FUJI EDS11-109E

MICRO CONTROLLER ” H”
DATA SHEET
PYH
Micro Controller “H”, Fuji's upgraded Z-series controller incorporating a micro processor, provides the digital
communication and high speed operation cycle (100 ms).
It is ideally suited for small scale plant or small scale FA
(Factory Automation).
FEATURES
PYH5
1. Unique 2-size micro controller
(48×96mm, 96×96mm)
RS-485 digital communication has been realized with
these 3-size controllers.
2. High controllability
High speed operation cycle (100 ms) his been attained.
3. PID auto-tuning function
PID parameters can be automatically computed and set
by the controller.
4. Dust/drip-proof front panel
Front panel of dust/drip-proof construction conforms to
IEC IP55 standards.
5. Multi-input, programmable range
Several inputs can be handled by a single controller.
6. Full variety of operation and alarm functions
Various operations and alarms are possible due do the
multiple input/output functions.
7. Full variety of control types
Inverter control type, position feedback control type and
dual control type are available for selection according
to final control devices.
8. Wide range of power supply
The controller operates on power sources within the
range of AC 85 to 265V.
PYH9
SPECIFICATIONS
1. Control operation functions
(1) PID control:
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Proportional band (P): 0 to 3276% (ONOFF operation of controller with dead
band at P=0)
Integral time (I): 0.1 to 3276 sec
Derivative time (D): 0 to 900sec
PID auto-turning
Operation cycle:
100 msec (operation cycle is variable
within the range of 0.1 to 3276 sec)
Input filter: Setting range: 10.0 to 900.0 sec (set to
10.0 sec prior to delivery)
Square-root extraction (router):
In differential pressure conversion, the
flow rate is treated as “0” by the router
cut point. (CUT point is “unused” prior to
delivery.)
Input shift function:
Shift of actual measured value (PV) is
possible by this function.
Intermittent PID control:
Control cycle and control with/without
cycle can be designed without changing
100 msec (normal) of operation cycle.
Non-linear gain:
A function to make a gain non-linearity
by reducing the gain in the vicinity of set
value (SV).
EDS11-109e
Date
Oct. 28, 2003
PYH
2. Table of input/output specifications and alarm
output
Type
Item
Input (measured value)
Control
output 1
Control
output 2
(dual control
type only)
Auxiliary
Auxiliary output
PV/SV/MV
transmission output
Auxiliary
alarm
output
Rating
Inverter con- Position feed- Dual control
trol type
back control
type
type
(PYH9 only)
(PYH5, 9)
(PYH5, 9)
Thermocouple, resistance bulb, voltage,
™
™
™
™
current
...................................................................................................................................................................................
With transmitter power supply DC 4 to
20mA (PYH9 only)
–
™
–
–
mV input: leak current: 3µA
™
™
–
™
AC 200V, 3A (resistive load), 1a contact × 2
Relay contact
AC 220V, 3A (resistive load), 1c contact
Current
DC 4 to 20mA, load resistance 600Ω or less
SSR/SSC drive
DC 10 to 27V at ON, 0.5V DC or less at OFF,
max. current DC 20mA.
Motor-driven
value operation
–
™
™
–
–
™
–
–
™
–
–
Relay contact
AC 220V, 3A (resistive load), 1c contact
–
–
–
Current
DC 4 to 20mA, load resistance 600Ω or less
–
–
–
™
™
SSR/SSC drive
DC 10 to 27V at ON, DC 0.5V or less at OFF,
max. current DC 20mA.
–
–
–
™
™
™
–
™
™
™
–
Analog
DC 1 to 5V, input resistance 1MΩ or more
Valve position
100 to 1000Ω, 3-wire potentiometer
Digital 1
Contact, DC 24V, 15mA (R-ACK or SV selection
™
™
™
™
Digital 2
Ditto (EX-MV command)
Digital 3
Ditto (PYH9 only) (CAS-SV)
™
™
™
™
™
™
™
™
Analog
DC 1 to 5V, input impedance of connected
device 500kΩ or more
™
™
™
™
Digital 1
DC 30V, 0.1A, 1a contact (PYH5: opencollector,
DC 30V, 0.1A)
™
™
™
™
Digital 2
Ditto (PYH9 only)
Digital 3
Ditto (PYH9 only)
™
™
™
™
™
™
™
™
™
™
™
™
–
Main alarm output
AC 220V, 1A, 1a contact × 2
Heater break alarm output
AC 220V, 1A, 1a contact (PYH5: opencollector,
DC 30V, 0.1A)
™
–
–
™
Fault output
DC 30V, 0.1A, 1a contact
™
™
™
™
3. Setting and indication
± 0.2% FS, ± 1 digit
Temperature compensation: ± 1°C
(2) Remote setting input accuracy:
± 0.2% FS
(3) Setting method:
Key switch
(4) Indicating method:
7-segment LED, 4 digits × 2, mode indication (LED lamp)
(1) Accuracy:
4. Power failure backup
Set point values and PID parameters are stored in nonvolatile memory for automatic re-start
5. Status function
Self-diagnosis using watchdog timer
6. Digital communication function
Universal interface:
PS-485: Used for PYH5 and PYH9 as an
option.
