W9825G2JB 2M 4 BANKS 32BITS SDRAM Table of Contents1. 2. 3. 4. 5. 6. 7. 8. 9. 10. GENERAL DESCRIPTION ............................................................................................................. 3 FEATURES .................................................................................................................................... 3 AVAILABLE PART NUMBER ......................................................................................................... 3 BALL CONFIGURATION ............................................................................................................... 4 BALL DESCRIPTIONS ................................................................................................................... 5 BLOCK DIAGRAM.......................................................................................................................... 6 FUNCTIONAL DESCRIPTION ....................................................................................................... 7 7.1 Power Up and Initialization .................................................................................................. 7 7.2 Programming Mode Register............................................................................................... 7 7.3 Bank Activate Command ..................................................................................................... 7 7.4 Read and Write Access Modes ........................................................................................... 7 7.5 Burst Read Command ......................................................................................................... 8 7.6 Burst Write Command ......................................................................................................... 8 7.7 Read Interrupted by a Read ................................................................................................ 8 7.8 Read Interrupted by a Write ................................................................................................ 8 7.9 Write Interrupted by a Write................................................................................................. 8 7.10 Write Interrupted by a Read ................................................................................................ 8 7.11 Burst Stop Command .......................................................................................................... 9 7.12 Addressing Sequence of Sequential Mode ......................................................................... 9 7.13 Addressing Sequence of Interleave Mode .......................................................................... 9 7.14 Auto-precharge Command ................................................................................................ 10 7.15 Precharge Command ........................................................................................................ 10 7.16 Self Refresh Command ..................................................................................................... 10 7.17 Power-down Mode ............................................................................................................. 11 7.18 No Operation Command .................................................................................................... 11 7.19 Deselect Command ........................................................................................................... 11 7.20 Clock Suspend Mode ........................................................................................................ 11 OPERATION MODE..................................................................................................................... 12 ELECTRICAL CHARACTERISTICS ............................................................................................ 13 9.1 Absolute Maximum Ratings ............................................................................................... 13 9.2 Recommended DC Operating Conditions ......................................................................... 13 9.3 Capacitance ....................................................................................................................... 13 9.4 DC Characteristics ............................................................................................................. 14 9.5 AC Characteristics and Operating Condition ..................................................................... 15 TIMING WAVEFORMS ................................................................................................................ 17 10.1 Command Input Timing ..................................................................................................... 17 10.2 Read Timing ...................................................................................................................... 18 -1- Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11. 12. 13. 10.3 Control Timing of Input/Output Data .................................................................................. 19 10.4 Mode Register Set Cycle ................................................................................................... 20 OPERATING TIMING EXAMPLE................................................................................................. 21 11.1 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3) ........................................... 21 11.2 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3, Auto-precharge) ................ 22 11.3 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3) ........................................... 23 11.4 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3, Auto-precharge) ................ 24 11.5 Interleaved Bank Write (Burst Length = 8) ........................................................................ 