EMERSON-NETWORKPOWER NLP150L

NLP150L Series
Single and triple outputs
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 1
•
•
•
•
•
•
•
•
•
•
•
90 Vac to 264 Vac universal input range
Provides low voltage outputs of 3.3 V
EN61000-3-2 compliant
Overvoltage and short circuit protection
Power fail detection
Current sharing (on VA and VB)
3.8 x 6.8 x 1.26 inches
UL, CSA and VDE safety approvals and CE-marked to LVD
Compliance to EN55022-B conducted noise standard
Compliance to EN55022-A radiated noise standard
Meets all applicable and relevant immunity standards
EN61000-4-2, -3, -4, -5 and -6
• Available RoHS compliant
The NLP150L series of 150 Watt ac-dc open-frame power supplies are available with
single, triple or quad outputs. The single and triple output versions described in this
datasheet are housed in a 3.8 x 6.8 x 1.26 inch package. All NLP150L series power
supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support
current sharing. The power supplies are designed for use in 1U shelves or boxes, and are
primarily intended for networking applications that have a heavy logic content, such as
access concentrators, midrange routers, LAN switches and shared media hubs.
Patent No. 5600546 and 5652700
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS (continued)
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Turn-on delay
@ 120 Vac Input
2.0 s, max.
Transient response
Main output
75% to 100%
step at 0.1 A/µs
5.0% or 250 mV
max. dev., 1 ms max.
recovery to 1%
Temperature coefficient
Overvoltage protection
±0.02%/°C
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
Singles and multiple
125%, ±10%
Continuous
See table
Universal input
90-264 Vac
Input frequency range
47-63 Hz
Input surge current
264 Vac (cold start)
Safety ground
leakage current
264 Vac, 60 Hz
Input current
120 Vac @ 150 W
230 Vac @ 150 W
Input fuse
UL/IEC127
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level
Level
Level
Level
40 A max.
Hold-up time
120 Vac @ 60 Hz
20 ms @ 150 W
Efficiency (See Note 13)
120 Vac @ 150 W
73% typical
Isolation voltage
Input/output
Input/chassis
Approvals and
standards pending
MTBF (@ 25 °C)
3000 Vac
1500 Vac
EN60950, VDE0805, IEC950
UL1950, CSA C22.2 No. 950
Thermal performance
1.95 A rms
1.10 A rms
F3.15A H, 250 Vac
(10)
EN61000-4-2
EN61000-4-2
Level B
Level A
Compliant
Level 3
Level 3
540 g (19 oz)
MIL-HDBK-217F
Bellcore
ENVIRONMENTAL SPECIFICATIONS
0.99 mA
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
3
3
3
3
GENERAL SPECIFICATIONS
Weight
INPUT SPECIFICATIONS
Input voltage range
(See Note 12)
Surge
Fast transients
Radiated immunity
Conducted immunity
(10)
350,000 hours min.
800,000 hours min.
(8)
Operating ambient,
0 °C to +50 °C
(See derating curve)
Non-operating
-40 °C to +85 °C
50 °C to 70 °C ambient,
Derate to
convection cooled
50% load
0 °C to 50 °C ambient,
110 W
convection cooled
0 °C to 50 °C ambient,
150 W
300 LFM forced air
Peak (0 °C to +50 °C)
(See Note 3)
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 6)
5-500 Hz
Shock
per MIL-STD-810E
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms peak
516.4 Part IV
File Name: nlp150lst.pdf Rev (03): 08 Nov 2005
NLP150L Series
Single and triple outputs
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
RIPPLE
MIN
(5)
MAX
(1)
300 LFM
TOTAL
(4)
(2)
REGULATION
MODEL
NUMBERS
(14,15)
3.3 V (VA)
1A
22 A
30 A
50 mV
±2.0%
NLP150L-96S3J
5.1 V (VA)
1A
22 A
30 A
50 mV
±2.0%
NLP150L-96S5J
+12 V (VA)
0.3 A
9.2 A
12.5 A
120 mV
±2.0%
NLP150L-96S6J
24 V (VA)
0.15 A
4.6 A
6.5 A
240 mV
±2.0%
NLP150L-96S8J
48 V (VA)
0.1 A
2.3 A
3.2 A
480 mV
±2.0%
NLP150L-96S9J
+5.1 V (VA)
1.5 A
20 A
30 A
50 mV
±2.0%
NLP150L-96T536J
+3.3 V (VB)
0.5 A
10 A
15 A
50 mV
±2.0%
+12 V (VC)
0A
2A
3A
120 mV
±5.0%
+12 V (VA)
0.6 A
9.2 A
12.5 A
120 mV
±2.0%
+5.1 V (VB)
0.5 A
6A
8A
50 mV
±2.0%
+24 V (VC)
0A
2A
3A
240 mV
±5.0%
NLP150L-96T658J
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Free air convection.
