TFS 135.doc version 1.5 VI TELEFILTER Filter Specification 05.07..2002 TFS 135 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc*: 23 °C 0 dBm input: output: 1,5 kΩ// -6,0 pF 1,5 kΩ// -5,0 pF 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 135 is the insertion loss. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value tolerance / limit max Insertion loss (reference level) ae 14,5 dB Centre frequency fc - (at ambient temperature TA ) Relative attenuation arel fc fc ± fc ± ...... fc ± 1,25 MHz 4 MHz ...... fc ± 6 MHz 6 MHz ...... fc ± 15 MHz fc ± 35 200 dB kHz max 3 dB dB min 30 dB 38 dB min 35 dB MHz 40 dB min 38 dB 1,0 MHz 35 ns max 80 ns fc ± 15 MHz ...... fc ± 24 Group delay ripple: 135,420 MHz ± 16,0 Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T: -19 ppm/K - ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) Operating temperature range - 10 °C ... + 85 °C Storage temperature range - 25 °C.... + 85 °C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. generated: checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135.doc version 1.5 VI TELEFILTER Filter Specification 05.07..2002 TFS 135 2/5 3. Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) +0.15 5.0 SQ -0.1 7 5 S 135 P33 1 1 2 3 4 5 6 7 8 input input ground ground output output ground ground Date code: M N P ...... year + week 2000 2001 2002 3 Date code 50 Ω test circuit LB-IN C1 1 SAW L1 C2 C3 5 L2 6 2 LB-OUT C4 3,4,7,8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135.doc version 1.5 VI TELEFILTER Filter Specification 05.07..2002 TFS 135 3/5 4. Stability characteristics 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; 5. Packing Tape & Reel: DIN IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W : 12 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 D1 : 1,5 + 0,5 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE D o Po P 2 E A E : 1,75 ± 0,1 F : 7,5 ± 0,1 o F D 13,4 G (min) : 0,75 P2 : 2 ± 0,05 P1 : 8 ± 0,1 ± 0,1 B 1 W o G D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 5,3 ± 0,1 P1 COVER TAPE W2 Reel (all d im ensions in m m ): A : 330 W2 (m ax) : N (m in) : C : 18 ,4 50 13 W1 : 12 ,4 + 0 ,2 + 0 ,2 / -0 ,5 A C N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135.doc version 1.5 VI TELEFILTER Filter Specification 05.07..2002 TFS 135 4/5 6. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 ° main-heating periods Cover 200 °C 60 sec. - 90 sec. peak temperature 255 °C ± 5 °C 20 sec. - 25 sec. Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135.doc version 1.5 VI TELEFILTER Filter Specification 05.07..2002 TFS 135 5/5 7. History Version Reason of Changes Name Date 1.0 generate specification Pfeiffer 18.09.2001 1.1 typical values added changing relativ attenuation in stopband terminating impedance added (primary value) Pfeiffer 24.10.2001 1.2 terminating impedance changed (preliminary value) Pfeiffer 16.11.2001 1.3 changed matching configuration Î balanced driven Pfeiffer 27.11.2001 1.4 terminating impedance changed changing relativ attenuation in stopband Pfeiffer 14.01.2002 1.5. changing max insertion loss changing range of centre frequency Pfeiffer 05.07.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information