MPG-120S Series Single Output, 120W Green, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 120W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter • 150W With Only 7 CFM Input Voltage Range • Universal 85-264 AC Input • EN 60950 Approved (UL) Input Frequency Input Filter Input Current • Meets ErP Directive Inrush Current • Compact 3 x 5 Inch Size • PFC Meets EN 61000-3 • Optional +5V SB Output • >400 kHour MTBF Conditions Min. Typ. Max. 85 264 110 373 47 63 Meets EN 55022 Class B; FCC Class B See Model Selection Guide Cold Start, 115 VAC 30.0 Cold Start, 230 VAC 60.0 Meets EN 61000-3-2/3 Class A 0.25 0.5 Universal Power Factor Correction Leakage Current No Load Power Consumption Units VAC VDC Hz A Pk mA W Output Parameter Output Voltage/Current Output Voltage Tolerance Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection Conditions Min. Typ. See Model Selection Guide See Note 1 ±1.0 See Note 2 ±1.0 See Note 3 ±1.0 See Note 4 ±1.0 115 VAC 20 230 VAC 40 ±0.05 140 Continuous (Autorecovery) Max. Conditions Input to Output 500 VDC Max. Units % % % % mSec %/°C % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance EMI Characteristics Parameter Radiated Emissions, See Note 5 Conducted Emissions , See Note 5 ESD RS EFT Surge CS PFMF Voltage Dips, See Note 6 MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Switching Frequency Standard Min. 3,000 Typ. 100 2,200 Min. Units VAC M⍀ pF Typ. Max. Units Class B Class B Criteria A; ±8 kV Air/±6 kV Contact Criteria A; 10V/m Criteria A; ±2 kV Line & PE Criteria A; L-N: ±1kV, L/N-PE: ±2kV Criteria A; 10 Vrms Criteria A; 10A/ms Criteria A; Volt. Dips >95%, 0.5 Cycle Criteria A; Volt. Dips 30%, 25 Cycles EN 61000-4-11 Criteria A/B; Volt. Dips 60%, 5 Cycles Criteria C; Volt. Inter, >95%, 250 Cycles Fixed 65 kHz EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Size Weight Conditions Min. Typ. Max. -20 +25 +70 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % 5.00 x 3.00 x 1.35 Inches (127.00 x 76.20 x 34.2 mm) 9.87 Oz (0.280 kg) Reliability Specifications Parameter MTBF Safety Standards Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 400 UL 60950, EN 60950 www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number MPG-120S-12 Input Current (A) 115 VAC 230 VAC 2.50 1.25 MPG-120S-12SB 2.50 1.25 MPG-120S-24 2.50 1.25 MPG-120S-24SB 2.50 1.25 MPG-120S-48 2.50 1.25 MPG-120S-48SB 2.50 1.25 No. 1 2 1 2 1 2 Voltage (VDC) 12.0 12.0 5.0 24.0 24.0 5.0 48.0 48.0 5.0 Output Current (A) Max. Rated Min. 10.00 10.00 0.10 5.00 5.00 0.10 2.50 2.50 0.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 (W/7 CFM) 12.50 12.50 0.10 6.25 6.25 0.10 3.13 3.13 0.10 Notes: 1. Output voltage tolerance is measured at 110 VAC input and 60% load. 2. Line regulation is measured at a 115 VAC input with the rated load. The line is varied ±10%. 3. Load regulation is specified for a load change of 60% ±40% (of full load). 4. Output ripple is measured at 20 MHz bandwidth and rated load using 0.1 µF and 10 µF capacitors connected in parallel as close to the power supply terminals as possible. 5. To meet the EMI limits, the mounting holes must be connected together (by using metal standoffs). 6. The unit meets EN 61000-4-11 criteria A for voltage dips of 60% at 100 VAC input. At 240 VAC input, it meets criteria B. 7. These units will operate at no load without damage. However, they may not meet all specifications. 8. The optional remote on/off function is active low. Contact the factory for details. 9. Each unit includes an input fuse (250V/3.15A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Max Output Power (W) Efficiency Convection With 7CFM Cooled Air Flow 120 150 (%, Typ) 88 120 150 88 120 150 89 120 150 89 120 150 89 120 150 89 Derating Curve Mechanical Dimensions Connections Input Connector (CN1): • Molex 09-65-2038 or equivalent (one pin removed) • Mating Housing: Molex 09-50-1031 or equivalent Pin 1 2 3 Function AC-Neutral Removed AC-Line Safety Ground: The mounting holes marked “Use metal standoffs” should be connected to the system earth ground via metal spacers or a cable. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This connection should be locked to prevent possible loosening. Connecting the output side mounting hole improves EMI. Output Connector (CN2): • Molex 09-65-2048 or equivalent • Mating Housing: Molex 09-50-1041 or equivalent Pin 1 2 3 4 5 6 Function +VOUT +VOUT +VOUT -VOUT -VOUT -VOUT Connector (CN3): • Molex 5045-03A or equivalent • Mating Housing: Molex 5043-03 or equivalent Pin 1 2 3 Function Remote On/Off Grnd +5Vsb Connector CN3 is only installed on “SB” models MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) FAX: (781) 344-8481 • E-Mail: [email protected]