EXCELICS RFMA2124-0.5W

RFMA2124-0.5W
21.2 – 23.6 GHz Power Amplifier MMIC
UPDATED 10/25/2006
FEATURES
•
•
•
•
21.2 – 23.6 GHz Operating Frequency Range
26.5 dBm Output Power at 1dB Compression
26.0 dB Typical Small Signal Gain
-41dBc Typical OIM3 @ each tone Pout 15.5 dBm
Excelics
RFMA2124
-0.5W
APPLICATIONS
•
•
Point-to-point and point-to-multipoint radio
Military Radar Systems
Caution! ESD sensitive device.
ELECTRICAL CHARACTERISTICS (Ta = 25 °C, 50 ohm, Vdd=7V, Vgg=-5V)
SYMBOL
F
P1dB
GSS
OIMD3
Input RL
Output RL
PARAMETER/TEST CONDITIONS
MIN
Operating Frequency Range
TYP
21.2
MAX
UNITS
23.6
GHz
Output Power at 1dB Gain Compression
25
26.5
dBm
Small Signal Gain
Output 3rd Order Intermodulation Distortion
@∆f=10MHz, Each Tone Pout 15.5 dBm
20
23
dB
-41
-38
dBc
Input Return Loss
-10
dB
Output Return Loss
-8
dB
760
mA
Idd
Drain Current
Vdd
Drain Supply Voltage
7
Rth
Thermal Resistance (Au-Sn Eutectic Attach)
9
Tb
Operating Base Plate Temperature
-30
8
V
o
C/W
+80
ºC
MAXIMUM RATINGS @25°C
SYMBOL
CHARACTERISTIC
ABSOLUTE
CONTINUOUS
1,2
VDD
Drain Supply Voltage
12V
8V
VGG
Gate Supply Voltage
-8V
-3V
IDD
Drain Current
Idss
1.1A
IGG
Gate Current
60mA
10 mA
PIN
Input Power
20dBm
@ 3dB compression
TCH
Channel Temperature
175°C
150°C
TSTG
Storage Temperature
-65/175°C
-65/150°C
8.8W
7.4W
PT
Total Power Dissipation
1. Operating the device beyond any of the above rating may result in permanent damage.
2. Bias conditions must also satisfy the following equation Vdd*Idd < (TCH –Tb)/RTH; where Tb = operating base plate temperature
Specifications are subject to change without notice.
Excelics Semiconductor, Inc. 310 De Guigne Drive, Sunnyvale, CA 94085
page 1 of 2
Phone: 408-737-1711 Fax: 408-737-1868 Web: www.excelics.com
Revised November 2006
RFMA2124-0.5W
21.2 – 23.6 GHz Power Amplifier MMIC
UPDATED 10/25/2006
01 Package Outline
0.330
4X.050 CHAMFER
0.165
2X DIA .090 THRU
0.200
PIN1 Indicator
NC
Vgg
4X 0.100
RF IN
4X 0.050
NC
Excelics
RFMA2124
-0.5W-01
Vdd
10X 0.013
RF OUT
Vgg
Vdd
NC
NC
10X 0.100±0.010
0.060
10X 0.004
0.040
0.025
All dimensions in inches
ORDERING INFORMATION
Part Number
RFMA2124-0.5W-01
Refer 01 Package Outline
DISCLAIMER
EXCELICS SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY
PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. EXCELICS DOES NOT ASSUME ANY
LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN.
LIFE SUPPORT POLICY
EXCELICS SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE
SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF EXCELICS SEMICONDUCTOR,
INC.
AS HERE IN:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b)
support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in
the labeling, can be reasonably expected to result in significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Specifications are subject to change without notice.
Excelics Semiconductor, Inc. 310 De Guigne Drive, Sunnyvale, CA 94085
page 2 of 2
Phone: 408-737-1711 Fax: 408-737-1868 Web: www.excelics.com
Revised November 2006