ULTRASONIC FLOWMETER (2-Path System type) DATA SHEET FSH, FSG, FSD This flowmeter is a fixed type ultrasonic flowmeter based on transit-time measuring method. The flowmeter is a compact and light-weight instrument incorporating the latest electronics and high speed digital signal processing technologies, realizing high performance and easy operation. This high performance flowmeter is used for 2-path system only. FEATURES 1.Compact and light-weight Thanks to the adoption of the latest electronics the flow transmitter size and mass are 1/2 of our traditional instrument. 2.Full variety of sensors The flowmeter can be used with various types of sensors applicable for wide range of pipe size (ø13 to ø6000mm) and fluid temperature (-40 to +200°C). 3.High accuracy The flowmeter is designed for high accuracy (± 1.0%). The adoption of new sound velocity measurement system permits measurements of fluids of unknown sound velocity, and also slightly affection from fluid temperature and pressure. 4.Excellent resistance against aerated flow Fuji's unique ABM feature improves measurement reliability for different flow like slurries, sludge, raw sewage and bubble-contained flow (acceptable up to air bubble of 12% volume at 1m/s velocity). 5.Quick response With the use of high-speed micro-processor suited for digital signal processing, the fast response time is realized. 6.Multi-lingual The following languages are supported for display: Japanese (Katakana), English, German French, and Spanish. 7.Excellent performance and easy operation LCD and function keys are allowing easy configuration and trouble shooting. − LCD with back light − Easy mounting of sensor − Trouble shooting SPECIFICATIONS Operational specifications System configuration: The system is composed of two detectors (Model: FSG, FSD) and one Flow transmitter (Model: FSH), realizing two-path measurement. Flow transmitter (FSH) Detector (FSD) Detector (FSG) Applicable fluid:Homogenous liquid where the ultrasonic signal can be transmitted Bubble quantity: 0 to 12vol% (for pipe size 50A, water, velocity 1m/s) Fluid turbidity: 10000mg/L max. Type of flow: Fully-developed turbulent or laminar flow in a full-filled pipe Applicable flow pipe: Material: Plastics (PVC, FRP, etc.) or Metals (carbon steel, SS, copper, aluminum, etc.) 50 to 6000 mm Pipe size: (inside diameter) Liner: Tar epoxy, mortar, etc. Straight pipe length: Typically 10D for upstream and 5D for downstream. Refer to JEMIS-032 in detail. Velocity: 0 to ±0.3·········±32 m/s Power supply: 100 to 240 Vac+10%/-15%, 50/60Hz or 20 to 30 Vdc EDS6-141d Date Apr. 1, 2011 FSH, FSG, FSD Signal cable: High-frequency coaxial cable and 3-wire shielded cable. Maximum cable length: 150m Allowable temperature limit: 80ºC Coaxial cable (4 pcs) Environment: Non-explosive environment without direct sunlight, corrosive gas and heat radiation Ambient temperature: -10 to +50ºC for flow transmitter, -20 to +80ºC for detector Ambient humidity: 95%RH or less for flow transmitter, 100%RH or less for detector Grounding: Class D (less than 100 ohm) Arrester: Surge absorbers for outputs and power supply incorporated as standard Display device: Graphic LCD (number of pixels: 240x64) with back light Display language: Japanese, English, French, German or Spanish selectable Velocity/Flow rate display: Display of velocity and/or flow rate with flow direction Data: up to 10 digits (decimal point to be counted as 1 digit) Unit: Metric/English system selectable Metric system Velocity m/s ft/s Flow rate L/s, L/min, L/h, L/d, kL/h, ML/d, m3/s, m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s, BBL/min, BBL/h, kBBL/d, MBBL/d ft3/s, ft3/min, ft3/h, Mft3/d, Performance specifications Accuracy : Common type