ARTESYN NLP65

NLP65 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
•
65-75W AC/DC Universal Input Switch Mode Power Supplies
1
5.0 x 3.0 inch card and 1.26 inch package (1U applications)
Smallest industry standard package
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
65W with free air convection cooling
EN55022, EN55011 conducted emissions level B
EN61000-4-2,-3,-4, -5, -6 immunity compliant
Enclosure and cover kit options
The NLP65 series is a 65W universal input AC/DC power supply on a 5 x 3 inch card with a
maximum component height of 1.26 inches for use in 1U applications. Each model has the option
of input harmonic current correction in the same package size making the series ideal for product
designs that will need to comply with EN61000-3-2 legislation. The NLP65 provides 65W of
output power with free air convection cooling which can be boosted to 75W with 20CFM of air.
The NLP65, with full international safety approval and the CE mark, meets conducted emissions
EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The series is
available in a factory installed enclosure with an IEC connector and output connector on flying
leads plus a cover kit for self-installation is also available as an accessory. The NLP65 series is
designed for use in low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, internet servers, cable modems and PABX’s. This list is not exclusive as
the generic feature set of the NLP65 series with industry standard output configurations provides
a solution for most low power applications including many industrial applications.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS (continued)
Total regulation
(Line and load)
Main output
Auxiliary outputs
Rise time
At turn-on
Transient response
Main output
25% step
at 0.1A/µs
±2.0%
±5.0%
1.0s, max.
5.0% or 250mV
max. dev., 1ms max.
recovery to 1%
Temperature coefficient
±0.02%/°C
Overvoltage protection
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
Single and multiple
125%, ±10%
(See Note 6)
Universal input,
(See Note 2)
NLP65-76xx
version only
Input frequency range
120VAC
230VAC
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
Input current
120VAC,
230VAC,
120VAC,
230VAC,
Input fuse
UL/IEC127
EMC CHARACTERISTICS
17A max.
32A max.
with PFC
with PFC
without PFC
without PFC
1.05A
0.51A
1.40A
0.80A
Perf.
Perf.
Perf.
Perf.
criteria
criteria
criteria
criteria
1
1
2
2
120VAC, 60Hz
230VAC, 50Hz
16ms @ 65W
78ms @ 65W
Efficiency
120VAC, 65W
72% typical
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Fixed
100kHz, ±5kHz
Approvals and
standards
(See Notes 9, 13)
MTBF
EN60950, VDE0805
IEC950, UL1950, BABT
CSA C22.2 No. 950
283g (10 oz)
MIL-HDBK-217F
150,000 hours min.
GENERAL SPECIFICATIONS
Thermal performance
(See Notes 1, 3, 10)
rms
rms
rms
rms
250VAC S 3.15A
Level B
Level A
Perf. criteria 1
Perf. criteria 1
3
3
3
3
Hold-up time
0.7mA
1.4mA
(11,12)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
level
level
level
level
Weight
120 to 370VDC
47Hz to 63Hz
Input surge current
(cold start)
Conducted emissions
Radiated emissions
ESD air
ESD contact
85 to 264VAC
EN61000-4-5,
EN61000-4-4,
EN61000-4-3,
EN61000-4-6,
GENERAL SPECIFICATIONS
Continuous
INPUT SPECIFICATIONS
Input voltage range
Surge
Fast transients
Radiated immunity
Conducted immunity
(11,12)
Operating ambient,
0°C to +70°C
(See derating curve)
Non-operating
-40°C to +85°C
50°C to 70°C ambient,
Derate to
convection cooled
50% load
0°C to 50°C, ambient,
65W
convection cooled
0°C to 50°C ambient,
75W
20CFM forced air (See Note 10)
Peak (0°C to +50°C, 60s)
See table
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 5)
5Hz to 500Hz
Shock
per MIL-STD-810E
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4G rms peak
516.4 Part IV
File Name: NLP65.PDF Rev: 15 Jan 2002
NLP65 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
65-75W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
+5V (IA)
RIPPLE
MAX
(1)
7.5A
PEAK
(3)
FAN
TOTAL
(4)
(10)
REGULATION
9.1A
8.0A
50mV
±2.0%
+12V (IB)
2.5A
3.3A
3.0A
150mV
±5.0%
–12V
0.65A
0.81A
0.8A
120mV
±5.0%
+5V (IA)
7.5A
9.1A
8.0A
50mV
±2.0%
+15V (IB)
2.2A
2.9A
2.5A
150mV
±5.0%
–15V
0.65A
0.85A
0.8A
150mV
±5.0%
+5V (IA)
7.0A
9.1A
8.0A
50mV
±2.0%
+24V (IB)
2.0A
2.6A
2.0A
240mV
±5.0%
+5V (IA)
7.0A
9.1A
8.0A
50mV
±2.0%
6
7
8
GROUND
NLP65-7608
NLP65-9608
NLP65-X608G
NLP65-7610
NLP65-9610
NLP65-X610G
NLP65-7620
NLP65-9620
NLP65-X620G
NLP65-7629
NLP65-9629
NLP65-X629G
PIN
(12, 14)
2.5A
3.3A
3.0A
150mV
±5.0%
13.0A
12.0A
50mV
±2.0%
NLP65-7605
NLP65-9605
NLP65-X605G
+12V
5.4A
7.0A
6.5A
120mV
±2.0%
NLP65-7612
NLP65-9612
NLP65-X612G
+15V
4.4A
5.7A
5.3A
150mV
±2.0%
NLP65-7615
NLP65-9615
NLP65-X615G
+24V
2.7A
3.5A
3.5A
240mV
±2.0%
NLP65-7624
NLP65-9624
NLP65-X624G
9
5
CORRECTED
10.0A
1
4
HARMONIC
CORRECTED
+5V
N
3
NON-HARMONIC
+12V (IB)
Notes
2
(6)
Natural convection cooling. Models NLP65-X629, NLP65-X608, NLP65X610 must not exceed 62.5 Watts continuous output power with natural
convection. Model NLP65-X620 not to exceed 65 Watts continuous output
power with natural convection. Model NLP65-763V3 must not exceed 33
Watts continuous output power.
