ASTEC DS450-3

450-550 Watts 12V
DS450-3/DS550-3
Distributed Power System
Distributed Power Bulk Front-End
450W - 550W
Total Output Power:
+12vdc Main Output
+3.3vdc Stand-By Output
Wide Range Input Voltage: 90 - 264VAC
850 Watts 12V DPS
Input
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Active Power Factor Correction
EN61000-3-2 Harmonic Compliance
Active AC Inrush Control
1U X 2U Form Factor
10.3W / in3 (DS550)
8.4W / in3 (DS450)
+12vdc Output
+3.3vdc Stand-By
No Minimum Load Required
Hot Plug Operation
N + 1 Redundant
Internal OR'ing Fets
Active Current Sharing
Built-in Cooling Fans (40mm x 28mm)
I2C Communication Interface Bus
EERPOM for FRU Data
Amber LED Status, Fan_Fail
Green LED Status, Power Good / AC_OK Status
Internal Fan Speed Control
Fan Fail Tach Output Signal
One Year Warranty
Environmental
Input Range
Frequency
Inrush Current
Efficiency
Conducted EMI
Radiated EMI
Power Factor
Leakage Current
Hold Up Time
90 - 264vac
47 - 63 Hz, single phase AC
15A Maximum
84% typical at full load, high line
FCC Subpart J EN55022 Class A
FCC Subpart J EN55022 Class A
0.99 typical
1.30mA @ 240VAC
20ms Minimum
Main DC Voltage
Stand-By
Adjustment Range
Regulation
+12v
+3.3vsb
Factory Set, no pot adjustments
+12vdc; +5%/-3%
+3.3vsb; +5%/-4%
See Table 1 next page
+12vdc; 13.5 - 15vdc
+3.3vsb; 3.76 - 4.30vdc
+12vdc; 11.0 - 11.5vdc
+3.3vsb; 2.77 - 3.00vdc
1 Second max,
2 - 20mS, Monotonic
Output
Over Current
Over Voltage
Under Voltage
Turn-On Delay
+12vOutput Rise Time
Logic Control
PS Inhibit
PS_Status
AC_Pfail
Operating Temperature: +10°C to 45°C
(50% power derating at 70°C)
Storage Temperature: -40° to +70°C
Altitude, Operating 10,000ft
Electromagnetic Susceptibility / Input Transients:
-EN61000-3-2, -3-3
-EN61000-4-2, 4-4, -4-5, 4-11 Level
-EN55024:1998
Humidity: 20 to 90% RH, non-condensing
Shock and Vibration Specification
(Complies with Astec Std Specification, Q3205
MTBF (Demonstrated): 400KHrs at full load, 40°C
Electrical Specs
Fan_Fault
Tach_1
When supply is inserted into the system the pin is
pulled LOW and power supply is ON after all other pins
are seated
I2C port P6. When the power supply is on and running
normal P6 is low. When the power supply is off, either
due to -PS_ON, PS_KILL, or a fault, then P6 is high.
I2C port P7. P7 is high except when the power supply
turns the main outputs, not +3.3VSB, off due to an AC
failure (AC missing or too low for power supply
operation). If the supply is turned off due to -PS_ON,
PS_KILL, or a fault, then P7 remains high.
The PSU will provides an open collector Tach 1 output.
This signal is generated from the fan. The signal
should generate 2 pulses per revolution. The logic in
the system will be operating at 3.3V.
Safety
UL/cUL 60950 (UL Recognized)
NEMKO+ CB Report EN60950
EN60950
CE Mark
China CCC
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
Rev 1.06.05
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
EUROPE
ASIA
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
Table 1
Output
DS450-3
DS550-3
Nominal Output
Voltage Set Point
Set Point
Tolerance
Total
Regulation
Minimum
Current
Maximum
Current
Output
Ripply P/P
12.0vdc
3.30vsb
+/-0.2%
+/-1%
+5/-3%
+5/-4%
0A
0A
45.0A
3.0A
120mV
60mV
12.0vdc
3.30vsb
+/-0.2%
+/-1%
+5/-3%
+5/-4%
Table 2
DC Output Connector Pinout Assignment
P1 - Power Supply Side
1. FCI Power Blade 51721 series
51721-10002406AA
2. Molex Power Connector
SD-87667 series
87667-7002
Mating Connector (System Side)
1.FCI Power Blade
51741-10002406CC
Strait Pins
2.FCI Power Blade
51761-10002406AA
Right Angle
www.astecpower.com
Pin
PB 1
PB 2
PB 3
PB 4
PB 5
PB 6
A1
A2
A3
A4
A5
A6
B1
B2
B3
B4
B5
B6
C1
C2
C3
C4
C5
C6
D1
D2
D3
D4
D5
D6
0A
0A
37.0A
3.0A
120mV
60mV
Over
Current
39.5 - 44.4A
4.9A Avg, 7A Max
48.0A - 54.0A
4.9A Avg, 7A Max
Male connector as viewed from the rear of the supply:
D1
D2
D3
D4
D5
D6
Signal Name
C1 C2 C3 C4 C5 C6
PB1 PB2 PB3 PB4 PB5 PB6
+12V RETURN
B1 B2 B3 B4 B5 B6
+12V RETURN
A1 A2 A3 A4 A5 A6
+12V RETURN
+12V
+12V
+12V
PS_KILL
+12V CURRENT SHARE
LOGIC RETURN
+3V3 STAND-BY
A0 (I2C Address BIT 0 Signal)
+3V3 STAND-BY
LOGIC RETURN
SPARE
LOGIC RETURN
+3V3 STAND-BY
SDA (I2C Data Signal)
PSON (Power Enable Signal)
LOGIC RETURN
TACH 1 (Fan Fail Signal)
LOGIC RETURN
+3V3 STAND-BY
SCL (I2C Clock Signal)
VIN_GOOD (AC Input Present)
-PS_PRESENT ( Power Supply Seated)
SPARE
LOGIC RETURN
+3V3 STAND-BY
S_INT (Alert)
POK (Output Power Ok)
2
3
NOTE: Dimensions given in (mm).
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
.1496" ±.02"
(3.8 ±0.5)
1.575" ±0.3"
(40.0 ±0.8)
3.071" ±.03"
(78.0 ±0.8)
2.913" ±.024")
(74.0 ±0.6)
2.84"
(72.2)
.228 ±.02
(5.8 ±0.5)
.197" ±.02"
(5.0 ±0.5)
1.51" ±.03"
(38.4 ±0.8)
3.07"
(78.0)
1.52"
(38.4)
J
.972" ±0.2"
24.7 ±0.5
H
STD AIRFLOW
(3X) 254.6
10.02"
(254.6)
11.925" ±0.3"
(302.9 ±0.8)
K
13.29"
(337.6)
12.03"±0.3"
(305.6 ±0.8)
10.88"
(276.4)
10.02"
(254.7)
(3X) 10.02"
(254.7)
(2X)
41.5 LATCH SPRING
DISTANCE (REF.)
G
F
F
F
F
E
3.0 ±0.3
C
B
1.453"
(36.9)
D
.138" ±.020"
(3.5 ±0.5)
.3976" ±.028"
(10.1 ±0.5)
A
'AC GOOD' GREEN
'FAULT' YELLOW
'POWER GOOD' GREEN
Mechanical Dimensions