25 11.6 Interleaved Bank Write (Burst Length = 8, Auto-precharge) ............................................. 26 11.7 Page Mode Read (Burst Length = 4, CAS Latency = 3) ................................................... 27 11.8 Page Mode Read / Write (Burst Length = 8, CAS Latency = 3) ........................................ 28 11.9 Auto-precharge Read (Burst Length = 4, CAS Latency = 3) ............................................. 29 11.10 Auto-precharge Write (Burst Length = 4) .......................................................................... 30 11.11 Auto Refresh Cycle ............................................................................................................ 31 11.12 Self Refresh Cycle ............................................................................................................. 32 11.13 Burst Read and Single Write (Burst Length = 4, CAS Latency = 3) .................................. 33 11.14 Auto-precharge Timing (Read Cycle) ................................................................................ 34 11.15 Auto-precharge Timing (Write Cycle) ................................................................................ 35 11.16 Timing Chart of Read to Write Cycle ................................................................................. 36 11.17 Timing Chart of Write to Read Cycle ................................................................................. 36 11.18 Timing Chart of Burst Stop Cycle (Burst Stop Command) ................................................ 37 11.19 Timing Chart of Burst Stop Cycle (Precharge Command) ................................................ 37 11.20 CKE/DQM Input Timing (Write Cycle) ............................................................................... 38 11.21 CKE/DQM Input Timing (Read Cycle) ............................................................................... 39 PACKAGE SPECIFICATION ....................................................................................................... 40 REVISION HISTORY ................................................................................................................... 41 -2- Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 1. GENERAL DESCRIPTION W9825G2JB is a high-speed synchronous dynamic random access memory (SDRAM), organized as 2,097,152 words 4 banks 32 bits. W9825G2JB delivers a data bandwidth of up to 166M words per second. For different application, W9825G2JB is sorted into two speed grades: -6, -75. The -6/-6I is compliant to the 166MHz/CL3 specification, (the -6I grade which is guaranteed to support -40°C ~ 85°C) ,the -75/75I is compliant to the PC133/CL3 specification (the 75I grade which is guaranteed to support -40°C ~ 85°C). Accesses to the SDRAM are burst oriented. Consecutive memory location in one page can be accessed at a burst length of 1, 2, 4, 8 or full page when a bank and row is selected by an ACTIVE command. Column addresses are automatically generated by the SDRAM internal counter in burst operation. Random column read is also possible by providing its address at each clock cycle. The multiple bank nature enables interleaving among internal banks to hide the precharging time. By having a programmable Mode Register, the system can change burst length, latency cycle, interleave or sequential burst to maximize its performance. W9825G2JB is ideal for main memory in high performance applications. 2. FEATURES 3.3V 0.3V for -6 speed grades power supply 2.7V~3.6V for -6I/-75/75I speed grades power supply Up to 166 MHz Clock Frequency 2,097,152 Words 4 banks 32 bits organization Self Refresh Mode: Standard and Low Power CAS Latency: 2 and 3 Burst Length: 1, 2, 4, 8 and full page Burst Read, Single Writes Mode Byte Data Controlled by DQM Auto-precharge and Controlled Precharge 4K Refresh cycles / 64 mS Interface: LVTTL Package: 90 Balls TFBGA, using Lead free materials with RoHS compliant Dual-Die package 3. AVAILABLE PART NUMBER PART NUMBER SELF REFRESH CURRENT (MAX) SPEED GRADE OPERATING TEMPERATURE W9825G2JB-6 166MHz/CL3 4 mA 0°C ~ 70°C W9825G2JB-6I 166MHz/CL3 4 mA -40°C ~ 85°C W9825G2JB-75 133MHz/CL3 4 mA 0°C ~ 70°C W9825G2JB75I 133MHz/CL3 4 mA -40°C ~ 85°C - 3 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 4. BALL CONFIGURATION Top View 1 2 3 4 5 6 7 8 9 A DQ26 DQ24 VSS VDD DQ23 DQ21 DQ28 VDDQ VSSQ VDDQ VSSQ DQ19 VSSQ DQ27 DQ25 DQ22 DQ20 VDDQ VSSQ DQ29 DQ30 DQ17 DQ18 VDDQ VDDQ DQ31 NC NC DQ16 VSSQ VSS DQM3 A3 A2 DQM2 VDD A4 A5 A6 A10 A0 A1 A7 A8 NC NC BS1 A11 CKE A9 BS0 CS# RAS# DQM1 NC NC CAS# WE# DQM0 VDDQ DQ8 VSS VDD DQ7 VSSQ VSSQ DQ10 DQ9 DQ6 DQ5 VDDQ VSSQ DQ12 DQ14 DQ1 DQ3 VDDQ DQ11 VDDQ VSSQ VDDQ VSSQ DQ4 DQ13 DQ15 VSS VDD DQ0 DQ2 B C D E F G H J CLK K L M N P R -4- Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 5. BALL DESCRIPTIONS BALL LOCATION PIN NAME FUNCTION DESCRIPTION G8,G9,F7,F3,G1,G2, G3,H1,H2,J3,G7,H9 A0A11 Address Multiplexed pins for row and column address. Row address: A0A11. Column address: A0A8. A10 is sampled during a precharge command to determine if all banks are to be precharged or bank selected by BS0, BS1. J7,H8 BS0, BS1 Bank Select Select bank to activate during row address latch time, or bank to read/write during address latch time. Data Input/ Output Multiplexed pins for data output and input. CS Chip Select Disable or enable the command decoder. When command decoder is disabled, new command is ignored and previous operation continues. J9 RAS Row Address Strobe K7 CAS K8 WE A1,A2,A8,A9,B1,B9, C2,C3,C7,C8,D2,D3, D7,D8,E2,E8,L2,L8, DQ0DQ31 M2,M3,M7,M8,N2,N3 ,N7,N8,P1,P9,R1,R2, R8,R9 J8 Command input. When sampled at the rising edge of the clock RAS , CAS and WE define the operation to be executed. Column Address Referred to RAS Strobe Write Enable Referred to RAS The output