TRUMPower PFC 130 WATT POWER SUPPLIES D E SCR IPTION TFC130 SERIES The TFC130 series incorporates creative high efficiency circuitry, high power density (6.94 3 Watts/in ) and active Power Factor Correction (PFC) to meet the requirements of data networking, computing and telecommunication systems. Some models with one or two outputs adjustable between 5V and 24V intend to suit more applications. (MULTIPLE OUTPUT) (LVD) RoHS F EATU R E S ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ EN61000-3-2 class A and D compliant Pow er factor 0.98 typical Ve r y c o m pa c t s i z e , 3 ″ × 5 ″ × 1 . 2 ″ O v e r v o l ta g e p r o t e c t i o n Short circuit protection Remote sense on 3.3V output Pow er Good/Pow er Fail Detect Signal U p t o f i v e D C o u t p u ts A l l o u t p u ts w e l l r e g u l a t e d C o m p l i a n t w i t h R o H S r e q u i r e m e n ts Saf et y Sta n da rd A ppr o va ls: UL 60950 3rd CSA C22.2 No. 60950 3rd TÜV EN60950-1 IN PUT S PE C IF ICAT ION S Input voltage: Input frequency: Input current: Earth leakage current: (Touch Current) 90 to 264VAC 47 to 63Hz 2.1A( rms)max. for 115VAC 1.1A( rms)max. for 230VAC 0.3mA max. @ 115VAC, 60Hz 0.6mA max. @ 230VAC, 50Hz E N V IR O N M ENTA L SP E C IF ICATI O N S Operating temperature: Storage temperature: Relative humidity: Derating: Cooling: OUTPUT SPECIFICATIONS Output voltage/current: See Rating Chart Ripple and noise: 65mV peak to peak on V1,1% peak to peak on other outputs Overvoltage protection: Provided on V0 & V1; set at 112–132% of its nominal output voltage Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04/ºC maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change PG/PFD signal: TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 10ms prior to master output dropping 5% below its nominal value. This signal also provides a minimum delay of 100ms after master output is within regulation -10ºC to +60ºC -40ºC to +85ºC 5% to 95% non-condensing Derate from 100% at +40ºC linearly to 50% at +60ºC 10 CFM total forced air from two 40mm diameter fans or the like is required a n d p r o v i d e d b y u s e r. GENERAL SPECIFICATIONS Switching frequency: Power factor: Efficiency: Hold-up time: Line regulation: Inrush current: 100KHz ±10KHz 0.98 typical 75% typical 15 msec minimum at 115VAC ±0.5% maximum at full load 35 amps @ 115VAC or 70 amps @ 230VAC at 25ºC cold start Withstand voltage: 3000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 200,000 hours minimum EMC Performance (EN55024) EN55022: Class B conducted, class A radiated FCC Part 15 Class B conducted, class A radiated VCCI: Class B conducted, class A radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±4KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, ±1KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 1A/m E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms and >95% reduction for 10ms Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com UNIVERSAL INPUT TFC130 SERIES OUTPUT VOLTAGE/CURRENT RATING CHART (1)(2) (5)(6) Product No. V1(3) V2 5CFM 10CFM 5CFM 10CFM Vnom. Imax.Imax. Tol. Vnom. Imax. Imax. Tol. TFC130-D23-3 +5.1V TFC130-D23 +5.1V 8A 12A 2% 8A 12A 2% (N/A) +12V 3.25A 6A 3% TFC130-D24 +5.1V TFC130-D25 +5.1V 8A 12A 2% 8A 12A 2% +24V 1.63A 3A 3% TFC130-T31 +5.1V +5.1V 8A 12A 2% 8A 12A 2% +12V 3.25A TFC130-T32 +15V TFC130-T33 +5.1V TFC130-T34 +5.1V TFC130-T35 +5.1V TFC130-T36 8A 12A 2% 8A 12A 2% +15V 2.6A 4.8A 3% Vnom. V3 (4) V4 (4) 5CFM 10CFM 5CFM 10CFM Imax.Imax.Tol. Vnom. (N/A) (N/A) VO 5CFM 10CFM Imax.Imax. Tol. Vnom. Imax. Imax. Tol. (N/A) (N/A) 2% +3.3V 8A 12A (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 6A 3% +5V~+24V 0.5A 1A 2% (N/A) (N/A) 2.6A 4.8A 3% +5V~+24V 0.5A 1A 2% (N/A) (N/A) +24V 1.63A 3A 3% +5V~+24V 0.5A 1A 2% +12V 3.25A 6A 3% (N/A) –5V~–24V 0.5A 1A 2% (N/A) 2.6A 4.8A 3% (N/A) –5V~–24V 0.5A 1A 2% (N/A) –5V~–24V 0.5A 1A 2% (N/A) (N/A) +15V +5.1V 8A 12A 2% 8A 12A 2% +24V 1.63A 3A 3% (N/A) TFC130-T31-3 +5.1V TFC130-T33-3 +5.1V 8A 12A 2% 8A 12A 2% +12V 3.25A 6A 3% (N/A) (N/A) +3.3V 8A 12A 2.6A 4.8A 3% (N/A) (N/A) +3.3V 8A 12A 2% TFC130-T39-3 +5.1V TFC130-Q41 +5.1V 8A 12A 2% 8A 12A 2% +24V 1.63A 3A 3% (N/A) (N/A) +3.3V 8A 12A 2% +12V 3.25A 6A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A 2% (N/A) TFC130-Q42 +5.1V +15V 2.6A 4.8A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A 2% (N/A) TFC130-Q43 +5.1V 8A 12A 2% 8A 12A 2% +24V 1.63A 3A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A 2% TFC130-Q41-3 +5.1V TFC130-Q42-3 +5.1V 8A 12A 2% 8A 12A 2% +12V 3.25A 6A 3% +5V~+24V 0.5A 1A 2% (N/A) +3.3V 8A 12A 2% 2.6A 4.8A 3% +5V~+24V 0.5A 1A 2% (N/A) +3.3V 8A 12A 2% TFC130-Q43-3 +5.1V TFC130-Q44-3 +5.1V 8A 12A 2% 8A 12A 2% (N/A) +3.3V 8A 12A 2% TFC130-Q45-3 +5.1V TFC130-Q46-3 +5.1V 8A 12A 2% 8A 12A 2% +15V +24V 1.63A 3A 3% TFC130-F51-3 +5.1V TFC130-F52-3 +5.1V 8A 12A 2% 8A 12A 2% +12V 3.25A TFC130-F53-3 +5.1V 8A 12A 2% +24V 1.63A +15V +15V (N/A) 2% (N/A) +24V 1.63A 3A 3% +5V~+24V 0.5A 1A 2% +12V 3.25A 6A 3% (N/A) –5V~–24V 0.5A 1A 2% +3.3V 8A 12A 2% 2.6A 4.8A 3% (N/A) –5V~–24V 0.5A 1A 2% +3.3V 8A 12A 2% (N/A) –5V~–24V 0.5A 1A 2% +3.3V 8A 12A 2% 6A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A 2% +3.3V 8A 12A 2% 2.6A 4.8A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A 2% +3.3V 8A 12A 2% 2% +3.3V 8A 12A 2% +15V 3A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A NOTES: 1. The outputs of each model are from two independent channels. Channel #1 consists of the main output V1 and auxiliary output V0. Channel #2 consists of the main output V2 and auxiliary outputs V3 and V4. The maximum output power that may be drawn from each channel is 45W with 5 CFM forced-air cooling or 65W with 10 CFM forced-air cooling. The derating curve on right provides guidelines on application within the specified operating temperature range. 2. “5 CFM Imax.” (“10 CFM Imax.”) is the maximum current of individual output when 5 CFM (10 CFM) forced air is provided. Under a specific cooling condition, both the maximum output power stated in note #1 and the maximum current of individual output must not be exceeded. 3. V1 needs a minimum current of 0.8A to support output V0 at its maximum rated load. 4. The total output power of V3 and V4 should not exceed 30W. V3 is adjustable between +5V and +24V, and set at +12V as standard. V4 is adjustable between –5V and –24V, and set at –12V as standard. It is welcome to consult factory for the two outputs to be set at wanted voltages within the adjustable ranges. 5. Ripple and noise measured peak to peak across a 20MHz bandwidth by using a 12 inch twisted pair terminated with a 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor. 6. “Tol.” Is output voltage tolerance which includes initial set-up error, thermal drift, line regulation, load regulation and cross regulation. Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com UNIVERSAL INPUT TFC130 SERIES MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Connector P1 mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Connectors P2 and P4 are suitable for AWG#18~AWG#12 electric wires. 5. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal. 6. Weight: 0.43 kgs. (0.95 lbs.) approx. 7. Potentiometers for output voltage adjustments: VR1 for V1, VR2 for V0, VR3 for V3, VR4 for V4 (VR3 and VR4 being SMD type on trace side) PIN CHART P1 CONN Product No. PIN TFC130-D23-3 TFC130-D23 TFC130-D25 TFC130-D24 TFC130-T31 TFC130-T33 TFC130-T32 TFC130-T34 TFC130-T36 TFC130-T31-3 TFC130-T39-3 TFC130-T35 TFC130-Q41 TFC130-Q43 TFC130-Q42 1 P2 2 1 2 3 V3 AC AC COM. COM. V1 LIVE NEUTRAL RET. RET. TFC130-F52-3 5 6 N.C. N.C. V2 AC AC COM. COM. V1 LIVE NEUTRAL RET. RET. 2 3 4 1 2 -SENSE +SENSE COM. VO RET (VO) (VO) PG/PFD COM. Signal RET. N.C. N.C. VOID N.C. V4 N.C. V2 N.C. N.C. N.C. V4 V3 V4 V2 V2 VO FAN V3 N.C. VOID PG/PFD COM. Signal RET. -SENSE +SENSE (VO) (VO) V4 AC AC COM. COM. V1 LIVE NEUTRAL RET. RET. 1 P4 N.C. N.C. TFC130-Q44-3 TFC130-Q45-3 TFC130-Q46-3 TFC130-F51-3 TFC130-F53-3 4 AC AC COM. COM. V1 N.C. LIVE NEUTRAL RET. RET. TFC130-T33-3 TFC130-Q41-3 TFC130-Q42-3 TFC130-Q43-3 P3 -SENSE +SENSE (VO) (VO) COM. RET. VOID PG/PFD COM. Signal RET. VO COM. RET. -SENSE +SENSE PG/PFD COM. VO Signal RET. (VO) (VO) COM. RET. Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com