WINBOND W9825G2JB

W9825G2JB
2M  4 BANKS  32BITS SDRAM
Table of Contents1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
GENERAL DESCRIPTION ............................................................................................................. 3
FEATURES .................................................................................................................................... 3
AVAILABLE PART NUMBER ......................................................................................................... 3
BALL CONFIGURATION ............................................................................................................... 4
BALL DESCRIPTIONS ................................................................................................................... 5
BLOCK DIAGRAM.......................................................................................................................... 6
FUNCTIONAL DESCRIPTION ....................................................................................................... 7
7.1
Power Up and Initialization .................................................................................................. 7
7.2
Programming Mode Register............................................................................................... 7
7.3
Bank Activate Command ..................................................................................................... 7
7.4
Read and Write Access Modes ........................................................................................... 7
7.5
Burst Read Command ......................................................................................................... 8
7.6
Burst Write Command ......................................................................................................... 8
7.7
Read Interrupted by a Read ................................................................................................ 8
7.8
Read Interrupted by a Write ................................................................................................ 8
7.9
Write Interrupted by a Write................................................................................................. 8
7.10 Write Interrupted by a Read ................................................................................................ 8
7.11 Burst Stop Command .......................................................................................................... 9
7.12 Addressing Sequence of Sequential Mode ......................................................................... 9
7.13 Addressing Sequence of Interleave Mode .......................................................................... 9
7.14 Auto-precharge Command ................................................................................................ 10
7.15 Precharge Command ........................................................................................................ 10
7.16 Self Refresh Command ..................................................................................................... 10
7.17 Power-down Mode ............................................................................................................. 11
7.18 No Operation Command .................................................................................................... 11
7.19 Deselect Command ........................................................................................................... 11
7.20 Clock Suspend Mode ........................................................................................................ 11
OPERATION MODE..................................................................................................................... 12
ELECTRICAL CHARACTERISTICS ............................................................................................ 13
9.1
Absolute Maximum Ratings ............................................................................................... 13
9.2
Recommended DC Operating Conditions ......................................................................... 13
9.3
Capacitance ....................................................................................................................... 13
9.4
DC Characteristics ............................................................................................................. 14
9.5
AC Characteristics and Operating Condition ..................................................................... 15
TIMING WAVEFORMS ................................................................................................................ 17
10.1 Command Input Timing ..................................................................................................... 17
10.2 Read Timing ...................................................................................................................... 18
-1-
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.
12.
13.
10.3 Control Timing of Input/Output Data .................................................................................. 19
10.4 Mode Register Set Cycle ................................................................................................... 20
OPERATING TIMING EXAMPLE................................................................................................. 21
11.1 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3) ........................................... 21
11.2 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3, Auto-precharge) ................ 22
11.3 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3) ........................................... 23
11.4 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3, Auto-precharge) ................ 24
11.5 Interleaved Bank Write (Burst Length = 8) ........................................................................ 25
11.6 Interleaved Bank Write (Burst Length = 8, Auto-precharge) ............................................. 26
11.7 Page Mode Read (Burst Length = 4, CAS Latency = 3) ................................................... 27
11.8 Page Mode Read / Write (Burst Length = 8, CAS Latency = 3) ........................................ 28
11.9 Auto-precharge Read (Burst Length = 4, CAS Latency = 3) ............................................. 29
11.10 Auto-precharge Write (Burst Length = 4) .......................................................................... 30
11.11 Auto Refresh Cycle ............................................................................................................ 31
11.12 Self Refresh Cycle ............................................................................................................. 32
11.13 Burst Read and Single Write (Burst Length = 4, CAS Latency = 3) .................................. 33
11.14 Auto-precharge Timing (Read Cycle) ................................................................................ 34
11.15 Auto-precharge Timing (Write Cycle) ................................................................................ 35
11.16 Timing Chart of Read to Write Cycle ................................................................................. 36
11.17 Timing Chart of Write to Read Cycle ................................................................................. 36
11.18 Timing Chart of Burst Stop Cycle (Burst Stop Command) ................................................ 37
11.19 Timing Chart of Burst Stop Cycle (Precharge Command) ................................................ 37
11.20 CKE/DQM Input Timing (Write Cycle) ............................................................................... 38
11.21 CKE/DQM Input Timing (Read Cycle) ............................................................................... 39
PACKAGE SPECIFICATION ....................................................................................................... 40
REVISION HISTORY ................................................................................................................... 41
-2-
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
1. GENERAL DESCRIPTION
W9825G2JB is a high-speed synchronous dynamic random access memory (SDRAM), organized as
2,097,152 words  4 banks  32 bits. W9825G2JB delivers a data bandwidth of up to 166M words per
second. For different application, W9825G2JB is sorted into two speed grades: -6, -75. The -6/-6I is
compliant to the 166MHz/CL3 specification, (the -6I grade which is guaranteed to support -40°C ~
85°C) ,the -75/75I is compliant to the PC133/CL3 specification (the 75I grade which is guaranteed to
support -40°C ~ 85°C).
Accesses to the SDRAM are burst oriented. Consecutive memory location in one page can be
accessed at a burst length of 1, 2, 4, 8 or full page when a bank and row is selected by an ACTIVE
command. Column addresses are automatically generated by the SDRAM internal counter in burst
operation. Random column read is also possible by providing its address at each clock cycle. The
multiple bank nature enables interleaving among internal banks to hide the precharging time.
By having a programmable Mode Register, the system can change burst length, latency cycle,
interleave or sequential burst to maximize its performance. W9825G2JB is ideal for main memory in
high performance applications.
