50-165 Watts NTQ160 Series Total Power: 50-165 Watts Input Voltage: 85-264 VAC # of Outputs: Quad Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current Special Features Environmental Operating temperature: 0° to 50°C ambient; derate each output at 2.5% per degree from 50° to 70°C Adjustment range Hold-up time Overload protection Overvoltage protection Standby output Power failure TTL logic signal goes high 100-500 msec after V1 output; it goes low at least 4 msec before loss of regulation Requires contact closure to inhibit outputs Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protection. TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation. Remote Inhibit Remote sense DC O Safety Humidity: Operating; non-condensing 10% to 95% Storage temperature: -40° to 85°C Temperature coefficient: ± .04% per °C MTBF demonstrated: >1 million hours at full load and 25°C ambient conditions 50W convection, 165 W with 30 CFM forced air 1.8V - 3.5V; 3.0V - 5.5V on outputs one and two 20 ms @ 165 W load Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating. Latching type recycle AC to reset. Tracks outputs 1 & 2: 20% to 35% above output setting 5V@ 2 A regulated ±5% Logic Control Electromagnetic susceptibility: Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5 Hz to 500 Hz, operational <1 mA @ 50/60 Hz, 264 VAC input Output Maximum power • Active power factor correction • EN61000-3-2 compliance • Remote sense on outputs one and two • Power fail and remote inhibit • 5V Standby output • DC Power good • Single wire current sharing on outputs one and two • Wide range adjustable on outputs 1 & 2 • Built-in Class B EMI filter • Overvoltage protection • Overload protection • Thermal overload protection • Outputs 3 & 4 are floating 85-264 VAC 47-63 Hz 38 A max., cold start @ 25°C 65% typical at full load @ 115 VAC input FCC Class B conducted and radiated, CISPR 22 Class B conducted and radiated, EN55022 Class B conducted and radiated, VDE 0878 PT3 Class B conducted and radiated. 0.99 typical VDE 0805/EN60950 (IEC950) UL CSA NEMKO UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 EN60950/EN41003 Certificate and report Mark (LVD) BABT CB CE 21310-3336-0021 (129066) E186249 LR109492C P00100493 650251, NC/00069 9661, 9662, 8788 rev 04.29.04 116 Americas: (760) 930-4600 Support: (888) 41-ASTEC or (407) 241-2752 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 NTQ160 Series Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 Ripple P/P (PARD)3 NTQ162 +3.3 V(1.8 - 3.5V) +5 V (3 - 5.5V) 12 V* 12 V* 2A 0A 0A 0A 15 A 10 A 2A 2A 30 A 20 A 4.5 A 4.5 A 38 A 22 A 5A 5A ±2% ±2% ±3% ±3% 50 mV 50 mV 120 mV 120 mV NTQ163 +5 V (3 - 5.5V) +3.3 V (1.8 - 3.5V) 12 V* 12 V* 2A 0A 0A 0A 15 A 10 A 2A 2A 30 A 20 A 4.5 A 4.5 A 32 A 22 A 5A 5A ±2% ±2% ±3% ±3% 50 mV 50 mV 120 mV 120 mV NTQ165 +3.3 V (3 - 5.5V) 2A 15 A 30 A 32 A ±2% +2.5 V (1.8 - 3.5V) 0 A 10 A 20 A 22 A ±2% 5 V* 0A 2A 4A 5A ±3% 12 V* 0A 2A 4A 5A ±3% * outputs are floating 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. Minimum loads are required. In parallel minimum loads are 2.5 A on the V1 output and 1 A on the V2 output for each power supply. 