NLS110-9602 Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 1 • • • • • 7.0 x 4.25 x 1U package Overvoltage and short circuit protection 110W with 20CFM 90VAC to 264VAC universal input range EN55022 conducted emissions level B, radiated emissions level A • UL, VDE and CSA safety approvals • CE mark The NLS110-9602 is a 110W universal input AC/DC power supply on a 7 x 4.25 inch card. The NLS110-9602 has proven itself to be highly reliable and versatile product for a wide range of communication and industrial applications, with a very high peak current capability on each output for drive and motor applications. The NLS110-9602 provides 80W of output power with free air convection cooling which can be boosted to 110W with 20CFM of air. Standard features include overvoltage and short circuit protection. The NLS110-9602 with full international safety approval and the CE mark, meets conducted emissions EN55022 level B. The NLS110-9602 is designed for use in low power data networking, computer, telecom and industrial applications such as servers, thermal printers, storage devices, vending machines and POS equipment. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Total regulation Line and load Rise Time At turn-on (See table) (See table) Temperature coefficient ±0.02%/°C Overvoltage protection +5.1V 125%, ±10% Short circuit protection Cyclic operation Yes with auto recovery 35ms @ 80W 25ms @ 110W Efficiency 120VAC @ 110W 70% min. Isolation voltage Input/output Input/chassis 3000VAC 1500VAC Approvals and standards Universal input 90 to 264VDC Input frequency range 47Hz to 440Hz Input surge current (cold start) 120VAC 230VAC Safety ground leakage current 120VAC, 60Hz 230VAC, 50Hz Input current 120VAC 120VAC 230VAC 230VAC Input fuse UL/IEC127 EMC CHARACTERISTICS 0.95A 1.35A 0.53A 0.75A (11) EN55022, FCC part 15 EN55022, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-2 EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 Level B Level A Compliant Level Level Level Level Level Level 3 3 3 3 3 3 (6,8) Operating ambient, 0°C to +50°C (see derating curve) Non-operating –40°C to +85°C +50°C to +70°C, Derate to amb. convection cooled 50% load 0°C to +50°C, 80W amb. convection cooled 0°C to +50°C ambient, 110W 150LFM forced air Peak (0°C to +50°C, 60s) (See Note 4) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 7) 5Hz to 500Hz Shock per MIL-STD-810E rms rms rms rms F3.15A H, 250VAC 220,000 hours min. Thermal performance 0.45mA 0.75mA 80W 110W 80W 110W 383g (13.5 oz.) MIL-HDBK-217F ENVIRONMENTAL SPECIFICATIONS 18A max. 35A max. @ @ @ @ EN60950, VDE0805, IEC950 UL1950, CSA C22.2 No. 950 Weight MTBF (@ 25˚C) INPUT SPECIFICATIONS Conducted emissions Radiated emissions Harmonic current emission correction ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity 120VAC @ 60Hz 1.0s, max. Transient response Input voltage range Hold-up time 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV File Name: NLS110.PDF Rev: 12 June 2001 NLS110-9602 Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT VOLTAGE OUTPUT CURRENTS MAX (1) PEAK (2) FAN RIPPLE (3) TOTAL REGULATION (4) +5.1V 8.0A 20.0A 10.0A 50mV ±2.0% +24.0V 3.5A 4.5A 4.5A 240mV ±5.0% +12.0V 4.5A 9.0A 5.0A 120mV ±3.0% –12.0V 0.5A 1.5A 1.0A 120mV ±3.0% Notes NLS110-9602 (12) TRANSIENT RESPONSE 1 2 Convection cooled, 80W maximum. Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110W. 3 Forced air, 20CFM at 1 atmosphere, 110W maximum. 4 Amplitude is peak-to-peak. Output ripple is measured across a 20MHz bandwidth using a 12 inch twisted pair terminated with a 10µF capacitor. 5 Total regulation is defined as the static output regulation at 25°C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. 6 Derating curve is application specific for ambient temperatures >50°C. 7 Three orthogonal axes, random vibration, 10 minute test for each axis. 8 For optimum reliability no part of the heatsink should exceed 100oC and no semiconductor case temperature should exceed 115oC. 9 Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 10 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 11 The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering is required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, (AC input cords looped twice through an EMI suppression toroid) was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance. 12 Requires a minimum mounting stand-off of 6.35mm (0.25 inches) in the end use product. OUTPUT PIN CONNECTIONS J2 FUNCTION Pin 1 +5.1V Pin 2 +5.1V Pin 3 Return Pin 4 Return Pin 5 Return Pin 6 Return Pin 7 +12V Pin 8 +12V Pin 9 +24V Pin 10 PFD Pin 11 -12V Return Pin 12 -12V MODEL NUMBERS (5) INPUT PIN CONNECTIONS J1 Pin 1 AC Neutral Pin 2 No Connection Pin 3 AC Line J4 Pin 1 Safety Earth NLS110-9602 +5.1V (7.5A to 10A) +24V (1.5A to 3A) +12V (2.5A to 5A) -12V (0.5A to 1A) 150mV peak, 1ms recovery 300mV peak, 1ms recovery 100mV peak, 0.5ms recovery 100mV peak, 0.5ms recovery DERATING CURVE Output Power (Watts) 110W 150 LFM FORCED AIR COOLING 80W NATURAL CONVECTION COOLING 55W 40W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC INPUT 5V OUTPUT 4.75V 4.75V HIGH 3.5V MIN LOW PFD SIGNAL 0-0.4 MAX Please consult our website for the following items: ✔ Application Note T3 T1 T2 Power fail detect signal 50ms≤T1≤200ms T2 will vary with line and load T3≥3ms Pout: 110W PFD output is an open collector which will sink ≤40mA in the low state. www.artesyn.com File Name: NLS110.PDF Rev: 12 June 2001 NLS110-9602 Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm Mechanical Notes A All dimensions are in inches (mm). 2 7.00 (177.80) 6.500 (165.100) 4 3 J4 1 T1 (REF) 12 4.25 (107.95) T2 (REF) 3.750 (95.250) Recommended direction for forced air relative to power supply orientation shown below. 1 2 3 4 J2 F1 Optimum. Very good. Not recommended. Not recommended. 1 3 J1 1 0.25 (6.35) 0.25 (6.35) J5 2 1 TOLERANCE: .XXX: ±0.005 (0.127) .XX: ±0.02 (0.51) ALL DIMENSIONS IN INCHES (mm) Input and output connectors Mating connectors AC (J1) connector type Molex 26-60-4030 or equivalent. AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) connector type 12 position Molex Spox type 26-48-1125 or equivalent. DC (J2) mating connector type Molex Spox type 26-03-3121 and contact 08-52-0113. Earth (J4) connector type Male 0.250 quick disconnect. Earth (J4) mating connector type Molex 90028. International Safety Standard Approvals VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1049 Licence No. 2874, 1653 and 1049 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: ✔ Application Note www.artesyn.com File Name: NLS110.PDF Rev: 12 June 2001