2. FEATURES














3.3V  0.3V for -6 speed grades power supply
2.7V~3.6V for -6I/-75/75I speed grades power supply
Up to 166 MHz Clock Frequency
2,097,152 Words  4 banks  32 bits organization
Self Refresh Mode: Standard and Low Power
CAS Latency: 2 and 3
Burst Length: 1, 2, 4, 8 and full page
Burst Read, Single Writes Mode
Byte Data Controlled by DQM
Auto-precharge and Controlled Precharge
4K Refresh cycles / 64 mS
Interface: LVTTL
Package: 90 Balls TFBGA, using Lead free materials with RoHS compliant
Dual-Die package
3. AVAILABLE PART NUMBER
PART NUMBER
SELF REFRESH
CURRENT (MAX)
SPEED GRADE
OPERATING
TEMPERATURE
W9825G2JB-6
166MHz/CL3
4 mA
0°C ~ 70°C
W9825G2JB-6I
166MHz/CL3
4 mA
-40°C ~ 85°C
W9825G2JB-75
133MHz/CL3
4 mA
0°C ~ 70°C
W9825G2JB75I
133MHz/CL3
4 mA
-40°C ~ 85°C
- 3 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
4. BALL CONFIGURATION
Top View
1
2
3
4
5
6
7
8
9
A
DQ26
DQ24
VSS
VDD
DQ23
DQ21
DQ28
VDDQ
VSSQ
VDDQ
VSSQ
DQ19
VSSQ
DQ27
DQ25
DQ22
DQ20
VDDQ
VSSQ
DQ29
DQ30
DQ17
DQ18
VDDQ
VDDQ
DQ31
NC
NC
DQ16
VSSQ
VSS
DQM3
A3
A2
DQM2
VDD
A4
A5
A6
A10
A0
A1
A7
A8
NC
NC
BS1
A11
CKE
A9
BS0
CS#
RAS#
DQM1
NC
NC
CAS#
WE#
DQM0
VDDQ
DQ8
VSS
VDD
DQ7
VSSQ
VSSQ
DQ10
DQ9
DQ6
DQ5
VDDQ
VSSQ
DQ12
DQ14
DQ1
DQ3
VDDQ
DQ11
VDDQ
VSSQ
VDDQ
VSSQ
DQ4
DQ13
DQ15
VSS
VDD
DQ0
DQ2
B
C
D
E
F
G
H
J
CLK
K
L
M
N
P
R
-4-
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
5. BALL DESCRIPTIONS
BALL LOCATION PIN NAME
FUNCTION
DESCRIPTION
G8,G9,F7,F3,G1,G2,
G3,H1,H2,J3,G7,H9
A0A11
Address
Multiplexed pins for row and column address. Row
address: A0A11. Column address: A0A8. A10 is
sampled during a precharge command to determine if all
banks are to be precharged or bank selected by BS0,
BS1.
J7,H8
BS0, BS1
Bank Select
Select bank to activate during row address latch time, or
bank to read/write during address latch time.
Data Input/
Output
Multiplexed pins for data output and input.
CS
Chip Select
Disable or enable the command decoder. When command
decoder is disabled, new command is ignored and
previous operation continues.
J9
RAS
Row Address
Strobe
K7
CAS
K8
WE
A1,A2,A8,A9,B1,B9,
C2,C3,C7,C8,D2,D3,
D7,D8,E2,E8,L2,L8,
DQ0DQ31
M2,M3,M7,M8,N2,N3
,N7,N8,P1,P9,R1,R2,
R8,R9
J8
Command input. When sampled at the rising edge of the
clock RAS , CAS and WE define the operation to be
executed.
Column Address
Referred to RAS
Strobe
Write Enable
Referred to RAS
The output buffer is placed at Hi-Z (with latency of 2) when
DQM is sampled high in read cycle. In write cycle,
Input/output mask
sampling DQM high will block the write operation with zero
latency.
F2,F8,K1,K9
DQM03
J1
CLK
Clock Inputs
System clock used to sample inputs on the rising edge of
clock.
J2
CKE
Clock Enable
CKE controls the clock activation and deactivation. When
CKE is low, Power-down mode, Suspend mode, or Self
Refresh mode is entered.
A7,F9,L7,R7
VDD
Power
Power for input buffers and logic circuit inside DRAM.
A3,F1,L3,R3
VSS
Ground
Ground for input buffers and logic circuit inside DRAM.
B2,B7,C9,D9,E1,L1,
M9,N9,P2,P7
VDDQ
Power for I/O
buffer
Separated power from VDD, to improve DQ noise
immunity.
B8,B3,C1,D1,E9,L9,
M1,N1,P3,P8,
VSSQ
Ground for I/O
buffer
Separated ground from VSS, to improve DQ noise
immunity.
E3,E7,H3,H7,K2,K3
NC
No Connection
No connection.
- 5 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
6. BLOCK DIAGRAM
CLK
CLOCK
BUFFER
CKE
CONTROL
SIGNAL
GENERATOR
CS
RAS
COMMAND
DECODER
WE
ROW DECODER
COLUMN DECODER
A10
MODE
REGISTER
A0
COLUMN DECODER
ROW DECODER
CAS
CELL ARRAY
BANK #0
CELL ARRAY
BANK #1
SENSE AMPLIFIER
SENSE AMPLIFIER
ADDRESS
BUFFER
A9
A11
BS0
BS1
DQ
BUFFER
DATA CONTROL
CIRCUIT
COLUMN
COUNTER
DQM0 - 3
COLUMN DECODER
ROW DECODER
COLUMN DECODER
ROW DECODER
REFRESH
COUNTER
DQ0 - 31
CELL ARRAY
BANK #2
SENSE AMPLIFIER
CELL ARRAY
BANK #3
SENSE AMPLIFIER
Note: The cell array configuration is 4049 * 512 * 32
-6-
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
7. FUNCTIONAL DESCRIPTION
7.1 Power Up and Initialization
The default power up state of the mode register is unspecified. The following power up and
initialization sequence need to be followed to guarantee the device being preconditioned to each user
specific needs.
During power up, all VDD and VDDQ pins must be ramp up simultaneously to the specified voltage
when the input signals are held in the “NOP” state. The power up voltage must not exceed V DD +0.3V
on any of the input pins or VDD supplies. After power up, an initial pause of 200 µS is required followed
by a precharge of all banks using the precharge command. To prevent data contention on the DQ bus
during power up, it is required that the DQM and CKE pins be held high during the initial pause period.
Once all banks have been precharged, the Mode Register Set Command must be issued to initialize
the Mode Register. An additional eight Auto Refresh cycles (CBR) are also required before or after
programming the Mode Register to ensure proper subsequent operation.
7.2
Programming Mode Register
After initial power up, the Mode Register Set Command must be issued for proper device operation.
All banks must be in a precharged state and CKE must be high at least one cycle before the Mode
Register Set Command can be issued. The Mode Register Set Command is activated by the low
signals of RAS , CAS , CS and WE at the positive edge of the clock. The address input data
during this cycle defines the parameters to be set as shown in the Mode Register Operation table. A
new command may be issued following the mode register set command once a delay equal to tRSC
has elapsed. Please refer to the next page for Mode Register Set Cycle and Operation Table.
7.3
Bank Activate Command
The Bank Activate command must be applied before any Read or Write operation can be executed.
The operation is similar to RAS activate in EDO DRAM. The delay from when the Bank Activate
command is applied to when the first read or write operation can begin must not be less than the RAS
to CAS delay time (tRCD). Once a bank has been activated it must be precharged before another Bank
Activate command can be issued to the same bank. The minimum time interval between successive
Bank Activate commands to the same bank is determined by the RAS cycle time of the device (t RC).
The minimum time interval between interleaved Bank Activate commands (Bank A to Bank B and vice
versa) is the Bank to Bank delay time (tRRD). The maximum time that each bank can be held active is
specified as tRAS (max).
7.4
Read and Write Access Modes
After a bank has been activated, a read or write cycle can be followed. This is accomplished by setting
RAS high and CAS low at the clock rising edge after minimum of tRCD delay. WE pin voltage level
defines whether the access cycle is a read operation ( WE high), or a write operation ( WE low). The
address inputs determine the starting column address.
Reading or writing to a different row within an activated bank requires the bank be precharged and a
new Bank Activate command be issued. When more than one bank is activated, interleaved bank
Read or Write operations are possible. By using the programmed burst length and alternating the
access and precharge operations between multiple banks, seamless data access operation among
many different pages can be realized. Read or Write Commands can also be issued to the same bank
or between active banks on every clock cycle.
- 7 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
7.5
Burst Read Command
The Burst Read command is initiated by applying logic low level to CS and CAS while holding
RAS and WE high at the rising edge of the clock. The address inputs determine the starting column
address for the burst. The Mode Register sets type of burst (sequential or interleave) and the burst
length (1, 2, 4, 8, full page) during the Mode Register Set Up cycle. Table 2 and 3 in the next page
explain the address sequence of interleave mode and sequential mode.
7.6
Burst Write Command
The Burst Write command is initiated by applying logic low level to CS , CAS and WE while
holding RAS high at the rising edge of the clock. The address inputs determine the starting column
address. Data for the first burst write cycle must be applied on the DQ pins on the same clock cycle
that the Write Command is issued. The remaining data inputs must be supplied on each subsequent
rising clock edge until the burst length is completed. Data supplied to the DQ pins after burst finishes
will be ignored.
7.7
Read Interrupted by a Read
A Burst Read may be interrupted by another Read Command. When the previous burst is interrupted,
the remaining addresses are overridden by the new read address with the full burst length. The data
from the first Read Command continues to appear on the outputs until the CAS Latency from the
interrupting Read Command the is satisfied.
7.8
Read Interrupted by a Write
To interrupt a burst read with a Write Command, DQM may be needed to place the DQs (output
drivers) in a high impedance state to avoid data contention on the DQ bus. If a Read Command will
issue data on the first and second clocks cycles of the write operation, DQM is needed to insure the
DQs are tri-stated. After that point the Write Command will have control of the DQ bus and DQM
masking is no longer needed.
7.9
Write Interrupted by a Write
A burst write may be interrupted before completion of the burst by another Write Command. When the
previous burst is interrupted, the remaining addresses are overridden by the new address and data
will be written into the device until the programmed burst length is satisfied.
7.10 Write Interrupted by a Read
A Read Command will interrupt a burst write operation on the same clock cycle that the Read
Command is activated. The DQs must be in the high impedance state at least one cycle before the
new read data appears on the outputs to avoid data contention. When the Read Command is
activated, any residual data from the burst write cycle will be ignored.
-8-
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
7.11 Burst Stop Command
A Burst Stop Command may be used to terminate the existing burst operation but leave the bank open
for future Read or Write Commands to the same page of the active bank, if the burst length is full page.
Use of the Burst Stop Command during other burst length operations is illegal. The Burst Stop
Command is defined by having RAS and CAS high with CS and WE low at the rising edge of
the clock. The data DQs go to a high impedance state after a delay which is equal to the CAS Latency
in a burst read cycle interrupted by Burst Stop.
7.12 Addressing Sequence of Sequential Mode
A column access is performed by increasing the address from the column address which is input to
the device. The disturb address is varied by the Burst Length as shown in Table 2.
Table 2 Address Sequence of Sequential Mode
DATA
ACCESS ADDRESS
BURST LENGTH
Data 0
n
BL = 2 (disturb address is A0)
Data 1
n+1
No address carry from A0 to A1
Data 2
n+2
BL = 4 (disturb addresses are A0 and A1)
Data 3
n+3
No address carry from A1 to A2
Data 4
n+4
Data 5
n+5
BL = 8 (disturb addresses are A0, A1 and A2)
Data 6
n+6
No address carry from A2 to A3
Data 7
n+7
7.13 Addressing Sequence of Interleave Mode
A column access is started in the input column address and is performed by inverting the address bit
in the sequence shown in Table 3.
Table 3 Address Sequence of Interleave Mode
DATA
ACCESS ADDRESS
Data 0
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 1
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 2
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 3
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 4
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 5
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 6
A8 A7 A6 A5 A4 A3 A2 A1 A0
Data 7
A8 A7 A6 A5 A4 A3 A2 A1 A0
- 9 -
BURST LENGTH
BL = 2
BL = 4
BL = 8
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
7.14 Auto-precharge Command
If A10 is set to high when the Read or Write Command is issued, then the Auto-precharge function is
entered. During Auto-precharge, a Read Command will execute as normal with the exception that the
active bank will begin to precharge automatically before all burst read cycles have been completed.
Regardless of burst length, it will begin a certain number of clocks prior to the end of the scheduled
burst cycle. The number of clocks is determined by CAS Latency.
A Read or Write Command with Auto-precharge can not be interrupted before the entire burst
operation is completed. Therefore, use of a Read, Write or Precharge Command is prohibited during a
read or write cycle with Auto-precharge. Once the precharge operation has started, the bank cannot
be reactivated until the Precharge time (tRP) has been satisfied. Issue of Auto-precharge command is
illegal if the burst is set to full page length. If A10 is high when a Write Command is issued, the Write
with Auto-precharge function is initiated. The SDRAM automatically enters the precharge operation
two clocks delay from the last burst write cycle. This delay is referred to as Write tWR. The bank
undergoing Auto-precharge can not be reactivated until tWR and tRP are satisfied. This is referred to as
tDAL, Data-in to Active delay (tDAL = tWR + tRP). When using the Auto-precharge Command, the interval
between the Bank Activate Command and the beginning of the internal precharge operation must
satisfy tRAS (min).
7.15 Precharge Command
The Precharge Command is used to precharge or close a bank that has been activated. The
Precharge Command is entered when CS , RAS and WE are low and CAS is high at the rising
edge of the clock. The Precharge Command can be used to precharge each bank separately or all
banks simultaneously. Three address bits, A10, BS0, and BS1, are used to define which bank(s) is to
be precharged when the command is issued. After the Precharge Command is issued, the precharged
bank must be reactivated before a new read or write access can be executed. The delay between the
Precharge Command and the Activate Command must be greater than or equal to the Precharge time
(tRP).
7.16 Self Refresh Command
The Self Refresh Command is defined by having CS , RAS , CAS and CKE held low with WE
high at the rising edge of the clock. All banks must be idle prior to issuing the Self Refresh Command.
Once the command is registered, CKE must be held low to keep the device in Self Refresh mode.
When the SDRAM has entered Self Refresh mode all of the external control signals, except CKE, are
disabled. The clock is internally disabled during Self Refresh Operation to save power. The device will
exit Self Refresh operation after CKE is returned high. Any subsequent commands can be issued after
tXSR from the end of Self Refresh Command.
If, during normal operation, AUTO REFRESH cycles are issued in bursts (as opposed to being evenly
distributed), a burst of 4,096 AUTO REFRESH cycles should be completed just prior to entering and
just after exiting the self refresh mode.
- 10 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
7.17 Power-down Mode
The Power-down mode is initiated by holding CKE low. All of the receiver circuits except CKE are
gated off to reduce the power. The Power-down mode does not perform any refresh operations,
therefore the device can not remain in Power-down mode longer than the Refresh period (t REF) of the
device.
The Power-down mode is exited by bringing CKE high. When CKE goes high, a No Operation
Command is required on the next rising clock edge, depending on t CK. The input buffers need to be
enabled with CKE held high for a period equal to tCKS (min) + tCK (min).
7.18 No Operation Command
The No Operation Command should be used in cases when the SDRAM is in a idle or a wait state to
prevent the SDRAM from registering any unwanted commands between operations. A No Operation
Command is registered when CS is low with RAS , CAS , and WE held high at the rising edge of
the clock. A No Operation Command will not terminate a previous operation that is still executing, such
as a burst read or write cycle.
7.19 Deselect Command
The Deselect Command performs the same function as a No Operation Command. Deselect
Command occurs when CS is brought high, the RAS , CAS , and WE signals become don’t
cares.
7.20 Clock Suspend Mode
During normal access mode, CKE must be held high enabling the clock. When CKE is registered low
while at least one of the banks is active, Clock Suspend Mode is entered. The Clock Suspend mode
deactivates the internal clock and suspends any clocked operation that was currently being executed.
There is a one clock delay between the registration of CKE low and the time at which the SDRAM
operation suspends. While in Clock Suspend mode, the SDRAM ignores any new commands that are
issued. The Clock Suspend mode is exited by bringing CKE high. There is a one clock cycle delay
from when CKE returns high to when Clock Suspend mode is exited.
- 11 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
8. OPERATION MODE
Fully synchronous operations are performed to latch the commands at the positive edges of CLK.
Table 1 shows the truth table for the operation commands.
Table 1 Truth Table (Note (1), (2))
COMMAND
DEVICE
STATE
CKEn-1 CKEn DQM BS0, 1 A10
A0A9
A11
CS
RAS
CAS
WE
Bank Active
Idle
H
x
x
v
v
v
L
L
H
H
Bank Precharge
Any
H
x
x
v
L
x
L
L
H
L
Precharge All
Any
H
x
x
x
H
x
L
L
H
L
Write
Active (3)
H
x
x
v
L
v
L
H
L
L
Write with Auto-precharge
Active (3)
H
x
x
v
H
v
L
H
L
L
Active
(3)
H
x
x
v
L
v
L
H
L
H
Active
(3)
H
x
x
v
H
v
L
H
L
H
H
x
x
v
v
v
L
L
L
L
H
x
x
x
x
x
L
H
H
H
H
x
x
x
x
x
L
H
H
L
Read
Read with Auto-precharge
Mode Register Set
Idle
No – Operation
Any
Burst Stop
Active
(4)
Device Deselect
Any
H
x
x
x
x
x
H
x
x
x
Auto - Refresh
Idle
H
H
x
x
x
x
L
L
L
H
Self - Refresh Entry
Idle
H
L
x
x
x
x
L
L
L
H
Self Refresh Exit
idle
(S.R.)
L
L
H
H
x
x
x
x
x
x
x
x
H
L
x
H
x
H
Clock suspend Mode Entry
Active
H
L
x
x
x
x
x
x
x
x
x
X
x
Power Down Mode Entry
Idle
Active (5)
H
H
L
L
x
x
x
x
x
x
x
x
H
L
x
H
x
H
Clock Suspend Mode Exit
Active
L
H
x
x
x
x
x
x
x
x
x
X
x
Any
(power down)
L
L
H
H
x
x
x
x
x
x
x
x
H
L
x
H
x
H
x
x
Data write/Output Enable
Active
H
x
L
x
x
x
x
x
x
x
Data Write/Output Disable
Active
H
x
H
x
x
x
x
x
x
x
Power Down Mode Exit
Notes:
(1) v = valid x = Don’t care
L = Low Level H = High Level
(2) CKEn signal is input level when commands are provided.
CKEn-1 signal is the input level one clock cycle before the command is issued.
(3) These are state of bank designated by BS0, BS1 signals.
(4) Device state is full page burst operation.
(5) Power-down Mode can not be entered in the burst cycle.
When this command asserts in the burst cycle, device state is clock suspend mode.
- 12 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
9. ELECTRICAL CHARACTERISTICS
9.1 Absolute Maximum Ratings
PARAMETER
SYMBOL
RATING
UNIT
Input/Output Voltage
VIN, VOUT
-0.5 ~ VDD + 0.5 ( 4.6V max.)
V
Power Supply Voltage
VDD, VDDQ
-0.5 ~ 4.6
V
Operating Temperature(-6/-75)
TOPR
0 ~ 70
°C
Operating Temperature(-6I/75I)
TOPR
-40 ~ 85
°C
Storage Temperature
TSTG
-55 ~ 150
°C
TSOLDER
260
°C
PD
1
W
IOUT
50
mA
Soldering Temperature (10s)
Power Dissipation
Short Circuit Output Current
Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect the life and reliability
of the device.
9.2
Recommended DC Operating Conditions
(TA = 0 to 70°C for -6/-75, TA= -40 to 85°C for -6I/75I)
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
VDD
3.0
3.3
3.6
V
VDDQ
3.0
3.3
3.6
V
VDD
2.7
3.3
3.6
V
VDDQ
2.7
3.3
3.6
V
Input High Voltage
VIH
2.0
-
VDD +0.3
V
Input Low Voltage
VIL
-0.3
-
0.8
V
Power Supply Voltage for -6
Power Supply Voltage for -6 (for I/O Buffer)
Power Supply Voltage (for -6I/-75/75I, CL=3)
Power Supply Voltage
(for -6I/-75/75I, CL=3) (for I/O Buffer)
Note: VIH(max) = VDD/ VDDQ+1.5V for pulse width < 5 nS
VIL(min) = VSS/ VSSQ-1.5V for pulse width < 5 nS
9.3
Capacitance
(VDD = 3.3V  0.3V for-6, VDD = 2.7V~3.6V for -6I/-75/75I, f = 1 MHz, TA = 25°C)
PARAMETER
SYMBOL
MIN.
MAX.
UNIT
Input Capacitance
(A0 to A11, BS0, BS1, CS , RAS , CAS , WE , DQM, CKE)
CI
-
3.8
pf
Input Capacitance (CLK)
CCLK
-
3.5
pf
Input/Output capacitance
CIO
-
6.5
pf
- 13 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
Note: These parameters are periodically sampled and not 100% tested.
9.4
DC Characteristics
(VDD = 3.3V  0.3V for-6, VDD = 2.7V~3.6V for -6I/-75/75I, TA = 0 to 70°C for -6/-75, TA = -40 to 85°C for -6I/75I)
PARAMETER
SYM.
-6/-6I
-75/75I
MAX.
MAX.
UNIT
NOTES
Operating Current
tCK = min., tRC = min.
Active precharge
command cycling without
burst operation
1 bank operation
IDD1
100
90
3
CKE = VIH
IDD2
40
40
3
IDD2P
4
4
3
IDD2S
24
24
IDD2PS
4
4
IDD3
70
60
IDD3P
24
24
IDD4
150
140
3, 4
IDD5
130
120
3
IDD6
4
4
Standby Current
tCK = min, CS = VIH
VIH/L = VIH(min)/VIL(max.)
Bank: Inactive state
CKE = VIL
(Power-down mode)
Standby Current
CLK = VIL, CS = VIH
VIH/L = VIH(min)/VIL(max)
BANK: Inactive state
No Operating Current
tCK = min., CS = VIH(min)
BANK: Active state
(4 banks)
CKE = VIH
CKE = VIL
(Power-down mode)
CKE = VIH
CKE = VIL
(Power-down mode)
mA
Burst Operating Current
tCK = min.
Read/ Write command cycling
Auto Refresh Current
tCK = min.
Auto refresh command cycling
Self Refresh Current
Self Refresh Mode
CKE = 0.2V
PARAMETER
Input Leakage Current
(0V  VIN  VDD, all other pins not under test = 0V)
Output Leakage Current
(Output disable , 0V  VOUT  VDDQ)
LVTTL Output H Level Voltage
(IOUT = -2 mA )
LVTTL Output L Level Voltage
(IOUT = 2 mA )
SYM.
MIN.
MAX.
UNIT
II(L)
-5
5
µA
IO(L)
-5
5
µA
VOH
2.4
-
V
VOL
-
0.4
V
- 14 -
NOTES
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
9.5
AC Characteristics and Operating Condition
(VDD = 3.3V  0.3V for -6, VDD = 2.7V~3.6V for -6I/-75/75I, TA = 0 to 70°C for -6/-75, TA = -40 to 85°C for -6I/75I)
PARAMETER
SYM.
MIN.
-6/-6I
MAX.
-75/75I
MIN.
MAX.
UNIT
Ref/Active to Ref/Active Command
Period
tRC
60
Active to precharge Command Period
tRAS
42
tRCD
18
20
nS
tCCD
1
1
tCK
tRP
tRRD
18
20
nS
2
2
tCK
tWR
2
2
tCK
tCK
10
6
Active to Read/Write Command Delay
Time
Read/Write(a) to Read/Write(b)
Command Period
Precharge to Active Command Period
Active(a) to Active(b) Command Period
Write Recovery Time
CL* = 2
CL* = 3
CLK Cycle Time
CL* = 2
CL* = 3
tCH
tCL
CLK High Level width
CLK Low Level width
Access Time from CLK
CL* = 2
CL* = 3
Output Data High
Impedance Time
CL* = 2
CL* = 3
tLZ
Transition Time of CLK (Rise and Fall)
tT
Data-in Set-up Time
Data-in Hold Time
Address Set-up Time
Address Hold Time
CKE Set-up Time
CKE Hold Time
Command Set-up Time
Command Hold Time
Refresh Time
Mode register Set Cycle Time
Exit self refresh to ACTIVE command
tDS
tDH
tAS
tAH
tCKS
tCKH
tCMS
tCMH
tREF
tRSC
tXSR
1000
1000
45
10
7.5
100000
1000
1000
nS
nS
nS
2.5
nS
8
2
2.5
nS
8
6
6
nS
9
5
5.4
nS
9
3
tHZ
Output Data Low Impedance Time
100000
nS
2
tAC
tOH
Output Data Hold Time
65
NOTES
nS
9
6
3
6
nS
7
5
5.4
nS
7
nS
9
0
0
1
1
nS
1.5
1.5
nS
8
1
1
nS
8
1.5
1.5
nS
8
1
1
nS
8
1.5
1.5
nS
8
1
1
nS
8
1.5
1.5
nS
8
1
1
nS
8
64
64
mS
2
2
tCK
72
75
nS
*CL = CAS Latency
- 15 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
Notes:
1. Operation exceeds “Absolute Maximum Ratings” may cause permanent damage to the devices.
2. All voltages are referenced to VSS.
• 2.7V~3.6V power supply for -6I/-75/75I speed grades.
3. These parameters depend on the cycle rate and listed values are measured at a cycle rate with the minimum
values of tCK and tRC.
4. These parameters depend on the output loading conditions. Specified values are obtained with output open.
5. Power up sequence is further described in the “Functional Description” section.
6. AC test load diagram .
1.4 V
50 ohms
output
Z = 50 ohms
30pF
AC TEST LOAD
7. tHZ defines the time at which the outputs achieve the open circuit condition and is not referenced to output
level.
8. Assumed input rise and fall time (tT) = 1nS.
If tr & tf is longer than 1nS, transient time compensation should be considered,
i.e., [(tr + tf)/2-1]nS should be added to the parameter
(The tT maximum can’t be more than 10nS for low frequency application.)
9. If clock rising time (tT) is longer than 1nS, (tT/2-0.5)nS should be added to the parameter.
- 16 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
10. TIMING WAVEFORMS
10.1 Command Input Timing
tCK
tCL
tCH
VIH
CLK
VIL
tT
tCMS
tCMH
tCMS
tCMH
tCMS
tCMH
tCMS
tCMH
tAS
tAH
tCMH
tT
tCMS
CS
RAS
CAS
WE
A0-A11
BS0,1
tCKS
tCKH
tCKS
tCKH
tCKS
tCKH
CKE
- 17 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
10.2 Read Timing
Read CAS Latency
CLK
CS
RAS
CAS
WE
A0-A11
BS0,1
tAC
tLZ
tAC
tOH
Valid
Data-Out
Valid
Data-Out
DQ
Read Command
tHZ
tOH
Burst Length
- 18 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
10.3 Control Timing of Input/Output Data
Control Timing of Input Data
(Word Mask)
CLK
tCMS
tCMH
tCMH
tCMS
DQM
tDS
tDH
tDS
tDS
Valid
Data-in
Valid
Data-in
DQ0~31
tDH
tDH
tDS
tDH
Valid
Data-in
Valid
Data-in
(Clock Mask)
CLK
tCKH
tCKS
tCKH
tDH
tDS
tDH
tCKS
CKE
tDS
DQ0~31
Valid
Data-in
tDS
Valid
Data-in
tDH
tDS
tDH
Valid
Data-in
Valid
Data-in
Control Timing of Output Data
(Output Enable)
CLK
tCMS
tCMH
tCMH
tCMS
DQM
tAC
tOH
tAC
tLZ
Valid
Data-Out
Valid
Data-Out
DQ0~31
tAC
tHZ
tOH
tOH
tAC
tOH
Valid
Data-Out
OPEN
(Clock Mask)
CLK
tCKS
tCKH
tCKH
tCKS
CKE
DQ0~31
tAC
tAC
tAC
tAC
tOH
tOH
tOH
Valid
Data-Out
Valid
Data-Out
- 19 -
tOH
Valid
Data-Out
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
10.4 Mode Register Set Cycle
tRSC
CLK
tCMS
tCMH
tCMS
tCMH
tCMS
tCMH
tCMS
tCMH
tAS
tAH
CS
RAS
CAS
WE
A0-A11
BS0,1
Register
set data
next
command
A0
A1
Burst Length
A2
A3
Addressing Mode
A4
A5
CAS Latency
A2
0
0
0
0
1
1
1
1
A6
A0
A7
"0"
(Test Mode)
A8
"0"
Reserved
WriteA0
Mode
A9
A10
"0"
A0
A11
"0"
BS0
"0"
BS1
"0"
Reserved
A1
A0 A0
A0
0
0
A0
0
1
A0
1
0
A0
1
1
A0
0
0
A0
0
1
A0
1
0
A0
1
1
A0
A3
0
1
A6
0
0
0
0
1
A5
A0 A4
A0
0
0
A0
0
1
A0
1
0
A0
1
1
A0
0
0
A0
A9
0
1
Burst Length
Sequential
Interleave
1
1
2
2
4
4
8
8
Reserved
Reserved
Full Page
Addressing Mode
Sequential
Interleave
CAS Latency
Reserved
Reserved
2
3
Reserved
Single Write Mode
Burst read and Burst write
Burst read and single write
* "Reserved" should stay "0" during MRS cycle.
- 20 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11. OPERATING TIMING EXAMPLE
11.1 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3)
0
1
2
3
4
6
5
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
tRC
tRC
tRC
RAS
tRAS
tRP
tRP
tRAS
tRAS
tRP
tRAS
CAS
WE
BS0
BS1
tRCD
A10
RAa
A0-A9,
A11
RAa
tRCD
tRCD
RBb
CAw
tRCD
RAc
CBx
RBb
RAe
RBd
RAc
CAy
RBd
CBz
RAe
DQM
CKE
tAC
DQ
tRRD
Bank #0
Active
Bank #1
aw1
aw2
aw3
bx0
tRRD
Read
Precharge
Active
tAC
tAC
tAC
aw0
bx1
bx2
bx3
cy0
tRRD
Active
cy2
cy3
tRRD
Precharge
Read
Precharge
Read
cy1
Active
Active
Read
Bank #2
Idle
Bank #3
- 21 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.2 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3, Auto-precharge)
0
1
2
3
4
5
6
7
8
9
11
10
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
tRC
tRC
tRC
RAS
tRAS
tRP
tRAS
tRP
tRAS
tRP
CAS
WE
BS0
BS1
tRCD
tRCD
tRCD
A10
RAa
RBb
A0-A9,
A11
RAa
CAw RBb
tRCD
RBd
RAc
CBx
RAc
RAe
RBd
CAy
CBz
RAe
DQM
CKE
tAC
DQ
tRRD
Bank #0
Active
Bank #1
aw1
aw2
aw3
bx0
bx1
tRRD
Read
Active
tAC
tAC
tAC
aw0
bx2
bx3
cy0
cy1
tRRD
Active
AP*
cy3
dz0
tRRD
Read
AP*
Read
cy2
Active
AP*
Active
Read
Bank #2
Idle
Bank #3
* AP is the internal precharge start timing
- 22 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.3 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
RAS
tRAS
tRP
tRAS
tRP
CAS
WE
BS0
BS1
tRCD
A10
RAa
A0-A9,
A11
RAa
tRCD
tRCD
RBb
CAx
RAc
RBb
RAc
CBy
CAz
DQM
CKE
tAC
DQ
tAC
ax0
ax1
tRRD
Bank #0
Active
Bank #1
ax2
ax3
ax4
ax6
by0
by4
by1
by5
by6
by7
CZ0
tRRD
Read
Precharge
ax5
tAC
Precharge
Active
Read
Active
Read
Precharge
Bank #2
Idle
Bank #3
- 23 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.4 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3, Auto-precharge)
0
1
2
3
4
6
5
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
tRC
CS
RAS
tRAS
tRP
tRAS
tRAS
tRP
CAS
WE
BS0
BS1
tRCD
A10
RAa
A0-A9,
A11
RAa
tRCD
tRCD
RAc
RBb
CAx
CBy
RBb
RAc
CAz
DQM
CKE
tAC
DQ
ax0
ax1
ax2
Active
Bank #1
ax3
ax4
ax5
ax6
ax7
by0
by1
by4
Active
Read
by5
by6
CZ0
tRRD
tRRD
Bank #0
tAC
tAC
Read
AP*
Active
Read
AP*
Bank #2
Idle
Bank #3
* AP is the internal precharge start timing
- 24 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.5 Interleaved Bank Write (Burst Length = 8)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
RAS
tRAS
tRP
tRAS
CAS
tRCD
tRCD
tRCD
WE
BS0
BS1
A10
RAa
A0-A9,
A11
RAa
RBb
CAx
RAc
CBy
RBb
RAc
CAz
DQM
CKE
DQ
ax0
ax1
ax4
ax5
ax6
ax7
by0
by1
tRRD
Bank #0
Active
Bank #1
Bank #2
Bank #3
by2
by3
by4
by5
by6
by7
CZ0
CZ1
CZ2
tRRD
Precharge
Write
Active
Write
Active
Write
Precharge
Idle
- 25 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.6 Interleaved Bank Write (Burst Length = 8, Auto-precharge)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
RAS
tRP
tRAS
tRAS
CAS
WE
BS0
BS1
tRCD
A10
RAa
A0-A9,
A11
RAa
tRCD
tRCD
RBb
CAx
RAb
CBy
RBb
RAc
CAz
DQM
CKE
ax0
DQ
ax1
ax4
ax5
ax6
ax7
by0
by1
AP*
Write
Active
Bank #1
by3
by4
by5
by6
by7
CZ0
CZ1
CZ2
tRRD
tRRD
Bank #0 Active
by2
Write
Active
Write
AP*
Bank #2
Idle
Bank #3
* AP is the internal precharge start timing
- 26 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.7 Page Mode Read (Burst Length = 4, CAS Latency = 3)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
tCCD
tCCD
tCCD
CS
tRAS
tRAS
RAS
CAS
WE
BS0
BS1
tRCD
A10
RAa
A0-A9,
A11
RAa
tRCD
RBb
CAI
RBb
CBx
CAy
CAm
CBz
DQM
CKE
DQ
a0
a1
a2
a3
tAC
tAC
tAC
tAC
bx0
tAC
Ay0
bx1
Ay1
Ay2
am0
am1
am2
bz0
bz1
bz2
bz3
tRRD
Bank #0 Active
Read
Active
Bank #1
Read
Read
Precharge
Read
Read
AP*
Bank #2
Idle
Bank #3
* AP is the internal precharge start timing
- 27 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.8 Page Mode Read / Write (Burst Length = 8, CAS Latency = 3)
0
1
2
3
5
4
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRAS
RAS
CAS
WE
BS0
BS1
tRCD
A10
RAa
A0-A9,
A11
RAa
CAx
CAy
DQM
CKE
tAC
DQ
tWR
ax0
Q Q
Bank #0
Active
ax1
ax3
ax2
Q
Q
ax5
ax4
Q
Q
Read
ay1
ay0
D
D
Write
ay2
D
ay3
D
ay4
D
Precharge
Bank #1
Bank #2
Bank #3
Idle
- 28 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.9 Auto-precharge Read (Burst Length = 4, CAS Latency = 3)
0
1
2
3
4
6
5
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
RAS
tRAS
tRP
tRAS
CAS
WE
BS0
BS1
tRCD
A10
tRCD
RAa
A0-A9,
A11
RAa
RAb
CAw
RAb
CAx
DQM
CKE
tAC
DQ
tAC
aw0
Bank #0
Active
Read
aw1
AP*
aw2
aw3
bx0
Active
Read
bx1
bx2
bx3
AP*
Bank #1
Bank #2
Idle
Bank #3
* AP is the internal precharge start timing
- 29 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.10 Auto-precharge Write (Burst Length = 4)
0
1
2
3
6
5
4
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
tRC
tRC
RAS
tRAS
tRP
tRAS
tRP
CAS
WE
BS0
BS1
tRCD
tRCD
A10
RAa
A0-A9,
A11
RAa
RAb
CAw
RAb
RAc
CAx
RAc
DQM
CKE
DQ
aw0
Active
Bank #0
Write
aw1
aw2
aw3
bx0
AP*
Active
Write
bx1
bx2
bx3
AP*
Active
Bank #1
Bank #2
Idle
* AP is the internal precharge start timing
Bank #3
- 30 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.11 Auto Refresh Cycle
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
tRP
tRC
tRC
CS
RAS
CAS
WE
BS0,1
A10
A0-A9,
A11
DQM
CKE
DQ
All Banks
Prechage
Auto
Refresh
Auto Refresh (Arbitrary Cycle)
- 31 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.12 Self Refresh Cycle
CLK
CS
tRP
RAS
CAS
WE
BS0,1
A10
A0-A9,
A11
DQM
tCKS
tSB
CKE
tCKS
DQ
tXSR
Self Refresh Cycle
All Banks
Precharge
Self Refresh
Entry
No Operation / Command Inhibit
Self Refresh
Exit
- 32 -
Arbitrary Cycle
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.13 Burst Read and Single Write (Burst Length = 4, CAS Latency = 3)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CLK
CS
RAS
CAS
t RCD
WE
BS0
BS1
A10
RBa
A0-A9,
A11
RBa
CBv
CBw
CBx
CBy
CBz
aw0
ax0
ay0
az0
az1
az2
az3
D
D
D
Q
Q
Q
Q
DQM
CKE
tAC
tAC
DQ
Bank #0
Active
av0
av1
av2
av3
Q
Q
Q
Q
Read
Single Write Read
Bank #1
Bank #2
Idle
Bank #3
- 33 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.14 Auto-precharge Timing (Read Cycle)
0
1
Read
AP
2
3
4
5
6
7
8
Q5
Q6
9
10
11
(1) CAS Latency =2
( a ) burst length = 1
Command
DQ
Act
tRP
Q0
( b ) burst length = 2
Command
Read
AP
Act
tRP
DQ
Q0
Q1
( c ) burst length = 4
Command
Read
AP
Act
tRP
DQ
Q0
Q1
Q2
Q3
Q0
Q1
Q2
Q3
( d ) burst length = 8
Command
Read
AP
DQ
Q4
Act
tRP
Q7
(2) CAS Latency =3
( a ) burst length = 1
Command
Read
AP
Act
tRP
Q0
DQ
( b ) burst length = 2
Command
Read
AP
Act
tRP
Q0
DQ
( c ) burst length = 4
Command
Read
Q1
AP
Act
tRP
Q0
DQ
Q1
Q2
Q3
( d ) burst length = 8
Command
Read
AP
Act
tRP
Q0
DQ
Q1
Q2
Q3
Q4
Q5
Q6
Q7
Note )
Read
represents the Read w ith Auto precharge command.
AP
represents the start of internal precharging.
Act
represents the Bank Activate command.
When the Auto precharge command is asserted, the period from Bank Activate command to
the start of internal precgarging must be at least t RAS(min).
- 34 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.15 Auto-precharge Timing (Write Cycle)
0
1
2
3
4
5
6
7
8
9
10
11
12
CLK
(1) CAS Latency = 2
(a) burst length = 1
Command
Write
AP
tWR
DQ
Act
tRP
D0
(b) burst length = 2
Command
Write
AP
Act
tWR
DQ
D0
tRP
D1
(c) burst length = 4
Command
AP
Write
DQ
D0
D1
D2
Act
tRP
tWR
D3
(d) burst length = 8
Command
Write
AP
tWR
DQ
D0
D1
D2
D3
D4
D5
D6
Act
tRP
D7
(2) CAS Latency = 3
(a) burst length = 1
Command
Write
AP
Act
tWR
DQ
(b) burst length = 2
Command
tRP
D0
Write
AP
Act
tWR
DQ
D0
tRP
D1
(c) burst length = 4
Command
Write
AP
Act
tWR
DQ
D0
D1
D2
tRP
D3
(d) burst length = 8
Command
Write
AP
tWR
DQ
D0
D1
D2
D3
D4
D5
D6
Act
tRP
D7
Note )
Write
represents the Write with Auto precharge command.
AP
represents the start of internal precharing.
Act
represents the Bank Activ e command.
When the /auto precharge command is asserted,the period f rom Bank Activ ate
command to the start of intermal precgarging must be at least tRAS (min).
- 35 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.16 Timing Chart of Read to Write Cycle
In the case of Burst Length = 4
(1) CAS Latency=2
0
1
2
3
4
5
D1
D2
D3
D0
D1
D2
D1
D2
D3
D1
D2
6
7
8
9
10
11
9
10
11
Read Write
( a ) C ommand
D QM
DQ
D0
Read
( b ) C ommand
Write
D QM
DQ
D3
(2) CAS Latency=3
Read Write
( a ) C ommand
D QM
D0
DQ
Read
( b ) C ommand
Write
D QM
D0
DQ
D3
Note: The Output data must be masked by DQM to avoid I/O conflict
11.17 Timing Chart of Write to Read Cycle
In the case of Burst Length=4
0
1
2
3
4
5
6
7
8
Q0
Q1
Q2
Q3
Q0
Q1
Q2
Q3
Q0
Q1
Q2
Q3
Q0
Q1
Q2
(1) CAS Latency=2
( a ) C ommand
Write Read
D QM
DQ
( b ) C ommand
D0
Read
Write
D QM
DQ
D0
D1
(2) CAS Latency=3
( a ) C ommand
Write Read
D QM
DQ
( b ) C ommand
D0
Write
Read
D QM
DQ
D0
D1
- 36 -
Q3
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.18 Timing Chart of Burst Stop Cycle (Burst Stop Command)
0
1
2
3
4
5
6
7
8
9
10
11
(1) Read cycle
( a ) CAS latency =2
Command
Read
BST
Q0
DQ
Q1
Q2
Q0
Q1
Q3
Q4
( b )CAS latency = 3
Read
Command
BST
DQ
Q2
Q3
Q4
(2) W rite cycle
Write
Command
DQ
Q0
BST
Q1
Q2
Note:
Q3
Q4
BST
represents the Burst stop command
11.19 Timing Chart of Burst Stop Cycle (Precharge Command)
0
1
2
3
4
5
6
7
8
9
10
11
(1) Read cycle
(a) CAS latency =2
Command
Read
PRCG
DQ
(b) CAS latency =3
Command
Q0
Q1
Q2
Read
Q3
Q4
PRCG
DQ
Q0
Q1
Q2
Q3
Q4
(2) Write cycle
Command
PRCG
Write
tWR
DQM
DQ
Q0
Q1
Q2
Q3
Q4
- 37 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.20 CKE/DQM Input Timing (Write Cycle)
CLK cy cle No.
1
2
3
D1
D2
D3
4
5
6
7
External
CLK
Internal
CKE
DQM
DQ
D5
DQM MASK
D6
CKE MASK
(1)
CLK cy cle No.
1
2
3
D1
D2
D3
4
5
6
7
External
CLK
Internal
CKE
DQM
DQ
DQM MASK
D5
D6
5
6
7
D4
D5
D6
CKE MASK
(2)
CLK cy cle No.
1
2
3
D1
D2
D3
4
External
CLK
Internal
CKE
DQM
DQ
CKE MASK
(3)
- 38 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
11.21 CKE/DQM Input Timing (Read Cycle)
CLK cy cle No.
1
2
3
4
Q1
Q2
Q3
Q4
5
6
7
External
CLK
Internal
CKE
DQM
DQ
Q6
Open
Open
(1 )
CLK cy cle No.
1
2
3
Q1
Q2
Q3
4
5
6
7
External
CLK
Internal
CKE
DQM
DQ
Q6
Q4
Open
(2 )
CLK cy cle No.
1
2
Q1
Q2
3
4
5
6
7
Q4
Q5
Q6
External
CLK
Internal
CKE
DQM
DQ
Q3
(3 )
- 39 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
12. PACKAGE SPECIFICATION
90 Ball TFBGA (8X13 mm2, Ball pitch:0.8mm, Ø =0.45mm)
TOP VIEW
BOTTOM VIEW
Φb
A1 CORNER
A1 CORNER
9 8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
E2
E
e
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
e
D2
D
y
CONTROL DIMENSIONS ARE IN MILLIMETERS.
MILLIMETER
SYMBOL
SEATING PLANE
A1 A
Ball Land
NOM.
MAX.
MIN.
NOM.
MAX.
A
---
---
1.20
---
---
0.047
A1
0.25
---
0.40
0.010
---
0.016
D
7.95
8.00
8.05
0.313
0.315
0.317
6.40 BASIC
D2
E
12.95
e
13.05
0.40
--0.80 BASIC
0.510
0.512
0.514
0.441 BASIC
0.15 BASIC
y
Φb
13.0
0.252 BASIC
11.2 BASIC
E2
Ball Opening
INCH
MIN.
0.006 BASIC
0.50
0.016
---
0.020
0.032 BASIC
Note: Ball land: 0.5mm / Ball opening: 0.4mm
- 40 -
Publication Release Date: Apr. 11, 2011
Revision A01
W9825G2JB
13. REVISION HISTORY
VERSION
DATE
PAGE
A01
Apr. 11, 2011
All
DESCRIPTION
Initial formally data sheet
Important Notice
Winbond products are not designed, intended, authorized or warranted for use as components
in systems or equipment intended for surgical implantation, atomic energy control
instruments, airplane or spaceship instruments, transportation instruments, traffic signal
instruments, combustion control instruments, or for other applications intended to support or
sustain life. Further more, Winbond products are not intended for applications wherein failure
of Winbond products could result or lead to a situation wherein personal injury, death or
severe property or environmental damage could occur.
Winbond customers using or selling these products for use in such applications do so at their
own risk and agree to fully indemnify Winbond for any damages resulting from such improper
use or sales.
- 41 -
Publication Release Date: Apr. 11, 2011
Revision A01