5. Total output current between V1 and V2 is 40A maximum. 50 mV 50 mV 120 mV 120 mV SK5 6 7 8 9 10 0.95 [24.0] Ordering Information 0.55 [14.0] C42 C86 C84 C48 C47 C41 R32 C68 R87 SEC_DB Z4 R73 HTSK-SEC3 R24 R25 R26 + + D24 R7 9 L13 R67 L10 + + D22 SCR1 TP1 + C23 C 1999 ASTEC Q5 CUSTOM POWER (PHIL.) 9 C24 T3 4 1 T1-W1 Q4 C21 7 VR3 C26 SO1 R34 1 + B+ 7.40 [188.0] R39 D10 R47 C18 + C63 C19 + 6 8.50 [216.0] IC2 + 10 C60 12 6.61 [168.0] 5 THR5 T2 D12 IC6 Z1 B- T1-W1A D17 R63 HTSK-SEC2 R42 P401 3 D1 C22 C31 R65 IC9 1 D13 + R48 042-66102310D Q8 L5 + + Q7 L8 R80 R68 D19 L6 R84 D21 D20 D18 R35 C94 HTSK-SEC1 C72 R30 R89 R66 D27 C40 C37 R27 IC7 L9 C36 R77 D23 + C20 D11 HTSK-PRI2 R31 B+ R6 D16 C70 C11 C10 + PRI_DB C5 R64 Q2 Z2 Q3 b + IC8 C33 VR2 VR1 C29 C27 + + C28 R95 L12 HTSK-PRI1 R5 C9 D1 L3 DB1 C4 B- Q1 b (SK6) ±12V Molex:09-50-8041 (USA) Molex: 09-91-0400 (UK) PINS: 08-58-0111 (SK5) Control Signals: Molex: 90142-0010 PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 Astec Connector Kit #70-841-014, includes all of the above L2 THR1 SK1 C3 F4A 250V F1 C71 C2 4 C3 Molex: 09-50-8051 (USA) Molex: 09-91-0500 (UK) PINS: 08-58-0111 Molex BB-124-08 HTSK-RECT L4 L1 VDR1 C1 SK2,3,4: V2 SWP 5V Standby +V2 Sense V1 SWP COMMON +V1 Sense Sense COMMON Remote Inhibit DC Power Good Power Fail C66 PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 Mating Connectors (SK1) AC Input: SK5 R94 R58 R57 R56 R55 SK2 SK3 SK4 SK6 a 1 L15 + 2 + + THR3 THR2 C38 PIN 1 PIN 2 PIN 3 PIN 4 V1 Common V2 V4 Common V4 V3 Common V3 THR4 C67 Ground Neutral Live L7 PIN 1 PIN 3 PIN 5 + C46 C43 C77 SK1 3 10 1 R41 SK3 D9 SK4 C89 C91 4 R46 C85 R78 L11 SK2 SK6 SK6 Connector SK4 SK5 SK3 1 2 3 4 5 SK2 5 3 a 1 SK1 4.25 [108.0] 0.75 [19.0] 1.50 [38.1] Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance ±.02”. 3. Remote inhibit requires an external contact closure to activate 4. Mounting maximum insertion depth is 0.12”. 5. Warranty: 1 year 6. Weight: 2.38 lb. /1.08 kg www.astecpower.com 117 R27 SK2 L6 HTSK-SEC1 SK3 C27 C33 L12 C68 C71 + SCR1 D23 SK4 C5 DB1 C4 THR1 R41 R65 VDR1 T1-W1A D17 R63 R48 R77 + + + THR4 R46 R66 + D18 4.25 [108.0] + C40 R89 + + + R31 4 5 R35 Z1 2 C20 D11 SK1 3 C19 R39 1 C18 D13 R30 C48 + 3 SK6 NTQ160 Series 4 C3 C46 C43 SK2 R73 C89 R80 C91 Q2 D19 12 1 Q8 Z4 SK3 SO1 Q7 C21 VR3 C26 T2 R24 R25 R26 7 6 SK4 TP1 T1-W1 D9 10 C29 C42 R64 SEC_DB 1 C41 C 1999 ASTEC Q5 CUSTOM POWER (PHIL.) B- C24 Q4 C3 C86 C84 SK5 C70 Q3 L4 L5 10 1 T3 C47 9 1 R87 1 + C85 R78 R6 Q1 HTSK-RECT D20 D1 R5 D16 HTSK-PRI1 L1 R34 IC9 F4A 250V C63 L2 PRI_DB F1 + B+ HTSK-SEC3 C23 5 D10 C11 VR2 VR1 HTSK-SEC2 042-66102310D C37 B+ B- C9 IC6 R47 C31 C60 L13 D12 IC2 C2 C22 C10 + + Z2 D21 + D22 4 D27 SK1 + P401 R7 9 THR5 + C66 R84 3 D1 R94 R58 R57 R56 R55 + R95 + C67 + L7 C36 R42 C28 L8 C38 L9 D24 C94 THR2 C72 R67 R68 THR3 IC7 L10 C77 R32 SK5 1 2 3 4 5 L11 6 7 8 9 10 IC8 HTSK-PRI2 L15 L3 SK6 C1 + a b b a 1.50 [38.1] 0.75 [19.0] 6.61 [168.0] 8.50 [216.0] 0.55 [14.0] 7.40 [188.0] 0.95 [24.0] 0.88 [22.3] 1.07 [27.3] a a b b 2.50 [63.5] 2.11 [53.5] b b a a M3 (8 PLACES) #6-32 (8 PLACES)