SONY ILX524

ILX524KA
2700 pixel × 3 line CCD Linear Sensor (Color)
Description
The ILX524KA is a reduction type CCD linear
sensor developed for color image scanner. This
sensor reads legal-size documents at a density of
300 DPI.
11
2700
2700
2700
8
S2700
S2700
S2700
16
A
A
A
A
A
A
AA
AA
4
20
φ1
Driver
15
φ2
VDD
φLH
VDD
VOUT-R 1
VOUT-G 22
VOUT-B 21
B
G
D14
D15
R
D63
S1
13 φROG-B
φROG-R 10
GND 11
5
14 NC
GND
9
3
NC
φRS
15 φ2
2
8
GND
φ1
Driver
16 VDD
Read Out Gate
7
CCD Register
NC
Red
17 NC
Read Out Gate
6
CCD Register
NC
Green
18 NC
Read Out Gate
5
CCD Register
GND
Blue
19 NC
1
4
1
φLH
1
20 VDD
D14
D15
3
D15
φRS
D14
21 VOUT-B
D63
S1
22 VOUT-G
D63
S1
2
D64
GND
D64
1
D64
VOUT-R
D75
Pin Configuration (Top View)
D75
V
°C
°C
D75
Absolute Maximum Ratings
• Supply voltage
VDD
15
• Operating temperature
–10 to +55
• Storage temperature
–30 to +80
GND
φROG-R
φROG-G
12
Driver
10
φROG-B
13
Block Diagram
Driver
Features
• Number of effective pixels:
8100 pixels (2700 pixels × 3)
• Pixel size:
8µm × 8µm (8µm pitch)
• Distance between line: 64µm (8 Lines)
• Single-sided readout
• Ultra low lag / High sensitivity
• Single 12V power supply
• Input clock pulse:
CMOS 5V drive
• Number of output
3 (R, G, B)
• Package:
22 pin Plastic-DIP (400 mil)
22 pin DIP (Plastic)
12 φROG-G
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
–1–
E99619-PS
ILX524KA
Pin Description
Pin No.
Symbol
Description
Pin No.
Symbol
Description
1
VOUT-R
Signal out (red)
12
φROG-G
Clock pulse input
2
GND
GND
13
φROG-B
Clock pulse input
3
φRS
Clock pulse input
14
NC
NC
4
φLH
Clock pulse input
15
φ2
Clock pulse input
5
GND
GND
16
VDD
12V power supply
6
NC
NC
17
NC
NC
7
NC
NC
18
NC
NC
8
φ1
Clock pulse input
19
NC
NC
9
NC
NC
20
VDD
12V power supply
10
φROG-R
Clock pulse input
21
VOUT-B
Signal out (blue)
11
GND
GND
22
VOUT-G
Signal out (green)
Recommended Supply Voltage
Item
Min.
Typ.
Max.
Unit
VDD
11.4
12.0
12.6
V
Clock Characteristics
Item
Symbol
Min.
Typ.
Max.
Unit
Input capacity of φ1, φ2
Cφ1, Cφ2
—
400
—
pF
Input capacity of φLH
CφLH
—
10
—
pF
Input capacity of φRS
CφRS
—
10
—
pF
Input capacity of φROG∗
CφROG
—
10
—
pF
∗ It indicates that φROG-R, φROG-G, φROG-B as φROG.
Clock Frequency
Item
Symbol
φ1, φ2, φLH, φRS
fφ1, fφ2, fφLH, fφRS
Min.
Typ.
Max.
Unit
—
1
5
MHz
Input Clock Pulse Voltage Condition
Item
φ1, φ2, φLH, φRS,
φROG pulse voltage
Min.
Typ.
Max.
Unit
High level
4.75
5.0
5.25
V
Low level
—
0
0.1
V
–2–
ILX524KA
Electrooptical Characteristics (Note 1)
Ta = 25°C, VDD = 12V, fφRS = 1MHz, Input clock = 5Vp-p, Light source = 3200K, IR cut filter CM-500S (t = 1.0mm)
Item
Symbol
Min.
Typ.
Max.
Unit
Remarks
V/(lx · s)
Note 2
Red
RR
1.3
2.0
2.7
Green
RG
2.1
3.2
4.3
Blue
RB
1.6
2.5
3.4
Sensitivity nonuniformity
PRNU
—
4
20
%
Note 3
Saturation output voltage
VSAT
2
3.2
—
V
Note 4
Red
SER
0.74
1.6
—
Green
SEG
0.46
1
—
lx · s
Note 5
Blue
SEB
0.58
1.28
—
Dark voltage average
VDRK
—
0.3
2
mV
Note 6
Dark signal nonuniformity
DSNU
—
1.5
5
mV
Note 6
Image lag
IL
—
0.02
—
%
Note 7
Supply current
IVDD
—
26
50
mA
—
Total transfer efficiency
TTE
92
98
—
%
—
Output impedance
ZO
—
250
—
Ω
—
Offset level
VOS
—
6.5
—
V
Note 8
Dynamic range
DR
1000
10670
—
—
Note 9
Sensitivity
Saturation
exposure
Note
1) In accordance with the given electrooptical characteristics, the black level is defined as the average value
of D2, D3 to D12.
