POWERSEM PSMD100E-06

Fast Recovery
Epitaxial Diode
(FRED) Module
PSMD 100E
IFAV
VRRM
= 136 A
= 200-600V
Preliminary Data Sheet
VRSM
V
200
400
600
VRRM
V
200
400
600
Type
PSMD 100E/02
PSMD 100E/04
PSMD 100E/06
Symbol
Test Conditions
IFAV
IFSM
TC = 70°C
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
136
2000
2200
A
A
A
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
1800
1980
A
A
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
20000
20080
A2 s
A2 s
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
16200
16250
A2 s
A2 s
-40 ... + 150
150
-40 ... + 125
°C
°C
°C
2500
3000
V∼
V∼
5
5
270
Nm
Nm
g
∫ i2 dt
TVJ
TVJM
Tstg
VISOL
Md
Weight
50/60 HZ, RMS
IISOL ≤ 1 mA
Maximum Ratings
t = 1 min
t=1s
Mounting torque
Terminal connection torque
typ.
(M6)
(M6)
Features
• Package with screw terminals
• Isolation voltage 3000 V∼
• Planar glasspassivated chips
• Short recovery time
• Low forward voltage drop
• Short recovery behaviour
• UL registered, E 148688
Applications
• Inductive heating and melting
• Free wheeling diode in converters
and motor control circuits
• Uninterruptible power supplies
(UPS)
• Ultrasonic cleaners and welders
Advantages
• High reliability circuit operation
• Low voltage peaks for reduced
protection circuits
• Low noise switching
• Low losses
Symbol
Test Conditions
Characteristic Value
IR
VR = VRRM
TVJ = 25°C
VR = VRRM
TVJ = TVJM
IF = 100 A
TVJ = 25°C
TVJ = 25°C; IF=1A; -diF/dt=400A/µs
VR= 30V
IF=100A; -diF/dt=200A/µs; VR=100V
L ≤ 0,05 mH; TVJ = 100°C
For power-loss calculations only
TVJ = TVJM
per diode; DC current
per diode; DC current
Creeping distance on surface
Creeping distance in air
Max. allowable acceleration
≤
≤
≤
VF
trr
IRM
VTO
rT
RthJH
RthJC
dS
dA
a
POWERSEM GmbH, Walpersdorfer Str. 53
91126 D- Schwabach
Phone: 09122 - 9764-0 Fax.: 09122 - 9764-20
250
2.5
1.25
typ. 60
µA
mA
V
ns
typ. 45
A
0.45
1.25
0.84
0.65
10
9.4
50
V
mΩ
K/W
K/W
mm
mm
m/s2
Package, style and outline
Dimensions in mm (1mm = 0.0394“)
 2003 POWERSEM reserves the right to change limits, test conditions and dimensions