buffer is placed at Hi-Z (with latency of 2) when DQM is sampled high in read cycle. In write cycle, Input/output mask sampling DQM high will block the write operation with zero latency. F2,F8,K1,K9 DQM03 J1 CLK Clock Inputs System clock used to sample inputs on the rising edge of clock. J2 CKE Clock Enable CKE controls the clock activation and deactivation. When CKE is low, Power-down mode, Suspend mode, or Self Refresh mode is entered. A7,F9,L7,R7 VDD Power Power for input buffers and logic circuit inside DRAM. A3,F1,L3,R3 VSS Ground Ground for input buffers and logic circuit inside DRAM. B2,B7,C9,D9,E1,L1, M9,N9,P2,P7 VDDQ Power for I/O buffer Separated power from VDD, to improve DQ noise immunity. B8,B3,C1,D1,E9,L9, M1,N1,P3,P8, VSSQ Ground for I/O buffer Separated ground from VSS, to improve DQ noise immunity. E3,E7,H3,H7,K2,K3 NC No Connection No connection. - 5 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 6. BLOCK DIAGRAM CLK CLOCK BUFFER CKE CONTROL SIGNAL GENERATOR CS RAS COMMAND DECODER WE ROW DECODER COLUMN DECODER A10 MODE REGISTER A0 COLUMN DECODER ROW DECODER CAS CELL ARRAY BANK #0 CELL ARRAY BANK #1 SENSE AMPLIFIER SENSE AMPLIFIER ADDRESS BUFFER A9 A11 BS0 BS1 DQ BUFFER DATA CONTROL CIRCUIT COLUMN COUNTER DQM0 - 3 COLUMN DECODER ROW DECODER COLUMN DECODER ROW DECODER REFRESH COUNTER DQ0 - 31 CELL ARRAY BANK #2 SENSE AMPLIFIER CELL ARRAY BANK #3 SENSE AMPLIFIER Note: The cell array configuration is 4049 * 512 * 32 -6- Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 7. FUNCTIONAL DESCRIPTION 7.1 Power Up and Initialization The default power up state of the mode register is unspecified. The following power up and initialization sequence need to be followed to guarantee the device being preconditioned to each user specific needs. During power up, all VDD and VDDQ pins must be ramp up simultaneously to the specified voltage when the input signals are held in the “NOP” state. The power up voltage must not exceed V DD +0.3V on any of the input pins or VDD supplies. After power up, an initial pause of 200 µS is required followed by a precharge of all banks using the precharge command. To prevent data contention on the DQ bus during power up, it is required that the DQM and CKE pins be held high during the initial pause period. Once all banks have been precharged, the Mode Register Set Command must be issued to initialize the Mode Register. An additional eight Auto Refresh cycles (CBR) are also required before or after programming the Mode Register to ensure proper subsequent operation. 7.2 Programming Mode Register After initial power up, the Mode Register Set Command must be issued for proper device operation. All banks must be in a precharged state and CKE must be high at least one cycle before the Mode Register Set Command can be issued. The Mode Register Set Command is activated by the low signals of RAS , CAS , CS and WE at the positive edge of the clock. The address input data during this cycle defines the parameters to be set as shown in the Mode Register Operation table. A new command may be issued following the mode register set command once a delay equal to tRSC has elapsed. Please refer to the next page for Mode Register Set Cycle and Operation Table. 7.3 Bank Activate Command The Bank Activate command must be applied before any Read or Write operation can be executed. The operation is similar to RAS activate in EDO DRAM. The delay from when the Bank Activate command is applied to when the first read or write operation can begin must not be less than the RAS to CAS delay time (tRCD). Once a bank has been activated it must be precharged before another Bank Activate command can be issued to the same bank. The minimum time interval between successive Bank Activate commands to the same bank is determined by the RAS cycle time of the device (t RC). The minimum time interval between interleaved Bank Activate commands (Bank A to Bank B and vice versa) is the Bank to Bank delay time (tRRD). The maximum time that each bank can be held active is specified as tRAS (max). 7.4 Read and Write Access Modes After a bank has been activated, a read or write cycle can be followed. This is accomplished by setting RAS high and CAS low at the clock rising edge after minimum of tRCD delay. WE pin voltage level defines whether the access cycle is a read operation ( WE high), or a write operation ( WE low). The address inputs determine the starting column address. Reading or writing to a different row within an activated bank requires the bank be precharged and a new Bank Activate command be issued. When more than one bank is activated, interleaved bank Read or Write operations are possible. By using the programmed burst length and alternating the access and precharge operations between multiple banks, seamless data access operation among many different pages can be realized. Read or Write Commands can also be issued to the same bank or between active banks on every clock cycle. - 7 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 7.5 Burst Read Command The Burst Read command is initiated by applying logic low level to CS and CAS while holding RAS and WE high at the rising edge of the clock. The address inputs determine the starting column address for the burst. The Mode Register sets type of burst (sequential or interleave) and the burst length (1, 2, 4, 8, full page) during the Mode Register Set Up cycle. Table 2 and 3 in the next page explain the address sequence of interleave mode and sequential mode. 7.6 Burst Write Command The Burst Write command is initiated by applying logic low level to CS , CAS and WE while holding RAS high at the rising edge of the clock. The address inputs determine the starting column address. Data for the first burst write cycle must be applied on the DQ pins on the same clock cycle that the Write Command is issued. The remaining data inputs must be supplied on each subsequent rising clock edge until the burst length is completed. Data supplied to the DQ pins after burst finishes will be ignored. 