD0J102MPR
UPM1A102MHH6
SP, (Radial)
SVP, (SMD)
10 V
6.3 V
470
820
0.015 Ω
0.012 Ω
>4500 mA
>5440 mA
10x10.5
10x12.7
2 (2)
2
≤5
≤ 43
10SP470M
6SVP820M
Panasonic, Poly-Aluminum:
S/SE (SMD)
63 V
180
0.005 Ω
4000 mA
7.3x4.3x4.2
N/R
≤2
EEFSE0J181R
10 V
10 V
470
470
0.045 Ω
0.060 Ω
1723 mA
1826 mA
7,3 L
× 5,7 W
× 4,1 H
2 (2)
2 (2)
≤7
≤7
TPSE477M010R0045
TPSV477M010R0060
6.3 V
10 V
6.3 V
470
330
470
0.018 Ω
0.015 Ω
0.012 Ω
>1200 mA
>3800 mA
4200 mA
4,3 W
× 7.3 L
×4H
2 (2)
3
2 (2)
≤6
≤4
≤3
T520X477M006SE018
T530X337M010AS
T530X477M006AS
595D, Tantalum (SMD)
94SA, Os-con (Radial)
10 V
16 V
470
2200
0.100 Ω
0.015 Ω
1440 mA
9740 mA
× 4.1 H
16 × 25
2 (2)
1
≤7
≤4
595D477X0010R2T
94SA108X0016HBP
Kemet, Ceramic X5R (SMD)
16 V
6.3 V
10
47
0.002 Ω
0.002 Ω
–
1210 case
3225 mm
1 (3)
1 (3)
≤9
≤8
C1210C106M4PAC
C1210C476K9PAC
Murata, Ceramic X5R (SMD)
6.3 V
6.3 V
16 V
16 V
100
47
22
10
0.002 Ω
–
1210 case
3225 mm
1 (3)
1 (3)
1 (3)
≤4
≤8
≤8
≤9
GRM32ER60J107M
GRM32ER60J476M
GRM32ER61C226K
GRM32DR61C106K
TDK, Ceramic X5R (SMD)
6.3 V
6.3 V
16 V
16 V
100
47
22
10
0.002 Ω
–
1210 case
3225 mm
1 (3)
1 (3)
1 (3)
≤4
≤8
≤8
≤9
C3225X5R0J107MT
C3225X5R0J476MT
C3225X5R1C226MT
C3225X5R1C106MT
Physical
Size (mm)
Input
Bus
Output
Bus
Vendor Part No.
Panasonic
FC (Radial)
FK (SMD)
United Chemi-Con
FX, Oscon (Radial)
PXA, (Poly-Aluminum (SMD)
PSA (Poly-Aluminum)
LXZ, Aluminum (Radial)
Nichicon, Aluminum
HD (Radial)
PM (Radial)
Sanyo, Os-Con
AVX, Tantalum, Series III
TPS (SMD)
Kemet, Poly-Tantalum
T520 (SMD)
T530 (SMD)
7.2 L × 6 W
Vishay-Sprague
(1)
(2)
(3)
10
Capacitor Supplier Verification
1.Please verify availability of capacitors identified in this table. Capacitor suppliers may recommend alternative part numbers because of
limited availability or obsolete products. In some instances, the capacitor product life cycle may be in decline and have short-term
consideration for obsolescence.
RoHS, Lead-free and Material Details
2.Please consult capacitor suppliers regarding material composition, RoHS status, lead-free status, and manufacturing process
requirements. Component designators or part number deviations can occur when material composition or soldering requirements are
updated.
The total capacitance is slightly lower than 1000 µF, but is acceptable based on the combined ripple current rating.
Ceramic capacitors can be used to complement electrolytic types at the input to further reduce high-frequency ripple current.
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
ADJUSTING THE OUTPUT VOLTAGE OF THE PTH04040W WIDE-OUTPUT ADJUST POWER
MODULE
The VO Adjust control (pin 17) sets the output voltage of the PTH04040W to a value higher than 0.8 V. The
adjustment range is from 0.8 V to 2.5 V. For an output voltage other than 0.8 V a single external resistor, RSET 1,
must be connected directly between the VO Adjust (pin 17) and the output GND (pin 16)(2). Table 2 gives the
preferred value of the external resistor for a number of standard voltages, along with the actual output voltage
that this resistance value provides.
For other output voltages, the value of the required resistor is calculated using the following formula, or by
selecting from the range of values given in Table 3. Figure 9 shows the placement of the required resistor.
0.8 V
R set 10 k 2.49 k
V out 0.8 V
(1)
Table 2. Preferred Values of Rset for Standard Output Voltages
VOUT (Standard)
(1)
(1)
RSET (Preferred Value)
VOUT (Actual)
2.5 V
2.21 Ω
2.502 V
2V
4.12 Ω
2.010 V
1.8 V
5.49 Ω
1.803 V
1.5 V
8.87 Ω
1.504 V
1.2 V
17.4 Ω
1.202 V
1V
36.5 Ω
1.005 V
0.8 V
Open
0.8 V
The nominal input voltage must be at least 2 × VO. Output voltage regulation is guaranteed with an input voltage within ±10% from
nominal 3.3 V or 5 V. For example, for VI = 5 V and VO = 2.5 V, the input can vary between 4.5 V and 5.5 V.
18
Track
+Sense 11
9
VO
PTH04040W
VO
12
15
−Sense 14
GND
10 13
Adjust
16
17
RSET
1%
0.05 W
CO
GND
GND
Figure 9. VO Adjust Resistor Placement
Submit Documentation Feedback
11
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
Table 3. Output Voltage Set-Point Resistor Values
VOUT
RSET
VOUT
RSET
0.8
Open
1.425
10.3 kΩ
0.825
318 kΩ
1.45
9.82 kΩ
0.85
158 kΩ
1.475
9.36 kΩ
0.875
104 kΩ
1.5
8.94 kΩ
0.9
77.5 kΩ
1.55
8.18 kΩ
0.925
61.5 kΩ
1.6
7.51 kΩ
0.95
50.8 kΩ
1.65
6.92 kΩ
0.975
43.2 kΩ
1.7
6.4 kΩ
1
37.5 kΩ
1.75
5.93 kΩ
1.025
33.1 kΩ
1.8
5.51 kΩ
1.05
29.5 kΩ
1.85
5.13 kΩ
1.075
26.6 kΩ
1.9
4.78 kΩ
1.1
24.2 kΩ
1.95
4.47 kΩ
1.125
22.1 kΩ
2
4.18 kΩ
1.15
20.4 kΩ
2.05
3.91kΩ
1.175
18.8 kΩ
2.1
3.66 kΩ
1.2
17.5 kΩ
2.15
3.44 kΩ
1.225
16.3 kΩ
2.2
3.22 kΩ
1.25
15.3 kΩ
2.25
3.03 kΩ
1.275
14.4 kΩ
2.3
2.84 kΩ
1.3
13.5 kΩ
2.35
2.67 kΩ
1.325
12.7 kΩ
2.4
2.51 kΩ
1.35
12.1 kΩ
2.45
2.36 kΩ
1.375
11.4 kΩ
2.5
2.22 kΩ
1.4
10.8 kΩ
NOTES:
1. A 0.05-W rated resistor can be used. The tolerance should be 1%, with temperature stability of 100 ppm/°C
(or better). Place the resistor as close to the regulator as possible. Connect the resistor directly between pins
17 and 16 using dedicated PCB traces.
2. Never connect capacitors from VO Adjust to either GND or VO. Any capacitance added to the VO Adjust pin
affects the stability of the regulator.
ADJUSTING THE UNDERVOLTAGE LOCKOUT (UVLO) OF THE PTH04040W POWER MODULES
The PTH04040W power modules incorporate an input undervoltage lockout (UVLO). The UVLO feature prevents
the operation of the module until there is sufficient input voltage to produce a valid output voltage. This enables
the module to provide a monotonic powerup for the load circuit, and also limits the magnitude of current drawn
from the module’s input source during the power-up sequence.
