MEANWELL RSP-1000-48

RSP-1000
1000W Single Output Power Supply
series
Features :
Universal AC input / Full range
AC input active surge current limiting
Built-in 5V/0.5A auxiliary power
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Output voltage can be trimmed between 40 ~ 110% of the rated output voltage
Forced air cooling by built-in DC fan
3
High power density 10.7w/inch
1U low profile 41mm
Active current sharing up to 4000W(3+1) (Note.8)
DC OK Signal
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
..
SPECIFICATION
MODEL
RSP-1000-12
RSP-1000-15
RSP-1000-24
RSP-1000-27
RSP-1000-48
DC VOLTAGE
12V
15V
24V
27V
48V
RATED CURRENT
60A
50A
40A
37A
21A
CURRENT RANGE
0 ~ 60A
0 ~ 50A
0 ~ 40A
0 ~ 37A
0 ~ 21A
RATED POWER
720W
750W
960W
999W
1008W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
13.5 ~ 16.5V
20 ~ 26.4V
RIPPLE & NOISE (max.) Note.2 150mVp-p
OUTPUT
24 ~ 30V
43 ~ 55V
VOLTAGE TOLERANCE Note.3
10 ~ 13.5V
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
VOLTAGE ADJ. RANGE
300ms, 50ms at full load
SETUP, RISE TIME
16ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.95/230VAC
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
83%
12A/115VAC
25A/115VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
16ms/115VAC at full load
127 ~ 370VDC
0.98/115VAC at full load
85%
88%
88%
90%
6A/230VAC
40A/230VAC
105 ~ 125% rated output power
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER(AUX)
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.8V
17 ~ 20.5V
27.6 ~ 32.4V
31 ~ 36.5V
56.6 ~ 66.2V
Protection type : Shut down o/p voltage, re-power on to recover
85
5 (TSW2 ) detect on heatsink of O/P diode; 75
5 (TSW1 ) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V @ 0.5A (+5%, -8%)
Power off : open between on/off(pin6) & -S(pin2) on CN50
REMOTE ON/OFF CONTROL Note.6 Power on : short between on/off(pin6) & -S(pin2) on CN50
FUNCTION DC OK SIGNAL
The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V
OUTPUT VOLTAGE TRIM Note.6 Adjustment of output voltage is possible between 40 ~ 110% of rated output
CURRENT SHARING(CS)Note.7 Please refer to function manual
-20 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
0.02%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
(Note 4)
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
35K hrs min. MIL-HDBK-217F (25
295*127*41mm (L*W*H)
1.95Kg; 6pcs/12.7Kg/0.99CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains two shorting wires: one is from on/off(pin6) to -s(pin2)
and the other is from Vco(pin8) to Vca(pin10). Please refter to function manual for details.
7. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition.
8. Please consult MEAN WELL for applications of more units connecting in parallel.
RSP-1000
1000W Single Output Power Supply
Mechanical Specification
Case No. 952B
277.7
Unit:mm
25.4
20.5
7.8
6
series
3-M4 L=6
295
21
34.5
18.5
41
59
+V
-V
21
CN50
Air flow
direction
90
127
SVR51
12 11
10
7
3
2
1
TB1
3-M4 L=4
7.8
20.5
25.4
3-M4 L=6
6
277.7
AC Input Terminal
Pin No. Assignment
Pin No.
1
2
3
Control Pi n No. Assignment (CN50) : HRS DF11-12DP-2DS or equivalent
Pin No.
1
2
3
4
Assignment
AC/N
AC/L
FG
Pin No.
5
6
7
8
Assignment
+S
-S
G-AUX
5V-AUX
Pin No.
9
10
11,12
Assignment
DC-OK
ON/OFF
CS
Vco
Assignment
Vci
Vca
GND
Mating Housing
Terminal
HRS DF11-12DS
or equivalent
HRS DF11-**SC
or equivalent
Block Diagram
+S
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
PFC
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CONTROL
+V
-V
-S
CURRENT
SHARE
CURRENT
SHARE
O.L.P.
DETECTION
CIRCUIT
PWM
CONTROL
PFC fosc : 110KHz
PWM fosc : 90KHz
DC OK
V_TRIM
O.V.P.
RECTIFIERS
CONTROL
ON/OFF
AUX
POWER
Derating Curve
FAN
ON/OFF
AUX POWER(5V/0.5A)
RECTIFIERS
&
FILTER
AUX GND
Static Characteristics
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
60
50
40
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
90
95
100
115
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RSP-1000-SPEC 2008-01-22
RSP-1000
1000W Single Output Power Supply
series
Function Description of CN50
Pin No. Function Description
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
1
+S
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2
-S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
4
G-AUX Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Auxiliary voltage output, 4.6~5.25V, referenced to pin 3(G-AUX). The maximum load current is 0.5A. This output has the built-in oring
5V-AUX diodes and is not controlled by the "remote ON/OFF control".
5
Open collector signal, referenced to pin11,12(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum
DC_OK external voltage is 5.6V.
3
6
7
ON/OFF Turns the output on and off by electrical or dry contact between pin 6 ( ON/OFF) and pin 2 (-S). Short: Power ON, Open: Power OFF.
Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance
CS
between units.
8
Vco
9
Vci
10
Vca
Connect to external resistor (1/8W) for output voltage triming. Output voltage can be trimmed between 40 ~ 110% of the rated output
voltage. Please refer to function manual for details.
11,12
GND
These pins connect to the negative terminal (-V). Return for DC_OK Signal output.
