ETC VSUU-120-D285

•
VSUU-120-D285 Open Frame Switching Power Supply
Features
·Universal Input Voltage 90-264 VAC, 47-63 Hz
·Internal EMI filter
·Input connector mates with Molex housing 09-50-3051 and Molex
2878 series crimp terminal
·Output connector mates with Molex housing 09-50-3061 (or 09-503081, or 09-50-3131) and Molex 2878 series crimp terminal
·Input Surge current, over voltage and over load protection
·Power factor correction
·Power fail detect (optional)
·Class I Insulation
·Size : 3”X5”X1.54”
·Two Years Warranty
Model
Number
VSUU-120-D285
Output
Voltage
+28VDC
+5VDC
Output
Current
0.39-3.92A
0.2-2A
Total
Regulation
5%
5%
Max
Output Power
120W
120W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Power Factor Correction
Output Power Range
Input Current (low line)
Input Current (high line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start up time
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
Test Conditions
Io=Full load, Vin=90~260VAC
Vin=90 to 264 VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, cool start, Vin=115VAC
Io=Full load, 25°C, cool start, Vin=230VAC
Io=Full load, Vin=230VAC
Io=Full load
Vin=230VAC
Min.
90
47
0.95
0
70
Typ.
0.97
12
26
80
0.5
3
112
110
Io=Full load to Half load, Vin=100VAC
Io=Full load, Vin=110VAC
Io=Full load, Vin=100VAC
Full load, Vin=90VAC
I0=Full load, Vin=240VAC
All output
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
16
0.3
18
1
1
0.4
-0.04
www.v-infinity.com
Max.
264
63
1.0
120
1.7
1.0
15
30
88
1
5
132
150
4
20
2
2
0.45
0.04
Unit
VAC
Hz
W
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°C
1-866-372-1258
•
VSUU-120-D285 Open Frame Switching Power Supply
Environmental
Parameter
Test Conditions
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 50°C to 50% load at 70°C
Min.
0
-40
5
Typ.
Max.
70
85
95
Unit
°C
°C
%
Test Conditions
Primary to secondary
Min.
4242
Typ.
Max.
Unit
VDC
Primary to ground
2121
VDC
50
B
B
M ohms
Class
Class
Safety Specifications
Parameter
Dielectric withstanding voltage
for primary to secondary
Dielectric withstanding voltage
for primary to ground
Isolation resistance
EMI requirements for CISPR-22
EMI requirements for FCC part-15
Test voltage=500VDC
Vin=220VAC
Vin=110 VAC
Mechanical Specifications
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify
the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using VInfinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered
outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258