ARTESYN NLP70

NLP70 Series
Triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70W AC/DC Universal Input Switch Mode Power Supplies
•
•
•
•
•
•
•
•
1
Provides up to 10.5A on either 3.3V or 5V
5.5 x 3.0 inch card and 1.26 inch package (1U applications)
3.3V, 5V and 12V triple
EN61000-3-2 compliant
Overvoltage and short circuit protection
EN55022, EN55011 conducted emissions level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
Mounting holes as per NLP65 series, easy upgrade
The NLP70-9693 is a 70W (with forced air) universal input AC/DC power supply on a
5.5 x 3 inch card with a maximum component height of 1.26 inches for use in 1U
applications. The model has input harmonic current correction making the series ideal
for product designs that need to comply with EN61000-3-2 legislation. The NLP70
provides 52.5W of output power with free air convection cooling which can be boosted
to 70W with 20CFM of air. The NLP70, with full international safety approval and the CE
mark, meets conducted emissions EN55022 level B and has immunity compliance to
EN61000-4-2, -3, -4, -5, -6. The NLP70 series is designed for use in low power data
networking, computer and telecom applications using 3.3V or 5V logic. The NLP70 can
provide the same current on either the 3.3V or 5V channel making it ideal for
applications using a mixture of 3.3V and 5V logic or for applications in transition from
5V to 3.3V logic.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
(line and load)
3.3V and 5V
12V
Rise time
At turn-on
Transient response
Main output
25% step
at 0.1A/µs
±2.0%
±5.0%
1.0s, max.
5.0% or 250mV
max. dev., 1ms max.
recovery to 1.0%
Temperature coefficient
±0.02%/°C
Overvoltage protection
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
125%, ±10%
Continuous
(See Note 6)
Universal input
Input frequency range
90 to 264VAC
47Hz to 63Hz
Input surge current
(cold start)
120VAC
230VAC
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
Input current
120VAC, with PFC
230VAC, with PFC
Input fuse
UL/IEC127
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
120VAC @ 60Hz
230VAC @ 50Hz
Efficiency
120VAC, 65W
70% typical
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Fixed
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
300g (10.7 oz)
MIL-HDBK-217F
150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 1, 2, 3, 11)
Operating ambient,
0°C to +70°C
(See derating curve)
Non-operating
-40°C to +85°C
50°C to 70°C ambient,
Derate to
convection cooled
50% load
0°C to 50°C ambient,
52.5W
convection cooled
0°C to 50°C ambient,
70W
20CFM forced air (See Note 10)
Peak (0°C to +50°C, 60s)
See table
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 5)
5Hz to 500Hz
Shock
per MIL-STD-810E
0.7mA
1.4mA
1.05A rms
0.55A rms
250VAC S 3.15A
Level B
Level A
EN60950, VDE0805
IEC950, UL1950
CSA C22.2 No. 950
Weight
17A max.
32A max.
(10)
16ms @ 55W
78ms @ 55W
100kHz, ±5kHz
Approvals and
standards
(See Notes 8, 9)
MTBF
INPUT SPECIFICATIONS
Input voltage range
Hold-up time
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4G rms peak
516.4 Part IV
File Name: NLP70.PDF Rev: 26 Mar 2001
NLP70 Series
Triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
RIPPLE
TYP.
(1)
AIR
(2)
PEAK
10.5A
13A
14A
50mV
±2.0%
+3.3V (IB)
10.5A
13A
14A
50mV
±2.0%
(12)
0.65A
0.8A
0.8A
120mV
±5.0%
Notes
N
1
9
3
4
5
6
7
8
Free air convection cooling.
I5 = 10.5A max.; I3.3 = 10.5A max.; I3.3 + I5 < 10.6A; Po = 52.5W max.
20CFM forced air.
I3.3 = 13A max.; I5.5 = 13A max.; I3.3 + I5 < 15A; Po = 70W max.
Peak output current lasting less than 60 seconds with duty cycle less
than 5%. During peak loading, output voltage may exceed total
regulation limits.
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20MHz bandwidth using a 6 inch
twisted pair, terminated with a 10µF electrolytic capacitor and a 0.1µF
ceramic capacitor.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
To maintain stated regulation then:
I12 / I(A) ≤ 2 and I(A) ≥ 0.1A.
For optimum reliability, no part of the heatsink should exceed 120˚C, and
no semiconductor case temperature should exceed 130˚C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Line
Pin 2
No Pin
Pin 3
AC Neutral
J2
Pin 1
Safety Ground
OUTPUT PIN CONNECTIONS
J5
FUNCTION
Pin 1
3.3V
Pin 2
3.3V
Pin 3
Return
Pin 4
Return
Pin 5
Return
Pin 6
5V
Pin 7
5V
J3
FUNCTION
Pin 1
12V Return
Pin 2
12V (12)
MODEL
REGULATION
+5V (IA)
+12V
2
TOTAL
(4)
(3)
(6)
NUMBER
NLP70-9693
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
10 Conducted and radiated emissions testing were performed using the
standard EN55022 set-up with a stand alone NLP70-9693 unit placed on
a grounded metal plate with a line choke on the AC input and ground
wires (i.e. the wires are looped through an EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’
AC inlet with an integral line filter in the system chassis or to install a line
choke on the input wires as close as possible to AC entry point of the
system chassis. Please contact the applications group at Artesyn for
assistance with EMI compliance.
11 All models require a minimum mounting stand-off of 0.25 inches
(6.35mm) in the end use product.
12 12V is a floating output and can be referenced negative or positive.
DERATING CURVE
Output Power (Watts)
70W
20CFM FORCED AIR COOLING
52.5W
NATURAL
CONVECTION
COOLING
0˚C
35W
26W
10˚C 20˚C 30˚C 40˚C 50˚C 60˚C
70˚C
www.artesyn.com
File Name: NLP70.PDF Rev: 26 Mar 2001
NLP70 Series
Triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 70W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J3) connector type
Molex 26-60-4020 type.
DC (J3) mating connector type
Molex 09-50-3021 with Molex 2478 phosphor
bronze crimp terminals or equivalent.
DC (J5) connector type
Molex 26-60-4070 type.
DC (J5) mating connector type
Molex 09-50-3071 with Molex phosphor
bronze crimp terminals or equivalent.
Note: The input and output connectors are the same as those
used on NFS40, NAL40, NAN40, NLP40 and NLP65.
Earth (J2) connector type
Male 0.250 quick disconnect type.
Earth (J2) mating connector type
Molex 90028.
5.50
(139.70)
0.225
(5.715)
4.550
(115.57)
J1
3
N
1
L
J5
7
3.00
(76.20)
1
2.550
(64.770)
T1
J3
C19
2
1
J2
Mounting
Hole Diameter
0.156 (4.00)
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE: .xxx ± 0.005"
.xx ± 0.02"
ALL DIMENSIONS IN INCHES (mm)
International Safety Standard Approvals
VDE0805/EN60950/IEC950
UL1950 approval pending
CSA C22.2 No. 950 approval pending
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP70.PDF Rev: 26 Mar 2001