VOLGEN SPU24-103

SPU24 SERIES
24W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU24 series of AC/DC switching mode power
supplies provide 24 Watts of continuous output power. All
supplies are UL 94V-0 compliant, include IEC-320-C14 input
for worldwide applications. All models meet FCC class B and
CISPR class B emission Limits and are designed to comply
with UL, C-UL, TUV and CE requirements. All units are 100%
burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 5VDC Thru 48VDC
Optional Output Connector (See appendix)
Single Output
Splash proof
Class I Insulation
Two years warranty
Safety Approvals:
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
Vin
Input Voltage
90
264
VAC
Fin
Input Frequency
47
63
Hz
Wo
Output Power Range
0
24
W
Vo
Output Voltage Range
See rating chart
V
Io
Output Current Range
See rating chart
A
Iil
Input Current (Low Line)
Io=Full load, Vin=115VAC
Iih
Input Current (High Line)
Io=Full load, Vin=230 VAC
Irl
Low Line Inrush Current
Irh
High Line Inrush Current
Eff
Efficiency
Io=Full load, 25°c ,Cool start,
Vin=115VAC
Io=Full load, 25°c, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
Vin=90 to 264VAC
REG-i Line Regulation
Io=Full Load
REG-o Load Regulation
Vin=230VAC
65
0.7
A
0.46
A
12
15
A
26
30
A
75
85
%
0.5
1
%
3
5
%
OVP
Over Voltage Protection
OCP
Over Current Protection
Nil.But,Output protected to short circut conditions
%
Ttr
Transient Response
Io=Full Load to Half Load, Vin=100VAC
mS
Thold Hold-Up Time
Optional
4
Io=Full Load, Vin=100VAC
12
Ts
Start Up Time
Io=Full Load, Vin=100VAC
0.3
mS
Vrn
Ripple & Noise (Pe ak to Peak)
Full Load, Vin=90VAC
0.5
1
%
Ilk
Safety Ground Leakage Curr ent
Io=Full Load, Vin=240VAC
0.5
0.75
mA
Tc
Temperature Coefficient
All output
0.04
%/°c
Max.
Unit
1
-0.04
2
S
Environmental :
Sym.
Parameter
Toper
Operating Temperature
Tstg
Storage Temperature
Test Conditions
Hr
Relative Humidity
Pd
Derate linearly from 100% load at 40°c to 50% load at 70°c
Min.
Typ.
0
70
°c
-40
85
°c
5
95
%
SPU24 SERIES
24W Desk Top Switching Power Supplies For I.T.E.
Safety Specifications:
Sym.
Vps
Vpg
Ri
Parameter
Test Conditions
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding
Voltagefor Primary to ground
Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC
EMI requirements for FCC
PART-15
Min. Typ. Max.
Unit
Primary to secondary
4242
VDC
Primary to ground
2121
VDC
Test Voltage = 500VDC
50
MW
Vin=220VAC
B
CLASS
Vin=110VAC
B
CLASS
Output Voltage And Current Rating Chart ( Single Output ) :
Model Number
Output Voltage
Output Current
Total Regulation
Maximum
Output Power
SPU24-102
05 ~ 06 VDC
3.00 ~ 2.50 A
5%
15W
SPU24-103
06 ~ 08 VDC
3.30 ~ 2.50 A
5%
20W
SPU24-104
08 ~ 11 VDC
2.75 ~ 2.00 A
5%
22W
SPU24-105
11 ~ 13 VDC
2.18 ~ 1.85 A
5%
24W
SPU24-106
13 ~ 16 VDC
1.85 ~ 1.50 A
5%
24W
SPU24-107
16 ~ 21 VDC
1.50 ~ 1.14 A
5%
24W
SPU24-108
21 ~ 27 VDC
1.14 ~ 0.89 A
3%
24W
SPU24-109
27 ~ 33 VDC
0.89 ~ 0.73 A
3%
24W
SPU24-110
33 ~ 40 VDC
0.73 ~ 0.60 A
3%
24W
SPU24-111
48 VDC
0.50 A
2%
24W
Mechanical Specifications :
Note:
1. Dimensions are shown in mm.
2. Weight: 215gs approx.
3. Optional output connector:
See page Appendix.