TRUMPOWER TFC130M

TRUMPower
PFC 130 WATT POWER SUPPLIES
D E SCR IPTION
TFC130 SERIES
The TFC130 series incorporates creative high
efficiency circuitry, high power density (6.94
3
Watts/in ) and active Power Factor Correction
(PFC) to meet the requirements of data
networking, computing and telecommunication
systems. Some models with one or two outputs
adjustable between 5V and 24V intend to suit
more applications.
(MULTIPLE OUTPUT)
(LVD)
RoHS
F EATU R E S
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
EN61000-3-2 class A and D compliant
Pow er factor 0.98 typical
Ve r y c o m pa c t s i z e , 3 ″ × 5 ″ × 1 . 2 ″
O v e r v o l ta g e p r o t e c t i o n
Short circuit protection
Remote sense on 3.3V output
Pow er Good/Pow er Fail Detect Signal
U p t o f i v e D C o u t p u ts
A l l o u t p u ts w e l l r e g u l a t e d
C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
Saf et y Sta n da rd A ppr o va ls:
UL 60950 3rd
CSA C22.2 No. 60950 3rd
TÜV EN60950-1
IN PUT S PE C IF ICAT ION S
Input voltage:
Input frequency:
Input current:
Earth leakage current:
(Touch Current)
90 to 264VAC
47 to 63Hz
2.1A( rms)max. for 115VAC
1.1A( rms)max. for 230VAC
0.3mA max. @ 115VAC, 60Hz
0.6mA max. @ 230VAC, 50Hz
E N V IR O N M ENTA L SP E C IF ICATI O N S
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Cooling:
OUTPUT SPECIFICATIONS
Output voltage/current:
See Rating Chart
Ripple and noise:
65mV peak to peak on V1,1%
peak to peak on other outputs
Overvoltage protection: Provided on V0 & V1; set at
112–132% of its nominal
output voltage
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04/ºC maximum
Transient response:
Maximum excursion of 4%
or better on all models,
recovering to 1% of final
value within 500µs after
a 25% step load change
PG/PFD signal:
TTL logic high for normal
operation and TTL logic low
upon loss of input power.
This signal appears at least
10ms prior to master output
dropping 5% below its
nominal value. This signal
also provides a minimum
delay of 100ms after master
output is within regulation
-10ºC to +60ºC
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +40ºC
linearly to 50% at +60ºC
10 CFM total forced air
from two 40mm diameter
fans or the like is required
a n d p r o v i d e d b y u s e r.
GENERAL SPECIFICATIONS
Switching frequency:
Power factor:
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
100KHz ±10KHz
0.98 typical
75% typical
15 msec minimum at 115VAC
±0.5% maximum at full load
35 amps @ 115VAC or 70 amps
@ 230VAC at 25ºC cold start
Withstand voltage:
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
200,000 hours minimum
EMC Performance (EN55024)
EN55022:
Class B conducted, class A radiated
FCC Part 15
Class B conducted, class A radiated
VCCI:
Class B conducted, class A radiated
EN61000-3-2:
Harmonic distortion, class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ±1KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
E N 6 1 0 0 0 - 4 - 11 :
Voltage dips, 30% reduction for
500ms and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
UNIVERSAL INPUT
TFC130 SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
(1)(2)
(5)(6)
Product No.
V1(3)
V2
5CFM 10CFM
5CFM 10CFM
Vnom. Imax.Imax. Tol. Vnom. Imax. Imax. Tol.
TFC130-D23-3 +5.1V
TFC130-D23
+5.1V
8A 12A 2%
8A 12A 2%
(N/A)
+12V 3.25A
6A 3%
TFC130-D24
+5.1V
TFC130-D25
+5.1V
8A 12A 2%
8A 12A 2%
+24V 1.63A
3A 3%
TFC130-T31
+5.1V
+5.1V
8A 12A 2%
8A 12A 2%
+12V 3.25A
TFC130-T32
+15V
TFC130-T33
+5.1V
TFC130-T34
+5.1V
TFC130-T35
+5.1V
TFC130-T36
8A 12A 2%
8A 12A 2%
+15V
2.6A 4.8A 3%
Vnom.
V3 (4)
V4 (4)
5CFM 10CFM
5CFM 10CFM
Imax.Imax.Tol.
Vnom.
(N/A)
(N/A)
VO
5CFM 10CFM
Imax.Imax. Tol. Vnom. Imax. Imax.
Tol.
(N/A)
(N/A)
2%
+3.3V
8A 12A
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
6A 3% +5V~+24V 0.5A 1A 2%
(N/A)
(N/A)
2.6A 4.8A 3% +5V~+24V 0.5A 1A 2%
(N/A)
(N/A)
+24V 1.63A
3A 3% +5V~+24V 0.5A 1A 2%
+12V 3.25A
6A 3%
(N/A)
–5V~–24V 0.5A 1A
2%
(N/A)
2.6A 4.8A 3%
(N/A)
–5V~–24V 0.5A 1A
2%
(N/A)
–5V~–24V 0.5A 1A
2%
(N/A)
(N/A)
+15V
+5.1V
8A 12A 2%
8A 12A 2%
+24V 1.63A
3A 3%
(N/A)
TFC130-T31-3 +5.1V
TFC130-T33-3 +5.1V
8A 12A 2%
8A 12A 2%
+12V 3.25A
6A 3%
(N/A)
(N/A)
+3.3V
8A 12A
2.6A 4.8A 3%
(N/A)
(N/A)
+3.3V
8A 12A
2%
TFC130-T39-3 +5.1V
TFC130-Q41 +5.1V
8A 12A 2%
8A 12A 2%
+24V 1.63A
3A 3%
(N/A)
(N/A)
+3.3V
8A 12A
2%
+12V 3.25A
6A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A
1A
2%
(N/A)
TFC130-Q42
+5.1V
+15V
2.6A 4.8A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A
1A
2%
(N/A)
TFC130-Q43
+5.1V
8A 12A 2%
8A 12A 2%
+24V 1.63A
3A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A
1A
2%
TFC130-Q41-3 +5.1V
TFC130-Q42-3 +5.1V
8A 12A 2%
8A 12A 2%
+12V 3.25A
6A 3% +5V~+24V 0.5A 1A 2%
(N/A)
+3.3V
8A 12A
2%
2.6A 4.8A 3% +5V~+24V 0.5A 1A 2%
(N/A)
+3.3V
8A 12A
2%
TFC130-Q43-3 +5.1V
TFC130-Q44-3 +5.1V
8A 12A 2%
8A 12A 2%
(N/A)
+3.3V
8A 12A
2%
TFC130-Q45-3 +5.1V
TFC130-Q46-3 +5.1V
8A 12A 2%
8A 12A 2%
+15V
+24V 1.63A
3A 3%
TFC130-F51-3 +5.1V
TFC130-F52-3 +5.1V
8A 12A 2%
8A 12A 2%
+12V 3.25A
TFC130-F53-3 +5.1V
8A 12A 2%
+24V 1.63A
+15V
+15V
(N/A)
2%
(N/A)
+24V 1.63A
3A 3% +5V~+24V 0.5A 1A 2%
+12V 3.25A
6A 3%
(N/A)
–5V~–24V 0.5A 1A
2% +3.3V
8A 12A
2%
2.6A 4.8A 3%
(N/A)
–5V~–24V 0.5A 1A
2% +3.3V
8A 12A
2%
(N/A)
–5V~–24V 0.5A 1A
2% +3.3V
8A 12A
2%
6A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A
2% +3.3V
8A 12A
2%
2.6A 4.8A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A
2% +3.3V
8A 12A
2%
2% +3.3V
8A 12A
2%
+15V
3A 3% +5V~+24V 0.5A 1A 2% –5V~–24V 0.5A 1A
NOTES:
1. The outputs of each model are from two independent channels. Channel
#1 consists of the main output V1 and auxiliary output V0. Channel #2
consists of the main output V2 and auxiliary outputs V3 and V4. The
maximum output power that may be drawn from each channel is 45W
with 5 CFM forced-air cooling or 65W with 10 CFM forced-air cooling.
The derating curve on right provides guidelines on application within the
specified operating temperature range.
2. “5 CFM Imax.” (“10 CFM Imax.”) is the maximum current of individual
output when 5 CFM (10 CFM) forced air is provided. Under a specific
cooling condition, both the maximum output power stated in note #1 and
the maximum current of individual output must not be exceeded.
3. V1 needs a minimum current of 0.8A to support output V0 at its maximum
rated load.
4. The total output power of V3 and V4 should not exceed 30W. V3 is adjustable between +5V and +24V, and set at +12V as standard.
V4 is adjustable between –5V and –24V, and set at –12V as standard. It is welcome to consult factory for the two outputs to be set
at wanted voltages within the adjustable ranges.
5. Ripple and noise measured peak to peak across a 20MHz bandwidth by using a 12 inch twisted pair terminated with a 10µF
tantalum capacitor in parallel with a 0.1µF ceramic capacitor.
6. “Tol.” Is output voltage tolerance which includes initial set-up error, thermal drift, line regulation, load regulation and cross
regulation.
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
UNIVERSAL INPUT
TFC130 SERIES
MECHANICAL SPECIFICATIONS
NOTES:
1.
Dimensions shown in inch [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Connector P1 mates with Molex housing
09-50-3031 and Molex 2878 series crimp terminal.
4.
Connectors P2 and P4 are suitable for
AWG#18~AWG#12 electric wires.
5.
Connector P3 mates with Molex housing
22-01-1043 and Molex 40445 series crimp
terminal.
6.
Weight: 0.43 kgs. (0.95 lbs.) approx.
7.
Potentiometers for output voltage adjustments:
VR1 for V1, VR2 for V0, VR3 for V3, VR4 for V4
(VR3 and VR4 being SMD type on trace side)
PIN CHART
P1
CONN
Product No.
PIN
TFC130-D23-3
TFC130-D23
TFC130-D25
TFC130-D24
TFC130-T31
TFC130-T33
TFC130-T32
TFC130-T34
TFC130-T36
TFC130-T31-3
TFC130-T39-3
TFC130-T35
TFC130-Q41
TFC130-Q43
TFC130-Q42
1
P2
2
1
2
3
V3
AC
AC
COM. COM.
V1
LIVE NEUTRAL
RET. RET.
TFC130-F52-3
5
6
N.C.
N.C.
V2
AC
AC
COM. COM.
V1
LIVE NEUTRAL
RET. RET.
2
3
4
1
2
-SENSE +SENSE
COM.
VO
RET
(VO)
(VO)
PG/PFD COM.
Signal RET.
N.C.
N.C.
VOID
N.C.
V4
N.C.
V2
N.C.
N.C.
N.C.
V4
V3
V4
V2
V2
VO
FAN
V3
N.C.
VOID
PG/PFD COM.
Signal RET.
-SENSE +SENSE
(VO)
(VO)
V4
AC
AC
COM. COM.
V1
LIVE NEUTRAL
RET. RET.
1
P4
N.C.
N.C.
TFC130-Q44-3 TFC130-Q45-3
TFC130-Q46-3
TFC130-F51-3
TFC130-F53-3
4
AC
AC
COM. COM.
V1
N.C.
LIVE NEUTRAL
RET. RET.
TFC130-T33-3
TFC130-Q41-3 TFC130-Q42-3
TFC130-Q43-3
P3
-SENSE +SENSE
(VO)
(VO)
COM.
RET.
VOID
PG/PFD COM.
Signal RET.
VO
COM.
RET.
-SENSE +SENSE PG/PFD COM.
VO
Signal RET.
(VO)
(VO)
COM.
RET.
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com