SN54ALS165, SN74ALS165 PARALLEL-LOAD 8-BIT REGISTERS SDAS157B – JUNE 1982 – REVISED DECEMBER 1994 • • • • • SN54ALS165 . . . J PACKAGE SN74ALS165 . . . D OR N PACKAGE (TOP VIEW) Complementary Outputs Direct Overriding Load (Data) Inputs Gated Clock Inputs Parallel-to-Serial Data Conversion Package Options Include Plastic Small-Outline (D) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs SH/LD CLK E F G H QH GND description The ′ALS165 are parallel-load 8-bit serial shift registers that, when clocked, shift the data toward serial (QH and QH) outputs. Parallel-in access to each stage is provided by eight individual direct data (A– H) inputs that are enabled by a low level at the shift/load (SH/LD) input. The ′ALS165 have a clock-inhibit function and complemented serial outputs. 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 VCC CLK INH D C B A SER QH CLK SH/LD NC VCC CLK INH SN54ALS165 . . . FK PACKAGE (TOP VIEW) E F NC G H 4 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 D C NC B A QH GND NC QH SER Clocking is accomplished by a low-to-high transition of the clock (CLK) input while SH/LD is held high and the clock inhibit (CLK INH) input is held low. The functions of CLK and CLK INH are interchangeable. Since a low CLK and a low-to-high transition of CLK INH also accomplishes clocking, CLK INH should be changed to the high level only while CLK is high. Parallel loading is inhibited when SH/LD is held high. The parallel inputs to the register are enabled while SH/LD is low independently of the levels of the CLK, CLK INH, or serial (SER) inputs. NC – No internal connection The SN54ALS165 is characterized for operation over the full military temperature range of – 55°C to 125°C. The SN74ALS165 is characterized for operation from 0°C to 70°C. FUNCTION TABLE INPUTS FUNCTION SH/LD CLK CLK INH L X X Parallel load H H X No change H X H L ↑ No change Shift† H ↑ L Shift† † Shift = content of each internal register shifts toward serial outputs. Data at SER is shifted into first register. H Copyright 1994, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 SN54ALS165, SN74ALS165 PARALLEL-LOAD 8-BIT REGISTERS SDAS157B – JUNE 1982 – REVISED DECEMBER 1994 logic symbol† SRG8 C1 [LOAD] 1 SH/LD CLK INH CLK SER A B C D E F G H 15 ≥1 2 C2/ 10 2D 11 1D 12 1D 13 14 3 4 5 6 9 1D QH 7 QH † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, J, and N packages. logic diagram (positive logic) A SH/LD CLK INH CLK SER 1 B 11 C 12 D 13 E 14 F 3 4 H 5 6 15 2 10 S C1 1D R S C1 1D R S C1 1D R S C1 1D R S C1 1D R Pin numbers shown are for the D, J, and N packages. 2 G POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 S C1 1D R S C1 1D R S C1 1D R 9 7 QH QH SN54ALS165, SN74ALS165 PARALLEL-LOAD 8-BIT REGISTERS SDAS157B – JUNE 1982 – REVISED DECEMBER 1994 typical shift, load, and inhibit sequences CLK CLK INH SER L SH/LD Data Inputs A H B L C H D L E H F L G H H H QH H H L H L H L H QH L L H L H L H L Inhibit Serial Shift Load absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Operating free-air temperature range, TA: SN54ALS165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C SN74ALS165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 SN54ALS165, SN74ALS165 PARALLEL-LOAD 8-BIT REGISTERS SDAS157B – JUNE 1982 – REVISED DECEMBER 1994 recommended operating conditions SN54ALS165 SN74ALS165 MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 UNIT VCC VIH Supply voltage VIL IOH Low-level input voltage 0.7 0.8 High-level output current – 0.4 – 0.4 mA IOL fclock Low-level output current 4 8 mA 45 MHz High-level input voltage 2 Clock frequency 2 0 35 V 0 CLK high 14 11 CLK low 14 11 CLK low V V tw(CLK) (CLK) Pulse duration duration, CLK (see Figure 1) tw(load) tsu1 Pulse duration, SH/LD low 15 12 ns Setup time, clock enable (see Figure 1) 15 11 ns tsu2 tsu3 Setup time, parallel input (see Figure 1) 11 10 ns Setup time, serial input (see Figure 2) 11 10 ns tsu4 th Setup time, shift (see Figure 2) 15 10 ns TA Operating free-air temperature Hold time at any input 4 ns 4 – 55 125 ns 0 70 °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VIK VOH VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = – 18 mA IOH = – 0.4 mA VOL VCC = 4 4.5 5V IOL = 4 mA IOL = 8 mA II IIH VCC = 5.5 V, VCC = 5.5 V, VI = 7 V VI = 2.7 V IIL IO‡ VCC = 5.5 V, VCC = 5.5 V, VI = 0.4 V VO = 2.25 V SN54ALS165 TYP† MAX MIN SN74ALS165 TYP† MAX MIN – 1.5 VCC – 2 – 1.5 VCC – 2 0.25 0.4 0.1 – 20 UNIT V V 0.25 0.4 0.35 0.5 0.1 V mA 20 20 µA – 0.1 – 0.1 mA – 112 mA – 112 – 30 ICC VCC = 5.5 V, See Note 1 12 24 12 24 mA † All typical values are at VCC = 5 V, TA = 25°C. ‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS. NOTE 1: With the outputs open, CLK INH and CLK at 4.5 V, and a clock pulse applied to SH/LD, ICC is measured first with the parallel inputs at 4.5 V, then with the parallel inputs grounded. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN54ALS165, SN74ALS165 PARALLEL-LOAD 8-BIT REGISTERS SDAS157B – JUNE 1982 – REVISED DECEMBER 1994 switching characteristics (see Figures 1, 2, and 3) FROM (INPUT) PARAMETER VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 Ω, TA = MIN to MAX† SN54ALS165 SN74ALS165 TO (OUTPUT) MIN fmax tPLH MAX 35 tPHL tPLH SH/LD Any CLK Any H QH tPHL tPLH tPHL tPLH MIN MAX 45 MHz 4 23 4 20 4 23 4 22 3 14 3 13 3 15 3 14 3 14 3 13 3 18 3 16 2 15 3 16 2 17 QH H tPHL 3 17 † For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. UNIT ns ns ns ns PARAMETER MEASUREMENT INFORMATION 3.5 V (disable while clock is high) Vref CLK INH 0.3 V tsu1 3.5 V CLK Vref Vref Vref 0.3 V F and H Inputs (see Notes A and B) tw(CLK) tsu2 3.5 V Vref Vref Vref Vref 0.3 V tsu2 tw(load) tw(load) 3.5 V SH/LD Vref tPHL Vref tPLH tPHL Output QH Vref Vref tPLH Output QH tPHL tPLH NOTES: A. B. C. D. tw(CLK) Vref Vref Vref Vref Vref tPLH Vref tPHL Vref tPHL Vref tPLH Vref 0.3 V tPLH VOH Vref VOL tPHL VOH Vref VOL The remaining six data inputs and SER are low. Prior to test, high-level data is loaded into the H input. The input pulse generators have the following characteristics: PRR ≤ 1 MHz, duty cycle ≤ 50%, tr = tf = 2 ns. Vref = 1.3 V Figure 1. Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 SN54ALS165, SN74ALS165 PARALLEL-LOAD 8-BIT REGISTERS SDAS157B – JUNE 1982 – REVISED DECEMBER 1994 PARAMETER MEASUREMENT INFORMATION 3.5 V SH/LD Vref 0.3 V tsu4 3.5 V SER Vref 0.3 V tsu3 tsu3 3.5 V CLK Vref Vref 0.3 V tn NOTES: A. The eight data inputs and CLK INH are low. Results are monitored at QH at tn + 7. B. The input pulse generators have the following characteristics: PRR ≤ 1 MHz, duty cycle = 50%, tr = tf = 2 ns. C. Vref = 1.3 V Figure 2. Voltage Waveforms From Output Under Test CL (see Note A) Test Point RL NOTE A: CL includes probe and jig capacitance. Figure 3. Load Circuit for Switching Tests 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PACKAGE OPTION ADDENDUM www.ti.com 30-Mar-2005 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty Lead/Ball Finish MSL Peak Temp (3) SN74ALS165D ACTIVE SOIC D 16 40 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1 YEAR/ Level-1-235C-UNLIM SN74ALS165DR ACTIVE SOIC D 16 2500 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1 YEAR/ Level-1-235C-UNLIM SN74ALS165N ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU Level-NC-NC-NC SN74ALS165N3 OBSOLETE PDIP N SNJ54ALS165J OBSOLETE CDIP J 16 TBD Call TI Call TI 16 TBD Call TI Call TI SNJ54ALS165W OBSOLETE CFP W 16 TBD Call TI Call TI (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2005, Texas Instruments Incorporated