CHINFA DRA10-24

DRA10 SERIES
AC - DC DIN RAIL MOUNTABLE POWER SUPPLY
INDUSTRIAL CONTROL EQUIPMENT
FEATURES
‧UL / cUL / TUV / CE
‧UNIVERSAL INPUT 90~264VAC
‧SHORT CIRCUIT PROTECTION
‧INTERNAL INPUT FILTER
‧2 YEARS WARRANTY
R
R
R
H H H
Class I, Div 2
UL 1310
a
UL 60950-1
IND. CONT. EQ.
UL 508
EN 60950-1
MODEL LIST
MODEL NO.
INPUT
VOLTAGE
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
Single Output Models
DRA10-05
90~264 VAC
10 WATTS
+ 5 VDC
2000 mA
71%
73%
DRA10-12
90~264 VAC
10 WATTS
+ 12 VDC
840 mA
73%
75%
DRA10-15
90~264 VAC
10 WATTS
+ 15 VDC
670 mA
74%
76%
DRA10-24
90~264 VAC
10 WATTS
+ 24 VDC
420 mA
74%
76%
max.
max.
unit
unit
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
GENERAL
Conditions
Conditions
Characteristics
min.
min.
typ.
typ.
Switching frequency
Vi nom, Io nom
Isolation voltage
Input-Output
3000 / 4242
VAC / VDC
Input-FG
1500 / 2121
VAC / VDC
132
Isolation resistance
Input-Output, @ 500VDC
100
Ambient temperature
Operating at Vi nom
-20
o
KHz
MΩ
o
+ 71
o
2.5
o
C
Derating (see derating curve)
Vi nom, from +61 C to +71 C
Storage temperature
Non operational
-25
+ 85
Relative humidity
Vi nom, Io nom
20
95
% RH
Temperature coefficient
Vi nom, Io min
± 0.03
% / oC
MTBF
o
Bellcore Issue 6 @40 C, GB
Altitude during operation
IEC 60068-2-13
Dimension
Spring terminal type
Cooling
Free air convection
Pollution degree
www.chinfa.com
2011.01.27
%/ C
o
C
5V model
801000
Hours
12V model
803000
Hours
15V model
805000
Hours
24V model
808000
Hours
4850
L90 x W22.5 x D114
m
mm
2
[email protected]
P1
DRA10 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
INPUT SPECIFICATIONS
Characteristics
Rated input voltage
Conditions
Absolute input max. range
Io nom
Ta min ... Ta max,
Io nom
Input current
Vi : 115 / 230 VAC, Io nom
Rated input current
Vi : 90 VAC, Io nom
Line frequency
Vi nom, Io nom
Inrush current
Power dissipation
Vi : 115 / 230 VAC , Io nom
Leakage current
min.
AC in
DC in
typ.
max.
unit
100
240
VAC
90
120
264
375
VAC
VDC
200 / 130
47
Vi : 230 VAC, Io nom
mA
300
mA
63
10 / 18
Hz
A
5V model
4.0
W
12V model
15V model
3.4
W
3.3
W
24V model
2.8
W
Input-Output
0.25
mA
3.5
mA
max.
unit
Input-FG
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
Output voltage accuracy
(Adjusted before shipment)
Vi nom, Io max
0
Minimum load
Line regulation
Vi nom
Io nom, Vi min ...Vi max
0
Load regulation
Vi nom, Io min ...Io nom
Voltage trim range
Vi nom,
0.8 Io nom
Rated continuous loading
+ 20
Rise time
Vi nom, Io nom
Vi nom, Io nom
12V model
15V model
0.84 A @ 12Vdc / 0.72 A @ 13.8 Vdc
24V model
0.42 A @ 24Vdc / 0.34 A @ 28.8 Vdc
25 / 100
0.67 A @ 15Vdc / 0.58 A @ 17.25 Vdc
with 3500μF CAP
Vi nom, Io nom
Ripple & noise
Vi nom, Io nom, BW = 20MHz
Power back immunity
Vi nom, Io nom
1 second
Vi nom, 1~0.5 Io nom
Vi nom, Io nom
1000
ms
ms
1500
ms
150
ms
500
ms
150
ms
2
ms
50
mV
5V model
7.5
VDC
12V model
15V model
18
VDC
22
35
VDC
24V model
Vi nom, Io nom
%
2 A @ 5Vdc / 1.7 A @ 5.75 Vdc
with 3500μF CAP
Fall time
Transient recovery time
DC ON indicator threshold
at start up (Green LED)
%
- 10
Vi nom, Io nom
Vi nom, Io nom
Vi nom, Io nom
%
24V model
5V model
Turn on time
Capacitor load
%
- 10
Vi : 115 / 230 VAC , Io nom
3500
VDC
μF
5V model
3.5
4.5
VDC
12V model
15V model
9.0
10.8
VDC
11.0
13.5
VDC
18
21.6
VDC
3.5
4.5
VDC
9.0
10.8
VDC
11.0
13.5
VDC
24V model
5V model
12V model
15V model
24V model
Efficiency
%
±1
5V...15V models
Vi nom
%
+1
±2
+ 15
Hold up time
DC LOW indicator threshold
after start up (Red LED)
typ.