When the input voltage is less than 90VAC the operating temperature
range is 0°C to +40°C. The ripple and regulation specifications may not be
met.
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20MHz bandwidth using a 6 inch twisted
pair, terminated with a 10µF electrolytic capacitor and a 0.1µF ceramic
capacitor.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
A minimum load on the main output is required for proper start up. For
multiple outputs and single +5V output, the minimum load on the +5V is
0.2A. For single outputs greater than +5V the minimum load is 0.1A. To
maintain stated regulation then:
for single output units
I ≥ 0.2A
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2A.
For optimum reliability, no part of the heatsink should exceed 120oC, and
no semiconductor case temperature should exceed 130oC.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
International Safety Standard Approvals
10
11
12
13
14
15
Model Numbering Options
1
VDE0805/EN60950/IEC950 File No. 10401-3336-1096
Licence No. 93678
UL1950 File No. E136005
2
CSA C22.2 No. 950 File No. LR41062C
Approval No. 606975
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Maximum continuous output power for all multiple output models must not
exceed 75 Watts with 20CFM forced air cooling.
Conducted and radiated emissions testing were performed using the
standard EN55022 set-up with a stand alone NLP65 unit placed on a
grounded metal plate with a line choke on the AC input and ground wires
(i.e. the wires are looped through an EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’
AC inlet with an integral line filter in the system chassis or to install a line
choke on the input wires as close as possible to AC entry point of the
system chasssis. Please contact the applications group at Artesyn for
assistance with EMI compliance.
The NLP65 units with the suffix ‘G’ is the ground pin and ground choke
option. J2, L6 and JP10 are included. J2 is a safety agency approved
grounding pin, L6 is a ground choke and JP10 is a jumper. This option is
intended for use in non-metallic chassis applications where grounding is
not possible via the mounting screws. The ground choke is provided to
assist system EMC compliance. When performing conducted emissions
testing on stand alone units, the ‘G’ option is required to meet level B. To
order simply add the suffix ‘G’ to the standard model number, e.g. NLP657608G, NLP65-9608G. This option is available for both the PFC and nonPFC versions.
All models require a minimum mounting stand-off of 0.25 inches (6.35mm)
in the end use product.
These standard models are available with an enclosure. To order an
enclosed version, see model numbering options below.
No PFC version, EN61000-3-2 is not applicable to this model.
3
4
The enclosure version includes: IEC connector, on/off switch, wire harness
output connector and fitted cover. To order, please add the suffix ‘E’ to the
end of the model number, e.g. NLP65-X608E. See NLP65 enclosure for
details.
A Safety earth ground pin and ground choke are available as an option.
To order, please add the suffix ‘G’ to the end of the model number, e.g.
NLP65-X608G.
To order a snap-on cover (unfitted), order the part number NLP65C.
To order a mounting bracket (unfitted), order the part number NLP65MB.
www.artesyn.com
File Name: NLP65.PDF Rev: 15 Jan 2002
NLP65 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
65-75W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
5.00
(127.00)
4.550
(115.57)
0.225
(5.715)
J1
J3
3
N
1
L
1
3.00
(76.20)
6
2.550
(64.770)
T1
J2
C19
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE: .xxx ± 0.005"
.xx ± 0.02"
Mounting
Hole Diameter
0.156 (4.00)
ALL DIMENSIONS IN INCHES (mm)
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Line
Pin 2
No Pin
Pin 3
AC Neutral
J2 (ON ‘G’ SUFFIX ONLY)
Pin 1
Safety Ground
J3
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
OUTPUT PIN CONNECTIONS
SINGLE -XX05 ONLY
SINGLE
V (A)
No Connection
V (A)
V (A)
V (A)
V (A)
Return
Return
Return
Return
Return
No Connection
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J3) connector type
Molex 26-60-4060 type.
DC (J3) mating connector type
Molex 09-50-3061 with Molex 2478 phosphor
bronze crimp terminals or equivalent.
DUAL
V (B)
V (A)
V (A)
Return
Return
N/C
TRIPLE
V (B)
V (A)
V (A)
Return
Return
V (C)
DERATING CURVE
Output Power (Watts)
75W
20 CFM FORCED AIR COOLING
65W
NATURAL
CONVECTION
COOLING
Note: The input and output connectors are the same as those used on NFS40,
NFN40, NAL40, NAN40 and NLP40.
0˚C
38W
32W
10˚C 20˚C 30˚C 40˚C 50˚C 60˚C
70˚C
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP65.PDF Rev: 15 Jan 2002