The UVLO characteristic is defined by the on-threshold (VTHD) and hysterisis (VHYS) voltages. Below the on
threshold, the Inhibit control is overriden, and the module does not produce an output. Hysterisis voltage is the
difference between the on and off threshold voltages. It ensures a clean power-up, even when the input voltage
is rising slowly. The hysterisis prevents start-up oscillations, which can occur if the input voltage droops slightly
when the module begins drawing current from the input source.
12
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
UVLO ADJUSTMENT
The UVLO feature of the PTH04040W gives the user the option of adjusting the on-threshold voltage higher than
the default value. This might be desirable if the module is powered from a 5-V input bus. This prevents the
module from operating until the input bus has risen closer to its regulation voltage.
The adjustment method uses the UVLO Prog control (pin 8). If the UVLO Prog pin is left open circuit, the
onthreshold voltage remains at its nominal value of 2.63 V (see electrical specification table). This ensures that
the unadjusted module produces a regulated output when the minimum input voltage is applied. The hysterisis
voltage is approximately 0.62 V, which correlates to an off-threshold voltage of about 2 V. The magnitude of the
hysterisis is automatically set to about 22% of the onthreshold. So if the on-threshold voltage is increased, then
the hystersis also increases.
ADJUSTMENT METHOD
Figure 10 shows the placement of the resistor, RTHD, for adjusting the UVLO on-threshold voltage. It connects
from the UVLO Prog control pin to GND. Equation 2 determines the value of RTHD required to adjust VTHD to a
new value. The default value is 2.63 V, and it can only be adjusted higher. Once the value of RTHD has been set,
Equation 3 is used to determine the new hystersis voltage.
R THD
12.9
=
kΩ
VTHD − 2.63
VHYS = 2.191
1
R THD
(2)
+ 0.283
V
(3)
2
VI
4
6
8
VI
PTH04040W
UVLO Prog
Inhibit
7
CI
GND
1
3 5
RTHD
1,000 mF
GND
Figure 10. UVLO Program Resistor Placement
FEATURES OF THE PTH FAMILY OF NONISOLATED WIDE OUTPUT ADJUST POWER
MODULES
POLA™ COMPATIBILITY
The PTH/PTV family of nonisolated, wide-output adjustable power modules are optimized for applications that
require a flexible, high performance module that is small in size. Each of these products are POLA™ compatible.
POLA-compatible products are produced by a number of manufacturers, and offer customers advanced,
nonisolated modules with the same footprint and form factor. POLA parts are also assured to be interoperable,
thereby providing customers with second-source availability.
Many of the POLA-compatible parts include a feature called Auto-Track™. Auto-Track was specifically designed
to simplify the task of sequencing the supply voltages in a power system. This and other features are described
the following sections.
Soft-Start Power Up
The Auto-Track feature allows the power-up of multiple PTH modules to be directly controlled from the Track pin.
However in a stand-alone configuration, or when the Auto-Track feature is not being used, the Track pin should
be directly connected to the input voltage, Vin (see Figure 11).
Submit Documentation Feedback
13
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
5V
2
VI
Dn
8
5
Track
Sense
VO
PTH05020W
Inhibit
3
Adjust
GND
1
3.3 V
6
7
4
CI
RSET
1,000 mF
698 W
0.1 W, 1%
+
10 9
Up
+
GND
CO
330 mF
GND
Figure 11. Power-Up Application Circuit
When the Track pin is connected to the input voltage the Auto-Track function is permanently disengaged. This
allows the module to power up entirely under the control of its internal soft-start circuitry. When power up is
under soft-start control, the output voltage rises to the set-point at a quicker and more linear rate.
From the moment a valid input voltage is applied, the soft-start control introduces a short time delay (typically
5 ms–10 ms) before allowing the output voltage to rise.