Vi nom, Io nom, Po / Pi
VDC
18
21.6
Up to 76%, See model list and typ efficiency curve
CONTROL AND PROTECTION
Characteristics
Conditions
min.
Input fuse
Internal surge voltage protection
Rated over load protection
www.chinfa.com
2011.01.27
typ.
unit
max.
T2A / 250VAC internal
IEC 61000-4-5
Vi nom (see typ current limited curve)
Varistor
110
145
%
[email protected]
P2
DRA10 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
CONTROL AND PROTECTION
Characteristics
Over voltage protection
Conditions
Vi nom, Io nom (Auto Recovery)
typ.
min.
unit
max.
145
125
Output short circuit
Hiccup mode
Degree of protection
IP20
%
APPROVALS AND STANDARDS
UL / cUL
UL 508 Listed
UL 60950-1, UL 1310 Class 2 Power Recognized
ISA 12.12.01(Class I, Division 2, Groups A, B, C and D)
TUV
EN 60950-1, CB scheme
CE
EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3
EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3
EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4
EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11
ENV 50204 Level 2, EN 61204-3
CCC
GB4943, GB9254, GB17625.1
Vibration resistance
meet IEC 60068-2-6 (Mounting by rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis )
Shock resistance
meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face)
PHYSICAL CHARACTERISTICS
Case size
90 x 22.5 x 114 mm (3.6 x 0.89 x 4.49 inches)
Case material
Plastic
Weight
120 g
Packing
0.21 kg ; 56
/ 12.5 kg / 2.16 CUFT
MECHANISM & PIN CONFIGURATION
mm [inch]
22.50 [0.89]
2 1
V- V+
90.00 [3.60]
DC Output
LO
ON
Vout ADJ.
114.00 [4.49]
CONSTRUCTION
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safeIy and
firmly on the rail.
INSTALLATION
Ventilation / Cooling
Normal convection
All sides 25mm free space
For cooling recommended
Connector size range
Spring terminal:
AWG24-14 (0.2~2mm2 ) flexible / solid cable,
10 m/m stripping at cable end recommends
Use copper conductors only, 60 / 75oC
GENERAL TOLERANCE
N L
0.00[0.00] - 30.00[1.18]
±0.30[0.01]
30.00[1.18] - 120.00[4.72]
±0.50[0.02]
3 4 5
www.chinfa.com
2011.01.27
[email protected]
P3
DRA10 SERIES
PIN ASSIGNMENT
Designation
OUT
PIN NO.
1
2
Description
V+
Positive output terminal
V -
Negative output terminal
Ground this terminal to minimize high-frequency emissions
IN
3
4
OTHER
5
N
Input terminals (neutral conductor, no polarity at DC input)
L
Input terminals (phase conductor, no polarity at DC input)
ON
Operation indicator LED
LO
DC LOW indicator LED
Vout ADJ.
Trimmer-potentiometer for Vout adjustment
CIRCUIT SCHEMATIC
‧Block diagram for DRA10 series
L
Fuse
Line
Filter
N
Inrush Current
Switching
Limiter and
Device
Rectifier
Y
Control
Vo +
Rectifier
Current
Detection
Vo -
Opto Isolation
Reference &
Error Amp.
Opto Isolation
Over Voltage
Detection
Vout
ADJ.
Output Level
Detection
DC ON
(Green LED)
DC LOW
(Red LED)
TYP. CURRENT LIMITED CURVE
v
DRA10-24
Output Voltage [ % ]
Hiccup mode
100
50
t
Time
DERATING CURVE
TYP. EFFICIENCY CURVE
DRA10-24
EFFICIENCY [ % ]
Power out [ % ]
100
75
0
-20
www.chinfa.com
2011.01.27
61
Temperature [ oC ]
71
85
80
75
70
65
60
55
50
45
40
35
10
230 Vac
115 Vac
25
50
Power out [ % ]
75
100
[email protected]
P4
DRA10 SERIES
AC - DC DIN RAIL MOUNTABLE POWER SUPPLY
INDUSTRIAL CONTROL EQUIPMENT
FEATURES
‧UL / cUL / TUV / CE
‧UNIVERSAL INPUT 90~264VAC
‧SHORT CIRCUIT PROTECTION
‧INTERNAL INPUT FILTER
‧2 YEARS WARRANTY
R
R
R
H H H
Class I, Div 2
UL 1310
a
UL 60950-1
IND. CONT. EQ.
UL 508
EN 60950-1
MODEL LIST
MODEL NO.
INPUT
VOLTAGE
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
Single Output Models
DRA10-05A
90~264VAC
10 WATTS
+ 5 VDC
2000 mA
71%
73%
DRA10-12A
90~264 VAC
10 WATTS
+ 12 VDC
840 mA
73%
75%
DRA10-15A
90~264 VAC
10 WATTS
+ 15 VDC
670 mA
74%
76%
DRA10-24A
90~264 VAC
10 WATTS
+ 24 VDC
420 mA
74%
76%
max.
max.
unit
unit
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
GENERAL
Conditions
Conditions
Characteristics
min.
min.
typ.
typ.
Switching frequency
Vi nom, Io nom
Isolation voltage
Input-Output
3000 / 4242
VAC / VDC
Input-FG
1500 / 2121
VAC / VDC
132
Isolation resistance
Input-Output, @ 500VDC
100
Ambient temperature
Operating at Vi nom
-20
o
KHz
MΩ
o
+ 71
o
2.5
o
C
Derating (see derating curve)
Vi nom, from +61 C to +71 C
Storage temperature
Non operational
-25
+ 85
Relative humidity
Vi nom, Io nom
20
95
% RH
Temperature coefficient
Vi nom, Io min
± 0.03
% / oC
MTBF
o
Bellcore Issue 6 @40 C, GB
Altitude during operation
IEC 60068-2-13
Dimension
Screw terminal type
Cooling
Free air convection
Pollution degree
www.chinfa.com
2011.01.27
%/ C
o
C
5V model
801000
Hours
12V model
803000
Hours
15V model
805000
Hours
24V model
808000
Hours
4850
L90 x W22.5 x D114
m
mm
2
[email protected]
P5
DRA10 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
INPUT SPECIFICATIONS
Characteristics
Rated input voltage
Conditions
Absolute input max. range
Io nom
Ta min ... Ta max,
Io nom
Input current
Vi : 115 / 230 VAC, Io nom
Rated input current
Vi : 90 VAC, Io nom
Line frequency
Vi nom, Io nom
Inrush current
Power dissipation
Vi : 115 / 230 VAC , Io nom
Leakage current
min.
AC in
DC in
typ.
max.
unit
100
240
VAC
90
120
264
375
VAC
VDC
200 / 130
47
Vi : 230 VAC, Io nom
mA
300
mA
63
10 / 18
Hz
A
5V model
4.0
W
12V model
15V model
3.4
W
3.3
W
24V model
2.8
W
Input-Output
0.25
mA
3.5
mA
max.
unit
Input-FG
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
Output voltage accuracy
(Adjusted before shipment)
Vi nom, Io max
0
Minimum load
Line regulation
Vi nom
Io nom, Vi min ...Vi max
0
Load regulation
Vi nom, Io min ...Io nom
Voltage trim range
Vi nom,
0.8 Io nom
Rated continuous loading
+ 20
Rise time
Vi nom, Io nom
Vi nom, Io nom
12V model
15V model
0.84 A @ 12Vdc / 0.72 A @ 13.8 Vdc
24V model
0.42 A @ 24Vdc / 0.34 A @ 28.8 Vdc
25 / 100
0.67 A @ 15Vdc / 0.58 A @ 17.25 Vdc
with 3500μF CAP
Vi nom, Io nom
Ripple & noise
Vi nom, Io nom, BW = 20MHz
Power back immunity
Vi nom, Io nom
1 second
Vi nom, 1~0.5 Io nom
Vi nom, Io nom
1000
ms
ms
1500
ms
150
ms
500
ms
150
ms
2
ms
50
mV
5V model
7.5
VDC
12V model
15V model
18
VDC
22
35
VDC
24V model
Vi nom, Io nom
%
2 A @ 5Vdc / 1.7 A @ 5.75 Vdc
with 3500μF CAP
Fall time
Transient recovery time
DC ON indicator threshold
at start up (Green LED)
%
- 10
Vi nom, Io nom
Vi nom, Io nom
Vi nom, Io nom
%
24V model
5V model
Turn on time
Capacitor load
%
- 10
Vi : 115 / 230 VAC , Io nom
3500
VDC
μF
5V model
3.5
4.5
VDC
12V model
15V model
9.0
10.8
VDC
11.0
13.5
VDC
18
21.6
VDC
3.5
4.5
VDC
9.0
10.8
VDC
11.0
13.5
VDC
24V model
5V model
12V model
15V model
24V model
Efficiency
%
±1
5V...15V models
Vi nom
%
+1
±2
+ 15
Hold up time
DC LOW indicator threshold
after start up (Red LED)
typ.
Vi nom, Io nom, Po / Pi
VDC
18
21.6
Up to 76%, See model list and typ efficiency curve
CONTROL AND PROTECTION
Characteristics
Conditions
min.
Input fuse
Internal surge voltage protection
Rated over load protection
www.chinfa.com
2011.01.27
typ.
unit
max.
T2A / 250VAC internal
IEC 61000-4-5
Vi nom (see typ current limited curve)
Varistor
110
145
%
[email protected]
P6
DRA10 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
CONTROL AND PROTECTION
Characteristics
Over voltage protection
Conditions
Vi nom, Io nom (Auto Recovery)
typ.
min.
unit
max.
145
125
Output short circuit
Hiccup mode
Degree of protection
IP20
%
APPROVALS AND STANDARDS
UL / cUL
UL 508 Listed
UL 60950-1, UL 1310 Class 2 Power Recognized
ISA 12.12.01(Class I, Division 2, Groups A, B, C and D)
TUV
EN 60950-1, CB scheme
CE
EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3
EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3
EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4
EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11
ENV 50204 Level 2, EN 61204-3
CCC
GB4943, GB9254, GB17625.1
Vibration resistance
meet IEC 60068-2-6 (Mounting by rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis )
Shock resistance
meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face)
PHYSICAL CHARACTERISTICS
Case size
90 x 22.5 x 114 mm (3.6 x 0.89 x 4.49 inches)
Case material
Plastic
Weight
120 g
Packing
0.21 kg ; 56
/ 12.5 kg / 2.16 CUFT
MECHANISM & PIN CONFIGURATION
mm [inch]
22.50 [0.89]
2 1
V- V+
90.00 [3.60]
DC Output
LO
ON
Vout ADJ.
N L
3 4 5
www.chinfa.com
2011.01.27
114.00 [4.49]
CONSTRUCTION
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safeIy and
firmly on the rail.
INSTALLATION
Ventilation / Cooling
Normal convection
All sides 25mm free space
For cooling recommended
Connector size range
Screw terminal:
AWG26-12 (0.2~2.5mm2 ) flexible / solid cable,
connector can withstand torque at maximum 5
pound-inches.
4~5 m/m stripping at cable end recommends
Use copper conductors only, 60 / 75oC
GENERAL TOLERANCE
0.00[0.00] - 30.00[1.18]
±0.30[0.01]
30.00[1.18] - 120.00[4.72]
±0.50[0.02]
[email protected]
P7
DRA10 SERIES
PIN ASSIGNMENT
Designation
OUT
PIN NO.
1
2
Description
V+
Positive output terminal
V -
Negative output terminal
Ground this terminal to minimize high-frequency emissions
IN
3
4
OTHER
5
N
Input terminals (neutral conductor, no polarity at DC input)
L
Input terminals (phase conductor, no polarity at DC input)
ON
Operation indicator LED
LO
DC LOW indicator LED
Vout ADJ.
Trimmer-potentiometer for Vout adjustment
CIRCUIT SCHEMATIC
‧Block diagram for DRA10 series
L
Fuse
Line
Filter
N
Inrush Current
Switching
Limiter and
Device
Rectifier
Y
Control
Vo +
Rectifier
Current
Detection
Vo -
Opto Isolation
Reference &
Error Amp.
Opto Isolation
Over Voltage
Detection
Vout
ADJ.
Output Level
Detection
DC ON
(Green LED)
DC LOW
(Red LED)
TYP. CURRENT LIMITED CURVE
v
DRA10-24A
Output Voltage [ % ]
Hiccup mode
100
50
t
Time
DERATING CURVE
TYP. EFFICIENCY CURVE
DRA10-24A
EFFICIENCY [ % ]
Power out [ % ]
100
75
0
-20
www.chinfa.com
2011.01.27
61
Temperature [ oC ]
71
85
80
75
70
65
60
55
50
45
40
35
10
230 Vac
115 Vac
25
50
Power out [ % ]
75
100
[email protected]
P8