Multiple output units: maximum continuous output power not to exceed
110 W and the output current not to exceed: IA+IB+2(IC)≤23 A.
300 LFM forced air cooling from the longer side.
Multiple output units: maximum continuous output power not to exceed
150 W and the output current not to exceed: IA+IB+2(IC)≤32 A.
Peak power at 115% lasting less than 30 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for room temperature rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch
twisted pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF
ceramic capacitor.
Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum load
on main output will not allow the supply to start-up correctly. Some
electronic test loads have a large delay time before they start drawing
current even though the voltage from the supply is present. During this time
delay, there is no load on the output and as a result, the supply may not be
able to start-up properly and maintain its correct output voltage. In these
instances, a dummy resistive load across the output may be necessary to
load the output of the supply until the test load can function correctly and
draw the intended minimum load. Minimum load required on auxiliary
outputs to maintain regulation.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
For optimum reliability no part of the heatsink should exceed 110 °C and
no semi-conductor case temperature should exceed 115 °C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Conducted EMI specifications reference measurements made with the
power supply mounted on a grounded metal sheet extending 1 inch
beyond each edge, using an unshielded cable. No external filtering required
during conducted emissions testing but some applications may require
additional filtering to achieve system compliance. Compliance with
Radiated EMI specifications may require mounting in a suitable enclosure.
All models require a minimum mounting stand-off of 6.35 mm (0.25 inches)
in the end use product.
Operational range 90 Vac to 264 Vac.
For 3.3 V ouput (single), typical efficiency is 69%.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
150W
110W
300 LFM FORCED
AIR COOLING
NATURAL
CONVECTION
COOLING
0°C
75W
55W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-0162
Licence No. 123897
UL1950 File No. E136005
File Name: nlp150lst.pdf Rev (03): 08 Nov 2005
NLP150L Series
Single and triple outputs
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
1
6.800 (172.72)
6.450 (163.83)
0.175 (4.45)
3.925 (99.70)
4
3
J2
J3
1
2
3.450 (87.63)
J5
Recommended direction
for forced air relative to
power supply orientation
shown below.
T1 (REF.)
1
3
J1
5
F1
J6
Ø0.156 (Ø3.96)
1
2
1
2
3
4
0.175 (4.45)
(5 PLS)
JCS
JRM3
JRM5
2
3.800 (96.52)
1
2
1
2
1
2
1
Best.
Good.
Not recommended.
Not recommended.
ALL DIMENSIONS IN INCHES (MM)
MAXIMUM COMPONENT HEIGHT 1.26 (32.00)
CONNECTOR
TYPE
CONNECTOR AND MATING CONNECTOR TYPES
MATING CONNECTOR TYPE
J1
Molex 26-60-4030 or equivalent
J2
J3
Male 0.250 quick disconnect
Molex 26-60-4040 or equivalent
J5
Beau Interconnect 70505-C-50 or
equivalent
Molex 22-23-3021 or equivalent
Leoco 2421P02H000 or equivalent
J6
JRM3, JRM5
& JCS
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminals
Molex AA-5261, AA22-01 or equivalent
Molex 09-50-3021 or equivalent with Molex 2478 phosphor bronze
or equivalent crimp terminals
N/A
Molex 22-01-2021 and contact 08-50-0113 terminals or equivalent
Leoco 2420S02000 and contact 2453TPB00V1
J1 PIN CONNECTIONS
Pin 1
Neutral
Pin 2
Void
Pin 3
Line
J3 PIN CONNECTIONS
Pin 1
VD Positive
Pin 2
VD RTN
J5 PIN CONNECTIONS
Pin 1
VA Positive
Pin 2
VA Positive
Pin 3
Main RTN
Pin 4
Main RTN
Pin 5
VB Positive
JRM5 PIN CONNECTIONS
Pin 1
Pin 2
VA Sense +
VA Sense -
Note: VD is a floating output.
It can be configured as positibe or negative
J6 PIN CONNECTIONS
Pin 1
Signal
Pin 2
RTN
JCS PIN CONNECTIONS
Pin 1 Load A Current Sharing
Pin 2 Load B Current Sharing
JRM3 PIN CONNECTIONS
Pin 1
Pin 2
VB Sense +
VB Sense -
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note
www.artesyn.com
File Name: nlp150lst.pdf Rev (03): 08 Nov 2005