FUJI EDS10-79C

PAPERLESS RECORDER
DATA SHEET
PHU
OVERVIEW
This is a paperless recorder that displays measured data on
the LCD in real time and stores data in CompactFlash.
The type of input such as thermocouple, resistance bulb,
D.C. voltage (current), etc. can be arbitrarily set to 36 channels at the maximum.
The data stored in CompactFlash can be regenerated on the
screen, and the use of supplied support software allows the
data to be regenerated on a PC screen.
The data recorded in ASCII format can be directly read in a
spreadsheet such as Excel, which facilitates the processing on a PC. (The data recorded in binary format cannot
be read in.)
FEATURES
1. Large capacity storage by CompactFlash
Measured data is periodically stored in CompactFlash.
In case of 512 MB, for example, display files for about 2
year and a half (display refresh cycle 30 sec) can be taken
up (in case of ASCII data format, 9 channels, maximum/
minimum recording).
2.Quick search and display of past data
Data stored in CompactFlash can be displayed in succession by scrolling the screen.
3.Various display capability
Depending on the object of measurement, the most
suitable display format can be selected from a variety of
formats including bar graph display, trend display, digital
display, etc.
4.PC support software supplied as standard
Loader software that enables easy display and change of
set data and data viewer software that regenerates the
data stored in CompactFlash are supplied as standard.
5.36-point recording
12 types of thermocouples, 2 types of resistance bulbs
and DC voltage/current input can be recorded up to 36
points.
6.LCD extinguishing function
Automatically extinguishes the LCD if nothing is operated
for certain time. You can set the time after a lapse of
which the LCD is extinguished via parameter "LCD extinguishing time". The settable range is 0 to 60 minutes.
Setting at 0 minute overrides the function, whereby the
LCD will never extinguish.
This function prevents the backlight life from shortening
uselessly. During the extinguishment, the power consumption can be reduced.
7. Ethernet function (Option)
FTP, Web server, e-mail and MODBUS-TCP are available
using 10Base-T.
SPECIFICATIONS
Input system
Number of input points:
9, 18, 27 or 36 points (Can be selected
at the time of purchase)
Input circuit:
Input mutual isolation (See ”Others” on
page 4 for the withstand voltage)
Resistance bulb measured current:
about. 1 mA
Measuring cycles:
9 or 18 points….100ms cycles
27 or 36 points….200ms cycles
Recording cycle: 1 second to 12 hours
Input types:
Thermocouple, resistance bulb, dc
voltage, and dc current (Shunt resistors
are fitted in input terminals).
Note) Provide a shunt resistor (type:
PHZP0101) separately.
Measuring range
Input types
Thermocouple
B
R
S
K
E
J
T
N
W
L
U
PN
Resistance bulb JPt100
Pt100
Ni100
Pt50
Cu50
Reference range
400.0
0.0
0.0
–200.0
–200.0
–200.0
–200.0
0.0
0.0
–200.0
–200.0
0.0
–200.0
–200.0
–60.0
–200.0
–50.0
0.00
50mV
0.0
500mV
1.000
1-5V
0.000
0-5V
Note) B, R, S, K, E, J, T, N :
JIS C 1602, DIN IEC 584-1
W : 5%Re-26%Re · W
(Hoskins Mfg. Co. USA)
L : Fe-Cu · Ni (DIN 43710)
DC voltage
to 1760.0°C
to 1760.0°C
to 1760.0°C
to 1370.0°C
to 800.0°C
to 1100.0°C
to 400.0°C
to 1300.0°C
to 1760.0°C
to 900.0°C
to 400.0°C
to 1300.0°C
to 600.0°C
to 600.0°C
to 180.0°C
to 600.0°C
to 200.0°C
to 50.00mV
to 500.0mV
to 5.000V
to 5.000V
U : Cu-Cu · Ni (DIN 43710)
PN: Platinel
JPt100 : JIS C 1604-1989 (Old JIS Pt 100)
Pt100, Pt50 : JIS 1604, DIN IEC 751
EDS10-79c
Date
Dec. 5, 2011
PHU
Selection of input types:
By key operation on the front panel. Note
that the same input type (thermocouple,
resistance bulb, voltage) should be set every 2 channels. Refer to "Setting method
of input types" for details.
Burn-out function:
Provided as standard for thermocouple
and resistance bulb inputs. If the input
has been open-circuited, the recording
level swings over 100%.
Thermocouple burn-out current:
approx. 0.2 µA
Input filter function:
Settable for each channel (primary delay
filter)
Time constants are settable in the range
from 0 to 900 sec.
Scaling function:Possible by dc voltage (current) input
Scaling range: -32767 to 32767
Decimal position:
settable at any point
Unit symbol: Selectable out of 125 different units or 12 user
units of up to 7 characters.
Subtraction function:
Subtraction between each channel is
allowed.
Totalizing function:
The measured value of each channel
can be totalized. Applicable to daily,
monthly, annual or external input totalizing.
