FUJIKURA PSMC

PSM-G,PSM-D Data sheet
Pressure sensor module/Gauge,Differential
Features
.
.
.
.
Applications
. Industrial instrumentation
Accuracy, 1.0 FS
. Pressure switch, Pneumatic device
Volt level output
Piggy-back style, pre-amplified and pre-compensated module . Medical device
Pre-calibration of offset voltage and span
Part number for ordering
PSM C - 025KP G
Model
PSM
Rated pressure(Pa)
Available pressure media
No mark : Non-corrosive gas only
C
: Non-corrosive gas and liquid
(Contact us about availability)
Pressure type
Pressure type
G : Gauge(Positive pressure)
GV : Gauge(Negative pressure)
GW : Gauge(Bipolar pressure)
D : Differential(Positive pressure)
DV : Differential(Negative pressure)
DW : Differential(Bipolar pressure)
Gauge pressure
PSM-G
Differential pressure
PSM-D
Package configuration
Piggy-back style module
Piggy-back style module
Measurable pressure range (kPa)
100 100
0
100
0 25
0 50
0 100
0 200
PSM-100KPGW
PSM-100KPGV
PSM-025KPG
PSM-050KPG
PSM-100KPG
PSM-200KPG
Model
Part number for ordering
PSM-100KPDW
PSM-100KPDV
PSM-025KPD
PSM-050KPD
PSM-100KPD
PSM-200KPD
Specifications
Model/Rated pressure
100KPGW
100KPDW
100KPGV
100KPDV
025KPG
025KPD
050KPG
050KPD
100KPG
100KPD
Recommended operating conditions
Pressure type
Gauge pressure
100
100
25
50
100
Rated pressure
1.020
1.020
0.255
0.510
1.020
Measurable pressure range
100 100
0
100
0 25
0 50
0 100
Pressure media 1
PSM : Non-corrosive gas only, PSMC : Non-corrosive gas and liquid
Excitation voltage
5 0.25
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation voltage
7
Operating temperature
20 100
Storage temperature
40 120
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 5
Mechanical response time
2 (For the reference)
0.5 ( 100kPa)
0.5 (0kPa)
0.5 (0kPa)
0.5 (0kPa)
0.5 (0kPa)
Output voltage 2, 3
4.5 (100kPa)
4.5 ( 100kPa)
4.5 (25kPa)
4.5 (50kPa)
4.5 (100kPa)
Full scale span voltage 3
4.0
Offset voltage 2, 3
0.5 0.04
Full scale span voltage 2, 3
4.5 0.04
Accuracy 3
1.0
Note ;
1) Please consult us available when you choose the C models.
2) Output refers to pressure at pressure port 2.
3) Excluding input voltage error.
1
200KPG
200KPD
Unit
200
2.040
0 200
kPa
kg/cm2
kPa
VDC
VDC
RH
mA
msec
0.5 (0kPa)
V
4.5 (200kPa)
V
V
V
FS/0 50
PSM-G,PSM-D Data sheet
Pressure sensor module/Gauge,Differential
Outline dimensions
ELECTRICAL
PIN CONNECTIONS
unit (mm)
7
3max
PIN NO. SYMBOL
Pressure port
22.86
900mil
Vcc
NO PIN
Vout
NC
NC
NC
NC
NC
NC
NC
NC
GND
11.5
12
3
22.9
Labelled faceplate
Pressure sensor
0.25
8
9
6
1
14
11- 1.8 (Diameter of lands)
11- 0.9 (Diameter of through holes)
2.54 2.54 2.54
7
4.8
1.6
7max
15max
Recommended footprint for PCB
0.5
2.54
12.7
2.54 5
7
ELECTRICAL
PIN CONNECTIONS
unit (mm)
3max
Pressure port 2
PIN NO. SYMBOL
Labelled faceplate
22.86
900mil
2
3.3
Vcc
NO PIN
Vout
NC
NC
NC
NC
NC
NC
NC
NC
GND
Pressure sensor
0.8
7.5
1
14
6
5
R0.5
Recommended footprint for PCB
6max
11max
2.5
6
0.25
11.5
8
22.9
Pressure port 1
11- 1.8 (Diameter of lands)
0.5
2.54
12.7
2.54 5
22.9
2.54
2.54 2.54 2.54
7
4.8
1.6
11- 0.9 (Diameter of through holes)
2.54
PSM-D
unit(mm)
22.9
20
12
2.54
17.8
2.54
12
PSM-G
unit(mm)
Transfer Function
Vout=Vs (P
+ ) (Pressure Error Temperature Error Multiplier
Vs=5.0volts
P=Input Pressure(kPa)
Temperature Error Multiplier=1
Model
025KPG(D)
050KPG(D)
100KPG(D)
100KPGV(DV)
100KPGW(DW)
200KPG(D)
pressure range
0 25kPa
0 50kPa
0 100kPa
0
100kPa
0 +100kPa
0 200kPa
Vs)
0.032
0.016
0.008
0.008
0.004
0.004
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
2
E-mail : [email protected]
0.1
0.1
0.1
0.1
0.5
0.1
Pressure Error(kPa)
0.25
0.5
1.0
1.0
2.0
2.0