Detector Pipe size (diameter) Applicable pipe material Flow velocity Accuracy 2 to 32m/s 0 to 2m/s 0.75 to 32m/s 0 to 0.75m/s Plastic, metal pipe 2 to 32m/s ø50 to below ø300 0 to 2m/s FSGS31 FSGS50 0.75 to 32m/s ø300 to ø6000 mm 0 to 0.75m/s FSGS32 ø50 to below ø300 FSD32 FSGS51 ø300 to ø6000 mm ±1.0% of rate ±0.02m/s ±1.0% of rate ±0.0075m/s ±1.5% of rate ±0.03m/s ±1.5% of rate ±0.0113m/s 0.5sec Functional specifications Analog output:4 to 20 mAdc (1 point) Max. load resistance: 1k ohm Digital output:+total, -total, alarm, acting range, flow switch or total switch -- arbitrarily selectable Mechanical relay contact: 1 point with socket (replaceable) Normally closed/open selectable Capacity:240 Vac/30 Vdc, 1 A Total pulse: less than 1 p/s (Pulse width: 50, 100 or 200 ms selectable) Transistor open collector: 2 points Capacity: 30 Vdc, 0.1 A Normally off/on selectable Total pulse: less than 1000 p/s (Pulse width: 0.5, 1, 2, 5, 10, 20, 50, 100 or 200 ms selectable) Communication interface: RS-232C equivalent / RS-485 (selectable) Number of connectable units: one (RS-232C)/ up to 31 (RS-485) Baud rate: 9600/19200/38400 bps selectable Parity: none/odd/even selectable Stop bit: 1 or 2 bits selectable Distance: up to 15 m (RS-232C)/up to 1k m (RS-485) Data: velocity, flow rate, +total, -total, status (standard), velocity profile (option) 2 gal/s, gal/min, gal/h, Mgal/d, BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d Note: ˝gal˝ means US gal. Total display: Display of forward or reverse total Data:up to 10 digits (decimal point to be counted as 1 digit) Unit: Metric/English system selectable Total Metric system English system mL, L, m3, km3, Mm3, mBBL, BBL, kBBL ft3, kft3, Mft3, gal, kgal, mBBL, BBL, kBBL, ACRf Configuration: Response time: Transit time method: Power consumption: 20W or less English system Fully configurable on keyboard by menudriven software Zero adjustment: Set zero/Clear available. Damping: 0 to 100s (every 0.1s) configurable for analog output and display Low flow cut off: 0 to 5 m/s configurable Alarm: Hardware fault/process fault can be tied to digital output Burnout: Analog output: Hold/Upper limit/Lower limit/ Zero/Not-used selectable Total: Hold/Count selectable Timer: 0 to 900s (every 1s) configurable Bi-directional range: Forward and reverse ranges configurable independently Hysteresis: 0 to 20% of working range configurable Working range applicable to digital output Auto-2 ranges: Forward 2 ranges configurable independently Hysteresis: 0 to 20% of working range configurable Working range applicable to digital output Flow switch: Lower and upper switching points configurable independently Acting point applicable to digital output Total switch: +total switching point configurable Acting point applicable to digital output Signal cable: Physical specifications Enclosure protection: Flow Transmitter: IP67, Detector: FSG (common type): IP67 (Silicon compound is filled on the terminal part when wiring) FSG (submersible type): IP68 (submersible in water for 5 days) FSD (high temperature type): IP52 Flow Transmitter: wall mount Mounting: Detector: clamped on pipe surface Acoustic coupler: Silicon compound (RTV) Flow Transmitter: aluminum alloy Material: Detector: Detector Sensor housing Sensor cover Guide rail FSGS3 FSGS5 FSD32 PBT PBT SUS304 SUS304 SUS304 – SUS304 + plastic – SUS304 + aluminum alloy FLY8, FLY9 (applicable detector: FSG, FSD) •Structure: High frequency coaxial cable (double shield) •Sheath: Black flame-resisting PVC •Outer diameter: ø7.5mm •Termination: M3.5 amp terminal (flow transmitter side) and M4 amp terminal (FLY8).Note, however, that the detecter side of FSD32 is provided with BNC connector (FLY9). •Mass: Approx. 