F value calculation function:
F value (extinction value of bacteria by
sterilization by heating) can be calculated from the measured temperature
by each channel.
Square rooter function:
Square rooter can be performed
against the input value per each channel.
Computation function:
The following calculation is available with
the computation function.
(1)Computation function:
Addition, subtraction, multiplication,
division, absolute value, exponential,
square-root extraction, LOG, LN, EXP,
humidity, maximum, minimum, average, and integration.
(2)Computation input enable:
Analog input (Ch1 to 72), integration
input (Ch1 to 72), DI (DI1 to 16), communication input (No.1 to 36), and
constant number (No.1 to 60).
Indication system
Indicator:
2
12” TFT color LCD (800 x 600 dots)
with backlight, no contrast adjustment.
On the LCD, certain picture elements
remain lit or extinguished. On account
of the nature inherent to LCD, the
brightness may be non-uniform. But,
such are not troubles.
Color of indication:
14 colors
Applicable language:
English, French (switchable)
Life of backlight:50,000 hours in terms of total lighting
time.
(Replace the backlight as a set of display
unit. If the LCD extinguishing function is
resorted to, the LCD can be used longer
as much.)
Trend display: Direction: vertical and horizontal
Number of channels: 10, 6 or 4 channels
per screen group. (Input: 72 points at the
maximum).
Display refreshment cycles:
select from 1 second to 12 hours
Scale display or no-display can be selected.
Bar graph display:
Number of channels: 10, 6 or 4 channels
per screen group. (Input: 72 points at the
maximum).
Display refreshment cycles: 1 second
Analog meter display:
Number of channels: 10, 6 or 4 channels
per screen group. Display in bar graphs
or in analog meters can be selected.
Display refresh cycle: 1 second
Digital display: Number of channels: 10, 6 or 4 channels per screen group. (Input: 72 points
at the maximum).
Display refreshment cycles: 1 second
Totalizing data display:
Number of channels: 10, 6 or 4 channels
per screen group. (Input: 72 points at the
maximum).
Display refresh cycle: 1 second
Event summary display:
Alarm summary and message summary
can be displayed. The message occurrence information and message display
can be switched.
Ethernet log display:
E-mail sending, FTP server log in/off and
MODBUS TCP/IP communication start/
stop can be displayed.
Parameter display/set:
Already-set Data Display and Set Change
Display screen
TAG indication: Number of characters to be displayed:
Up to 8 characters
Up to 8 characters (Note 1) at 10 or 6
channel display.
Up to 16 characters at 4 channel display.
Note 1: Up to 7 characters only can be
displayed on certain screens.
Characters to be displayed:
Alphanumerics
Tag , unit and channel No. display:
Which can be displayed depends on the
particular screen. Refer to the table below.
(Keywords only are extracted.)
Screen
Trend
Bar graph
Channnels per
screen
4 or less
5, 6
7 or more
6 or less
7 or more
Analog
meter
Instantaneous
value
 : Displayed
 : 1 item only can be displayed
– : Nothing can be displayed
Tag 1



Item
Tag 2 Unit
All
–

–

All
–

ch Np.



All
Historical trend display:
Displays past recording data read from
compact flash, currently recording data or
just recorded data. The recording chart can
be scrolled or, via time designation, the
control can jump to an arbitrary recording
chart.
Number of screen groups:
8 groups (Up to 10 channels per 1
group can be registered.)
Keyboard
No. of Keys:
Function:
8
Use to select various screens and set
various parameters.
Recording function
External memory media:
Compact Flash card
Format according to FAT16 or FAT. Otherwise, reading and saving are impossible.
Recording capacity:
1 GB maximum (compact flash). Limiting
the recording file to 64 MB is recommended (for 112 hours if display refresh
cycle is 1 second. See Table 1 (p. 6).)
If impossible, up to 256 MB is tolerated. A file recorded beyond could not
be opened.
* Please change the compact flash every
six month to prevent the data losing.
Recording method:
Turning ON the REC key allows measured
data to be written at fixed cycles.
Recorded as a new file whenever the
recording starts.
Data save cycles:
Linked to the display refreshment cycles
on the ”Real Time Trend” screen. However, they are automatically set to about
1 minute if the refreshment cycles are
set to less than 1 minute.
Trend data:
Measurement data sampled at measurement cycle is saved in terms of
mean value, instantaneous value or
maximum/minimum value.
Event data:
Saves alarm data and message data.
Further saves power ON and OFF, if any,
after starting recording.
Totalizing value data:
Tot alizing value dat a at designat ed timing is recorded per channel.
Totalized value data at designated totalized value recording cycle or the sum total
is recorded in the totalizing file. You can
choose which type you want to record.
For each cahnnel. it can be select as
totalizing action from Analog input totalization, Digital input count or period
of Digital input ON, and it can be select as totalizing period type from Dairy,
Weekly, Monthly, Annual, Periodic,
Dairy (time set) or External input signal.
Even if a power failure occues during totalization and then the power is restored,the
totalization restarts from the value before
power failure.
