SCBS478 − MAY 1993 − REVISED NOVEMBER 1993 • • • • • • • DW OR NT PACKAGE (TOP VIEW) State-of-the-Art BiCMOS Design Significantly Reduces ICCZ ESD Protection Exceeds 2000 V Per MIL-STD-883C, Method 3015; Exceeds 200 V Using Machine Model (C = 200 pF, R= 0) High-Impedance State During Power Up and Power Down 3-State Outputs Drive Bus Lines or Buffer-Memory Address Registers P-N-P Inputs Reduce DC Loading Flow-Through Architecture Optimizes PCB Layout Package Options Include Plastic Small-Outline (DW) Packages and Standard Plastic 300-mil DIPs (NT) OE1 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 GND 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 VCC Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 OE2 description This 10-bit buffer/driver provides high-performance bus interface for wide data paths or buses carrying parity. The 3-state control gate is a 2-input AND gate with active-low inputs so that if either output-enable (OE1 or OE2) input is high, all ten outputs are in the high-impedance state. The outputs are also in the high-impedance state during power-up and power-down conditions. The outputs remain in the high-impedance state while the device is powered down. The SN64BCT29828B is characterized for operation from − 40°C to 85°C and 0°C to 70°C. FUNCTION TABLE INPUTS A OUTPUT Y L L H L H L H X X Z X H X Z OE1 OE2 L L Copyright 1993, Texas Instruments Incorporated !"#$%! & '("")% $& ! *(+,'$%! -$%). "!-('%& '!!"# %! &*)''$%!& *)" %/) %)"#& ! )0$& &%"(#)%& &%$-$"- 1$""$%2. "!-('%! *"!')&&3 -!)& !% )')&&$",2 ',(-) %)&%3 ! $,, *$"$#)%)"&. • DALLAS, TEXAS 75265 • HOUSTON, TEXAS 77251−1443 POST OFFICE BOX 655303 POST OFFICE BOX 1443 3−1 SCBS478 − MAY 1993 − REVISED NOVEMBER 1993 logic symbol† 1 OE1 OE2 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 logic diagram (positive logic) OE1 & 2 3 OE2 EN 13 1 23 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 A1 1 13 2 23 Y1 Y1 Y2 Y3 To Nine Other Channels Y4 Y5 Y6 Y7 Y8 Y9 Y10 † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Voltage range applied to any output in the disabled or power-off state, VO . . . . . . . . . . . . . . . . −0.5 V to 5.5 V Voltage range applied to any output in the high state, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 5.5 V Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed. recommended operating conditions (see Note 2) VCC VIH Supply voltage VIL IIK Low-level input voltage IOH IOL High-level input voltage NOM MAX 4.5 5 5.5 2 UNIT V V 0.8 V Input clamp current −18 mA High-level output current −24 mA 48 mA 85 °C Low-level output current TA Operating free-air temperature NOTE 2: Unused or floating inputs must be held high or low. 3−2 MIN −40 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • SCBS478 − MAY 1993 − REVISED NOVEMBER 1993 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH VOL TEST CONDITIONS VCC = 4.5 V, MIN II = − 18 mA IOH = − 15 mA VCC = 4.5 V IOH = − 24 mA IOH = − 3 mA VCC = 4.75 V, VCC = 4.5 V, TYP† 2.4 3.3 2 3.1 MAX UNIT −1.2 V V 2.7 IOL = 48 mA 0.42 IOZ VCC = 0 to 2.3 V (power up) VCC = 1.8 V to 0 (power down) VO = 2.7 V or 0.5 V, IOZH IOZL VCC = 5.5 V, VCC = 5.5 V, VO = 2.7 V VO = 0.5 V II IIH VCC = 5.5 V, VCC = 5.5 V, IIL IOS‡ 0.5 ± 50 OE at 0.8 V ± 50 V µA A 20 µA −20 µA VI = 7 V VI = 2.7 V 0.1 mA 20 µA VCC = 5.5 V, VCC = 5.5 V, VI = 0.5 V VO = 0 −0.2 mA ICCL ICCH VCC = 5.5 V, VCC = 5.5 V, Outputs open ICCZ Ci VCC = 5.5 V, VCC = 5 V, −75 −250 mA 28 40 mA Outputs open 15 25 mA Outputs open 3.5 6 mA VI = 2.5 V to 0.5 V VO = 2.5 V to 0.5 V 4.5 pF 7 pF Co VCC = 5 V, † All typical values are at VCC = 5 V, TA = 25°C. ‡ Not more than one output should be tested at a time, and the duration of the test should not exceed one second. switching characteristics over recommended range of supply voltage, CL = 50 pF (unless otherwise noted) (see Note 3) FROM (INPUT) TO (OUTPUT) tPLH tPHL A Y tPZH tPZL OE Y tPHZ tPLZ OE Y PARAMETER VCC = 5 V, TA = 25°C TA = − 40°C to 85°C TA = 0°C to 70°C MIN TYP MAX MIN MAX MIN MAX 1 3.3 5.2 1 6.3 1 5.9 1 5.1 4.2 1 4.9 1 4.5 2 5.3 7.7 2 9.2 2 8.6 2 8.5 10.2 2 12.7 2 11.9 2 5.4 7.6 2 9.4 2 8.7 2 5.1 6.8 2 9 2 8.1 UNIT ns ns ns NOTE 3: Load circuits and voltage waveforms are shown in Section 1. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 3−3 SCBS478 − MAY 1993 − REVISED NOVEMBER 1993 3−4 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated