NLP150L Series Single and triple outputs LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 1 • • • • • • • • • • • 90 Vac to 264 Vac universal input range Provides low voltage outputs of 3.3 V EN61000-3-2 compliant Overvoltage and short circuit protection Power fail detection Current sharing (on VA and VB) 3.8 x 6.8 x 1.26 inches UL, CSA and VDE safety approvals and CE-marked to LVD Compliance to EN55022-B conducted noise standard Compliance to EN55022-A radiated noise standard Meets all applicable and relevant immunity standards EN61000-4-2, -3, -4, -5 and -6 • Available RoHS compliant The NLP150L series of 150 Watt ac-dc open-frame power supplies are available with single, triple or quad outputs. The single and triple output versions described in this datasheet are housed in a 3.8 x 6.8 x 1.26 inch package. All NLP150L series power supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support current sharing. The power supplies are designed for use in 1U shelves or boxes, and are primarily intended for networking applications that have a heavy logic content, such as access concentrators, midrange routers, LAN switches and shared media hubs. Patent No. 5600546 and 5652700 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 °C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS (continued) Total regulation (Line and load) Main output Auxiliary outputs ±2.0% ±5.0% Turn-on delay @ 120 Vac Input 2.0 s, max. Transient response Main output 75% to 100% step at 0.1 A/µs 5.0% or 250 mV max. dev., 1 ms max. recovery to 1% Temperature coefficient Overvoltage protection ±0.02%/°C Main outputs Short circuit protection Cyclic operation Minimum output current Singles and multiple 125%, ±10% Continuous See table Universal input 90-264 Vac Input frequency range 47-63 Hz Input surge current 264 Vac (cold start) Safety ground leakage current 264 Vac, 60 Hz Input current 120 Vac @ 150 W 230 Vac @ 150 W Input fuse UL/IEC127 EMC CHARACTERISTICS Conducted emissions Radiated emissions Harmonic current emission correction ESD air ESD contact EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 Level Level Level Level 40 A max. Hold-up time 120 Vac @ 60 Hz 20 ms @ 150 W Efficiency (See Note 13) 120 Vac @ 150 W 73% typical Isolation voltage Input/output Input/chassis Approvals and standards pending MTBF (@ 25 °C) 3000 Vac 1500 Vac EN60950, VDE0805, IEC950 UL1950, CSA C22.2 No. 950 Thermal performance 1.95 A rms 1.10 A rms F3.15A H, 250 Vac (10) EN61000-4-2 EN61000-4-2 Level B Level A Compliant Level 3 Level 3 540 g (19 oz) MIL-HDBK-217F Bellcore ENVIRONMENTAL SPECIFICATIONS 0.99 mA EN55022, FCC part 15 EN55022, FCC part 15 EN61000-3-2 3 3 3 3 GENERAL SPECIFICATIONS Weight INPUT SPECIFICATIONS Input voltage range (See Note 12) Surge Fast transients Radiated immunity Conducted immunity (10) 350,000 hours min. 800,000 hours min. (8) Operating ambient, 0 °C to +50 °C (See derating curve) Non-operating -40 °C to +85 °C 50 °C to 70 °C ambient, Derate to convection cooled 50% load 0 °C to 50 °C ambient, 110 W convection cooled 0 °C to 50 °C ambient, 150 W 300 LFM forced air Peak (0 °C to +50 °C) (See Note 3) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 6) 5-500 Hz Shock per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV File Name: nlp150lst.pdf Rev (03): 08 Nov 2005 NLP150L Series Single and triple outputs LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT VOLTAGE RIPPLE MIN (5) MAX (1) 300 LFM TOTAL (4) (2) REGULATION MODEL NUMBERS (14,15) 3.3 V (VA) 1A 22 A 30 A 50 mV ±2.0% NLP150L-96S3J 5.1 V (VA) 1A 22 A 30 A 50 mV ±2.0% NLP150L-96S5J +12 V (VA) 0.3 A 9.2 A 12.5 A 120 mV ±2.0% NLP150L-96S6J 24 V (VA) 0.15 A 4.6 A 6.5 A 240 mV ±2.0% NLP150L-96S8J 48 V (VA) 0.1 A 2.3 A 3.2 A 480 mV ±2.0% NLP150L-96S9J +5.1 V (VA) 1.5 A 20 A 30 A 50 mV ±2.0% NLP150L-96T536J +3.3 V (VB) 0.5 A 10 A 15 A 50 mV ±2.0% +12 V (VC) 0A 2A 3A 120 mV ±5.0% +12 V (VA) 0.6 A 9.2 A 12.5 A 120 mV ±2.0% +5.1 V (VB) 0.5 A 6A 8A 50 mV ±2.0% +24 V (VC) 0A 2A 3A 240 mV ±5.0% NLP150L-96T658J Notes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Free air convection. Multiple output units: maximum continuous output power not to exceed 110 W and the output current not to exceed: IA+IB+2(IC)≤23 A. 300 LFM forced air cooling from the longer side. Multiple output units: maximum continuous output power not to exceed 150 W and the output current not to exceed: IA+IB+2(IC)≤32 A. Peak power at 115% lasting less than 30 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor. Minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. Failure to observe minimum load on main output will not allow the supply to start-up correctly. Some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. During this time delay, there is no load on the output and as a result, the supply may not be able to start-up properly and maintain its correct output voltage. In these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. Minimum load required on auxiliary outputs to maintain regulation. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. For optimum reliability no part of the heatsink should exceed 110 °C and no semi-conductor case temperature should exceed 115 °C. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Conducted EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. Compliance with Radiated EMI specifications may require mounting in a suitable enclosure. All models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. Operational range 90 Vac to 264 Vac. For 3.3 V ouput (single), typical efficiency is 69%. The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. DERATING CURVE Output Power (Watts) 150W 110W 300 LFM FORCED AIR COOLING NATURAL CONVECTION COOLING 0°C 75W 55W 10°C 20°C 30°C 40°C 50°C 60°C 70°C International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. 10401-3336-0162 Licence No. 123897 UL1950 File No. E136005 File Name: nlp150lst.pdf Rev (03): 08 Nov 2005 NLP150L Series Single and triple outputs LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm Mechanical Notes A All dimensions are in inches (mm). 1 6.800 (172.72) 6.450 (163.83) 0.175 (4.45) 3.925 (99.70) 4 3 J2 J3 1 2 3.450 (87.63) J5 Recommended direction for forced air relative to power supply orientation shown below. T1 (REF.) 1 3 J1 5 F1 J6 Ø0.156 (Ø3.96) 1 2 1 2 3 4 0.175 (4.45) (5 PLS) JCS JRM3 JRM5 2 3.800 (96.52) 1 2 1 2 1 2 1 Best. Good. Not recommended. Not recommended. ALL DIMENSIONS IN INCHES (MM) MAXIMUM COMPONENT HEIGHT 1.26 (32.00) CONNECTOR TYPE CONNECTOR AND MATING CONNECTOR TYPES MATING CONNECTOR TYPE J1 Molex 26-60-4030 or equivalent J2 J3 Male 0.250 quick disconnect Molex 26-60-4040 or equivalent J5 Beau Interconnect 70505-C-50 or equivalent Molex 22-23-3021 or equivalent Leoco 2421P02H000 or equivalent J6 JRM3, JRM5 & JCS Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals Molex AA-5261, AA22-01 or equivalent Molex 09-50-3021 or equivalent with Molex 2478 phosphor bronze or equivalent crimp terminals N/A Molex 22-01-2021 and contact 08-50-0113 terminals or equivalent Leoco 2420S02000 and contact 2453TPB00V1 J1 PIN CONNECTIONS Pin 1 Neutral Pin 2 Void Pin 3 Line J3 PIN CONNECTIONS Pin 1 VD Positive Pin 2 VD RTN J5 PIN CONNECTIONS Pin 1 VA Positive Pin 2 VA Positive Pin 3 Main RTN Pin 4 Main RTN Pin 5 VB Positive JRM5 PIN CONNECTIONS Pin 1 Pin 2 VA Sense + VA Sense - Note: VD is a floating output. It can be configured as positibe or negative J6 PIN CONNECTIONS Pin 1 Signal Pin 2 RTN JCS PIN CONNECTIONS Pin 1 Load A Current Sharing Pin 2 Load B Current Sharing JRM3 PIN CONNECTIONS Pin 1 Pin 2 VB Sense + VB Sense - Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: ✔ Application Note www.artesyn.com File Name: nlp150lst.pdf Rev (03): 08 Nov 2005