90g/m Dimensions: Flow transmitter FSH: H240×W247×D134mm Detector: H46×W410×D50mm (FSGS3) H67×W78×D84mm (FSGS5) H205×W530×D52mm (FSD32) Mass: Flow transmitter Detector: 0.6kg 1.2kg 1.6kg Conditions on straight pipe ( D : Inside diameter of pipe) Upstream side L 5D 10D Detector L 10D or more 90 bend Downstream side L 10D or more Classification : 5kg (FSGS3) (FSGS5) (FSD32) L 10D 50D Tee L 30D L 10D L 30D L 5D D Diffuser 0.5D or more 10D or more 1.5D L 5D Reducer L 10D Various Valve In case that flow control valve exists on upstream side. Stop valve Check valve Pump In case that flow control valve exists on downstream side. L 50D P (Note) The source : JEMIS-032 3 FSH, FSG, FSD MEASUREMENT PRINCIPLE MOUNTING OF DETECTOR Ultrasonic pulses are propagated aslant between the upstream and downstream sensors, detecting the time difference due to flow for measurement. Ultrasonic oscillator Plastic wedge Pipe Upstream sensor t1 Lining Output signal Flow transmitter D t2 Velocity V Downstream sensor CONFIGURATION DIAGRAM (1) 2-path system (V method) (2) 2-path system (Z method) Cable Cable Flow transmitter Detector Detector 4-20mA DC Contact (up to 3 points) Flow transmitter 4-20mA DC Contact (up to 3 points) DETECTOR SELECTION GUIDE Type Fluid Mounting temperature [°C] method FSGS32 Note) FSGS31 V –40 to 80 FSGS51 Note) FSGS50 FSD32 –40 to 200 50 50 100 200 250 300 Px, P, M 400 200 Px, P, M Z 200 Px, P, M V 50 Px, P, M 150 1000 3000 6000 300 V Z Classification of piping materials Inner diameter of piping ø (mm) 13 25 3000 250 Px, P, M 400 Px : PP, PVDF P : Plastic (PVC, etc.) M : Msetallic piping (steel pipe, copper pipe, aluminum, etc.) Note: The ultrasonic signal cannot be transmitted easily when the classification of piping material is Px or the turbidity is high. In such a case, a preliminary check by a portable ultrasonic flowmeter is recommended. 4 6000 CODE SYMBOLS <Detector, submersible type> 1 2 3 4 5 6 7 8 <Flow transmitter> 1 2 3 4 5 6 7 8 9 10 11 12 F SH SYY YA 1 F SGS Description Type (4th digit) Standard E Use (6th digit) Transit time measurement (two path) A Power supply (7th digit) 100 to 240 Vac, 50/60 Hz 20 to 30 Vdc 1 4 Conduit connection (10th digit) G1/2 and G3/8 (female screw) with water-proof connection Y Parameter setting, Tag Plate (12th digit) None With setting With setting and Tag Plate With Tag Plate Y A B C <Detector, high temperature type> 1 2 3 4 5 6 7 8 1 F SD Description Type (4th, 5th and 6th digits) High-temperature sensor *1 (ø50 to ø400), V or Z method 3 2 0 Belt, acoustic coupler (7th digit) *3 For fixed type Y <Detector, common type> 1 2 3 4 5 6 7 8 9 10 11 12 13 F SGS Y Y1 3 3 5 5 1 Acoustic coupler (10th digit) None*4 Silicon rubber (KE348W) Silicone-free grease (HIGH-Z) *5 Silicone grease (G40M)*5 Additional specification (11th digit) None Tag plate Y A B C Y A Y A B C D E 3 3 5 5 1 Description Type (5th and 6th digits) Small sensor 2MHz (ø50 to ø300) V method Small sensor 1MHz (ø50 to ø300)*2 Large sensor 1MHz (ø200 to ø6000) V or Z Large sensor 0.5KHz (ø200 to ø6000)*2 method 2 1 1 0 Dedicated signal cable (9th digit) 10m 20m 30m 40m 50m 60m 70m 80m 90m 100m 110m 120m 130m 140m 150m Specified length (Contact us if length is more than 150m. Max. length is 300m.) Acoustic coupler (10th digit) Silicon rubber (KE348) Silicone grease (G40M) *5 Additional specification (11th digit) None Tag plate B C D E F G H J K L M N P Q R Z A C Y A Y A B C D E Wire rope for mounting (12th digit) Specify it in the case of FSGS41 or FSGS5. None Nominal diameter: up to ø500mm Nominal diameter: up to ø1000mm Nominal diameter: up to ø1500mm Nominal diameter: up to ø3000mm Can be specified Nominal diameter: up to ø6000mm only for FSGS5 Description Type (5th and 6th digits) Small