XFPM,XFAM Data sheet Pre-amplified/5V Excitation/Absolute Features . . . . Applications . . . . Two accuracy ranks, 1.5 FS and 2.5 FS available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Industrial instrumentation Medical device Barometer, Altimeter Altitude compensation Part number for ordering XFAM - 115KP A S R H Accuracy No mark : H : FS FS(Contact us about availability) Terminal leads direction (See Outline Diagram) No mark : Rated pressure (Pa) Model XFPM XFAM 2.5 1.5 R : Pressure type A : Absolute Terminal leads configuration No mark : DIP(XFPM) S : Surface mount package(XFAM) Pressure type Absolute pressure XFPM XFAM Dual-In-line-Package (DIP) Surface mount package Model Package configuration Measurable pressure range (kPa) 15 115 XFPM-115KPA Part number for ordering XFPM-115KPAR XFAM-115KPASR Specifications Model/Rated pressure 115KPA Recommended operating conditions Pressure type Absolute pressure Rated pressure 115 Measurable pressure range 15 115 Pressure media Non-corrosive gas only Excitation voltage 5 0.25 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 40 125 Storage temperature 40 125 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.5 Offset voltage 0.2 0.1125, 0.2 0.0675(H) Full scale span voltage 4.7 0.1125, 4.7 0.0675(H) Accuracy 2.5, 1.5(H) Note ; Excluding input voltage error. Please consult us available liquid pressure media when you chose the H models. 1 Unit kPa.abs kPa.abs VDC VDC RH mA mA mA msec V V V FS/0 85 XFPM,XFAM Data sheet Pre-amplified/5V Excitation/Absolute Outline dimensions Unit : mm XFPM (Absolute pressure) 8 5.5 12 Pressure port 2.85 5 4 1 2 3 3 R 14 4 5 6 3 2 1 15.24(600mil) 1. 5 6 C 5 5 0. Labelled faceplate 2.54 2.54 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 2.54 2.54 1.2 0.5 60 Recommended footprint for PCB 2.8 6.8 15.2 (unit : mm) Unit : mm 0.25 XFPM-R (Absolute pressure) 5 4 1 2 3 8 Pressure port 2.85 4 5 6 3 2 1 0. C 15.24(600mil) 14 3 R 1. 5 6 5.5 max.15 12 5 5 2.54 2.54 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 2.8 2.54 2.54 60 1.2 0.5 Labelled faceplate 6.8 15.2 2 (unit : mm) XFPM,XFAM Data sheet Pre-amplified/5V Excitation/Absolute Outline dimensions Unit : mm XFAM 2.54 2.54 2 3 7 1 Pressure port 6 5 4 0.8 7 Index 3.5 0.25 10 M AX. 0.15 1 3 Recommended footprint for PCB . 15 0.8 X MA 6 5 4 1 2 3 Labelled faceplate 1.7 Land-pads 2.54 2.54 1.4 10.3 9.4 (unit : mm) Transfer Function Vout=Vs (P + ) (Pressure Error Temperature Error Multiplier Vs) Vs=5.0volts Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage. P=Input Pressure(kPa) Model 025KPG(D) 050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 25kPa 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.036 0.018 0.009 0.009 0.0045 0.0045 0.0009 0.009 Temperature Error Multiplier Temperature Error Multiplier 3.5 3 2.5 2 1.5 1 0.5 0 -40 -20 0 20 40 60 80 85 100 125 120 Temperature 3 0.04 0.04 0.04 0.04 0.49 0.04 0.04 0.095 Pressure Error(kPa) 0.625 1.25 2.5 2.5 5.0 5.0 25 2.5 Pre-amplified/5V Excitation/Absolute XFPM,XFAM Data sheet Connection diagram XFPM (Absolute pressure) Vcc(DC5V) Vcc Vout Vout GND C2 Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 2 and 3 pins must be No Connection. Open them as float-ing ones completely, and do NOT connect to other line or each other. XFAM C1 GND Vcc(DC5V) GND Vout Vout Vcc C2 Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as float-ing ones completely, and do NOT connect to other line or each other. C1 GND Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : [email protected]