MEANWELL SP-75-7.5

SP-75
75W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.93
Protections: Short circuit / Overload / Over voltage
Built-in constant current limiting circuit
Low profile: 33mm thickness
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
SP-75-3.3
SP-75-5
SP-75-7.5
SP-75-12
SP-75-13.5
SP-75-15
SP-75-24
SP-75-27
SP-75-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
15A
15A
10A
6.3A
5.6A
5A
3.2A
2.8A
1.6A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 10A
0 ~ 6.3A
0 ~ 5.6A
0 ~ 5A
0 ~ 3.2A
0 ~ 2.8A
0 ~ 1.6A
RATED POWER
49.5W
75W
75W
75.6W
75.6W
75W
76.8W
75.6W
76.8W
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
100mVp-p
100mVp-p
100mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
OUTPUT
3.14 ~ 3.63V 4.75 ~ 5.5V
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
600ms, 60ms at full load
36ms at full load
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
Note.5 85 ~ 264VAC
120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC
EFFICIENCY (Typ.)
68%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.3A/115VAC
0.7A/230VAC
COLD START 30A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
0.96/115VAC at full load
72%
74%
77%
78%
79%
80%
80%
80%
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
3.8 ~ 4.46V 5.75 ~ 6.75V 8.63 ~ 10.13V 13.8 ~ 16.2V 15.53 ~ 18.23V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION REMOTE CONTROL(OPTION) CN3:4 ~ 10VDC POWER OFF, <0 ~ 0.8VDC POWER ON
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
OVERLOAD
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
(Note 4)
OTHERS
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
Compliance to EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
20 ~ 90% RH non-condensing
/ 70% RH
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
208.8K hrs min. MIL-HDBK-217F (25 )
179*97*33mm (L*W*H)
0.58Kg; 20pcs/12Kg/0.64CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SP-75-SPEC 2010-10-18
SP-75
75W Single Output with PFC Function
Mechanical Specification
Case No. 920A
60
series
Unit:mm
65
1
2
CN3
ADJ.
LED
2-M4 L=4mm
4
49.5
9.5
3
119
99
8
1
2
5
Terminal Pin No. Assignment
16
Pin No.
1
2
3
15
117
Pin No.
1
2
32.5
17
18
33
25
Assignment
AC/N
AC/L
Remote ON/OFF(CN3): Molex 5046-02 or equivalent(optional)
8
11 max.
Pin No.
4
5
Assignment
DC OUTPUT +V
DC OUTPUT -V
FG
Assignment
RCRC+
Mating Housing
Terminal
Molex 5051
or equivalent
Molex 2759
or equivalent
6-M4 L=6mm
179
Block Diagram
PFC fosc : 67KHz
PWM fosc : 134KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
FG
O.L.P.
+V
-V
CONSTANT
CURRENT
LIMITING &
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
(For 3.3V,5V,7.5V type)
100
(1)
With 18CFM
Forced AIR
100
90
80
80
70
(1)For 12V output or above
LOAD (%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
85
100
115
135
155
230
264
INPUT VOLTAGE (VAC) 60Hz
File Name:SP-75-SPEC 2010-10-18