VI (1 V/Div)
VO (1 V/Div)
II (5 A/Div)
t - Time = 5 msec/Div
Figure 12. Power-Up Waveforms
The output then progressively rises to the module’s setpoint voltage. Figure 12 shows the soft-start power-up
characteristic of the 22-A output product (PTH05020W), operating from a 5-V input bus and configured for a
3.3-V output. The waveforms were measured with a 5-A resistive load and the Auto-Track feature disabled. The
initial rise in input current when the input voltage first starts to rise is the charge current drawn by the input
capacitors. Power-up is complete within 15 ms.
OVERCURRENT PROTECTION
For protection against load faults, all modules incorporate output overcurrent protection. Applying a load that
exceeds the regulator’s overcurrent threshold causes the regulated output to shut down. Following shutdown, a
module periodically attempts to recover by initiating a soft-start powerup. This is described as a hiccup mode of
operation, whereby the module continues in a cycle of successive shutdown and power up until the load fault is
removed. During this period, the average current flowing into the fault is significantly reduced. Once the fault is
removed, the module automatically recovers and returns to normal operation.
14
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
OVERTEMPERATURE PROTECTION (OTP)
Products with a high output current capability (>20 A), incorporate overtemperature protection. This feature is
provided by an on-board temperature sensor that protects the module’s internal circuitry against excessively high
temperatures. A rise in the internal temperature may be the result of a drop in airflow, or a high ambient
temperature. If the internal temperature exceeds the OTP threshold, the module’s Inhibit control is automatically
pulled low. This turns the output off. The output voltage drops as the external output capacitors are discharged
by the load circuit. The recovery is automatic, and begins with a soft-start power up. It occurs when the the
sensed temperature decreases by about 10°C below the trip point.
Note: The overtemperature protection is a last resort mechanism to prevent thermal stress to the regulator.
Operation at or close to the thermal shutdown temperature is not recommended, and reduces the long-term
reliability of the module. Always operate the regulator within the specified safe operating area (SOA) limits for
the worst-case conditions of ambient temperature and airflow.
OUTPUT ON/OFF INHIBIT
For applications requiring output voltage on/off control, each series of the PTH family incorporates an output
Inhibit control pin. The inhibit feature can be used wherever there is a requirement for the output voltage from the
regulator to be turned off.
The power modules function normally when the Inhibit pin is left open-circuit, providing a regulated output
whenever a valid source voltage is connected to Vin with respect to GND.
Figure 13 shows the typical application of the inhibit function. Note the discrete transistor (Q1). The Inhibit control
has its own internal pull-up to VI potential. The input is not compatible with TTL logic devices. An open-collector
(or open-drain) discrete transistor is recommended for control.
VOSense
VI
2
1 = Inhibit
+
1,000 mF
5
8
6
PTH05020W
3
CI
9
1
7
4
RSET
Q1
BSS138
CO
VO
L
O
A
D
+
10
330 mF
GND
GND
Figure 13. Inhibit Control Circuit
Turning Q1 on applies a low voltage to the Inhibit control and disables the output of the module. If Q1 is then
turned off, the module executes a soft-start powerup. A regulated output voltage is produced within 20 ms.
Figure 14 shows the typical rise in both the output voltage and input current, following the turn-off of Q1. The turn
off of Q1 corresponds to the rise in the waveform, Q1 Vds. The waveforms were measured with a 5-A constant
current load.
Submit Documentation Feedback
15
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
VO (2 V/Div)
II (2 A/Div)
Q1Vds (5 V/Div)
t - Time = 10 msec/Div
Figure 14. Power-Up from Inhibit Control
REMOTE SENSE
The remote sense feature allows the regulator to compensate for limited amounts of voltage drop, that may be
incurred between the converter and load, due to resistance in the PCB traces. Connecting the +Sense and
–Sense pins to the respective VO and GND output nodes improves the load regulation of the regulator output at
those connection points. This is recommended even if the load circuit is located close to the module.
If either the +Sense and –Sense are left open-circuit, an internal low-value resistor (15-Ω or less), connected
from the respective sense pin to either VO or GND, ensures the output voltage remains in regulation.
With the sense pins connected, the difference between the voltage measured across the VO and GND pins of the
regulator, and that measured at +Sense with respect to +Sense, is the amount of IR drop being compensated by
the regulator. This should be limited to a maximum of 0.3 V.
Note: The remote sense feature is not designed to compensate for the forward drop of nonlinear or
frequency dependent components that may be placed in series with the converter output. Examples include
OR-ing diodes, filter inductors, ferrite beads, and fuses. When these components are enclosed by the remote
sense connection they are effectively placed inside the regulation control loop, which can adversely affect the
stability of the regulator.
Auto-Track™ FUNCTION
The Auto-Track function is unique to the PTH/PTV family, and is available with the all POLA-compatible
products. Auto-Track was designed to simplify the amount of circuitry required to make the output voltage from
each module power up and power down in sequence. The sequencing of two or more supply voltages during
power up is a common requirement for complex mixed-signal applications, that use dual-voltage VLSI ICs such
as the TMS320™ DSP family, micro-processors, and ASICs.
HOW Auto-Track™ WORKS
Auto-Track works by forcing the module’s output voltage to follow a voltage presented at the Track control pin.
This control range is limited to between 0 V and the module’s set-point voltage. Once the Track input is raised
above the set-point voltage, the module’s output remains at its set-point 1. As an example, if the Track pin of a
2.5-V regulator is at 1 V, the regulated output will be 1 V. But, if the voltage at the Track pin rises to 3 V, the
regulated output does not go higher than 2.5 V.
When the Track input is used to connect a number of modules together, it forces the output voltage from each
module to follow a common signal during power-up and power-down. The control signal can be an externally
generated master ramp waveform, or the output voltage from another power supply circuit.(3) For convenience,
each module’s Track input incorporates an internal RC charge circuit. This operates off the module’s input
voltage to provide a suitable rising voltage ramp waveform.
TYPICAL APPLICATION
Connecting the Track inputs of two or more modules forces their Track input to follow the same collective RC
ramp waveform, and allows their power-up sequence to be coordinated from a common Track control signal.
This can be an open-collector (or open drain) device, such as a power-up reset voltage supervisor IC.
16
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
To coordinate a power-up sequence the Track control must first pulled to ground potential. This should be done
at or before input power is applied to the modules. The ground signal should be maintained for at least 10 ms
after input power has been applied. This brief period gives the modules time to complete their internal soft-start
initialization, enabling them to produce an output voltage. A low-cost supply voltage supervisor IC, that includes
built-in time delay, is an ideal component for automatically controlling the Track inputs at power up.
Figure 15 shows how the TPS3808G50 supply voltage supervisor IC (U3) can be used to coordinate the
sequenced power-up of two 5-V input Auto-Track modules. The output of the TPS3808 supervisor becomes
active above an input voltage of 0.8 V, enabling it to assert a ground signal to the common Track control well
before the input voltage has reached the module’s undervoltage lockout threshold. The ground signal is
maintained until approximately 27 ms after the input voltage has risen above U3’s voltage threshold, which is
4.65 V. The 27-ms time period is controlled by the capacitor C3. The value of 4700 µF provides sufficient time
delay for the modules to complete their internal soft-start initialization. The output voltage of each module
remains at zero until the Track control voltage is allowed to rise. When U3 removes the ground signal, the Track
control voltage automatically rises to the input voltage. This causes the output voltage of each module to rise
simultaneously with the other modules, until each reaches its respective set-point voltage.
Figure 15 shows the output voltage waveforms from the circuit of Figure 16 after input voltage is applied to the
circuit. The waveforms, VO1 and VO2, represent the output voltages from the two power modules, U1 (3.3 V) and
U2 (1.8 V), respectively. VTRK, VO1, and VO2 are shown rising together to produce the desired simultaneous
power-up characteristic.
The same circuit also provides a power-down sequence. When the input voltage falls below U3's voltage
threshold, the ground signal is re-applied to the common Track control. This pulls the Track inputs to zero volts,
forcing the output of each module to follow, as shown in Figure 17. In order for a simultaneous power-down to
occur, the Track inputs must be pulled low before the input voltage has fallen below the modules' undervoltage
lockout. This is an important constraint. Once the modules recognize that a valid input voltage is no longer
present, their outputs can no longer follow the voltage applied at their Track input. During a power-down
sequence, the fall in the output voltage from the modules is limited by the maximum output capacitance and the
Auto-Track slew rate.