Configuration data:
Configuration data can be saved. And this
data can also download to recorder.
Storage capacity:
Approximately 3 years when the display
refresh cycle is 30 seconds (in case of
9-channel recording in ASCII data format,
and 512 MB compact flash used). Refer
to Table 1.
Residual capacity of memory:
Indicates how much of the memory card
has been used on the screen. If the
residual capacity is none, the recording
stops.
Compact flash card form:PHZP2801
(CF card)
(If a card other than the above is used,
no operation assurance is ensured.
Meanwhile, as for other CF cards for
which operation check will have been
completed, the results will be posted on
our company's homepage sequentially.
Please refer to this website.)
Data format:
Either of ASCII or binary format can be
selected. (Switching cannot be made
while the recording is in progress. In
the case of ASCII format, the data can
be directly read on Excel, etc. The data
recorded in binary format cannot be
read directly.)
Approximately 166 bytes per sampling
for maximum/minimum recording of
9-channel input in ASCII format, or
approximately 40 bytes for maximum/
minimum recording of 9-channel input
in binary format.
Alarm function
No. of settings: Up to 4 alarms for each channel are settable.
Type of alarm: High/Low limits
Indication:
Status (alarm types) is displayed on
digital display unit when an alarm occurs.
Historical display on alarm summary (Alarm
start/cancel time and alarm types)
3
PHU
Set within the recording range of 0 to
100%
Acts on high or low limit alarm, and does
not affect the battery alarm nor memory
full alarm.
Relay output:
Number of points; 20 (option: Up to 2
cards with relay output can be mounted.)
Transistor output (open collector output):
16 points (option)
Alarm latch function:
Holds alarm indication and alarm output
even after measurement value has left
the alarm range.
ON/OFF operation is performed according
to key setting.
Hysteresis:
Power supply
Rated power voltage:
100 to 240V AC
Range of operating voltage:
90 to 264V AC
Supply frequency:
50/60Hz ±2% (both employable)
Power consumption
Power voltage
Consumption
100V AC
About 65VA
240V AC
About 80VA
Signal source resistance:
Thermocouple input .… 1kΩ or less
Resistance bulb input .… 10Ω/wire or less
(resistance of each wire of 3-wire system
should be balanced).
Voltage input .… 0.1% or less of input
resistance
Mounting posture:
Forward tilt 0, backward tilt within 30,
horizontal 0
Warm-up time: One hour or more after power ON
*1: In case of the 12th digit of ordering code is ”Y”.
*2: In case of the 12th digit of ordering code is ”E”.
Reference standard
Accuracy/resolution:
Measuring conditions (23±2˚C, 65±10%
RH, power voltage, frequency fluctuation
within ±1%, no external noise, warm-up
time of 1 hour or more, vertical mounting, standard values of signal source
resistance and wiring resistance... within
1% )
Input types
Thermocouple B
R
S
K
E
J
T
N
W
L
U
PN
Resistance JPt100
bulb
Pt100
Pt50
Structure
Mounting method:
Panel-mounted (vertical panel)
Thickness of panel:
2 to 26 mm
Materials:
Stainless steel for case, PC-ABS for
bezel
Color:
Silver for case, Munsell N2.0 (black) for
bezel
External dimensions:
300 (W) × 300 (H) × 220.5 (D) mm
Mass:
About 4.7 kg (9-point input, without option)
About 6.4 kg (full option)
External terminal board:
Input terminal: M3 screw terminal
Power terminal: M4 screw terminal
Operating condition
Power supply voltage:
90 to 264V AC
Power supply frequency:
50/60Hz ±2% (sharing)
Ambient temperature:
Without Ethernet function: 0 to 50°C*1
With Ethernet function: 0 to 40°C*2
Ambient humidity:
20 to 80%RH
Vibration:
10 to 60Hz 0.2m/s2 or less
Shock:
None
Magnetic field: 400 A/m or less
4
DC voltage
Digital indication
accuracy
Note 1
Digital indication
resolution
±(0.15%+1 digit)
±(0.3%+1 digit)
for the range shown below
Thermocouple B :
400 to 600°C
Thermocouples R and S :
0 to 300°C
Thermocouples K, E, J, T,
L and U : -200 to -100°C
0.1°C
±(0.15%+1 digit)
0.1°C
Ni100
±(0.5%+1 digit)
Cu50
50mV
500mV ±(0.15%+1 digit)
5V
10V
100V
1mV
Note 1) Digital indication accuracy is a percentage (%) with respect to
input range of 1 page.
Note 2) No error of reference contact compensation of thermocouple is
included.
Error of reference contact compensation:
K, E, J, T, N, L, U, PN: ­±0.5˚C
R, S, B, W: ±1.0˚C
(when measured at 0˚C or more)
Max. input voltage:
Thermocouple, resistance bulb,
DC voltage: ±10V DC (continuous)
Input impedance: Thermocouple,
DC voltage: About 1MΩ
Others
Clock:
With calendar function (Christian era)
Accuracy: ±50 ppm or less (monthly error:
about 2 minutes)
However, time error at power ON/OFF is
not included.