2
Fixed set
Point control
type
(PYH5, 9)
7. Operation mode
Remote mode operation, auto mode operation, manual
mode operation
8. Alarm functions
(1) Main alarm: Absolute value upper/lower limit, deviation upper/lower limit, absolute value
lower limit with lower limit hold, deviation lower limit with lower limit hold, deviation upper/lower limit with lower limit
hold, deviation upper/lower limit.
(2) Heater break alarm:
Alarm output with connection to separate-ly installed current transformer (CT).
(3) Auxiliary alarm/limiter:
Measured value upper/lower limit, manipulated output upper/lower limit, set
point value upper/lower limiter, manipulated output upper limiter
(5) Life of output relay:
Mechanical, 10 7 operations (100 ONOFF operations/min)
Electrical, 10 5 operations (20 ON-OFF
operations/min at rated load)
9. Operating and storage conditions
(1) Allowable ambient temperature:
–10 to 50°C
(2) Allowable ambient humidity:
90% RH or less (no condensation)
(3) Storage temperature:
–10 to 70°C
11. Structure
10. General specifications
(1) Power supply: 1 0 0 ( – 1 5 % ) t o 2 4 0 ( + 1 0 % ) V A C ,
50/60Hz
(2) Power consumption:
Approx. 30VA (AC 220V)
(3) Dielectric strength:
Power terminal to ground : 1500VAC
1min.
Power terminal to relay contact output :
1500VAC 1min.
Grand to relay contact output : 1500VAC
1min.
Others : 500VAC 1min.
(4) Insulation resistance:
20MΩ or more (at DC 500V)
(1) Installation: Panel flush mounting
(2) Enclosure case:
Plastic housing
(3) Outline dimensions
Type
Outline dimensions (H × W × D)
Mass (weight)
PYH5
PYH9
96 × 48 × 150mm
96 × 96 × 150mm
Approx. 0.5kg
Approx. 0.8kg
IEC (DIN standards)
(4) Protective structure:
Front panel, IEC IP55
Terminal, IEC IP00
(5) Finish color: Munsell N 1.5 (black)
(6) Terminal:
Compression type terminal (AWG 14)
12. Scope of delivery
Controller, mounting bracket operation manual
CODE SYMBOLS
1 2 3 4 5 6 7 8
9 10 11 12 13
PY H
Description
Size of front panel
48 × 96mm
96 × 96mm
5
9
Control functions
Fixed set point control type
Fixed set point control type (SV select type)
Inverter control type (SV select type)…PYH9 only
Position feedback control type
Position feedback control type (SV select type)
Dual control type
Dual control type (SV select type)
A
B
C
D
E
F
G
Control output 1
Relay contact output
SSR/SSC drive output
DC 4 to 20mA output
Pulse output (position feedback control type only)
1
2
3
4
Control output 2 (dual control type only)
None
Relay contact output
SSR/SSC drive output
DC 4 to 20mA output
0
1
2
3
2
3
Size of front panel 96 × 96mm
Size of front panel 48 × 96mm
Additional specifications 1
None
With heater break alarm (control output, relay contact output only)
0
1
Digital communication function
None
With RS-485
Y
R
Additional specifications 2
None
With external set value input (5th digit B, C, E, G not acceptable)
With external transmission output
A + B (5th digit B, C, E, G not acceptable)
Y
A
B
C
Input specification type
mV/resistance bulb/thermocouple multi-input type
DC 1 to 5V/DC 4 to 20mA multi-input type
DC 4 to 20mA input type with transmitter power supply (5th digit C: inverter control only)
A
B
C
Y
A
B
C
Digital output
None
DO1
DO1-2
PYH9 only
DO1-3
}
3
PYH
OUTLINE DIAGRAM
(Unit:mm)
PYH9 (96 × 96mm)
96
12
150
10
FLT R
A M C1 C2 H
L HB
C
115
PV
SV
MV
SV/MV
A/M
SEL
DATA
ENT
Panel cutout
Note 3)
30
Note 1) Panel thickness: 1 to 8mm
Note 2) Permanent sidewise installation is
possible. For vertical installation,
a minimum space for installation
the bracket should be provided as
shown in the above diagram.
Note 3) When a device with extensive
depth is installed on both sides of
the controller, allow a space of
more than 30mm.
Note 4) Install the fan in the permanent
PYH5 installation.
Note 3)
30
Min.116
92
+0.8
0
Min.100
92 +0.8
0
PYH5 (48 × 96mm)
48
12
150
10
C
96
SV
MV
SV/MV
A/M
SEL
DAT
ENT
Accessory(CT)
92
92
2.36
30
10.5
40
3
4
5
6
a
93
141
189
237
285
M3.depth 4
30
40
7.5
2
15
12
Quantity
2.8
5.8
< Permanent installation >
45 +0.6
0
4
21
15
10
Min.116
Current transformer for heater break alarm
Heater current: For 1 to 30A
Heater current: For 20 to 50A
Type: CTL-6-S-H
Type: CTL-12-S36-8F
7
Note 3)
30
25
a +0.8
0
+0.8
0
Note 3)
Note 3) 30
Min.55
30
+0.8
0
Note 3)
30
2.5
Panel cutout
9
115
PV
30
40
3.5
CONNECTION DIAGRAM
PYH9
With transmitter
Power supply
+
5
+
Digital
communication
RS485
Shield
+
6
A
Input signal (PV)
B
B
(min)
External set value input
External transmission output
+ (max)
Potentiometer for
position feedback
1
TRX1
2
TRX2
3
SHLD
4
PV1
5
PV2
6
PV3
7
SC/
SC 24
C1O
C1C
C1 common
C2C
C2 common
15
0 /CT
18
Io CT input
11
ALM1
ALM2
16
HB
17
Ground
13 AC
Power source
(AC85
265V)
14 AC
DO2
20
21
ALMC
FLT
30
Control output
(position
feedback type)
Close
Common
28
Control output 2
(relay contact output)
29
25
+
Control output 1
DC 4 to 20mA or
SSR/SSC drive
output
+
Control output 2
DC 4 to 20mA or
SSR/SSC drive
output
27
31
32
33
Main alarm 1 output
Main alarm 2 output
Heater break alarm
28
34
30
35
DO1 36
Auxiliary alarm 2
DO3
Auxiliary alarm 3
D 3 22 Auxiliary Di3
23
DIO common
28
Open
30
19
12 G
Control output 1
(relay contact output)
26
27
C2O
+ 8 CAS
+ 9 AO
10 + /CT
27
25
D 1 37
D 2 38
DIO common
39
Fault output
Auxiliary alarm 1
Auxiliary Di1
Auxiliary Di2
PYH5
+
Digital communication
RS485
Input signal (PV)
+
1 TRX1
2 TRX2
Shield
+
3 SHLD
4 PV1
A
B
B
(min)
External set value input
5 PV2
6 PV3
7 SC/
8 CAS
External transmission putput +
9 AO
+
+ (max)
10 + /CT
0
11 0 /CT
CT input
Potentiometer for
position feedback
Ground
Power source
(AC85
265V)
SC 15
C1O
16
C1C
17
C1 common
18
C2O
19
C2C
20
C2 common
21
ALM1
22
ALM2
23
HB
24
25
FLT
DO1
26
27
12 G
D 1 28
13 AC
D 2 29
14 AC
30
DIO common
18
Control output 1
(relay contact output)
19
21
Control output 2
(relay contact output)
16
Open
Control output (position
feedback type)
Close
Common
+
18
Control output 1
DC 4 to 20mA or
SSR/SSC drive output
Alarm 1 output
Alarm 2 output
19
ALM common
+
21
Control output 2
DC 4 to 20mA or
SSR/SSC drive output
Heater break alarm
Auxiliary alarm output
Auxiliary Di2
Auxiliary
Di1
Fauit output
Connecting terminal No. varies with types.
Connect terminals in reference to the terminal nameplate attached to the body.
Note 1)
2)
3)
4)
Power fuse is not installed in the controller. It should be connected exteriorly.
Ensure G terminal is connected to the ground.
Do not use open terminals.
Connect thermocouple, resistor tube, potentiometer input signal directly to PYH.
5
PYH
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan