Velociti® Series ASD-IL2F Description Analog, Addressable Ionization Smoke Sensor The Gamewell-FCI Velociti® Series, analog addressable plug-in smoke sensors with integral communication provide features that surpass conventional sensors. Sensor sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each sensor’s address to be set, providing exact locations for selective maintenance when the chamber contamination reaches an unacceptable level. The ASD-IL2F ionization sensor incorporates a unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain GamewellFCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. ASD-IL2F Features • Sleek, low-profile design • Visual rotary switch addressing • Built-in functional test switch activated by an external magnet • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm* • Optional relay, isolator, or sounder bases • Low standby current • Addressable-analog communication • Stable communication technique with noise immunity Ordering Information • Optional remote, single-gang LED accessory RA400Z • Suitable for installation in ducts Model ASD-IL2F Description Analog, Addressable Ionization Smoke Sensor Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. An ISO 9000-2000 Company SIGNALING ® ® Velociti and E3 Series are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. FM S1913 MEA Approved 3023594 219-02-E Vol.VI 07271-0694:199 APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9020-0619 Rev. B3 page 1 of 2 ©2008 by Honeywell International Inc. All rights reserved. Installation Specifications ASD-IL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove the sensors without using a ladder. Size Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • 4.0" (10.2 cm) square box. • 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single-gang box (except relay or isolator base). • With B501BH or B501BHT base, use a 4.0" (10.2 cm) square box. • With B224RB or B224BI base, use a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. Shipping Weight Operating Temperature 2.1” (5.1 cm) high x 4.1” (10.4 cm) diameter installed in B501 base, 6.1” (15.5 cm) diameter installed in ADB-FLF base 5.4 oz. (154 g) 32° F to 120° F (0 to 49° C) ® UL -Listed 0-1200 ft./min. (365.8 m/min.) Velocity Range Relative Humidity 10-93% (non-condensing) Electrical Specifications Voltage Range Standby Current 15 – 32 volts DC peak. .0003A @ 24 VDC (One communication every 5 seconds with LED enabled) NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “Ttaps” or branches are permitted for Style 4 (Class “B”) wiring. Maximum Alarm Current Sensor Spacing Bases and Options Gamewell-FCI recommends spacing sensors in compliance with NFPA 72. In low airflow applications with smooth ceilings, space detectors 30 feet (9.144 m). For specific information regarding sensor spacing, placement, and special applications, refer to NFPA 72. ADB-FLF B501 B501BH or B501BHT B224RB Relay Base B224RB Relay Base Dimensions B524BI Isolator Base Dimensions RA-400Z BCK-200 GAMEWELL-FCI .0065A @ 24 VDC (LED lit) 6.1” (15.5 cm) diameter 4.1” (10.4 cm) diameter Sounder base assembly (B501BHT produces a Temporal Pattern) Includes B501 base Screw terminals: Up to 14 AWG (2.0 mm2) Relay type: Form-C Rating: 2.0A @ 30 VDC resistive 0.3 A @ 110 VDC inductive 1.0 A @ 30 VDC inductive 6.2” x 1.2” (15.7 x 3.0 cm) 6.2” x 1.2” (15.7 x 3.0 cm) Maximum: 25 devices between isolator bases. Remote alarm indicator, LED Black detector covers (box of 10) 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0619 Rev. B3 page 2 of 2 www.gamewell-fci.com