NFS200 SERIES Triple and quad output • • • • • • • • The NFS200 series is a 200W universal input AC/DC power supply in a 5 x 9 x 2.5 inch package. The NFS200 series has four multiple output models and has proven itself to be highly reliable and versatile product for a wide range of communication and industrial applications, with a very high peak capability on the auxiliary outputs for drive and motor applications. The NFS200 provides 200W of output power with 30CFM of air. Standard features include overvoltage and short circuit protection, adjustable outputs, isolated outputs and power fail detect. The series, with full international safety approval and the CE mark, meets conducted emissions EN55022 level A. The NFS200 series is designed for use in medium power data networking, computer, telecom and industrial applications such as servers, PABX's, printers and process automation. Patent No. 4912620 [ 2 YEAR WARRANTY ] SPECIFICATION 5.0 x 9.0 x 2.5 inch package Overvoltage and short circuit protection 200W with 30CFM Adjustable outputs Isolated outputs Power fail detect signals EN55022, EN55011 conducted emissions level A UL, VDE, CSA and BABT safety approvals All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage adjustability +5V output ±5.0% Line regulation LL to HL, FL Main output ±0.1% max. Load regulation Main output Auxiliary outputs ±2.0% max. ±2.5% max. Overshoot/undershoot At turn-on Transient response +5V (20A to 30A step) Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. Level A Level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 0% GENERAL SPECIFICATIONS ±200mV max. dev. 500µs recovery to 1.0% Hold-up time 110VAC After PFD flag @ 200W 15ms 5ms Temperature coefficient All outputs ±0.02%/°C Efficiency 110/230VAC @ 200W 70% typ. Overvoltage protection 6.25V±0.5V Isolation voltage Input/output Input/chassis 3000VAC 1500VAC Switching frequency Variable +5V output Short circuit protection Fan output current (See Note 8) Yes, with auto-recovery J1: pins 3 and 4 Standards and approvals (See Note 9) INPUT SPECIFICATIONS Input voltage range Universal input 90VAC to 264VAC 130VDC to 370VDC VDE0805, EN60950, IEC950 IEC1010, UL1950, BABT CSA C22.2 No. 950 Weight MTBF (See Note 1) Input frequency range 80 to 100kHz 12.1V @ 0.75A max. 1.34kg (47.30oz) MIL-HDBK-217E 84,000 hours 47Hz to 63Hz ENVIRONMENTAL SPECIFICATIONS Input surge current Safety ground leakage current PAGE 1 110VAC, 60Hz 230VAC, 50Hz 40A max. 80A max. 110VAC, 60Hz 230VAC, 50Hz 0.9mA max. 1.6mA max. Thermal performance (See Notes 3, 10) Operating 0°C to +70°C Non-operating -40°C to +85°C 0°C to 50°C ambient, 200W 30CFM forced air 50°C to 70°C ambient, Derate linearly 30CFM forced air to 100W at 70°C Relative humidity Non-condensing Altitude Operating Non-operating Vibration Three orthogonal axes, random vibration, 10 minute test for each axis 5% to 95% RH 10,000 feet max. 40,000 feet max. 2.4G rms 5 to 500Hz LOW TO MEDIUM POWER AC/DC POWER SUPPLIES | 200W AC/DC 200 Watt AC/DC universal input switch mode power supplies OUTPUT CURRENTS OUTPUT VOLTAGE (1) MIN PEAK (2) MAX (3) RIPPLE (4) TOTAL REGULATION (5) +5.1V 5.0A 30A 30.0A 50mV ±2% +12.1V 0A 12A 8.0A 120mV ±2.5% –12.1V 0A 5.0A 4.0A 120mV ±2.5% 0A 6.0A 6.0A 50mV ±2.5% +5.1V 5.0A 30A 30.0A 50mV ±2% +12.1V 0A 12A 8.0A 120mV ±2.5% –12.1V 0A 5.0A 4.0A 120mV ±2.5% 0A 3.0A 3.0A 240mV ±2.5% +5.1V 5.0A 30A 30.0A 50mV ±2% +12.1V 0A 12A 8.0A 120mV ±2.5% –12.1V 0A 5.0A 4.0A 120mV ±2.5% 0A 4.0A 4.0A 120mV ±2.5% +5.1V 5.0A 30A 30A 50mV ±2.5% +12.1V 0A 12.0A 8.0A 120mV ±2.5% -12.1V 0A 5.0A 4.0A 120mV ±2.5% –5.2V 24.0V 12.0V (6) (7) (7) NFS200-7601 NFS200-7602 NFS200-7603 NFS200-7608 Term 1 AC Line AC Line AC Line AC Line Term 2 AC Neutral AC Neutral AC Neutral AC Neutral Safety Ground Safety Ground Safety Ground Safety Ground TB2 Term 1 +5.1V +5.1V +5.1V +5.1V Term 2 +5.1V +5.1V +5.1V +5.1V Term 3 Return Return Return Return Term 4 Return Return Return Return Term 5 Return Return Return Return Term 6 +12.1V +12.1V +12.1V +12.1V Term 7 –12.1V –12.1V –12.1V –12.1V Term 8 –5.2V(6) Term 9 –5.2V Return(6) 24V +24V(7) 12V CASED NFS200-7601 (6) NFS200-7601CF (6) NFS200-7602 (7) NFS200-7602CF (7) NFS200-7603 (7) NFS200-7603CF (7) NFS200-7608 NFS200-7608CF 1 TB1 Return(7) OPEN FRAME (A) Notes PIN CONNECTIONS Term 3 MODEL NUMBER 25W minimum total output load required for reliable operation. Also, ±12V output peak current capability requires a +5.1V @ 5A minimum load. 2 Peak output current lasting less than 30 seconds with duty cycle less than 10%. During peak loading, outputs may drift outside total regulation limits. 3 Requires forced air, 30CFM minimum, or 350LFM. 4 Figure is peak-to-peak. Output noise is measured across a 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor. 5 Total regulation is defined as the static output regulation at 25°C, including initial tolerance, line voltage within stated limits, load currents within stated limits, and output voltages adjusted to their factory settings. 6 Although the –5.2V return is electrically connected to the ‘main’ return (terminals 3, 4 and 5, which are all connected together), Artesyn Technologies recommends that system cabling allow –5.2V return current flow to terminal 9. 7 The auxiliary output is floating, and can be referenced as either positive or negative. The return is the negative terminal of the pair. 8 Any fan current must be subtracted from the total available +12.1V current. Supplied fans draw 0.14A. 9 This product is only for installation by professional installers within other equipment and must not be operated as a stand alone product. 10 Derating curve is application specific for ambient temperatures >50°C, for optimum reliability no part of the heat sink should exceed 90°C and no semi-conductor temperature should exceed 100°C. Return(7) +12V(7) International Safety Standard Approvals Term 10 VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1058 Licence No. 3613 J1 Pin 1 PFD PFD PFD PFD Pin 2 PFD Return PFD Return PFD Return PFD Return Pin 3 Fan Return Fan Return Fan Return Fan Return Pin 4(8) Fan Fan Fan Fan http://www.artesyn.com UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Certificate No. PS/603176 PAGE 2 200W AC/DC | LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 200 Watt AC/DC universal input switch mode power supplies Mechanical notes AC (TB1) connector A A standard cover and fan assembly can be added during manufacturing. Details are on page 84. To order, add suffix ‘CF’’ to the model number. e.g. NFS200-7601CF. Kulka P/N 4597A-6/32-03 or equivalent DC (TB2) connector Kulka P/N 4597A-6/32-09 or equivalent J1 mating connector Molex 22-01-1043 or equivalent with 4809 series or equivalent crimp terminal 0.30 (7.62) 1.00 (25.4) 8-32 Screw Thread (4 Places) Preferred Air-flow Direction 2.5 1.800 (63.5) (45.72) TB2 Term. 1 1.00 (25.4) 7.00 (177.8) 0.79 (20.07) L2 C7 + 5V Adjust T1 TB1 Term 1 J1 Pin 1 on Top Line Neutral 3.530 5.00 (89.66) (127) Ref. 8-32 Screw Thread (4 Places) Max. Screw Penetration From Bottom of Chassis 0.250 (6.35) F1 C6 Ground 9.00 (229) REF ALL DIMENSIONS IN INCHES (mm) DERATING CURVE Output Power (Watts) 200W FORCED AIR COOLING 100W 25W 25W MINIMUM LOAD REQUIRED 0W 0°C 10°C PAGE 3 20°C 30°C 40°C 50°C 60°C 70°C POWER FAIL DETECT SIGNAL 50ms≤T1≤200ms T2 will vary with line and load T3≥5ms Pout: 200W PFD output is an open collector which will sink ≤40mA in the low state AC INPUT 4.75V 4.75V 5V OUTPUT HIGH PFD SIGNAL 3.5V MIN LOW 0-4 MAX T3 T1 T2 http://www.artesyn.com PAGE 4 DS_NFS200_19980401.PDF Data Sheet © Artesyn Technologies, “REG. U.S. Pat. & Tm. Off”, 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.