2) For the sensitivity test light is applied with a uniform intensity of illumination.
3) PRNU is defined as indicated below. Ray incidence conditions are the same as for Note 2.
VOUT-G = 500mV (Typ.)
PRNU =
(VMAX – VMIN) /2
VAVE
× 100 [%]
Where the 2700 pixels are divided into blocks of 100. The maximum output of each block is set to VMAX,
the minimum output to VMIN and the average output to VAVE.
4) Use below the minimum value of the saturation output voltage.
5) Saturation exposure is defined as follows.
SE =
VSAT
R
Where R indicates RR, RG, RB, and SE indicates SER, SEG, SEB.
6) Optical signal accumulated time τint stands at 10ms.
7) VOUT-G = 500mV (Typ.)
VOUT
8) Vos is defined as indicated bellow.
VOUT indicates VOUT-R, VOUT-G, and VOUT-B.
9) Dynamic range is defined as follows.
DR =
VSAT
VDRK
AAA
AA
AAAAA
AAAAA
VOS
GND
When the optical signal accumulated time is shorter, the dynamic range gets wider because the optical
signal accumulated time is in proportion to the dark voltage.
–3–
–4–
VOUT
φRS
φ2
φ1
φLH
φROG
D3
D2
3
D1
2
1
VOUT indicates VOUT-R, VOUT-G, VOUT-B.
AAAAAAAAAAA
D62
D15
D14
D13
4
Dummy signal (63 pixels)
S2699
S2698
S2
S1
D63
1-line output period (2775 pixels)
Optical black (49 pixels)
D61
Note) The transfer pulses (φ1, φ2, φLH) must have more than 2775 cycles.
0
5
0
5
0
5
0
5
Clock Timing Chart 1
ILX524KA
D75
2775
D71
D70
D65
D64
S2700
ILX524KA
Clock Timing Chart 2
t4
t5
φROG
t2
t6
t7
φ1
t1
t3
φ2
Clock Timing Chart 3
t7
t6
φ1
φLH
φ2
t10
t11
t9
φRS
t8
t13
VOUT
AAAAAAAAA
AAAAAAAAA
t12
–5–
AAA
AAA
ILX524KA
Clock Pulse Recommended Timing
Symbol
Item
φROG, φ1 pulse timing
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
φROG pulse high level period
φROG, φ1 pulse timing
φROG pulse rise time
φROG pulse fall time
φ1 pulse rise time /φ2 pulse fall time
φ1 pulse fall time /φ2 pulse rise time
φRS pulse high level period
φRS, φLH pulse timing
φRS pulse rise time
φRS pulse fall time
Signal output delay time
∗ These timing is the recommended condition under fφRS = 1MHz.
–6–
Min.
Typ.
Max.
Unit
50
100
—
ns
800
1000
—
ns
800
1000
—
ns
0
5
10
ns
0
5
10
ns
0
20
60
ns
0
20
60
ns
—
ns
—
ns
45
250∗
250∗
0
10
30
ns
0
10
30
ns
—
10
—
ns
—
10
—
ns
45
47µF/16V
Tr1
∗ Data rate fφRS = 1MHz.
0.1µF
12V
VOUT-G
Tr1
2
1
100Ω
φRS
3
100Ω
7
6
2Ω
φ1
8
9
φROG-R
10
IC1
11
IC1
IC1: 74AC04
Tr1 : 2SC2785
Application circuits shown are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for
any problems arising out of the use of these circuits or for any infringement of third party patent and other right due to same.
φLH
4
5
12
13
14
15
16
17
18
19
φROG-G
20
2Ω
φROG-B
21
Tr1
VOUT-B
φ2
22
100Ω
5.1kΩ
VOUT-G
5.1kΩ
100Ω
100Ω
VOUT-R
5.1kΩ
VOUT-B
VOUT-R
VDD
GND
NC
φRS
NC
φLH
NC
GND
VDD
NC
–7–
NC
φ2
φ1
NC
NC
φROG-B
φROG-R
φROG-G
GND
Application Circuit∗
ILX524KA
ILX524KA
Example of Representative Characteristics (VDD = 12V, Ta = 25°C)
Spectral sensitivity characteristics (Standard characteristics)
1
Relative sensitivity
0.8
0.6
0.4
0.2
0
400
450
500
550
600
650
700
Wavelength [nm]
Dark signal output temperature characteristics
(Standard characteristics)
Integration time output voltage characteristics
(Standard characteristics)
10
Output voltage rate
Output voltage rate
5
1
0.5
0.1
1
0.5
0.1
0
10
20
30
40
50
60
1
5
10
Ta – Ambient temperature [°C]
τ int – Integration time [ms]
Offset level vs. VDD characteristics
(Standard characteristics)
Offset level vs. temperature characteristics
(Standard characteristics)
12
12
Ta = 25°C
10
VOS – Offset level [V]
VOS – Offset level [V]
10
8
6
∆VOS
∆VDD
4
0.3
2
0
11.4
8
6
∆VOS
∆Ta
4
–0.5mV/°C
2
0
12
0
12.6
VDD [V]
10
20
30
40
50
Ta – Ambient temperature [°C]
–8–
60
ILX524KA
Notes of Handling
1) Static charge prevention
CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following
protective measures.
a) Either handle bare handed or use non chargeable gloves, clothes or material.
Also use conductive shoes.
b) When handling directly use an earth band.
c) Install a conductive mat on the floor or working table to prevent the generation of static electricity.
d) Ionized air is recommended for discharge when handling CCD image sensor.
e) For the shipment of mounted substrates, use boxes treated for prevention of static charges.
2) Notes on Handling CCD Packages
The following points should be observed when handling and installing plastic packages.
a) Remain within the following limits when applying static load to the package.
,
,
,
,
(1) Compressive strength: 39N/surface (Do not apply load more than 0.7mm inside the outer perimeter
of the glass portion.)
(2) Shearing strength: 29N/surface
(3) Tensile strength: 29N/surface
(4) Torsional strength: 0.9Nm
Cover glass
Plastic portion
Ceramic portion
39N
(1)
Adhesive
29N
29N
0.9Nm
(2)
(3)
(4)
b) In addition, if a load is applied to the entire surface by a hard component, bending stress may be
generated and the package may fracture, etc., depending on the flatness of the ceramic portion.
Therefore, for installation, either use an elastic load, such as a spring plate, or an adhesive.
c) Be aware that any of the following can cause the package to crack or dust to be generated.
(1) Applying repetitive bending stress to the external leads.
(2) Applying heat to the external leads for an extended period of time with soldering iron.
(3) Rapid cooling or heating.
(4) Prying the plastic portion and ceramic portion away at a support point of the adhesive layer.
(5) Applying the metal a crash or a rub against the plastic portion.
Note that the preceding notes should also be observed when removing a component from a board after it
has already been soldered.
d) The notch of the plastic portion is used for directional index, and that can not be used for reference of
fixing. In addition, the cover glass and seal resin may overlap with the notch or ceramic may overlap
with the notch of the plastic portion.
3) Soldering
a) Make sure the package temperature does not exceed 80°C.
b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a grounded 30W
soldering iron and solder each pin in less then 2 seconds. For repairs and remount, cool sufficiently.
c) To dismount an imaging device, do not use a solder suction equipment. When using an electric desoldering
tool, ground the controller. For the control system, use a zero cross type.
–9–
ILX524KA
4) Dust and dirt protection
a) Operate in clean environments.
b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should
dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized
air is recommended.)
c) Clean with a cotton bud and ethyl alcohol if the glass surface is grease stained. Be careful not to scratch
the glass.
d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when
moving to a room with great temperature differences.
5) Exposure to high temperatures or humidity will affect the characteristics. Accordingly avoid storage or
usage in such conditions.
6) CCD image sensors are precise optical equipment that should not be subject to mechanical shocks.
– 10 –
5.0 ± 0.3
– 11 –
1
V
H
22
6.53 ± 0.3
21.6 (8µmX2700Pixels)
32.0 ± 0.3
2.54
Plastic , Ceramic
GOLD PLATING
42 ALLOY
2.21g
LS-D10(E)
PACKAGE MATERIAL
LEAD TREATMENT
LEAD MATERIAL
PACKAGE MASS
DRAWING NUMBER
30.6
No.1 Pixel (Green)
PACKAGE STRUCTURE
4.0 ± 0.5
0.51
11
12
22pin DIP(400mil)
9.0
0.3
2.10
Unit : mm
10.0 ± 0.3
M
2.80 ± 0.5
Package Outline
0˚ to 9˚
0.25
10.16
2. The thickness of the cover glass is 0.7mm, and the refractive index is 1.5.
1. The height from the bottom to the sensor surface is 1.61 ± 0.3mm.
ILX524KA