sensor 2MHz (ø50 to ø300) V method Small sensor 1MHz (ø50 to ø300)*2 V or Z Large sensor 1MHz (ø200 to ø6000) Large sensor 0.5KHz (ø200 to ø6000)*2 method 2 1 1 0 9 10 11 12 13 A1 Wire rope for mounting (12th digit) Specify it in the case of FSGS41 or FSGS5. None Nominal diameter: up to ø500mm Nominal diameter: up to ø1000mm Nominal diameter: up to ø1500mm Nominal diameter: up to ø3000mm Can be specified Nominal diameter: up to ø6000mm only for FSGS5 *1: For turbid fluid or old pipe, cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, use an optional guide rail (TK4C6164C1), and carry out mounting by Z method. Applicable diameter range V method: ø50 to ø250 Z method: ø150 to ø400 *2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select FSGS31 or FSGS50. *3: As for the acoustic coupler, grease (KS62M) for high temperatures is attached. *4: Silicone rubber (KE-348W) is provided as a standard accessory to fill the wiring mold. (It can also be used as an acoustic coupler.) If an additional acoustic coupler is required, select one among A, B and C. *5: Normally select silicone rubber as acoustic coupler. Siliconerubber in tube (100g) is furnished. If you place an order for several units, 1 tube may suffice for every 2 units. Select silicone-free grease for semiconductor anufacturing equipment or the like that is vulnerable to silicone. The silicone-free grease is water-soluble and, therefore, cannot be used in environment exposed to water or on piping subjected to a condensation. Since the grease does not set, a periodic maintenance (cleaning, refilling every about 6 months at normal temperature) is necessary. 5 FSH, FSG, FSD <Signal cable> Note: Must be procured unless the sensor is a submersible type. • For detector FSG and FSD 1 2 3 4 5 6 7 8 1 F L Y Description Type of sensor (4th digit) Small and large sensor (for FSG) Hight temp sensor (for FSD) 8 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Z 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 1 2 3 4 5 Z 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 0 0 0 0 0 Z Cable length (5,6 and 7th digit) 5m 10 m 15 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 100 m 110 m 120 m 130 m 140 m 150 m Others (contact us) Note: Preapare a detector and dedicated signal cable (2 set). Loader software for PCs Equipped as standard • Works on PC/AT compatible machines. • Operation on PC98-series machines (NEC) cannot be guaranteed. • Operation on self-made PCs or shop-brand PCs cannot be guaranteed. • Major functions: Setting/changing of various parameters for the main unit • O/S: Windows2000/XP • Memory requirement: 128MB or more • Disk unit: Windows2000/XP-compatible CD-ROM drive • Hard disk drive capacity: Free space of 52MB or more Note: PC loader communication cable (type ZZP*TK4H6253, Specifications: D-sub 9 pin receptacle, cable length 3m) is separately required. 6 SCOPE OF DELIVERY ITEMS DESIGNATED ORDERING •Flow transmitter (Type: FSH): F low transmitter CD-ROM (Instruction manual, Loader software) •Detector (Type: FSG, FSD): S ensor unit, Mounting belt, Silicon compound •Signal cable (Type: FLY): Cable (2 wires) 1.Detector code symbols 2.Flow transmitter code symbols 3.Signal cable code symbols 4.For large sensor: Mounting pipe size 5.Tag No. as necessary 6.If parameter setting is specified, send back the attached parameter specification table duly filled. OUTLINE DIAGRAM (Unit:mm) <Flow transmitter (type: FSH)> 4-Ø 9 (273) 240 332 352 30 Mtg. plate Duosonics 72 134 14 233 33 33 3 5-G3/8 Female screw 30 30 30 48 48 4-G1/2 Female screw 24 48 CONNECTION DIAGRAM Power supply terminals (AC) 1 2 3 4 L N 1 B 2 B 3 A 4 100 to 240V AC 50/60Hz – 2 GND UP STR 3 HF 4 GND DOWN STR LINE1 7 5 HF 8 + – 9 Iout