Short connecting between Vco (pin8) and Vca (pin10) if output voltage trim function is not used.
Connect to external DC voltage source for output voltage triming, referenced to pin 2 (-S). Output voltage can be trimmed between
40 ~ 110% of the rated output voltage.
Function Manual
1."Remote ON/OFF" and "Output voltage trim" functions are not used.
The power supply unit will have no output if the shorting connector (accessory comes along with the PSU) is not assembled. It contains
two shorting wires : one is from ON/OFF (pin6) to -S (pin2) and the other is from Vco (pin8) to Vca (pin10).
1 11
2 12
-V SVR51 CN50
+V
TB1
1
LOAD
+
+S
11
CN50
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
AUXG DC_OK
-S
Fig 1.1
12
2
(Shorting connector)
File Name:RSP-1000-SPEC 2008-01-22
RSP-1000
1000W Single Output Power Supply
series
2.Remote ON/OFF
The PSU can be turned ON/OFF by using the "Remote
ON/OFF" function
Between ON/OFF(pin6) and -S(pin2)
Output Status
SW ON (Short)
ON
SW OFF (Open)
OFF
1 11
2 12
-V SVR51 CN50
+V
TB1
CN50
1
+S
LOAD
+
-
-S
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
12
2
Fig 2.1
SW
3.DC_OK signal
"DC_OK" is an open collector signal.
It indicates the output status of the PSU. It can operate
in two ways : One is sinking current from external TTL
signal ; the other is sending out a TTL voltage signal.
3-1 Sink current :
The maximum sink current is 10mA and the maximum
external voltage is 5.6V.
1 11
2 12
-V SVR51 CN50
+V
TB1
3-2 TTL voltage signal :
Between DC- OK(pin5) and GND(pin11&12)
Output Status
0 ~ 1V
ON
3.3 ~ 5.6V
OFF
1
Fig 3.1
+S
-S
CN50
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
12
2
4.Remote Sense
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
1 11
2 12
-V SVR51 CN50
+V
TB1
1
+S
(pin1)
LOAD
+
-S
- (pin2)
+S
Sense lines should
be twisted in pairs
-S
2
CN50
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
12
Fig 4.1
File Name:RSP-1000-SPEC 2008-01-22
RSP-1000
1000W Single Output Power Supply
series
5.Output Voltage TRIM
Output voltage of RSP-1000 can be trimmed between
40% ~ 110% of its rated value by the following methods :
(1)Using external voltage source between
"Vci"(pin9) and "-S"(pin2) that is shown in Fig5.1
OVP 120%(Typ.)
Vout
OUTPUT VOLTAGE (%)
120
100
80
+V
Non-Linear
1 11
2 12
-V SVR51 CN50
TB1
60
40
20
1
2
3
4
5
6
1
Vci(Referenced to -S)
EXTERNAL VOLTAGE (VDC)
CN50
11
+S
AUXG DC_OK
CS
Vci
GND
-S
AUX ON/OFF
Vco
Vca
GND
2
12
External Voltage
Fig 5.1
(2)Connecting a resistor externally that in shown in Fig 5.2 & Fig 5.3
(A) O/P voltage goes down
OUTPUT VOLTAGE (%)
Vout
100
90
CN50
1
80
Non-Linear
11
+S
AUXG DC_OK
CS
Vci
GND
-S
AUX ON/OFF
Vco
Vca
GND
70
60
2
50
12
40
390 560 820 1K2 2K2 4K7 open
R1
R1, 1/8W(Typ.)
EXTERNAL RESISTOR ( )
Fig 5.2
(B)O/P voltage goes up
Vout
OUTPUT VOLTAGE (%)
OVP 120%(Typ.)
110
CN50
1
Non-Linear
105
11
+S
AUXG DC_OK
CS
Vci
GND
-S
AUX ON/OFF
Vco
Vca
GND
2
12
100
R2
open
18K
7K5
R2, 1/8W(Typ.)
Fig 5.3
EXTERNAL RESISTOR ( )
File Name:RSP-1000-SPEC 2008-01-22
RSP-1000
1000W Single Output Power Supply
series
6.Current Sharing with Remote Sensing
RSP-1000 has the built-in active current sharing function and can be connected in parallel to provide higher output power :
(1)Parallel operation is available by connecting the units shown as below.
(+S,-S and CS are connected mutually in parallel).
(2)Difference of output voltages among parallel units should be less than 2%.
(3)The total output current must not exceed the value determined by the following equation.
(output current at parallel operation)=(Rated current per unit) (Number of unit) 0.9
(4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel.
(5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
PSU
+V
PSU
1 11
2 12
-V SVR51 CN50
TB1
+V
PSU
1 11
2 12
-V SVR51 CN50
TB1
+V
PSU
1 11
2 12
-V SVR51 CN50
TB1
1 11
2 12
-V SVR51 CN50
+V
TB1
+S(pin1)
-S(pin2)
CS(pin7)
+V
-V
Sense lines should
be twisted in pairs
LOAD
Fig 6.1
CN50
1
+S
-S
2
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
12
CN50
1
+S
-S
2
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
12
CN50
1
+S
-S
2
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
12
CN50
1
+S
-S
AUXG DC_OK
11
CS
Vci
GND
AUX ON/OFF Vco
Vca
GND
2
12
Note : In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition.
The other PSUs (slaves) may go into standby mode and their output LEDs will not turn on.
File Name:RSP-1000-SPEC 2008-01-22