Submit Documentation Feedback
17
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
NOTES ON USE OF Auto-Track™
1. The Track pin voltage must be allowed to rise above the module’s set-point voltage before the module can
regulate at its adjusted set-point voltage.
2. The Auto-Track function tracks almost any voltage ramp during power up, and is compatible with ramp
speeds of up to 1 V/ms.
3. The absloute maximum voltage that may be applied to the Track pin is VI.
4. The module does not follow a voltage at its Track input until it has completed its soft-start initialization. This
takes at least 10 ms from the time that the module has sensed that a valid voltage is present. During this
period, the Track input should be held at ground potential.
5. The module is capable of both sinking and sourcing current when following a voltage at its Track input.
Therefore startup into an output prebias is not supported when the module is under Auto-Track control.
Prebias holdoff is not necessary when all supply voltages simultaneously under the control of Auto-Track.
6. The Auto-Track function can be disabled by connecting the Track pin to the input voltage (VI). With
Auto-Track disabled, the output voltage rises at a quicker and more linear rate after input power is applied.
14
U1
13
Track
TT
+Sense
+5 V
2, 6
VI
VO
PTH05T210W
10
5, 9
VO1 = 3.3 V
1
−Sense
INH/UVLO
11
VOAdj
GND GND
3, 4
7, 8
+
12
CO1
+
CI1
RSET1
1.62 kΩ
U3
6
VCC
5
3
MR SENSE
C4
0.1 µF
RESET
4 TPS3808G50
CT
GND
C3
4700 pF
1
RTRK#
50 Ω
U2
2
19
20
18
Margin Margin Track
Up Down
+Sense
VI
2
4
6
8
RTRK# = 100 Ω/N
N = Number of track pins connected together
11
9
VI
VO
PTH04040W
−Sense
UVLO Prog
Inhibit
7
GND
1
3
GND
5
12
15
14
VOAdj
10 13 16
17
+
CI2
RSET2
5.49 kΩ
Figure 15. Sequenced Power Up and Power Down using Auto-Track
18
Submit Documentation Feedback
VO2 = 1.8 V
+
CO2
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
VTRK (1 V/div)
VTRK (1 V/div)
V01 (1 V/div)
V01 (1 V/div)
V02 (1 V/div)
V02 (1 V/div)
t − Time − 200 µs/div
t − Time − 20 ms/div
Figure 16. Auto-Track Simultaneous Power Up
Waveforms
Figure 17. Auto-Track Simultaneous Power Down
Waveforms
MARGIN UP/DOWN CONTROLS
The PTHxx060, PTHxx010, PTHxx020, and PTHxx030 products incorporate Margin Up and Margin Down control
inputs. These controls allow the output voltage to be momentarily adjusted(1), either up or down, by a nominal
5%. This provides a convenient method for dynamically testing the operation of the load circuit over its supply
margin or range. It can also be used to verify the function of supply voltage supervisors. The ±5% change is
applied to the adjusted output voltage, as set by the external resistor, Rset at the Vo Adjust pin.
The 5% adjustment is made by pulling the appropriate margin control input directly to the GND terminal 2. A
low-leakage open-drain device, such as an n-channel MOSFET or p-channel JFET is recommended for this
purpose(3). Adjustments of less than 5% can also be accommodated by adding series resistors to the control
inputs. The value of the resistor can be selected from Table 4, or calculated using the following formula.
UP/DOWN ADJUST RESISTANCE CALCULATION
RU or RD =
499
- 99.8 kW
D%
(4)
Where ∆% = The desired amount of margin adjusted in percent.
NOTES
1. The Margin Up and Margin Down controls were not intended to be activated simultaneously. If they are
activated simultaneously, the effects on the output voltage may not completely cancel, resulting in the
possibility of a higher error in the output voltage set point.