SERIAL 20 to 30V DC 1 HF 6 SERIAL Power supply terminals (DC) 4 1 2 3 + 5 6 GND UP STR 7 HF 8 GND DOWN STR LINE2 1 2 + – DO1 No. RS485 RS232C 4 5 6 TRX2 (–) TRX1 (+) SHILD TXD RXD COM 3 + DO2 Open collector 4 – 5 + 6 – Communication cable (option) Cap (red) Cap (yellow) Cap (black) 7 DO3 Relay contact 7 FSH, FSG, FSD OUTLINE DIAGRAM (Unit:mm) Connector Scale(inch) Saddle Scale(mm) 530±2 Distance between two sensors 0 to 330 Name plate Lock nut Element holder Cursor φ26 33±0.5 90max. 205max. 44±1 Detector FSD32 (High-temperature sensor) 5 Frame Sensor 410±2 400 5 Sensor 410±2 400 5 5 P P Name plate Name plate 47 Spacing : 0 to 270mm 47 Spacing : 0 to 270mm 50±1 33 Chain 50±1 33 46±1 Mounting spring Chain 46±1 Mounting spring (10) (10) Frame guide VIEW FROM P (Common type) VIEW FROM P Frame guide (Submersible type) Detector FSGS3 (Small sensor) Name plate 84±1 84±1 Name plate 114 114 78±1 Sensor Wire rope 78±1 Sensor Mounting spring L(cable length (m) : specified by order) Wire rope ø19 Ø19 67±1 67±1 Mounting spring (Common type) (Submersible type) Detector FSGS5 (Large sensor) 8 L(cable length (m) : specified by order) Frame Signal cable : FLY8 (For FSG) 8 3-ø4.3 L(cable length (m) : specified by order) ø11 30 To Detector ø7.3 To Flow transmitter 3-ø3.7 L : By specification when ordered. 5.5 Signal cable : FLY9 (For FSD) Loader cable : ZZP*TK4H6253 34 Connector ø14.5 46 BNC connector 67 30 To Personal computer ø7.3 To Detector 3.2±0.2 (m) L(cable length (m) : specified by order) ø11 To Flow transmitter 3-ø3.7 5.5 L : By specification when ordered. ø6.9 To Flow transmitter Terminal cap (Red) 3ø3 .7 Terminal cap (Yellow) Terminal cap (Black) 6.6 Red Yellow Black TXD RXD COM RS-232C 9 FSH, FSG, FSD <Parameter specification table> No. Setting item Settable range Initial value 1 Outer diameter 10.00 to 6200.00mm (0.393 to 244.100 inch) 60.00mm (2.362 inch) 2 Pipe material 12 menus PVC 3 4 5 6 PiPing specification Pipe S.V. : 1000 to 3700m/s (3280 to 12140 ft/s) Wall thickness 0.10 to 100.00mm (0.003 to 3.940 inch) 4.00mm (0.157 inch) Lining material 8 menus No lining Lining S.V. : 1000 to 3700m/s (3280 to 12140 ft/s) Lining thickness 0.01 to 100.00mm (0.000 to 3.940 inch) Kind of Fluid 17 menus [mm, inch] Carbon steel, Stainless steel, PVC, Copper, Castiron, Aluminum, FRP, Ductileiron, PEEK, PVDF, Acrylic Others (Sound velocity : [m/s, ft/s]) [mm, inch] No lining, Tar epoxy, Mortar, Rubber, Teflon, Pyrex glass, PVC, Others (Sound velocity : [m/s, ft/s]) [mm, inch] Water Water, Seawater, DIST. water, Ammonia, Alcohol, Benzene, Bromide, Ethanol, Glycol, Kerosene, Milk, Methanol, Toluol, Lube oil, Fuel oil, Petrol, Others (Sound velocity : [m/s, ft/s]) (Kinematic viscosity [x10-6m2/s, ft2/s]) Fluid S.V. : 500 to 2500m/s (1641 to 8203 ft/s) Kinematic viscosity : 0.001 to 999.9999 x 10-6m2/s (0.0107 to 10763.9088 x 10-6ft2/s) Range unit 19 menus m/s (ft/s) m/s, L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s, m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s, BBL/min, BBL/h, BBL/d, KBBL/d, MBBL/d, (ft/s, ft3/s, ft3/min, ft3/h, ft3/d, kft3/d, Mft3/d, gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d, BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d) 8 Range type 4 menus Single Single, Auto 2, Bi-dir, Bi-dir Auto 2 9 Full scale or Full scale 1 In terms of flow velocity 0.00 ··· 0.30 to 32.00m/s (0.98 to 104.98 ft/s) 2.00m/s (6.56 ft/s) [ ] Full scale 2 In terms of flow velocity 0.00 ··· 0.30 to 32.00m/s (0.98 to 104.98 ft/s) 4.00m/s (13.12 ft/s) [ ] Range HYS. 0.00 to 20.0% 10.00% % 12 Output limit LO. -20 to 0% -20% % 13 Output limit HI. 100 to 120% 120% % 14 Output burnout 5 menus Hold 15 Burnout timer 0 to 900sec 10sec 16 Rate limit 0.00 to 5.00m/s (0.00 to 