Memory backup:Parameters are saved to the internal
non-volatile flash memory.
The clock is backed up with built-in lithium
battery.
Trend data is not backed up.
Insulation resistance:
100 MΩ (when measured between each
terminal and ground by using a 500V DC
megger)
Withstand voltage:
Input terminal – input terminal:
500 V AC, 1 min
Power terminal – ground:
2000V AC, 1 min
Input terminal – ground:500V AC, 1 min
Alarm terminal (cont act output) –
ground:
2000 V AC, 1 min
Alarm terminal (contact output) – alarm
terminal (contact output):
750 V AC, 1 min
Communication terminal – ground:
500 V AC, 1 min
Alarm terminal (open co ll e c t o r ) –
ground:
500 V AC, 1 min
Power terminal – input terminal:
500 V AC, 1 min
Effect on operation
Effect of power supply fluctuation conditions:
For the fluctuation in the range from 90
to 264V AC (frequeucy: 50/60Hz)
Reading change: ±(0.2%+1 digit) or lower.
For the fluctuation in the range from 47
to 63Hz (power voltage: 100V AC)
Reading change: ±(0.2%+1 digit) or lower.
Effect of input signal resistance:
Thermocouple input: 50µV±1 digit per
100Ω
DC voltage: Fluctuation for resistance
value equivalent to 0.1% of the input
resistance: ±(0.2%+1 digit) or lower.
Reistance bulb (for wiring resistance of
10Ω for 1 line (the same for 3 lines))
Reading change: ±(0.2%+1 digit) or lower.
Effect of ambient temperature:
Reading change: ±(0.3%+1 digit)/10˚C or
lower.
Effect of Mounting position:
For the backward 30˚ slant
Reading change: ±(0.2%+1 digit) or lower.
Effect of vibration:
When sine wave of 10 to 60Hz with the
acceleration of 0.2m/s 2 is applied in each
direction for 2 hours.
Reading change: ±(0.2%+1 digit) or lower.
Safety and EMC standard
Safety standard: Based on IEC61010-1
EMC standard: Based on EN61326
Transportation/storage conditions
Temperature:
Humidity:
-10 to +60˚C
5 to 90%RH
Vibration:
Shock:
10 to 60Hz, 2.45 m/s2 or lower
294m/s2 or lower (packed state)
Additional function (option)
■ Alarm relay output (11th digit of code symbols: ”1”,
”2”, ”4” or ”5”)
Up to 2 cards with 10-point relay output can be
mounted. (Maximum 20 points)
Terminal structure: M3 screw terminal
Alarm relay output:
1a contact output (10 points/card),
Individual channel or common output (OR
output) allowed.
Rating: Contact capacity 240V AC/3A,
30V DC/3A (Resistive load).
■ Alarm open collector output (11 digit of code symbols
is ”3”, ”4” or ”5”)
Card having 16 alarm points (open collector output)
can be mounted.
Terminal structure:
M3 screw terminal
Alarm output: Open-collector transistor output (16
points)
Rating: 30V DC/0.1A (resistance load)
■ DI input (7 digits of code symbol is ”1”)
Card having 16 DI input can be mounted.
Terminal structure: M3 screw terminal
DI input:
No-voltage contact input (16 points).
Contact input allows following controls.
(1) Recording start/stop
(2) Message set
(3) F value calculation reset
(4) Totalizing start/stop
(5) Totalized value reset
(6) LCD (backlight) lighting
(7) E-mail sending
Input pulse width:
ON pulse width: 400msec or more
OFF pulse width: 400msec or more
Ethernet (Option)
The following can be performed through the Ethernet
function.
■ HTTP server (Internet Explorer 6 is available) Note 1
Measurement display:
Digitally displays the measurement of
each channel of the recorder and alarm
occurrence status.
Event summary display:
Displays event summary including alarm
ON/OFF and issuance of messages.
Main unit information display:
Displays memory use conditions and
information on the main unit such as
the battery end warning.
Integrated value display:
Digitally displays the integrated value of
each channel of the recorder.
■ FTP server (Internet Explorer 6 available.) Note 1
File download: Record files stored in compact flash
(CF) can be downloaded from the
browser.
5
PHU
Record files stored in CF can be deleted
from the browser.
Access authentication:
Authenticates access authority to FTP
server.
■ SMTP (e-mail client)
Transmits e-mails to specified address
under the following conditions.
(1) When an alarm turns on or off
(2) When DI is set to ON or OFF
(3) When an error occurs to the main
unit (such as low battery or no
memory space)
(4) At specified intervals
■ MODBUS TC/IP
Data read:
Settings can be read through MODBUS
TCP/IP communication.
Data write:
Settings can be written through MODBUS TCP/IP communication.
Note1: Neither Netscape nor Mozilla Firefox
are available.
File delete:
Standard functions
Function
Record range
voluntary setting
Input type setting
Input type can be set by channel.
(Key operation on the front face)
Set the same input type for every 2 channels.
Skip function
Trend display
Skips arbitrary channel display/recording.
Time display: Time is displayed at the top of the
trend display screen.
Alarm display: On occurrence of an alarm and the
restoration, alarm is displayed in the
alarm display field.
The compact flash usage is displayed with a
bargraph at the top.
TAG name display
Screen name
display
Unit creation
By channel, Maximum of 8 characters.
Displays the screen name (maximum of 16
characters).
Industrial units can be arbitrarily created, Maximum
of 7 digits, 12 types.
Arbitrary scaling is allowed in the case of DC
voltage input. Decimal point position can also be
arbitrarily set in the range from -32767 to 32767.
Scaling function
PV shift
Shift the zero point and slant of the reading.
Input filter
Prevents sudden fluctuation of input for each
channel (primary delay filter).
Time constant: 0 to 900 seconds.
Burnout function
Displays the break of thermocouple/resistance bulb
input by scaling out to 100% side.
Historical
trend display
Regenerates and displays the data stored in the
compact flash by scrolling the screen.
Displays data of a designated time.
Support software
The following software is provided as standard.
•Applicable PC: PC/AT-compatible machine
•Operation on PC98-series machines by NEC is not guaranteed.
•Operation on self-made or shop-brand PCs is not guaranteed.
■ Loader software for PC
Major function: Performs various parameter setting/
change of the main unit
O/S: Windows 2000/XP (Windows Vista is
not supported.)
Required memory:
64MB or larger
Disk drive:
Windows 2000/XP-capable CD-ROM
Hard disk capacity:
Free capacity of 30MB or larger required
Printer: Windows 2000/XP-capable printer and
printer driver
Note) PC loader communication cable (type PHZP1801) is
separately required.
■ Data viewer software
Major function: Regenerates the past trend record on
the PC from the data in the compact
flash. Provided with historical trend
display and event display functions.
Data can be changed to CSV file.
O/S:
Windows 2000/XP (Windows Vista is
not supported.)
Required memory:
64MB or larger
Disk drive:
Windows 2000/XP-capable CD-ROM
drive
Hard disk drive: Free capacity of 30MB or larger required
Printer:
Windows 2000/XP-capable printer and
printer driver
6
Description
Recording range can be set by channel.
Table 1. Recording capacity
The recording can be made for the period of time listed
in the tables shown below under the following conditions.
CompactFlash size
64MB
•9 input points
Display upgrade cycle 1 sec
10 sec
30 sec
1 min
10 min
•Recording data format: ASCII
Recordable
capacity
•Recording type: Maximum/minimum
recording
112 hours 46 days 140 days
280 days 7.7 years
(about)
•No alarm, nor message, nor other events.
CompactFlash size
Display upgrade cycle
Recordable capacity(about)
256MB
1 sec
10 sec
30 sec
1 min
18 days 187 days 1.5 years 3 years
•When the number of input points goes on increasing, the
period becomes as follows.
18 input points; The period is approximately one half of
those listed in the table.
27 input points; The period is approximately one-third
of those listed in the table.
36 input points; The period is approximately one-fourth
of those listed in the table.
•In binary format, the period is approximately 4 times as
long as those listed in the table.
•For recording type of mean or instantaneous value, the
number of days is approximately 2 times as long.
When compact flash is not used, up to 6M bytes of
the recording data and the event data can be stored
in the main unit. (In case of 32-channel in Max./Min.
recording, approximately 400,000 data can be stored. For 11 hours at the display refresh cycle of 1 second. The number of the save data varies depending on the
number of the event data.
CODE SYMBOLS
PHU
4 5 6 7 8 9 10 11 12 13
0 0
1 1
Y
Digit
Specifications
Note
4 <Number of input points>
1
9 points
2
18 points
3
27 points
4
36 points
7 <DI input>
Without
With (16 points)
8 <Modification No.(fixed)>
9 <Display (instruction manual)>
English
11 <Alarm output>
Without
10 relay points
20 relay points
Transistor (open collector) 16 points
10 relay points + transistor
(open collector) 16 points
20 relay points + transistor
(open collector) 16 points
12 <Ethernet>
Without
With
0
1
1
E
0
1
2
3
4
5
Y
E
SCOPE OF DELIVIRY
Item
Quantity
Recorder
1
Panel mounting bracket
2
CD-ROM PC support software instruction
manual
1
Noise filter for the power supply
1
OPTIONAL ITEMS
Item
Code
Specification
Shunt resistor for DC
current input
PC loader communication
cable
PHZP0101
10Ω ± 0.1%
PHZP1801
Length 3m with
connector
USB-A/USB miniB
terminal *
CD-ROM with instruction
PHZP2501
manual and support software
PC card adapter
PHZP0501
For compact flash
Compact flash
PHZP2801-512
PHZP2801-01G
512MB
1GB
* Shape of this cable is shown below
USB (A) male – USB (Mini-B ) male
B
7
PHU
OUTLINE DIAGRAMS (Unit : mm)
PANEL MOUNTING TYPE
In the case of 9-point input
Alarm output
transistor terminal
Panel
Alarm output
relay terminal
220.5
300
175
26
Ethernet terminal
(option)
DI input terminal
Power terminal
100-240VAC?`
L
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
N
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
DO1-10
?iRY?j
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11-20
?iRY?j
VPD
280
300
DI
0V
DO21 DO22 DO23 DO24 DO25 DO26 DO27 DO28 PCD
VPD
DI2
DI1
DI
0V
DO29 DO30 DO31 DO32 DO33 DO34 DO35 DO36 PCD
DI9
DI4
DI3
DI10
DI11
DI5
DI12
DI6
DI13
DI
0V
DI8
DI7
DI14
DI15
DI
0V
DI16
DO21-36
?iTr?j
DI1-16
LAN
Communicator
CH1-CH9
+ TC?^V 1
2
+ TC?^V LOWER
‰º’i 16
17
+ TC?^V
CH1
3
4
18
+ TC?^V -
CH2
5
6
+ TC?^V -
CH6
19
7
CH7
20
8
CH3
9
RCJ
+ TC?^V 10
22
+ TC?^V -
CH4
11
12
+ TC?^V -
21
13
14
+ TC?^V -
CH8
23
24
25
CH5
UPPER
15 ã’i
CH9
26
27
R-MODULE
Rcj
PUSH
280
t
318
Mounting bracket
2 ≤ t ≤ 26
Input terminal (1 to 9 points)
In the case of 18-point input
Alarm output
transistor terminal
Panel
Alarm output
relay terminal
220.5
300
Ethernet terminal
(option)
DI input terminal
Power terminal
175
26
100-240VAC?`
L
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
N
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
DO1-10
?iRY?j
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11-20
?iRY?j
VPD
280
300
DI
0V
DO21 DO22 DO23 DO24 DO25 DO26 DO27 DO28 PCD
VPD
DI2
DI1
DI
0V
DO29 DO30 DO31 DO32 DO33 DO34 DO35 DO36 PCD
DI4
DI3
DI10
DI9
DI11
DI5
DI12
DI6
DI13
DI
0V
DI8
DI7
DI14
DI15
DI16
DI
0V
DO21-36
?iTr?j
DI1-16
LAN
Communicator
CH1-CH9
1
2
+ TC?^V
CH1
3
CH6
18
4
19
+ TC?^V -
CH2
5
+ TC?^V 20
6
CH7
7
8
CH3
9
RCJ
21
+ TC?^V 10
22
+ TC?^V -
CH4
11
+ TC?^V 23
12
CH8
24
13
14
+ TC?^V 25
CH5
UPPER
15 ã’i
CH9
26
27
+ TC?^V 28
29
+ TC?^V LOWER
‰º’i 43
44
CH10 + TC?^V 30
31
CH11
32
CH15 + TC?^V 45
46
47
+ TC?^V -
33
CH16
34
35
CH12 + TC?^V 36
RCJ
48
37
CH13 + TC?^V -
38
+ TC?^V 49
50
39
40
41
CH17 + TC?^V 51
52
CH14
UPPER
42 ã’i
CH18
53
54
R-MODULE
Rcj
+ TC?^V + TC?^V LOWER
‰º’i 16
17
CH10-CH18
R-MODULE
Rcj
PUSH
280
t
2 ≤ t ≤ 26
318
Mounting bracket
Input terminal
(1 to 9 points)
8
Input terminal
(10 to 18 points)
In the case of 27-point input
Alarm output transistor terminal
Panel
220.5
300
Ethernet terminal (option)
Alarm output
relay terminal
DI input terminal
Power terminal
175
26
100-240VAC?`
L
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
N
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
DO1-10
?iRY?j
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11-20
?iRY?j
VPD
280
300
DI
0V
DO21 DO22 DO23 DO24 DO25 DO26 DO27 DO28 PCD
VPD
DI2
DI1
DI
0V
DO29 DO30 DO31 DO32 DO33 DO34 DO35 DO36 PCD
DI4
DI3
DI10
DI9
DI11
DI5
DI12
DI6
DI13
DI
0V
DI8
DI7
DI14
DI15
DI
0V
DI16
DO21-36
?iTr?j
DI1-16
LAN
Communicator
CH1-CH9
1
2
+ TC?^V
CH1
3
4
18
+ TC?^V -
CH2
5
6
+ TC?^V -
CH6
19
7
CH7
20
8
CH3
9
RCJ
+ TC?^V 10
22
+ TC?^V -
CH4
11
12
+ TC?^V -
21
13
14
+ TC?^V -
CH8
23
24
25
+ TC?^V -
CH5
UPPER
15 ã’i
CH9
26
28
29
+ TC?^V LOWER
‰º’i 43
44
27
CH10 + TC?^V 30
31
45
+ TC?^V -
CH11
32
33
CH15 + TC?^V 46
CH16
47
34
CH12 + TC?^V -
35
36
37
CH13 + TC?^V -
38
39
+ TC?^V -
RCJ
48
49
40
41
CH17 + TC?^V -
50
51
52
CH14
UPPER
42 ã’i
CH18
53
54
R-MODULE
Rcj
+ TC?^V + TC?^V LOWER
‰º’i 16
17
CH10-CH18
R-MODULE
Rcj
CH19-CH27
+ TC?^V 28
29
+ TC?^V LOWER
‰º’i 43
44
PUSH
CH10 + TC?^V 30
31
45
46
+ TC?^V -
CH11
32
33
CH15 + TC?^V -
CH16
47
34
35
CH12 + TC?^V 36
RCJ
37
CH13 + TC?^V -
38
39
+ TC?^V -
48
49
40
41
CH17 + TC?^V -
50
51
52
CH14
UPPER
42 ã’i
CH18
53
54
R-MODULE
Rcj
t
280
Mounting bracket
2 ≤ t ≤ 26
318
Input terminal
(1 to 9 points)
Input terminal
(10 to 18 points)
Input terminal (19 to 27 points)
In the case of 36-point input
Alarm output transistor terminal
Panel
220.5
300
175
26
Ethernet terminal (option)
Alarm output
relay terminal
DI input terminal
Power terminal
100-240VAC?`
L
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
N
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10
DO1-10
?iRY?j
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11 DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
DO11-20
?iRY?j
VPD
280
300
DI
0V
DO21 DO22 DO23 DO24 DO25 DO26 DO27 DO28 PCD
VPD
DI11
DI5
DI12
DI6
DI13
DI
0V
DI8
DI7
DI14
DI15
DI16
DI
0V
DI1-16
+ TC?^V 28
29
+ TC?^V LOWER
‰º’i 43
44
+ TC?^V
CH1
3
CH6
4
19
6
31
45
46
47
8
CH3
9
RCJ
+ TC?^V 10
22
+ TC?^V -
CH4
11
12
+ TC?^V -
21
CH11
32
CH15 + TC?^V -
7
CH7
20
CH10 + TC?^V 30
+ TC?^V -
CH2
5
+ TC?^V -
18
CH8
23
13
14
+ TC?^V -
24
25
CH5
UPPER
15 ã’i
CH9
26
27
+ TC?^V 28
29
+ TC?^V LOWER
‰º’i 43
44
CH10 + TC?^V 30
31
CH11
32
45
46
+ TC?^V -
33
CH15 + TC?^V -
CH16
47
34
35
CH12 + TC?^V 36
RCJ
CH28-CH36
+ TC?^V -
CH16
34
35
CH12 + TC?^V 36
RCJ
48
37
CH13 + TC?^V -
38
+ TC?^V 49
50
39
40
41
CH17 + TC?^V 51
52
CH14
UPPER
42 ã’i
CH18
53
54
+ TC?^V 82
83
+ TC?^V LOWER
‰º’i 97
98
CH28 + TC?^V 84
85
CH29 + TC?^V -
86
CH33 + TC?^V 99
100
101
87
CH34
88
89
CH13 + TC?^V -
38
90
RCJ
91
51
41
52
104
93
94
95
CH35 + TC?^V 105
106
CH14
UPPER
42 ã’i
CH18
53
CH31 + TC?^V -
92
+ TC?^V 103
40
CH17 + TC?^V -
50
CH30 + TC?^V -
102
39
+ TC?^V 49
CH19-CH27
33
37
48
54
CH32
UPPER
96 ã’i
CH36
107
108
R-MODULE
Rcj
2
R-MODULE
Rcj
1
CH10-CH18
R-MODULE
Rcj
+ TC?^V + TC?^V LOWER
‰º’i 16
17
R-MODULE
Rcj
t
DI4
DI3
DI10
DI9
LAN
Communicator
CH1-CH9
PUSH
DI2
DI1
DI
0V
DO29 DO30 DO31 DO32 DO33 DO34 DO35 DO36 PCD
DO21-36
?iTr?j
280
Mounting bracket
318
2 ≤ t ≤ 26
Input terminal
(10 to 18 points)
Input terminal (28 to 36 points)
Input terminal (19 to 27 points)
Input terminal
(1 to 9 points)
Panel cutout size
360 MIN
320 MIN
281
+2
0
+2
281 0
9
PHU
EXTERNAL CONNECTION DIAGRAMS
Alarm output relay terminal
M3 screw
DO1
1
DO2
2
DO3
3
DO4
4
DO5
5
DO6
6
DO7
7
DO8
8
DO9
9
DO10
10
11
12
13
14
15
16
17
18
19
Power terminal
20
M4 screw
100 to 240V AC
50/60Hz
Alarm output relay terminal
M3 screw
DO11
21
DO12 DO13 DO14 DO15 DO16 DO17 DO18 DO19 DO20
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Alarm output transistor terminal
DI input terminal
M3 screw
M3 screw
DO21 DO22 DO23 DO24 DO25 DO26 DO27 DO28 PCD
45
46
47
48
49
50
43
44
42
24V DC+ DO29 DO30 DO31 DO32 DO33 DO34 DO35 DO36
0V
VPD
41
51
52
53
55
54
56
57
58
59
DI 0V
61
DI1
62
DI2
63
DI9
60
71
DI6
DI7
DI8
DI 0V
DI3
DI4
DI5
70
64
65
66
67
68
69
DI10 DI11
DI12 DI13 DI14 DI15 DI16
72
74
73
75
76
77
78
Input terminal
Number of input points = 1 to 9 points
CH1
CH2
CH3
CH4
M3 screw
Number of input points = 10 to 18 points
CH5
Voltage +
-
+
-
+
-
+
-
+
Thermocouple +
-
+
-
+
-
+
-
+
CH10
CH11
CH12
CH13
CH14
-
Voltage +
-
+
-
+
-
+
-
+
-
-
Thermocouple +
-
+
-
+
-
+
-
+
-
Resistance
bulb
Resistance
bulb
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
16 17 18 19 20 21
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
22 23 24 25 26 27
Resistance
bulb
43 44 45 46 47 48
49 50 51 52 53 54
Resistance
bulb
RCJ
RCJ
Thermocouple +
-
+
-
+
-
+
-
Thermocouple +
-
+
-
+
Voltage +
-
+
-
+
-
+
-
Voltage +
-
+
-
+
CH6
CH7
CH8
CH9
CH15
CH16
-
+
-
+
CH17
CH18
Number of input points = 19 to 27 points
CH19
Voltage
CH20
CH21
CH22
Number of input points = 28 to 36 points
CH23
+
-
+
-
+
-
+
-
+
-
Thermocouple +
-
+
-
+
-
+
-
+
-
CH28
Voltage
CH29
CH30
CH31
CH32
+
-
+
-
+
-
+
-
+
-
Thermocouple +
-
+
-
+
-
+
-
+
-
Resistance
bulb
Resistance
bulb
55 56 57 58 59 60 61 62 63 64 65 66 67 68 69
70 71 72 73 74 75
Resistance
bulb
82 83 84 85 86 87 88 89 90 91 92 93 94 95 96
76 77 78 79 80 81
97 98 99 100101 102
Resistance
bulb
RCJ
103104105106107108
RCJ
Thermocouple +
-
+
-
+
-
+
-
Thermocouple +
-
+
-
+
-
+
-
Voltage +
-
+
-
+
-
+
-
Voltage +
-
+
-
+
-
+
-
CH24
CH25
CH26
CH27
CH33
CH34
CH35
CH36
Note) For current input, connect an optional shunt resistance to a voltage input terminal.
10
79
80
Selecting input type
The input type is the same every 2 channels.
The input type of channel 2, 4, 6, 8, 11, 13, 15, 17, 20, 22, 24, 26, 29, 31, 33 and 35 can only be set in the same category
of previous channel.
Note, however, that input type can be arbitrarily selected only for channels 9, 18, 27 and 36 irrespective of the type
allocated to other channels.
The following input types are available.
Input type
Details
Thermocouple, 50mV
Resistance bulb
500mV
5V
K, E, J, T, R, S, B, N, W, L, U, and PN thermocouples, 50mV
Pt100, JPt100, Ni100, Pt50 and Cu50
500mV
1 to 5V, 0 to 5V
Example of channel input type selection (for 18 points input)
Input type
Input type
Thermocouple,
50mV
Channel 1
K thermocouple
Channel 2
T thermocouple
Channel 3
1-5V
Channel 4
0-5V
Channel 5
Pt100
Channel 6
JPt100
Channel 7
500mV
Channel 8
500mV
Description
The type of thermocouple can be arbitrarily selected
for each channel.
5V
Resistance bulb
The type of resistance bulb can be arbitrarily selected
for each channel.
500mV
Channel 9
J thermocouple
Thermocouple, 50mV
Input type can be arbitrarily selected for channel 9.
Channel 10
K thermocouple
Channel 11
50mV
Thermocouple,
50mV
The input type of the thermocouple and 50mV is the
same.
Channel 12
Skip
5V
Channel 13
1-5V
Skip and other channel can arbitrarily be selected
irrespective of the input type.
Channel 14
Pt100
Channel 15
Skip
Channel 16
Other channels
Channel 17
500mV
Channel 18
50mV
Resistance bulb
500mV
Thermocouple, 50mV
Input type can be arbitrarily selected for channel 18.
Note 1) Windows2000/XP, Excel, and Internet Explorer are the trademarks or registered trademarks of Microsoft Corporation in the U.S.
Note 2) CompactFlash is the trademark or registered trademark of Sandisk Corporation.
Note 3) Modbus is the trademark or registered trademark of AEG Schneider Automation International.
Note 4) The PC98 Series are the trademark or registered trademark of NEC Corporation.
Note 5) Netscape is the trademark or registered trademark of Netscape Communications Corp.
Note 6) Firefox is the trade mark of Mozilla Corporation.
11
PHU
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/
Information in this catalog is subject to change without notice.
Printed in Japan