ARTESYN NLP65-3322

NLP65-3322
Triple output
LOW POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
60W AC/DC Universal Input Switch Mode Power Supplies
1
5.0 x 3.0 inch card and 1.26 inch package (1U applications)
Smallest industry standard package
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
60W with free air convection cooling
EN55022, EN55011 conducted emissions level B
EN61000-4-2,-3,-4, -5, -6 immunity compliant
The NLP65-3322 is a 60W universal input AC/DC power supply on a 5 x 3 inch card
with a maximum component height of 1.26 inches for use in 1U applications. This
model has the option of input harmonic current correction in the same package size
making the series ideal for product designs that will need to comply with EN61000-32 legislation. The NLP65-3322 provides 60W of output power with free air convection
cooling which can be boosted to 70W with 20CFM of air. The NLP65, with full
international safety approval, meets conducted emissions EN55022 level B and has
immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP65 series is designed for
use in low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, internet servers, cable modems and PABX’s. This list is not
exclusive as the generic feature set of the NLP65 series with industry standard output
configurations provides a solution for most low power applications including many
industrial applications.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS (continued)
Total regulation
(Line and load)
Main output
Auxiliary outputs
Rise time
At turn-on
Transient response
Main output
25% step
at 0.1A/µs
±2.0%
±5.0%
1.0s, max.
5.0% or 250mV
max. dev., 1ms max.
recovery to 1%
Temperature coefficient
Overvoltage protection
±0.02%/°C
Radiated immunity
Conducted immunity
Surge
Fast transients
Radiated immunity
Conducted immunity
EN61000-4-3,
EN61000-4-6,
EN61000-4-5,
EN61000-4-4,
EN61000-4-3,
EN61000-4-6,
Hold-up time
230VAC, 50Hz
125%, ±10%
Efficiency
Short circuit protection
Cyclic operation
Yes, indefinite
Isolation voltage
Minimum output current
Single and multiple
Input/output
Input/chassis
Switching frequency
Fixed
Input voltage range
(See Note 1)
Universal input
(See Note 6)
Input frequency range
47Hz to 63Hz
Input surge current
(cold start)
120VAC
230VAC
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
Inrush current
230VAC
Input current
120VAC,
230VAC,
120VAC,
230VAC,
Input fuse
17A max.
32A max.
0.7mA
1.4mA
32A max.
with PFC
with PFC
without PFC
without PFC
UL/IEC127
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
85 to 264VAC
120 to 370VDC
1.05A
0.51A
1.40A
0.80A
rms
rms
rms
rms
250VAC S 3.15A
level
level
level
level
level
level
3
3
2
3
3
3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
criteria
criteria
criteria
criteria
criteria
criteria
2
2
1
1
2
2
GENERAL SPECIFICATIONS
Main outputs
INPUT SPECIFICATIONS
(11,12)
75% typical
3000VAC
1500VAC
100kHz, ±5kHz
Approvals and
standards
(See Notes 9 and 12)
EN60950, UL1950,
cUL equivalent of
CSA C22.2 No. 950
Weight
MTBF
78ms @ 60W
283g (10 oz)
MIL-HDBK-217F
150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 1, 4 and 10)
Operating temperature
0°C to +50°C
Non-operating
-40°C to +85°C
50°C to 70°C ambient,
1.65W/°C
convection cooled
Peak (0°C to +50°C, 60s)
See table
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
5% to 95% RH
10,000m max.
30,000m max.
Vibration (See Note 5)
5Hz to 500Hz
2.4G rms peak
Shock
per MIL-STD-810E
(11,12)
EN55022, FCC part 15 (Note 11)
EN55022, FCC part 15 (Note 11)
EN61000-4-2, level 3
Perf.
EN61000-4-2, level 4
Perf.
EN61000-4-5, level 3
Perf.
EN61000-4-4, level 3
Perf.
Level B
Level A
criteria 1
criteria 1
criteria 3
criteria 1
516.4 Part IV
File Name: NLP65-3322.PDF Rev: 24 Feb 2000
NLP65-3322
Triple output
LOW POWER AC/DC POWER SUPPLIES
60W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
RIPPLE
VOLTAGE
MAX
(4)
PEAK
(2)
FAN
(3)
(10)
9.1A
8.0A
50mV
±100mV
6.25V ± 0.5V
+24V
1.5A
2.6A
2.0A
240mV
±1200mV
---
+12V
0.7A
1.0A
1.0A
120mV
±600mV
---
N
7
4
5
6
MODEL
NUMBER
7.0A
1
3
OVP
(6)
+5V
Notes
2
TOTAL
REGULATION
When the input voltage is less than 90VAC the operating temperature
range is 0°C to +40°C. The ripple and regulation specifications may not be
met.
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20MHz bandwidth using a 6 inch twisted
pair, terminated with a 10µF electrolytic capacitor and a 0.1µF ceramic
capacitor.
Maximum continuous output power must not exceed 60W.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
To maintain stated regulation then:
I ≥ 0.2A I max.
PIN
Pin 1
Pin 2
Pin 3
Pin 1
INPUT
CONNECTIONS
J1
AC Line
No Pin
AC Neutral
J2
Safety Ground
OUTPUT PIN CONNECTIONS
J3
TRIPLE
Pin 1
+24V
Pin 2
+5V
Pin 3
+5V
Pin 4
Return
Pin 5
Return
Pin 6
+12V
8
9
10
11
12
13
NLP65-3322
For optimum reliability, no part of the heatsink should exceed 120oC, and
no semiconductor case temperature should exceed 130oC.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Maximum continuous output power for this model must not exceed 70
Watts with 20CFM forced air cooling.
For system EMI compliance the unit must be mounted within a metal
chassis.
All models require a minimum mounting stand-off of 0.25 inches (6.35mm)
in the end use product.
Contact factory for further details with respect to harmonic current
correction.
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J3) connector type
Molex 26-60-4060 type.
DC (J3) mating connector type
Molex 09-50-3061 with Triurcon 6838
or equivalent crimp terminals.
DERATING CURVE
Output Power (Watts)
70W
20 CFM FORCED AIR COOLING
60W
NATURAL
CONVECTION
COOLING
0°C 10°C
20°C
30°C
40°C
33W
27W
50°C
60°C
70°C
www.artesyn.com
File Name: NLP65-3322.PDF Rev: 24 Feb 2000
NLP65-3322
Triple output
LOW POWER AC/DC POWER SUPPLIES
60W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
5.00
(127.00)
4.550
(115.57)
3
N
0.225
(5.715)
1
J1
L
1
J3
6
3.00
(76.20)
2.550
(64.770)
T1
J2
C19
Mounting
ALL DIMENSIONS IN INCHES (mm)
Hole Diameter
0.156 (4.00)
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE:
.xxx
.xx
±
±
0.005"
0.02"
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-1096
Licence No. 93678
cUL, UL1950 File No. E136005
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP65-3322.PDF Rev: 24 Feb 2000