16.40 ft/s) in terms of flow velocity 0.00m/s (0.00 ft/s) 17 Rate limit timer 0 to 900sec 0sec sec 0.0 to 100.0sec 5.0sec sec 1 : Display kind 7 menus Flowrate (m3/s) 2 : Display kind 7 menus Flow velocity (m/s) Flow velocity, Flowrate, Total forward, Total reverse, F : Total pulse, R : Total pulse, Flow rate (%) 0.00 to 5.00m/s (0.00 to 16.40 ft/s) in terms of flow velocity 0.01m/s (0.03 ft/s) 18 19 20 21 Damping Display setting 11 Output setting 7 10 10 Settable value Low flow cut Not use, Hold, Upper, Lower, Zero sec [ ] Flow velocity, Flowrate, Total forward, Total reverse, F : Total pulse, R : Total pulse, Flow rate (%) [ ] No. Setting item Settable range Initial value Settable value Total mode 3 menus Total stop Total stop, Total run, Total reset 23 Total unit 8 menus mL mL, L, m3, km3, Mm3, mBBL, BBL, kBBL, ft3, kft3, Mft3, kgal, gal, mBBL, BBL, kBBL, ACRF 24 Total rate 0.000 to 999999.999 0.000 [ ] 25 F : Total preset 0.000 to 9999999999.999 0.000 [ ] 26 F : Total SW 0.000 to 9999999999.999 0.000 [ ] R : Total preset 0.000 to 9999999999.999 0.000 [ ] 28 R : Total SW 0.000 to 9999999999.999 0.000 [ ] 29 Output burnout 2 menus Hold 30 Burnout timer 0 to 900sec 10sec 31 Pulse width 1 3 menus 50ms 50, 100, 200 32 Pulse width 2 9 menus 50ms 0.5, 1.0, 2.0, 5.0, 10.0, 20.0, 50.0, 100.0, 200.0 33 Flow sw high In terms of flow velocity 0.00 to 32.00m/s (0.00 to 104.98 ft/s) 0.00m/s [ ] Flow sw low In terms of flow velocity 0.00 to 32.00m/s (0.00 to 104.98 ft/s) 4.00m/s [ ] 35 Flow sw HYS. 0 to 20% 10% 36 Output DO1 15 menus Not use Not use, Signal error, F : Total pulse, R : Total pulse, F : Total alarm, R : Total alarm, F : Total overflow, R : Total overflow, Flow SW high, Flow SW Low, Full scale2, AO range over, Pulse range over, R : Flow direction, Device error 37 Mode DO1 2 menus Normal Normal, Reverse 38 Output DO2 15 menus Not use Not use, Signal error, F : Total pulse, R : Total pulse, F : Total alarm, R : Total alarm, F : Total overflow, R : Total overflow, Flow SW high, Flow SW Low, Full scale2, AO range over, Pulse range over, R : Flow direction, Device error 39 Mode DO2 2 menus Normal Normal, Reverse 40 Output DO3 15 menus Not use Not use, Signal error, F : Total pulse, R : Total pulse, F : Total alarm, R : Total alarm, F : Total overflow, R : Total overflow, Flow SW high, Flow SW Low, Full scale2, AO range over, Pulse range over, R : Flow direction, Device error 41 Mode DO3 2 menus Normal Normal, Reverse Status output 34 Flow switch 27 Total 22 Not use, Hold sec % 11 FSH, FSG, FSD No. Setting item Settable range Initial value Settable value 42 System unit 2 menus Metric Metric, English 43 Language 5 menus English Japanese, English, German, French, spanish COM. speed 3 menus 38400BPS 9600BPS, 19200BPS, 38400BPS COM. parity 3 menus None None, Even, Odd COM. stop bit 2 menus 1 bit 1 bit, 2bits Serial method 2 menus RS232C RS232C, RS485 Station No. 31 menus 1 1 to 31 Measurement mode 2 menus 1 Path (2 path) AO Definition 3 menus Line 1 (Average) Note2 Average, Line 1, Line 2 4 menus FSW12 (FLW51/FSG51) Note2 FSW12, FSW21, FSW40, FSW50, FLW11/FSG31, FLW41/FSG41, FLW12/FSG32, FLD12/FSD12, FLD22/FSD22, FLW32/FSD32, FLS50/FSG50, FLW51/FSG51 46 47 System 45 Serial com. 44 49 50 51 Measuremant mode 48 Sensor Type 2 Path Note2 Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1 and 2 shown below are satisfies. Condition 1 : Condition 2 : Flow span-1*[m3/s] total pulse value*[m3] 1000 [In the case of DO1 and DO2] 1 [In the case of DO3] Flow span-1*[m3/s] 1000 total pulse value*[m3] 2 × total pulse width [ms] * In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater. Note2: Settable value at the time of shipment. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan