AC-DC 120-480 Watts xppower.com DNR120-480 Series • Up to 90% Efficiency • Wide Adjustment Range • Three-phase 480 W Versions • Parallel Function • DC Standby Versions • Full Power to +60 °C • Connector Options Specification Input General Input Voltage • DNR120LS: 93-132/186-264 VAC switch select, 210-370 VDC switch in 230 VAC position DNR120AS: 90-132/186-264 VAC auto select, 210-370 VDC DNR240PS: 93-132/186-264 VAC, auto select, 210-370 VDC DNR480PS: 90-264 VAC, 120-370 VDC DNR480TS: 340-575 VAC 3Ø, 480-820 VDC Input Frequency • 47-63 Hz Inrush Current • 120 W: 24/48 A at 115/230 VAC 240 W: 30/60 A at 115/230 VAC 480PS: 25/50 A at 115/230 VAC 480TS: 33 A at 575 VAC Power Factor • Meets EN61000-3-2 for class A equipment Earth Leakage Current • 0.8 mA max Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time • • • • • • • Line Regulation Load Regulation • • Transient Response Ripple & Noise • • Overvoltage Protection • Overload Protection • Temperature Coefficient • See tables See tables ±1% No minimum load required <1000 ms <150 ms 120 & 240 W: 25/30 ms at 115/230 VAC 480PS: 30 ms at 115/230 VAC 480TS: 20 ms at 340 VAC ±0.5% max (±1% max for 480TS) ±1% (±5% for units in parallel), 120LS models - see note 1 300 µs for a 50% load change 120 W models: 50 mV pk-pk 240-480 W models: 100 mV pk-pk. 20 MHz BW Output clamps at 125-145% Vnom 105-145% constant current. 480TS model: 115-135% continuous power limit, Imax = 2 x Inom at short circuit condition or switchable trip and restart mode, output is turned on for 3 s every 30 s. ±0.02%/°C Efficiency Isolation Switching Frequency Signals MTBF • See tables • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 100 KHz typical • DC ON indicator LED Green, DC LOW indicator LED Red DC OK: 24 V models • 200 kHrs typical per MIL-HDBK-217F GF, +40 °C Environmental Operating Temperature • DNR120-240: -10 °C to +70 °C, derate linearly from +60 °C at 2.5%/°C DNR480 PS: -25 °C to +70 °C, derate linearly from +55 °C at 2.5%/°C DNR480 TS: -25 °C to +70 °C, derate linearly from +60 °C at 2.5%/°C. (see derating curves) Cooling • Convection-cooled Operating Humidity • 20-95% RH, non-condensing Storage Temperature • -25 °C to +85 °C Shock • 4 g, 22 ms, X, Y & Z axis Vibration • 1 g, 10 Hz to 500 kHz, along X, Y & Z axis EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals EN55022, class B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, level 3 Perf Criteria A EN61000-4-3, level 3 Perf Criteria A EN61000-4-4, level 3 Perf Criteria A EN61000-4-5, level 3 Perf Criteria A EN61000-4-6, level 3 Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B • EN60950-1:2001, UL508, UL60950-1, cUL60950-1, CE Mark • • • • • • • • • Output Voltage 12 V 24 V 48 V 12 V 24 V 48 V 24 V 48 V 24 V 48 V 24 V 48 V AC-DC DNR120-480 Models and Ratings Output Voltage Trim 11.4-14.5 V 22.5-30.0 V 45.0-55.0 V 11.4-14.5 V 22.5-30.0 V 45.0-55.0 V 22.5-28.5 V 47.0-56.0 V 22.5-28.5 V 47.0-56.0 V 22.5-28.5 V 47.0-56.0 V Output Current 10.0 A 5.0 A 2.5 A 10.0 A 5.0 A 2.5 A 10.0 A 5.0 A 20.0 A 10.0 A 20.0 A 10.0 A Typical Efficiency 84% 86% 87% 84% 86% 87% 89% 90% 89% 90% 88% 89% Model Number DNR120LS12(1,2,3) DNR120LS24(1,2,3) DNR120LS48(1,2,3) DNR120AS12-I(3,4) DNR120AS24-I(3,4) DNR120AS48-I(3,4) DNR240PS24-I†(3,4) DNR240PS48-I†(3,4) DNR480PS24-I(3,4) DNR480PS48-I(3,4) DNR480TS24-I DNR480TS48-I Notes 1. Add suffix ‘-I’ to DNR120LS model number for parallel function, (120AS, 240 & 480 W models have parallel function as standard). A maximum of 3 units can be paralleled. Total power available is 90% of the rated current of each unit. 2. For PFC version of DNR120LS, replace ‘L’ in the model number with ‘P’ e.g. DNR120LS24 becomes DNR120PS24 (Typical power factor 0.7). 3. Add suffix ‘-D’ for detachable connector option. 