2. The ground reference should be a direct connection to the module GND at pin 7 (pin 1 for the PTHxx050).
This produces a more accurate adjustment at the load circuit terminals. The transistors Q1 and Q2 should be
located close to the regulator.
3. The Margin Up and Margin Down control inputs are not compatible with devices that source voltage. This
includes TTL logic. These are analog inputs and should only be controlled with a true open-drain device
(preferably discrete MOSFET transistor). The device selected should have low off-state leakage current.
Each input sources 8 µA when grounded, and has an open-circuit voltage of 0.8 V.
Submit Documentation Feedback
19
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
Table 4. Margin Up/Down Resistor Values
% ADJUST
RU / RD
5
0 kΩ
4
24.9 kΩ
3
66.5 kΩ
2
150.0 kΩ
1
397.0 kΩ
1
10
9
8
7
0V
PTH05010W
(Top View)
VI
2
+
RD
RU
+VO
6
3
CI
+VO
4
5
RSET
0.1 W, 1%
+
CO
L
O
A
D
Q1
Margin Down
Q2
Margin Up
GND
GND
Figure 18. Margin Up/Down Application Schematic
PREBIAS STARTUP CAPABILITY
A prebias startup condition occurs as a result of an external voltage being present at the output of a power
module prior to its output becoming active. This often occurs in complex digital systems when current from
another power source is backfed through a dual-supply logic component, such as an FPGA or ASIC. Another
path might be via clamp diodes as part of a dual-supply power-up sequencing arrangement. A prebias can cause
problems with power modules that incorporate synchronous rectifiers. This is because under most operating
conditions, these types of modules can sink as well as source output current.
The PTH/PTV family of power modules incorporate synchronous rectifiers, but does not sink current during
startup(1), or whenever the Inhibit pin is held low. However, to ensure satisfactory operation of this function,
certain conditions must be maintained(2). Figure 20 shows an application demonstrating the prebias startup
capability. The start-up waveforms are shown in Figure 19. Note that the output current from the PTH03010W (Io)
shows negligible current until its output voltage rises above that backfed through diodes D1 and D2.
Note: The prebias start-up feature is not compatible with Auto-Track. When the module is under Auto-Track
control, it sinks current if the output voltage is below that of a back-feeding source. To ensure a prebias
hold-off, one of two approaches must be followed when input power is applied to the module. The Auto-Track
function must be disabled(3), or the module’s output held off (for at least 50 ms) using the Inhibit pin. Either
approach ensures that the Track pin voltage is above the set-point voltage at start up.
NOTES
1. Startup includes the short delay (approximately 10 ms) prior to the output voltage rising, followed by the rise
of the output voltage under the module’s internal soft-start control. Startup is complete when the output
voltage has risen to either the set-point voltage or the voltage at the Track pin, whichever is lowest.
2. To ensure that the regulator does not sink current when power is first applied (even with a ground signal
applied to the Inhibit control pin), the input voltage must always be greater than the output voltage throughout
the powerup and power-down sequence.
3. The Auto-Track function can be disabled at power up by immediately applying a voltage to the module’s
Track pin that is greater than its set-point voltage. This can be easily accomplished by connecting the Track
20
Submit Documentation Feedback
PTH04040W
www.ti.com
SLTS238A – SEPTEMBER 2005 – REVISED FEBRUARY 2006
pin to Vin.
VI (1 V/Div)
VO (1 V/Div)
IO (5 A/Div)
t - Time = 5 msec/Div
Figure 19. Pre-Bias Startup Waveforms
VI = 3.3 V
10
9
8
5
Track
2
VI
PTH03010W
Inhibit
3
+C
I
330 mF
Sense
VO = 2.5 V
6
+
VAdj
GND
1
VO
7
Io
4
R2
2k21
VCORE
+C
VCCIO
O
330 mF
ASIC
Figure 20. Application Circuit Demonstrating Prebias Startup
Submit Documentation Feedback
21
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Mailing Address:
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2006, Texas Instruments Incorporated