7.7 Read Interrupted by a Read A Burst Read may be interrupted by another Read Command. When the previous burst is interrupted, the remaining addresses are overridden by the new read address with the full burst length. The data from the first Read Command continues to appear on the outputs until the CAS Latency from the interrupting Read Command the is satisfied. 7.8 Read Interrupted by a Write To interrupt a burst read with a Write Command, DQM may be needed to place the DQs (output drivers) in a high impedance state to avoid data contention on the DQ bus. If a Read Command will issue data on the first and second clocks cycles of the write operation, DQM is needed to insure the DQs are tri-stated. After that point the Write Command will have control of the DQ bus and DQM masking is no longer needed. 7.9 Write Interrupted by a Write A burst write may be interrupted before completion of the burst by another Write Command. When the previous burst is interrupted, the remaining addresses are overridden by the new address and data will be written into the device until the programmed burst length is satisfied. 7.10 Write Interrupted by a Read A Read Command will interrupt a burst write operation on the same clock cycle that the Read Command is activated. The DQs must be in the high impedance state at least one cycle before the new read data appears on the outputs to avoid data contention. When the Read Command is activated, any residual data from the burst write cycle will be ignored. -8- Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 7.11 Burst Stop Command A Burst Stop Command may be used to terminate the existing burst operation but leave the bank open for future Read or Write Commands to the same page of the active bank, if the burst length is full page. Use of the Burst Stop Command during other burst length operations is illegal. The Burst Stop Command is defined by having RAS and CAS high with CS and WE low at the rising edge of the clock. The data DQs go to a high impedance state after a delay which is equal to the CAS Latency in a burst read cycle interrupted by Burst Stop. 7.12 Addressing Sequence of Sequential Mode A column access is performed by increasing the address from the column address which is input to the device. The disturb address is varied by the Burst Length as shown in Table 2. Table 2 Address Sequence of Sequential Mode DATA ACCESS ADDRESS BURST LENGTH Data 0 n BL = 2 (disturb address is A0) Data 1 n+1 No address carry from A0 to A1 Data 2 n+2 BL = 4 (disturb addresses are A0 and A1) Data 3 n+3 No address carry from A1 to A2 Data 4 n+4 Data 5 n+5 BL = 8 (disturb addresses are A0, A1 and A2) Data 6 n+6 No address carry from A2 to A3 Data 7 n+7 7.13 Addressing Sequence of Interleave Mode A column access is started in the input column address and is performed by inverting the address bit in the sequence shown in Table 3. Table 3 Address Sequence of Interleave Mode DATA ACCESS ADDRESS Data 0 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 1 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 2 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 3 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 4 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 5 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 6 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 7 A8 A7 A6 A5 A4 A3 A2 A1 A0 - 9 - BURST LENGTH BL = 2 BL = 4 BL = 8 Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 7.14 Auto-precharge Command If A10 is set to high when the Read or Write Command is issued, then the Auto-precharge function is entered. During Auto-precharge, a Read Command will execute as normal with the exception that the active bank will begin to precharge automatically before all burst read cycles have been completed. Regardless of burst length, it will begin a certain number of clocks prior to the end of the scheduled burst cycle. The number of clocks is determined by CAS Latency. A Read or Write Command with Auto-precharge can not be interrupted before the entire burst operation is completed. Therefore, use of a Read, Write or Precharge Command is prohibited during a read or write cycle with Auto-precharge. Once the precharge operation has started, the bank cannot be reactivated until the Precharge time (tRP) has been satisfied. Issue of Auto-precharge command is illegal if the burst is set to full page length. If A10 is high when a Write Command is issued, the Write with Auto-precharge function is initiated. The SDRAM automatically enters the precharge operation two clocks delay from the last burst write cycle. This delay is referred to as Write tWR. The bank undergoing Auto-precharge can not be reactivated until tWR and tRP are satisfied. This is referred to as tDAL, Data-in to Active delay (tDAL = tWR + tRP). When using the Auto-precharge Command, the interval between the Bank Activate Command and the beginning of the internal precharge operation must satisfy tRAS (min). 7.15 Precharge Command The Precharge Command is used to precharge or close a bank that has been activated. The Precharge Command is entered when CS , RAS and WE are low and CAS is high at the rising edge of the clock. The Precharge Command can be used to precharge each bank separately or all banks simultaneously. Three address bits, A10, BS0, and BS1, are used to define which bank(s) is to be precharged when the command is issued. After the Precharge Command is issued, the precharged bank must be reactivated before a new read or write access can be executed. The delay between the Precharge Command and the Activate Command must be greater than or equal to the Precharge time (tRP). 7.16 Self Refresh Command The Self Refresh Command is defined by having CS , RAS , CAS and CKE held low with WE high at the rising edge of the clock. All banks must be idle prior to issuing the Self Refresh Command. Once the command is registered, CKE must be held low to keep the device in Self Refresh mode. When the SDRAM has entered Self Refresh mode all of the external control signals, except CKE, are disabled. The clock is internally disabled during Self Refresh Operation to save power. The device will exit Self Refresh operation after CKE is returned high. Any subsequent commands can be issued after tXSR from the end of Self Refresh Command. If, during normal operation, AUTO REFRESH cycles are issued in bursts (as opposed to being evenly distributed), a burst of 4,096 AUTO REFRESH cycles should be completed just prior to entering and just after exiting the self refresh mode. - 10 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 7.17 Power-down Mode The Power-down mode is initiated by holding CKE low. All of the receiver circuits except CKE are gated off to reduce the power. The Power-down mode does not perform any refresh operations, therefore the device can not remain in Power-down mode longer than the Refresh period (t REF) of the device. The Power-down mode is exited by bringing CKE high. When CKE goes high, a No Operation Command is required on the next rising clock edge, depending on t CK. The input buffers need to be enabled with CKE held high for a period equal to tCKS (min) + tCK (min). 7.18 No Operation Command The No Operation Command should be used in cases when the SDRAM is in a idle or a wait state to prevent the SDRAM from registering any unwanted commands between operations. A No Operation Command is registered when CS is low with RAS , CAS , and WE held high at the rising edge of the clock. A No Operation Command will not terminate a previous operation that is still executing, such as a burst read or write cycle. 7.19 Deselect Command The Deselect Command performs the same function as a No Operation Command. Deselect Command occurs when CS is brought high, the RAS , CAS , and WE signals become don’t cares. 7.20 Clock Suspend Mode During normal access mode, CKE must be held high enabling the clock. When CKE is registered low while at least one of the banks is active, Clock Suspend Mode is entered. The Clock Suspend mode deactivates the internal clock and suspends any clocked operation that was currently being executed. There is a one clock delay between the registration of CKE low and the time at which the SDRAM operation suspends. While in Clock Suspend mode, the SDRAM ignores any new commands that are issued. The Clock Suspend mode is exited by bringing CKE high. There is a one clock cycle delay from when CKE returns high to when Clock Suspend mode is exited. - 11 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 8. OPERATION MODE Fully synchronous operations are performed to latch the commands at the positive edges of CLK. Table 1 shows the truth table for the operation commands. Table 1 Truth Table (Note (1), (2)) COMMAND DEVICE STATE CKEn-1 CKEn DQM BS0, 1 A10 A0A9 A11 CS RAS CAS WE Bank Active Idle H x x v v v L L H H Bank Precharge Any H x x v L x L L H L Precharge All Any H x x x H x L L H L Write Active (3) H x x v L v L H L L Write with Auto-precharge Active (3) H x x v H v L H L L Active (3) H x x v L v L H L H Active (3) H x x v H v L H L H H x x v v v L L L L H x x x x x L H H H H x x x x x L H H L Read Read with Auto-precharge Mode Register Set Idle No – Operation Any Burst Stop Active (4) Device Deselect Any H x x x x x H x x x Auto - Refresh Idle H H x x x x L L L H Self - Refresh Entry Idle H L x x x x L L L H Self Refresh Exit idle (S.R.) L L H H x x x x x x x x H L x H x H Clock suspend Mode Entry Active H L x x x x x x x x x X x Power Down Mode Entry Idle Active (5) H H L L x x x x x x x x H L x H x H Clock Suspend Mode Exit Active L H x x x x x x x x x X x Any (power down) L L H H x x x x x x x x H L x H x H x x Data write/Output Enable Active H x L x x x x x x x Data Write/Output Disable Active H x H x x x x x x x Power Down Mode Exit Notes: (1) v = valid x = Don’t care L = Low Level H = High Level (2) CKEn signal is input level when commands are provided. CKEn-1 signal is the input level one clock cycle before the command is issued. (3) These are state of bank designated by BS0, BS1 signals. (4) Device state is full page burst operation. (5) Power-down Mode can not be entered in the burst cycle. When this command asserts in the burst cycle, device state is clock suspend mode. - 12 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 9. ELECTRICAL CHARACTERISTICS 9.1 Absolute Maximum Ratings PARAMETER SYMBOL RATING UNIT Input/Output Voltage VIN, VOUT -0.5 ~ VDD + 0.5 ( 4.6V max.) V Power Supply Voltage VDD, VDDQ -0.5 ~ 4.6 V Operating Temperature(-6/-75) TOPR 0 ~ 70 °C Operating Temperature(-6I/75I) TOPR -40 ~ 85 °C Storage Temperature TSTG -55 ~ 150 °C TSOLDER 260 °C PD 1 W IOUT 50 mA Soldering Temperature (10s) Power Dissipation Short Circuit Output Current Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect the life and reliability of the device. 9.2 Recommended DC Operating Conditions (TA = 0 to 70°C for -6/-75, TA= -40 to 85°C for -6I/75I) PARAMETER SYMBOL MIN. TYP. MAX. UNIT VDD 3.0 3.3 3.6 V VDDQ 3.0 3.3 3.6 V VDD 2.7 3.3 3.6 V VDDQ 2.7 3.3 3.6 V Input High Voltage VIH 2.0 - VDD +0.3 V Input Low Voltage VIL -0.3 - 0.8 V Power Supply Voltage for -6 Power Supply Voltage for -6 (for I/O Buffer) Power Supply Voltage (for -6I/-75/75I, CL=3) Power Supply Voltage (for -6I/-75/75I, CL=3) (for I/O Buffer) Note: VIH(max) = VDD/ VDDQ+1.5V for pulse width < 5 nS VIL(min) = VSS/ VSSQ-1.5V for pulse width < 5 nS 9.3 Capacitance (VDD = 3.3V 0.3V for-6, VDD = 2.7V~3.6V for -6I/-75/75I, f = 1 MHz, TA = 25°C) PARAMETER SYMBOL MIN. MAX. UNIT Input Capacitance (A0 to A11, BS0, BS1, CS , RAS , CAS , WE , DQM, CKE) CI - 3.8 pf Input Capacitance (CLK) CCLK - 3.5 pf Input/Output capacitance CIO - 6.5 pf - 13 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB Note: These parameters are periodically sampled and not 100% tested. 9.4 DC Characteristics (VDD = 3.3V 0.3V for-6, VDD = 2.7V~3.6V for -6I/-75/75I, TA = 0 to 70°C for -6/-75, TA = -40 to 85°C for -6I/75I) PARAMETER SYM. -6/-6I -75/75I MAX. MAX. UNIT NOTES Operating Current tCK = min., tRC = min. Active precharge command cycling without burst operation 1 bank operation IDD1 100 90 3 CKE = VIH IDD2 40 40 3 IDD2P 4 4 3 IDD2S 24 24 IDD2PS 4 4 IDD3 70 60 IDD3P 24 24 IDD4 150 140 3, 4 IDD5 130 120 3 IDD6 4 4 Standby Current tCK = min, CS = VIH VIH/L = VIH(min)/VIL(max.) Bank: Inactive state CKE = VIL (Power-down mode) Standby Current CLK = VIL, CS = VIH VIH/L = VIH(min)/VIL(max) BANK: Inactive state No Operating Current tCK = min., CS = VIH(min) BANK: Active state (4 banks) CKE = VIH CKE = VIL (Power-down mode) CKE = VIH CKE = VIL (Power-down mode) mA Burst Operating Current tCK = min. Read/ Write command cycling Auto Refresh Current tCK = min. Auto refresh command cycling Self Refresh Current Self Refresh Mode CKE = 0.2V PARAMETER Input Leakage Current (0V VIN VDD, all other pins not under test = 0V) Output Leakage Current (Output disable , 0V VOUT VDDQ) LVTTL Output H Level Voltage (IOUT = -2 mA ) LVTTL Output L Level Voltage (IOUT = 2 mA ) SYM. MIN. MAX. UNIT II(L) -5 5 µA IO(L) -5 5 µA VOH 2.4 - V VOL - 0.4 V - 14 - NOTES Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 9.5 AC Characteristics and Operating Condition (VDD = 3.3V 0.3V for -6, VDD = 2.7V~3.6V for -6I/-75/75I, TA = 0 to 70°C for -6/-75, TA = -40 to 85°C for -6I/75I) PARAMETER SYM. MIN. -6/-6I MAX. -75/75I MIN. MAX. UNIT Ref/Active to Ref/Active Command Period tRC 60 Active to precharge Command Period tRAS 42 tRCD 18 20 nS tCCD 1 1 tCK tRP tRRD 18 20 nS 2 2 tCK tWR 2 2 tCK tCK 10 6 Active to Read/Write Command Delay Time Read/Write(a) to Read/Write(b) Command Period Precharge to Active Command Period Active(a) to Active(b) Command Period Write Recovery Time CL* = 2 CL* = 3 CLK Cycle Time CL* = 2 CL* = 3 tCH tCL CLK High Level width CLK Low Level width Access Time from CLK CL* = 2 CL* = 3 Output Data High Impedance Time CL* = 2 CL* = 3 tLZ Transition Time of CLK (Rise and Fall) tT Data-in Set-up Time Data-in Hold Time Address Set-up Time Address Hold Time CKE Set-up Time CKE Hold Time Command Set-up Time Command Hold Time Refresh Time Mode register Set Cycle Time Exit self refresh to ACTIVE command tDS tDH tAS tAH tCKS tCKH tCMS tCMH tREF tRSC tXSR 1000 1000 45 10 7.5 100000 1000 1000 nS nS nS 2.5 nS 8 2 2.5 nS 8 6 6 nS 9 5 5.4 nS 9 3 tHZ Output Data Low Impedance Time 100000 nS 2 tAC tOH Output Data Hold Time 65 NOTES nS 9 6 3 6 nS 7 5 5.4 nS 7 nS 9 0 0 1 1 nS 1.5 1.5 nS 8 1 1 nS 8 1.5 1.5 nS 8 1 1 nS 8 1.5 1.5 nS 8 1 1 nS 8 1.5 1.5 nS 8 1 1 nS 8 64 64 mS 2 2 tCK 72 75 nS *CL = CAS Latency - 15 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB Notes: 1. Operation exceeds “Absolute Maximum Ratings” may cause permanent damage to the devices. 2. All voltages are referenced to VSS. • 2.7V~3.6V power supply for -6I/-75/75I speed grades. 3. These parameters depend on the cycle rate and listed values are measured at a cycle rate with the minimum values of tCK and tRC. 4. These parameters depend on the output loading conditions. Specified values are obtained with output open. 5. Power up sequence is further described in the “Functional Description” section. 6. AC test load diagram . 1.4 V 50 ohms output Z = 50 ohms 30pF AC TEST LOAD 7. tHZ defines the time at which the outputs achieve the open circuit condition and is not referenced to output level. 8. Assumed input rise and fall time (tT) = 1nS. If tr & tf is longer than 1nS, transient time compensation should be considered, i.e., [(tr + tf)/2-1]nS should be added to the parameter (The tT maximum can’t be more than 10nS for low frequency application.) 9. If clock rising time (tT) is longer than 1nS, (tT/2-0.5)nS should be added to the parameter. - 16 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 10. TIMING WAVEFORMS 10.1 Command Input Timing tCK tCL tCH VIH CLK VIL tT tCMS tCMH tCMS tCMH tCMS tCMH tCMS tCMH tAS tAH tCMH tT tCMS CS RAS CAS WE A0-A11 BS0,1 tCKS tCKH tCKS tCKH tCKS tCKH CKE - 17 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 10.2 Read Timing Read CAS Latency CLK CS RAS CAS WE A0-A11 BS0,1 tAC tLZ tAC tOH Valid Data-Out Valid Data-Out DQ Read Command tHZ tOH Burst Length - 18 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 10.3 Control Timing of Input/Output Data Control Timing of Input Data (Word Mask) CLK tCMS tCMH tCMH tCMS DQM tDS tDH tDS tDS Valid Data-in Valid Data-in DQ0~31 tDH tDH tDS tDH Valid Data-in Valid Data-in (Clock Mask) CLK tCKH tCKS tCKH tDH tDS tDH tCKS CKE tDS DQ0~31 Valid Data-in tDS Valid Data-in tDH tDS tDH Valid Data-in Valid Data-in Control Timing of Output Data (Output Enable) CLK tCMS tCMH tCMH tCMS DQM tAC tOH tAC tLZ Valid Data-Out Valid Data-Out DQ0~31 tAC tHZ tOH tOH tAC tOH Valid Data-Out OPEN (Clock Mask) CLK tCKS tCKH tCKH tCKS CKE DQ0~31 tAC tAC tAC tAC tOH tOH tOH Valid Data-Out Valid Data-Out - 19 - tOH Valid Data-Out Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 10.4 Mode Register Set Cycle tRSC CLK tCMS tCMH tCMS tCMH tCMS tCMH tCMS tCMH tAS tAH CS RAS CAS WE A0-A11 BS0,1 Register set data next command A0 A1 Burst Length A2 A3 Addressing Mode A4 A5 CAS Latency A2 0 0 0 0 1 1 1 1 A6 A0 A7 "0" (Test Mode) A8 "0" Reserved WriteA0 Mode A9 A10 "0" A0 A11 "0" BS0 "0" BS1 "0" Reserved A1 A0 A0 A0 0 0 A0 0 1 A0 1 0 A0 1 1 A0 0 0 A0 0 1 A0 1 0 A0 1 1 A0 A3 0 1 A6 0 0 0 0 1 A5 A0 A4 A0 0 0 A0 0 1 A0 1 0 A0 1 1 A0 0 0 A0 A9 0 1 Burst Length Sequential Interleave 1 1 2 2 4 4 8 8 Reserved Reserved Full Page Addressing Mode Sequential Interleave CAS Latency Reserved Reserved 2 3 Reserved Single Write Mode Burst read and Burst write Burst read and single write * "Reserved" should stay "0" during MRS cycle. - 20 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11. OPERATING TIMING EXAMPLE 11.1 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3) 0 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC tRC tRC tRC RAS tRAS tRP tRP tRAS tRAS tRP tRAS CAS WE BS0 BS1 tRCD A10 RAa A0-A9, A11 RAa tRCD tRCD RBb CAw tRCD RAc CBx RBb RAe RBd RAc CAy RBd CBz RAe DQM CKE tAC DQ tRRD Bank #0 Active Bank #1 aw1 aw2 aw3 bx0 tRRD Read Precharge Active tAC tAC tAC aw0 bx1 bx2 bx3 cy0 tRRD Active cy2 cy3 tRRD Precharge Read Precharge Read cy1 Active Active Read Bank #2 Idle Bank #3 - 21 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.2 Interleaved Bank Read (Burst Length = 4, CAS Latency = 3, Auto-precharge) 0 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC tRC tRC tRC RAS tRAS tRP tRAS tRP tRAS tRP CAS WE BS0 BS1 tRCD tRCD tRCD A10 RAa RBb A0-A9, A11 RAa CAw RBb tRCD RBd RAc CBx RAc RAe RBd CAy CBz RAe DQM CKE tAC DQ tRRD Bank #0 Active Bank #1 aw1 aw2 aw3 bx0 bx1 tRRD Read Active tAC tAC tAC aw0 bx2 bx3 cy0 cy1 tRRD Active AP* cy3 dz0 tRRD Read AP* Read cy2 Active AP* Active Read Bank #2 Idle Bank #3 * AP is the internal precharge start timing - 22 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.3 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC RAS tRAS tRP tRAS tRP CAS WE BS0 BS1 tRCD A10 RAa A0-A9, A11 RAa tRCD tRCD RBb CAx RAc RBb RAc CBy CAz DQM CKE tAC DQ tAC ax0 ax1 tRRD Bank #0 Active Bank #1 ax2 ax3 ax4 ax6 by0 by4 by1 by5 by6 by7 CZ0 tRRD Read Precharge ax5 tAC Precharge Active Read Active Read Precharge Bank #2 Idle Bank #3 - 23 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.4 Interleaved Bank Read (Burst Length = 8, CAS Latency = 3, Auto-precharge) 0 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK tRC CS RAS tRAS tRP tRAS tRAS tRP CAS WE BS0 BS1 tRCD A10 RAa A0-A9, A11 RAa tRCD tRCD RAc RBb CAx CBy RBb RAc CAz DQM CKE tAC DQ ax0 ax1 ax2 Active Bank #1 ax3 ax4 ax5 ax6 ax7 by0 by1 by4 Active Read by5 by6 CZ0 tRRD tRRD Bank #0 tAC tAC Read AP* Active Read AP* Bank #2 Idle Bank #3 * AP is the internal precharge start timing - 24 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.5 Interleaved Bank Write (Burst Length = 8) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC RAS tRAS tRP tRAS CAS tRCD tRCD tRCD WE BS0 BS1 A10 RAa A0-A9, A11 RAa RBb CAx RAc CBy RBb RAc CAz DQM CKE DQ ax0 ax1 ax4 ax5 ax6 ax7 by0 by1 tRRD Bank #0 Active Bank #1 Bank #2 Bank #3 by2 by3 by4 by5 by6 by7 CZ0 CZ1 CZ2 tRRD Precharge Write Active Write Active Write Precharge Idle - 25 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.6 Interleaved Bank Write (Burst Length = 8, Auto-precharge) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC RAS tRP tRAS tRAS CAS WE BS0 BS1 tRCD A10 RAa A0-A9, A11 RAa tRCD tRCD RBb CAx RAb CBy RBb RAc CAz DQM CKE ax0 DQ ax1 ax4 ax5 ax6 ax7 by0 by1 AP* Write Active Bank #1 by3 by4 by5 by6 by7 CZ0 CZ1 CZ2 tRRD tRRD Bank #0 Active by2 Write Active Write AP* Bank #2 Idle Bank #3 * AP is the internal precharge start timing - 26 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.7 Page Mode Read (Burst Length = 4, CAS Latency = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK tCCD tCCD tCCD CS tRAS tRAS RAS CAS WE BS0 BS1 tRCD A10 RAa A0-A9, A11 RAa tRCD RBb CAI RBb CBx CAy CAm CBz DQM CKE DQ a0 a1 a2 a3 tAC tAC tAC tAC bx0 tAC Ay0 bx1 Ay1 Ay2 am0 am1 am2 bz0 bz1 bz2 bz3 tRRD Bank #0 Active Read Active Bank #1 Read Read Precharge Read Read AP* Bank #2 Idle Bank #3 * AP is the internal precharge start timing - 27 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.8 Page Mode Read / Write (Burst Length = 8, CAS Latency = 3) 0 1 2 3 5 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRAS RAS CAS WE BS0 BS1 tRCD A10 RAa A0-A9, A11 RAa CAx CAy DQM CKE tAC DQ tWR ax0 Q Q Bank #0 Active ax1 ax3 ax2 Q Q ax5 ax4 Q Q Read ay1 ay0 D D Write ay2 D ay3 D ay4 D Precharge Bank #1 Bank #2 Bank #3 Idle - 28 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.9 Auto-precharge Read (Burst Length = 4, CAS Latency = 3) 0 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC RAS tRAS tRP tRAS CAS WE BS0 BS1 tRCD A10 tRCD RAa A0-A9, A11 RAa RAb CAw RAb CAx DQM CKE tAC DQ tAC aw0 Bank #0 Active Read aw1 AP* aw2 aw3 bx0 Active Read bx1 bx2 bx3 AP* Bank #1 Bank #2 Idle Bank #3 * AP is the internal precharge start timing - 29 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.10 Auto-precharge Write (Burst Length = 4) 0 1 2 3 6 5 4 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS tRC tRC RAS tRAS tRP tRAS tRP CAS WE BS0 BS1 tRCD tRCD A10 RAa A0-A9, A11 RAa RAb CAw RAb RAc CAx RAc DQM CKE DQ aw0 Active Bank #0 Write aw1 aw2 aw3 bx0 AP* Active Write bx1 bx2 bx3 AP* Active Bank #1 Bank #2 Idle * AP is the internal precharge start timing Bank #3 - 30 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.11 Auto Refresh Cycle 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK tRP tRC tRC CS RAS CAS WE BS0,1 A10 A0-A9, A11 DQM CKE DQ All Banks Prechage Auto Refresh Auto Refresh (Arbitrary Cycle) - 31 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.12 Self Refresh Cycle CLK CS tRP RAS CAS WE BS0,1 A10 A0-A9, A11 DQM tCKS tSB CKE tCKS DQ tXSR Self Refresh Cycle All Banks Precharge Self Refresh Entry No Operation / Command Inhibit Self Refresh Exit - 32 - Arbitrary Cycle Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.13 Burst Read and Single Write (Burst Length = 4, CAS Latency = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CLK CS RAS CAS t RCD WE BS0 BS1 A10 RBa A0-A9, A11 RBa CBv CBw CBx CBy CBz aw0 ax0 ay0 az0 az1 az2 az3 D D D Q Q Q Q DQM CKE tAC tAC DQ Bank #0 Active av0 av1 av2 av3 Q Q Q Q Read Single Write Read Bank #1 Bank #2 Idle Bank #3 - 33 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.14 Auto-precharge Timing (Read Cycle) 0 1 Read AP 2 3 4 5 6 7 8 Q5 Q6 9 10 11 (1) CAS Latency =2 ( a ) burst length = 1 Command DQ Act tRP Q0 ( b ) burst length = 2 Command Read AP Act tRP DQ Q0 Q1 ( c ) burst length = 4 Command Read AP Act tRP DQ Q0 Q1 Q2 Q3 Q0 Q1 Q2 Q3 ( d ) burst length = 8 Command Read AP DQ Q4 Act tRP Q7 (2) CAS Latency =3 ( a ) burst length = 1 Command Read AP Act tRP Q0 DQ ( b ) burst length = 2 Command Read AP Act tRP Q0 DQ ( c ) burst length = 4 Command Read Q1 AP Act tRP Q0 DQ Q1 Q2 Q3 ( d ) burst length = 8 Command Read AP Act tRP Q0 DQ Q1 Q2 Q3 Q4 Q5 Q6 Q7 Note ) Read represents the Read w ith Auto precharge command. AP represents the start of internal precharging. Act represents the Bank Activate command. When the Auto precharge command is asserted, the period from Bank Activate command to the start of internal precgarging must be at least t RAS(min). - 34 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.15 Auto-precharge Timing (Write Cycle) 0 1 2 3 4 5 6 7 8 9 10 11 12 CLK (1) CAS Latency = 2 (a) burst length = 1 Command Write AP tWR DQ Act tRP D0 (b) burst length = 2 Command Write AP Act tWR DQ D0 tRP D1 (c) burst length = 4 Command AP Write DQ D0 D1 D2 Act tRP tWR D3 (d) burst length = 8 Command Write AP tWR DQ D0 D1 D2 D3 D4 D5 D6 Act tRP D7 (2) CAS Latency = 3 (a) burst length = 1 Command Write AP Act tWR DQ (b) burst length = 2 Command tRP D0 Write AP Act tWR DQ D0 tRP D1 (c) burst length = 4 Command Write AP Act tWR DQ D0 D1 D2 tRP D3 (d) burst length = 8 Command Write AP tWR DQ D0 D1 D2 D3 D4 D5 D6 Act tRP D7 Note ) Write represents the Write with Auto precharge command. AP represents the start of internal precharing. Act represents the Bank Activ e command. When the /auto precharge command is asserted,the period f rom Bank Activ ate command to the start of intermal precgarging must be at least tRAS (min). - 35 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.16 Timing Chart of Read to Write Cycle In the case of Burst Length = 4 (1) CAS Latency=2 0 1 2 3 4 5 D1 D2 D3 D0 D1 D2 D1 D2 D3 D1 D2 6 7 8 9 10 11 9 10 11 Read Write ( a ) C ommand D QM DQ D0 Read ( b ) C ommand Write D QM DQ D3 (2) CAS Latency=3 Read Write ( a ) C ommand D QM D0 DQ Read ( b ) C ommand Write D QM D0 DQ D3 Note: The Output data must be masked by DQM to avoid I/O conflict 11.17 Timing Chart of Write to Read Cycle In the case of Burst Length=4 0 1 2 3 4 5 6 7 8 Q0 Q1 Q2 Q3 Q0 Q1 Q2 Q3 Q0 Q1 Q2 Q3 Q0 Q1 Q2 (1) CAS Latency=2 ( a ) C ommand Write Read D QM DQ ( b ) C ommand D0 Read Write D QM DQ D0 D1 (2) CAS Latency=3 ( a ) C ommand Write Read D QM DQ ( b ) C ommand D0 Write Read D QM DQ D0 D1 - 36 - Q3 Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.18 Timing Chart of Burst Stop Cycle (Burst Stop Command) 0 1 2 3 4 5 6 7 8 9 10 11 (1) Read cycle ( a ) CAS latency =2 Command Read BST Q0 DQ Q1 Q2 Q0 Q1 Q3 Q4 ( b )CAS latency = 3 Read Command BST DQ Q2 Q3 Q4 (2) W rite cycle Write Command DQ Q0 BST Q1 Q2 Note: Q3 Q4 BST represents the Burst stop command 11.19 Timing Chart of Burst Stop Cycle (Precharge Command) 0 1 2 3 4 5 6 7 8 9 10 11 (1) Read cycle (a) CAS latency =2 Command Read PRCG DQ (b) CAS latency =3 Command Q0 Q1 Q2 Read Q3 Q4 PRCG DQ Q0 Q1 Q2 Q3 Q4 (2) Write cycle Command PRCG Write tWR DQM DQ Q0 Q1 Q2 Q3 Q4 - 37 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.20 CKE/DQM Input Timing (Write Cycle) CLK cy cle No. 1 2 3 D1 D2 D3 4 5 6 7 External CLK Internal CKE DQM DQ D5 DQM MASK D6 CKE MASK (1) CLK cy cle No. 1 2 3 D1 D2 D3 4 5 6 7 External CLK Internal CKE DQM DQ DQM MASK D5 D6 5 6 7 D4 D5 D6 CKE MASK (2) CLK cy cle No. 1 2 3 D1 D2 D3 4 External CLK Internal CKE DQM DQ CKE MASK (3) - 38 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 11.21 CKE/DQM Input Timing (Read Cycle) CLK cy cle No. 1 2 3 4 Q1 Q2 Q3 Q4 5 6 7 External CLK Internal CKE DQM DQ Q6 Open Open (1 ) CLK cy cle No. 1 2 3 Q1 Q2 Q3 4 5 6 7 External CLK Internal CKE DQM DQ Q6 Q4 Open (2 ) CLK cy cle No. 1 2 Q1 Q2 3 4 5 6 7 Q4 Q5 Q6 External CLK Internal CKE DQM DQ Q3 (3 ) - 39 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 12. PACKAGE SPECIFICATION 90 Ball TFBGA (8X13 mm2, Ball pitch:0.8mm, Ø =0.45mm) TOP VIEW BOTTOM VIEW Φb A1 CORNER A1 CORNER 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 A B C D E F G H J K L M N P R E2 E e A B C D E F G H J K L M N P R e D2 D y CONTROL DIMENSIONS ARE IN MILLIMETERS. MILLIMETER SYMBOL SEATING PLANE A1 A Ball Land NOM. MAX. MIN. NOM. MAX. A --- --- 1.20 --- --- 0.047 A1 0.25 --- 0.40 0.010 --- 0.016 D 7.95 8.00 8.05 0.313 0.315 0.317 6.40 BASIC D2 E 12.95 e 13.05 0.40 --0.80 BASIC 0.510 0.512 0.514 0.441 BASIC 0.15 BASIC y Φb 13.0 0.252 BASIC 11.2 BASIC E2 Ball Opening INCH MIN. 0.006 BASIC 0.50 0.016 --- 0.020 0.032 BASIC Note: Ball land: 0.5mm / Ball opening: 0.4mm - 40 - Publication Release Date: Apr. 11, 2011 Revision A01 W9825G2JB 13. REVISION HISTORY VERSION DATE PAGE A01 Apr. 11, 2011 All DESCRIPTION Initial formally data sheet Important Notice Winbond products are not designed, intended, authorized or warranted for use as components in systems or equipment intended for surgical implantation, atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, or for other applications intended to support or sustain life. Further more, Winbond products are not intended for applications wherein failure of Winbond products could result or lead to a situation wherein personal injury, death or severe property or environmental damage could occur. Winbond customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Winbond for any damages resulting from such improper use or sales. - 41 - Publication Release Date: Apr. 11, 2011 Revision A01