4. For DC standby, remove ‘-I’ and add # to the end of the model number. † Available from Farnell. See pages 204-206. Derating Curves DNR120-240 DNR480PS DNR480PS DNR480PS DNR120 & 240 DNR480TS DNR480TS DNR480TS DNR480PS 100 100 80 80 80 80 80 80 80 80 60 60 60 60 60 60 60 60 40 20 0 0 -10 10 40 20 0 20 40 20 20 0 30 10-10 20 40 0 30 10 50 40 20 60 50 30 70 0 60 40 70 50 70 60 40 -25 -20 40 20 0 -10-25 -200 0 030 50 104060 205070 3060 4070 50 60 40 20 20 20 -2010 30 -1020 40 0-25 -1010 Temp (˚C) Ambient Temp (˚C) Ambient TempAmbient (˚C) 40 0 70 -25 -20 0 -10-25 -200 Temp (˚C) Ambient Temp (˚C) Ambient TempAmbient (˚C) Load (%) 100 Load (%) 100 Load (%) 100 Load (%) 100 Load (%) 100 Load (%) 100 Load (%) Load (%) DNR120 & 240 DNR120 & 240 DNR480TS 40 20 0 -1010 20 -201030 -1020 40 0-25 50 104060 205070 3060 030 Temp (˚C) Ambient Temp (˚C) Ambient TempAmbient (˚C) Standby Versions + + DC OK 1 6 Output Set Voltages For Standby Versions K1 DC OK DC LO ON D1 K1 Fuse LOAD RL > 700ohm DCOK - Battery 22K DCOK 0.5W Model Voltage Current DC OK Shutoff DNR120AS12# 13.6 V 8.8 A 10.8 V ±5% DNR120AS24# 27.2 V 4.4 A 21.6 V ±5% DNR120AS48# 54.5 V 2.2 A 43.2 V ±5% DNR240PS24# 27.2 V 8.8 A 21.6 V ±5% DNR240PS48# 54.5 V 4.4 A 43.2 V ±5% DNR480PS24# 27.2 V 17.6 A 21.6 V ±5% DNR480PS48# 54.5 V 8.8 A 43.2 V ±5% - 1 3 -Vout 5.1K 0.3W Maximum current drain from battery -Vout by PSU when inactive 22 mA. a) Relay Example b) 5 V Signal Example DC OK Volt free contact closed when good voltage from PSU or battery available to the load in standby system Available on 24 V models only. DCOK Open = Output fail Closed = Output good DCOK Contact Rating: 0.3 A at 60 VDC 500 VDC isolation 4070 50 60 AC-DC DNR120-480 Mechanical Details DNR120LS Models DC Output DC Output 6 4.57 (116.0) 0.39 (10.0) 1 6 1 DC LO ON DC LO ON 4.92 (125.0) ‘-D’ option 115 VAC 115 VAC 230 VAC 230 VAC 1 3 5.59 (142.0) AC Input 1 3 AC Input 2.50 (63.5) DNR120 Connections Pin Designation 1 Ground AC 2 Line Input 3 Neutral 1 DC OK * 2 DC OK * DC 3 Positive 4 Positive Output 5 Negative 6 Negative Conn Notes 1. All dimensions in inches (mm). 2. Weight 1.4 lb (630 g) approx. 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. * 24 V & standby models only. 240 W Models DNR120AS Models DC Output DC Output 6 4.57 (116.0) 6 0.39 (10.0) 1 1 Single Parallel Single Parallel DC LO ON DC LO ON 4.92 (125.0) ‘-D’ option 5.59 (142.0) 1 3 AC Input 1 3 AC Input 2.50 (63.5) DNR120 Connections Pin Designation 1 Ground AC 2 Line Input 3 Neutral 1 DC OK * 2 DC OK * DC 3 Positive 4 Positive Output 5 Negative 6 Negative Conn Notes 1. All dimensions in inches (mm). 2. Weight 1.4 lb (630 g) approx. 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. * 24 V & standby models only. 240 W Models 0.39 (10.0) 4.57 (116.0) DC Output 6 1 DC Output 1 6 Single Single Parallel Parallel DC LO ON DC LO ON 4.92 (125.0) 5.59 (142.0) ‘-D’ option 1 AC Input 3 1 AC Input 3 3.27 (83.0) DNR240 Connections Pin Designation 1 Ground AC 2 Line Input 3 Neutral 1 DC OK* 2 DC OK* DC 3 Positive 4 Positive Output 5 Negative 6 Negative Conn Notes 1. All dimensions in inches (mm). 2. Weight 3.0 lb (1360 g) approx. The red LED is lit if the output 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. voltage is 70-90% of VNOM 240 W Models 480 * 24 V & standby models only. The green LED is lit if the output voltage is >75% of VNOM A C 0.3 (7.0) B D DC ON AC Input 1 DC LO DC Output 3 1 6 Optional detachable connector (‘-D’ option) ‘PS’ version AC Input 1 DC Output 4 DC OK DC LO DC ON 1 4 ‘TS’ version Notes 1. All dimensions in inches (mm). 2. Weight 4.2 lb (1920 g) approx. 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. Single/parallel & current limit selector switches on underside A B C D DNR480 Dimensions 480PS 480TS 6.89 (175.0) 5.91 (150.0) 4.92 (125.0) 4.87 (123.6) 4.57 (116.0) 4.38 (111.3) 5.59 (142.0) DNR480PS Connections Conn Pin Designation 1 Ground AC 2 Neutral Input 3 Line 1 DC OK* 2 DC OK* DC 3 Positive 4 Positive Output 5 Negative 6 Negative DNR480TS Connections Conn Pin Designation 1 Ground AC 2 L1 3 L2 Input 4 L3 1 Positive DC 2 Positive 3 Negative Output 4 Negative 1 DC OK* DC OK 2 DC OK* * 24 V and standby models only. 09-Oct-07 AC-DC DNR120-480 Mechanical Details